Manuel d'utilisation / d'entretien du produit CF901BS00 du fabricant Emerson
Aller à la page of 16
Part No. F40BP74460000 Form No. BP7446 U.L. Model No.: CF901 READ AND SA VE THESE INSTRUCTIONS Ceiling F an Owner's Manual CF901BS00 CF901CK00 CF901GES00 Model Number s PRIMA ™ Net W eight: 20.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
Unpac king Instr uctions 1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing assembly c. Five fan blades d. One ceiling cover e.
Electrical R equir ements Ho w to Put Y our Ceiling F an T ogether 4 MOTOR COUPLING HAIRPIN CLIP CLEVIS PIN UPPER SETSCREW CLEVIS PIN HAIRPIN CLIP MOTOR COUPLING SETSCREW CLEVIS PIN DOWNROD SETSCREW F.
Ho w to Put Y our Ceiling F an T ogether (continued) 3. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 3).
11. Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly.
7 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). A T LEAST 7' CEILING FLOOR Figure 9 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
8 U.L. Model No.: CF901 Ho w to W ir e Y our Ceiling F an If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
W all Control Installation 9 U.L. Model No.: CF901 The fan speed control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.
10 Accessories Oper a tion of Re verse Switch All fans are shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in the opposite direction, turn your fan off and wait for the blades to stop turning, then slide the reversing switch to the opposite position, and turn fan on again.
11 T r ouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
12 U.L. Model No.: CF901 R epair Par ts 5 6 18 15 17 16 4 0 3 2 1 7 20 14 11 1 2 3 12 10 19 9 13 8 4.
13 R epair Par ts Listing Key Model Numbers No. Description CF901BS00 CF901CK00 CF901GES00 CF901ORB00 CF901VNB00 * Hanger Ball Assembly, 761655-17 761655-23 761655-35 761655-32 761655-89 Consisting of: 1 Hanger Bracket — — — — — 2 Hanger Ball — — — — — 3 Downrod (4.
14 U.L. Model No.: CF901 Notes.
15 U.L. Model No.: CF901 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
U.L. Model No.: CF901 Part No. F40BP74460000 Printed in China 12/11 Form No. BP7446 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson CF901BS00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson CF901BS00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson CF901BS00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson CF901BS00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson CF901BS00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson CF901BS00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson CF901BS00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson CF901BS00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.