Net Weight: 27.0 Lbs. Part No. F40BP73080000 Form No. BP7308 READ AND SA VE THESE INSTRUCTIONS KF240PRZ00 Parisian Bronze with Dar k Cher r y/Walnut Blades LORRAINE Ceiling Fan Owner's Manual Eme.
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
3 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 p. One loose parts bag containing: 1. T wo 8-32 x 1-1/4” threaded studs 2. T wo knurled knobs 3. T wo lockwashers 4. Seven wire connectors 5. One clevis pin/hairpin clip assembly 6. Eleven 1/4-20 x 13mm oval head screws 7. Sixteen 10-24 x 8mm truss head screws 8.
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
4. Remove and retain one of the three pan head screw/lockwashers from the motor flange (Figure 2); loosen the other two pan head screws three or four turns. 5. Position the light fitter adapter on the motor flange so that the two screws mate with the two keyhole slots in the light fitter adapter (Figure 3).
8. Remove and retain the three outer screw/lockwashers from the light fitter adapter (Figure 4). 9. Position the light fitter assembly on the light fitter adapter . Line up the three holes on the light fitter with the threaded holes in the adapter and reinstall three screw/lockwashers (previously removed) (Figure 5).
8 12. Unscrew the two upper setscrews (Figure 8) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling.
9 16. Place the ceiling cover over the downrod. Then reinstall the hanger ball (Figure 10) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod.
10 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12). Hanger bracket must seat firmly against outlet box.
1. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. NOTE: Make all wiring connections using wire connectors (supplied).
12 7. Screw in three 40-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 17). Carefully place the lower glass over the light fitter threaded nipple. Be sure the glass is firmly seated on the fitter , then secure in place using a rubber washer , metal washer , and 1/8-27 nut (washers and nut are supplied).
Installation of W all Control SINGLE-POLE INST ALLA TION (Figure 19) 1. Disconnect power at circuit breaker or remove fuse. 2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control.
3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position. 4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire.
9. Place the second wall control into the wall box. Screw in place and install decorator style faceplate (included). Leave switch in “OFF” mode until fan installation is completed.
16 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this fan could result in fire, shock and personal injury .
17 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan.
Repair Parts 1 17 18 22 29 30 20 9 8 21 12 11 10 15 14 13 26 27 19 23 28 24 25 31 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 2 3 4 ON 2 3 5 4 16 6 7 Before discarding packaging material, be certain all parts have been removed.
Part Numbers Key Model No. N o . Description KF240PRZ00 * Hanger Pack, Consisting of: 761655-53 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod (16”) — * Parts Bag, Containing: 763046 4 Wire Conn.
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson KF240PRZ00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson KF240PRZ00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson KF240PRZ00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson KF240PRZ00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson KF240PRZ00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson KF240PRZ00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson KF240PRZ00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson KF240PRZ00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.