1 Heat /1 Cool Manual Ch angeover Bat ter y or Har dwire d RT5 Non-Programmable Electronic Thermostat Installation, Operation & Application Guide • For use with Friedrich PT AC units ONL Y • B.
T able of Contents Parts Diagram............................................................................................................................................... 1 Speci fi cations .......................................................
1 P arts Diagram.
2 Electrical rating: • 24 V AC (18-30 V AC) • DC Power: 3.0 VDC (2 “AA” batteries included) • 1 amp maximum per terminal • 3 amp maximum total load T emperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.
3 ELECTRICAL SHOCK HAZARD – T urn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. 1. Turn of f power to the heating and cooling system by removing the fuse or switching the appropriate circuit breaker off.
4 T o Install Thermostat (continued) 2. T o remove cover, insert and twist a coin or screwdriver in the slots on the sides of the thermostat. 3. Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire opening in the base of the thermostat).
5 HARDWIRED C R W Y B GL GH C RH RC W Y B O GL GH PRE-INST ALLED JUMPER T H E R M O S T A T F R I E D R I C H P T A C.
6 The con fi guration mode is used to set the RT5 to match your heating/cooling system. The RT5 functions with Friedrich PT AC models. Ensure that the thermostat is con fi gured for air conditioning with ELECTRIC HEA T ONL Y . T o con fi gure the R T5, perform the following steps: 1.
7 FIL TER DIFF ROOM SET REMOTE 3. Temperature Differential (1°F to 3°F) (0.5°C to 1.5°C) – Set the number of degrees between your “setpoint” temperature and your “turn on” temperature. Press the or button to set differential value. Press the SW6 button to advance to the next screen.
8 FIL TER DIFF ROOM SET REMOTE 6. Room temperature offset (+9°F to -9°F) (+4.5°C to -4.5°C) Adjust to calibrate displayed room temperature to match actual room temperature. Note: When not set to 0, ROOM will display Press the or button to select. Press the SW6 button to advance to the next screen.
9 Once the thermostat is installed, it should be thoroughly tested. caution! : Do not energize the air conditioning system when the outdoor temperature is below 50 degrees. It can result in equipment damage or personal injury . Cool T est 1. Slide Mode switch to Cool mode.
10 Fan T est 1. Slide Fan switch to On position. 2. Indoor fan turns on. Auto On Auto On 3. Slide Fan switch to Auto position. 4. Indoor fan turns off. (T esting the thermostat continued from Page 9) The RT5 is a single-stage heat, single-stage cool thermostat.
11 Symptom Remedy No display For Hardwired Installation Check for 24 V AC at thermostat; display is blank when 24 V AC is not present For Battery Installation Display is blank when batteries are drain.
Friedr ich Air C onditioning Co. Post O f fice B ox 1 540 • S an Antonio, T ex as 782 95 - 1 54 0 42 00 N. Pan A m E xpre ss way • San Antonio, T ex as 782 1 8-52 1 2 (2 1 0) 35 7-4 4 0 0 • FA X (2 1 0) 3 57 - 4 4 80 w w w .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Friedrich RT5 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Friedrich RT5 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Friedrich RT5, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Friedrich RT5 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Friedrich RT5, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Friedrich RT5.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Friedrich RT5. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Friedrich RT5 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.