SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers.
www .fmiproducts.com 1 1 1099-01L 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert.
www .fmiproducts.com 1 1 1099-01L 3 SPECIFICA TIONS 0" TO BOTTOM (LEFT SIDE ONL Y) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 66" X 20" TO PERPENDICUL.
www .fmiproducts.com 1 1 1099-01L 4 FIREPLACE INST ALLA TION FRAMING 1. Frame opening for the replace using dimensionsshowninFigures1and2.
www .fmiproducts.com 1 1 1099-01L 5 DRAIN P AN (DP42) Foroutdoor installations,thereplace enclo - sure must allow for adequate drainage and fresh air ventilation.
www .fmiproducts.com 1 1 1099-01L 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 44 " 12-8DM 12-8HT PipeSection 10 5 / 8 " 18-8DM 18-8HT PipeSection.
www .fmiproducts.com 1 1 1099-01L 7 VENTING INST ALLA TION Continued Continue to assemble chimney sections as outlined, making sure that both the inner and outer pipe sections are locked together .
www .fmiproducts.com 1 1 1099-01L 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-8DM) Firestop spacers are required at each point where the chimney penetrates a oor space.
www .fmiproducts.com 1 1 1099-01L 9 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No.
www .fmiproducts.com 1 1 1099-01L 10 T erminations with 16" slip pipe sections are available. TheRTT -8DM andRTTL-8DM are approved for flashing installations. When needed, these adjustable terminations may be used in combination with the pipe assembly to achieve the correct chimney height.
www .fmiproducts.com 1 1 1099-01L 11 OPTIONAL GAS LINE INST ALLA TION Figure 19 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outsideof Fireplace GasLine Conduit Insulation Gas Conduit Cover 1/2"Dowel (see Figure 20, page 12).
www .fmiproducts.com 1 1 1099-01L 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints.
www .fmiproducts.com 1 1 1099-01L 13 DoorsFullyClosed FireplaceFront Doors FullyOpened FireplaceFront OPERA TION AND MAINTENANCE GUIDELINES Figure 21 - Glass Doors GLASS DOORS Glass doors are optional with the replace.
www .fmiproducts.com 1 1 1099-01L 14 OPERA TION AND MAINTENANCE GUIDELINES Continued OUTSIDE AIR AND DAMPER HANDLE OPERA TION The damper handle,which opens and closes the damper blade, is located in the upper front faceof thereplace.
www .fmiproducts.com 1 1 1099-01L 15 KEY NO. P ART NO. DESCRIPTION QTY . 9 107812-03 LeftRefractory ,T exturedWhiteBrick • 1 108169-03 LeftRefractory ,T exturedWhiteHerringbo.
www .fmiproducts.com 1 1 1099-01L 16 P ARTS WOOD BURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42, VS42H, VS42R AND VS42RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 1.
www .fmiproducts.com 1 1 1099-01L 17 KEY NO. P ART NO. DESCRIPTION QTY . 1 107797-01 InsulationPan 1 2 ** FireplaceT op 1 3 107800-01 FireplaceSurround 1 4 106642-01 AirRodRetainer 1 5 .
www .fmiproducts.com 1 1 1099-01L 18 ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 48-8HT ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - .
www .fmiproducts.com 1 1 1099-01L 19 ACCESSORIES Continued STORM COLLAR SC1-1 For RT -8DM and RTL-8DM SC2-1 For RTT -8DM and RTTL-8DM OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KI.
www .fmiproducts.com 1 1 1099-01L 20 1 1 1099-01 Rev .L 03/1 1 2701S.HarborBlvd. Santa Ana,CA 92704 1-866-328-4537 www .fmipr oducts.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté FMI S42 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du FMI S42 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation FMI S42, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le FMI S42 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le FMI S42, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du FMI S42.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le FMI S42. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei FMI S42 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.