Manuel d'utilisation / d'entretien du produit VFHS-20/10T-4 du fabricant Empire Comfort Systems
Aller à la page of 28
Page 1 16717-2-0605 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL This is an unvented gas-fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventila- tion air must be pr ovided. Refer to page 6.
Page 2 16717-2-0605 SECTION P AGE Important Safety Information .....................................................................................................................3 Safety Information for Users of LP Gas ..............................
Page 3 16717-2-0605 Wh en u sed w it ho ut ad eq ua te co mb us ti on an d ven ti la ti on ai r, he at er ma y g iv e off C ARB ON M ONO XI DE, a n odo rl ess , po is on ou s gas . Do not install heater until all necessary provisions are made for combu stion and ventilation air .
Page 4 16717-2-0605 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
Page 5 16717-2-0605 an Unvented Room Heater and should be installed according to these instructions. Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.
Page 6 16717-2-0605 Model VFHS-20R VFHS-20/10T Input Maximum 20,000 20,000/10,000 Minimum 14,000 7,000/7,000 Minimum Firebox Opening Height 26 3/4" 26 3/4" Depth 11 1/4" 11 1/4" Fr.
Page 7 16717-2-0605 3. Add the BTU/Hr of all fuel burning appliances in the space. V ent-free heater BTU/Hr Gas water heater BTU/Hr Gas furnace BTU/Hr V ented gas heater BTU/Hr Gas fireplace logs BTU.
Page 8 16717-2-0605 GAS SUPPL Y Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe T ubing, T ype L (Feet) Inside Diameter Outside Diameter Nat.
Page 9 16717-2-0605 CLEARANCES M i n i m um W al l a n d C e il i ng Cl e a ra n ce s 30” (762mm) 4” (101mm) Figure 4 This fireplace can be installed with zero (0") clearance to combustible material When facing the front of the appliance the minimum clearances to combustible construction (material) are the following: 1.
Page 10 16717-2-0605 INST ALLA TION OF FIREPLACE INT O MANTEL Installing Fireplace in Mantel ( Figur e 9) Figure 9 1. Position base approximately 5" from wall surface. 2. Attach nailing flange to fireplace top with two (2) 10 x 1/2" screws.
Page 1 1 16717-2-0605 Built-In Fireplace Installation Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If instal ling a mantel abov e the fireplace , you must follo w the clearances shown in Figure 5, page 9.
Page 12 16717-2-0605 PLACEMENT OF GLOWING EMBERS (ROCK WOOL) Provided with the log set is a small bag of glowing embers (rock wool) to be placed between logs on the flat metal surface of the burner . Placement of the embers (rock wool) is very individual and light coverage of the areas indicated will provide your best effects.
Page 13 16717-2-0605 HI/LO REGULA TOR CONTROL KNOB PIEZO IGNITOR FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life.
Page 14 16717-2-0605 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
Page 15 16717-2-0605 PILOT FLAME CHARACTERISTICS Figures 13 and 16 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet .
Page 16 16717-2-0605 The VFHS-20/10T gas control maximum and minimum inputs are listed below . OFF is the OFF position. PILOT is the PILOT position. VFHS-20/10T Max. 20,000 BTUH Min. 7,000 BTUH VFHS-20/10T can be converted to 10,000 BTU for Bedroom Installation Max.
Page 17 16717-2-0605 Label all wires prior to disconnection when servicing controls. W iring errors can caus e improper and dangerous operation. V erify proper operation after servicing. Millivolt thermopile is self powered, gas valve does not require 1 10 volts.
Page 18 16717-2-0605 If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pr essure is low , contact your local gas supplier immediately . 1. When ignitor button is pressed, there is no spark at ODS/ pilot.
Page 19 16717-2-0605 Empir e Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62220-2623 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P ARTS COULD CAUSE INJUR Y OR DEA TH. Index Part No. Number Description Index Part No.
Page 20 16717-2-0605 P AR TS VIEW.
Page 21 16717-2-0605 INST ALLING OPTIONAL BRICK LINER EHL-24-1. 1. Remove screen assembly from fireplace. 2. Remove logs from burner assembly . 3. Insert rear brick liner and (2) side brick liners onto bottom of the inner casing. Align grout lines on rear brick liner with grout lines on side brick liners.
Page 22 16717-2-0605 INST ALLING OPTIONAL BLOWER VFS-BK 1. Lower bottom louver . 2. Remove screen front by lifting upward on screen front. 3. Remove top louver [(2) 8 x 1/2" Phillips screws]. 4. Remove rear log support from inner casing [three (3) 10 x 1/2" screws.
Page 23 16717-2-0605 23. Position blower shield side beneath left flange on burner assembly . Align clearance hole on left flange of burner assembly with screw hole on blower shield side. Attach burner assembly to blower shield side with one (1) 10 x 1/2" screw .
Page 24 16717-2-0605 28. Place fan control bracket with wires on top of inner casing. Remove right, front 10 x 1/2" screw from top of inner casing. Attach fan control bracket to top of inner casing with 10 x 1/2" screw . Refer to Figure 5 for correct position of fan control bracket for 10,000 Btu input or 20,000 Btu input.
Page 25 16717-2-0605 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electrical Code ANSI/NFP A No. 70 , if an external electrical source is utilized.
Page 26 16717-2-0605 SER VICE NOTES.
Page 27 16717-2-0605 SER VICE NOTES.
Page 28 16717-2-0605 SER VICE NOTES Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623 PH: 618-233-7420 PH: 800-851-3153 F AX: 618-233-7097 F AX: 800-443-8648 E-MAIL: info@empirecomfort.com WEB SITE: www .empirecomfort.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Empire Comfort Systems VFHS-20/10T-4 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Empire Comfort Systems VFHS-20/10T-4 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Empire Comfort Systems VFHS-20/10T-4, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Empire Comfort Systems VFHS-20/10T-4 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Empire Comfort Systems VFHS-20/10T-4, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Empire Comfort Systems VFHS-20/10T-4.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Empire Comfort Systems VFHS-20/10T-4. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Empire Comfort Systems VFHS-20/10T-4 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.