For more information, visit www .fmiproducts.com W ARNING: If the information in this manual is not followed exactly , a re or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
www .fmiproducts.com 125078-01B 2 SAFETY W ARNING: Improper instal - lation, adjustment, alteration, service or maintenance can ca us e i njur y or prop erty dam ag e.
www .fmiproducts.com 125078-01B 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the replace may not be working properly . Get fresh air at once! Have replace serviced.
www .fmiproducts.com 125078-01B 4 1. For propane/LP replace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. T o prevent performance pro ble ms, do not use prop ane/L P fue l tank of less than 100 lb.
www .fmiproducts.com 125078-01B 5 Figure 1 - Direct V ent Fireplace Outer Glass Door Log Set Flue Collar Nailing Flange Lower Door/ Control Cover Herringbone Brick Refractories PRODUCT IDENTIFICA TION.
www .fmiproducts.com 125078-01B 6 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation Figure 3 - Fireplace T op Dimensions PRE-INST ALLA TION LOCA TION AND Sp ACE REqUIREMENTS Determine the safest and most efcient loca - tion for your direct vent replace.
www .fmiproducts.com 125078-01B 7 C B A D E F G 3 2 1 4 5 6 7 W a ll CLEARANCES Minimum clearances to combustibles for the replace are as follows: *Back and sides 1" Perpendicular walls 6".
www .fmiproducts.com 125078-01B 8 Fixed Closed Openabl e Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METE RR ESTRICTED AREA (TERMIN AT ION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12" (30.
www .fmiproducts.com 125078-01B 9 REQUIREMENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used.
www .fmiproducts.com 125078-01B 10 VENTING INST ALLA TION NOTIC E: Do not seal terminat ion cap to vent pipe. Cap must be removable for vent inspection and maintenance.
www .fmiproducts.com 125078-01B 11 INST ALLA TION pLANNING Th er e a re t wo b as ic t yp es o f d ir ec t v en t installation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORT ANT : Horizontal square terminations require only inner portion of wall restop.
www .fmiproducts.com 125078-01B 12 VENTING INST ALLA TION Continued 5. Noncombustible Exterior Wall: Positi on horizontal vent cap in center of the 8 1 / 2 " round hole and attach to exterior wall with four wood screws provided.
www .fmiproducts.com 125078-01B 13 VENTING INST ALLA TION Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind.
www .fmiproducts.com 125078-01B 14 Flat Ceiling Installation 1. Cut a 1 1 1 / 2 " square hole in ceiling using loca ting hol e as a cent er point. Ope ning should be framed to 1 1 1 / 2 " x 1 1 1 / 2 " in side dime nsio ns, as shown in Figure 8 on page 9 using frami ng lumbe r the s ame size a s ceil ing joist s.
www .fmiproducts.com 125078-01B 15 Figure 16 - Installing Firestop If area above is a living space, install restop below framed hole. If area above is an attic or insulated area, install restop above framed hole.
www .fmiproducts.com 125078-01B 16 FIREPLACE INST ALLA TION CHECK GAS TYPE Use proper gas type for the replace unit you are ins tal lin g. If you have con ic tin g gas types , do not install replace. See retailer where you purchased the replace for proper replace according to your gas type.
www .fmiproducts.com 125078-01B 17 Check your building codes for any special requirements for locating equipment shutoff valve to replaces. Apply pipe joint sealant lightly to male NPT threads . This will prevent excess sealant from going into pipe.
www .fmiproducts.com 125078-01B 18 FIREPLACE INST ALLA TION Continued CHECKING GAS CONNECTIONS W ARNI NG: T est all gas pipi ng and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once. W ARNING: Never use an open ame to check for a leak.
www .fmiproducts.com 125078-01B 19 FIREPLACE INST ALLA TION Continued 3. Make sure control knob of replace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 22 or Figure 23, page 18). Apply noncorrosive leak detection uid to all joints.
www .fmiproducts.com 125078-01B 20 FIREPLACE INST ALLA TION Continued LA V A ROCK, DECORA TIVE GRA TE, EMBER FLAKES AND SCRAP LOG INST ALLA TION Lava rock, ember akes and scrap log pieces are included with your replace. Install these items while glass doors are open and/or removed.
www .fmiproducts.com 125078-01B 21 FIREPLACE INST ALLA TION Continued INST ALLING BA TTERIES IN WIRELESS HAND-HELD REMOTE CONTROL AND RECEIVER Installing Batteries in Remote Receiver 1. Open bottom access door . 2. Remove switch plate from receiver (see Figure 31).
www .fmiproducts.com 125078-01B 22 OPERA TION FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a re or explosion may result causing property damage, per - sonal injury or loss of life. A. Thi s app lia nce is equ ipp ed with an igni - tion device which automatically lights the pilot.
