Manuel d'utilisation / d'entretien du produit CF2455ORB00 du fabricant Emerson
Aller à la page of 16
READ AND SA VE THESE INSTRUCTIONS Part No. F40BP73370000 Form No. BP7337 U.L. Model No.: CF2455 Model No. CF2455BS00 CF2455ORB00 CF2455PW00 ODYSSEY ® Net W eight: 26.
2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 .
7. Seven wire connectors 8. Three 8-32 x 3/8" phillips head screws 9. One hairpin clip 10. One clevis pin 11. Two knurled knob screws 1 2 . Twenty-one 10-32 x 3/8" pan head screws 13. One jumper assembly NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost.
1. Position the fan motor and housing assembly in the lower styrofoam packing so that the top for the motor is facing you. 2. Obtain the hanger ball/downrod assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1).
5 6. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2).
6 12. Position the center styrofoam section on the upper section, and then position the fan motor and housing on the center section so that the bottom of the motor is facing you (Figure 5). The styrofoam sections will hold the assembly while you perform the following steps.
7 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”. W ARNING ! Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box.
OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW F AN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE C.
9 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER CEILING COVER Figure 16 BLUE RECEIVER WIRE YELLOW RECEIVER WIRE BLUE F AN WIRE DOWNROD BLACK F AN WIRE SW105 RECEIVER WHITE F AN WIR.
5. Obtain the die cast glass holders and light kit glass from the protective bags. 6. Position the light kit glass carefully on a convenient surface with the open side face down. 7. Remove the protective cover from the adhesive backed material on the glass holders (Figure 18).
The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.
Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your SW116 Fan/Light Wall Control (Figure 25) has full control of your fan, lights, and airflow direction.
13 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan.
14 4 2 1 3 5 6 7 10 3 11 25 8 7 31 30 29 15 15 20 21 22 23 24 28 27 12 13 14 8 26 9 HI MED LOW FAN OFF REV EMERSON D/L U/L 17 16 18 17 19 Repair Par ts.
15 Repair Par ts Listing Key Model No. N o . Description CF2455BS00 CF2455ORB00 CF2455PW00 1 Bracket Assembly, Hanger 760732 760732 760732 2 Hanger ball/downrod Assembly 761632-17 761632-37 761632-23 .
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 Printed in China 11/06 Part No. F40BP73370000 Form No. BP7337 LIMITED W ARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson CF2455ORB00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson CF2455ORB00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson CF2455ORB00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson CF2455ORB00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson CF2455ORB00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson CF2455ORB00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson CF2455ORB00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson CF2455ORB00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.