Manuel d'utilisation / d'entretien du produit CF980MBX 00 du fabricant Emerson
Aller à la page of 16
READ AND SA VE THESE INSTRUCTIONS Model No. CF980MAB 00 CF980MBX 00 EMX TUREEN ™ Part No. F40BP73530000 Form No. BP7353 U.L. Model No.: CF980 Net Weight: 35.
2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 .
T ools Needed for Assembly One Phillips head screwdriver One stepladder MA TERIALS Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes: Unpac king Instr uctions For your convenience, check-off boxes are provided next to each step.
4 Electrical R equir ements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
5 CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the bottom of the light kit assembly and fan motor. 5. Install the three #10-24 x 5/16” pan head screws to secure the light kit assembly to the lower housing (Figure 4).
6 12. Position one of the blade assemblies onto the motor hub and secure blade assembly using two 1/4-20 x 1/2” oval head flange screws (provided). Repeat for all blade assemblies (Figure 8). 13. Slide the coupler cover over the downrod and position it to cover the motor coupling (Figure 9).
7 2. Carefully lift the fan and seat the hanger ball/down- rod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12). Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
8 OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW RECEIVER WIRE DO NOT USE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE CONNE.
9 HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 16 YELLOW RECEIVER WIRE DO NOT USE DOWNROD WHITE SUPPL Y WIRE BLACK F AN WIRE SW105 RECEIVER TO 110V SUPPL Y WHITE F AN WIRE BLUE RECEIVER WIR.
2. Place the glass onto the light kit assembly aligning the three flat areas on the top flange of the glass with the three pins on the inside of the assembly (Figure 19). Then turn the glass clockwise until it stops turning. 3. Your ceiling fan is now installed and wire to be controlled by your remote control system.
11 Setting Oper a ting F requency of W all Contr ol and R eceiv er (Figur e 20) Your wall control and receiver have code switches which must be set in one of 16 possible code combi- nations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position.
12 AIRFLOW DIRECTION BUTTON LIGHT BUTTON FA N SPEED BUTTONS F AN OFF BUTTON RED INDICA TOR LIGHT FAN OFF LOW MED HI LIGHT REV Figure 23 T rouble Shooting W all Contr ol Fan/Light Fails to Operate • Check that the wall switch for the ceiling fan is in the “ON” position.
13 INSTRUCTION T O THE USER (if device contains a digital device) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer- ence in a residential installation.
T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing.
15 R epair Par ts 9 HI HI MED MED LOW LOW F A N O F F R E V R E V L I G H T 1 5 6 7 3 2 10 4 8 11 16 17 19 18 23 14 20 21 12 13 15 24 22.
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73530000 Printed in China 10/07 Form No.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson CF980MBX 00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson CF980MBX 00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson CF980MBX 00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson CF980MBX 00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson CF980MBX 00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson CF980MBX 00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson CF980MBX 00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson CF980MBX 00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.