www .fmiproducts.com 125078-01B 23 5. T urn equipment shutoff valve clockwise to the OFF position (see Figure 33). Do not force. 6. W ait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor . If you smell gas, STOP! Follow “B” in the safety information page 22.
www .fmiproducts.com 125078-01B 24 INSPECTING B URNERS Pilot Burner Ignitor/ Sensor Figure 35 - Correct Pilot Flame Pattern Sensing Rod Check pilot ame pattern and burne r ame patterns often. pILOT ASSEMBL Y The pilot assembly is factory preset for the proper ame.
www .fmiproducts.com 125078-01B 25 Glass must be cleaned periodically . During start-up it is normal for condensation to form on the insi de of the glass causin g lint, dus t and other airborne particles to cling to the glass surf ace. Durin g init ial start- up a slight lm may form on the glass due to paint curing.
www .fmiproducts.com 125078-01B 26 TROUBLESHOO TING W ARNING: T urn off replace and let cool before servicing. Only a qualied service person should service and repair replace. CAUTION: Never use a wire, needle or similar object to clean pilot.
www .fmiproducts.com 125078-01B 27 OBSERVED PROBLEM Pilot will not stay lit No gas to burner , although safety shutoff switch and valve are set to the ON position Frequent pilot outage Fireplace produces a clicking/ ticking noise just after burner is lit or shut off Slight smoke or odor during initial operation REMEDY 1.
www .fmiproducts.com 125078-01B 28 TROUBLESHOO TING Continued W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
www .fmiproducts.com 125078-01B 29 SPECIFICA TIONS (V)DVF36NS, (V)DVF36NH • Rating: 33,500 Btu/hr • Gas T ype: Natural Gas Only • Ignition: Electronic • Manifold Pressure: 3.5" w .c. • Minimum Inlet Supply Pressure: 5" w .c. • Maximum Inlet Supply Pressure: 10.
www .fmiproducts.com 125078-01B 30 P ARTS MODELS (V)DVF 36NS , ( V)DV F36 PS, (V) DVF3 6NH , ( V)DV F36 PH, DVF -36N S- HA, DVF 36N H-HA , (V)D VF42 NS, (V) DVF 42P S, ( V)D VF42 NH, (V) DVF 42PH , DV.
www .fmiproducts.com 125078-01B 31 P ARTS This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 36 of this manual.
www .fmiproducts.com 125078-01B 32 P ARTS B UR NE R AS S E MB L Y M OD EL S (V)DVF 36NS , ( V)DV F36 PS, (V) DVF 36NH , ( V) DVF 36PH , D VF-3 6NS -HA, DV F36N H-H A, (V)DVF4 2NS , (V )DV F42P S, (V) .
www .fmiproducts.com 125078-01B 33 KEY NO. P ART NO. DESCRIpTION QTY . 1 122839-02 Burner T ube, 36" • • • 1 122839-01 Burner T ube, 42" • • • 1 2 ** Front Burner Assembly • .
www .fmiproducts.com 125078-01B 34 P ARTS REFRACTOR Y p ARTS 1 2 4 5 6 3 Herringbone Brick Shown.
www .fmiproducts.com 125078-01B 35 DVF42(N,P)H(-HA) DVF36(N,P)H(-HA) DVF42(N,P)S(-HA) DVF36(N,P)S(-HA) KEY NO. P ART NO. DESCRIpTION qTY . 1 125124-01 Rear Refractory , Herringbone 42" White • .
www .fmiproducts.com 125078-01B 36 TECHNICAL SERVICE Y ou may have further questions about installation, operation, or troubleshooting. I f s o , c o nt a c t F M I P R O DU C T S , L L C a t 1-866-328-4537. When calling please have your model and serial numbers of your heater ready .
www .fmiproducts.com 125078-01B 37 _____________________________________________________ ______________________________________________________ ______________________________________________________ _.
www .fmiproducts.com 125078-01B 38 _____________________________________________________ ______________________________________________________ ______________________________________________________ _.
www .fmiproducts.com 125078-01B 39 _____________________________________________________ ______________________________________________________ ______________________________________________________ _.
125078-01 Rev . B 3/10 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES New products Standard Warranty: FM I PR O D UC TS , LL C w ar ra nt s th i s ne w pr o d u ct an d a n y pa rt .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté FMI (V)DVF36PS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du FMI (V)DVF36PS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation FMI (V)DVF36PS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le FMI (V)DVF36PS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le FMI (V)DVF36PS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du FMI (V)DVF36PS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le FMI (V)DVF36PS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei FMI (V)DVF36PS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.