Manuel d'utilisation / d'entretien du produit CF110ORB00 du fabricant Emerson
Aller à la page of 16
Part No. F40BP74660000 Form No. BP7466 11/12 ETL Model No.: CF110 READ AND SA VE THESE INSTRUCTIONS CALLAN ™ 48” Ceiling F an Owner's Manual Model Numbers CF110BS00 - Br ushed Steel CF110ORB00 - Oil R ub bed Br onz e Net W eight: 23.
2 Safety Instructions TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a . Use this unit only in a manner intended by the manufacturer.
Unpacking Instructions 3 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co.
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 9). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
5 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 1/4-20 x 1/2" FLANGE SCREWS WITH LOCKWASHERS PRE-ASSEMBLED (2) FLANGE/BLADE ASSEMBL Y MOTOR HUB Figure .
6 ETL Model No.: CF110 9. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 8). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 14.
Electrical Requirements 7 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
8 ETL Model No.: CF110 A T LEAST 7' FLOOR CEILING Figure 13 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX Figure 14 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY .
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation).
10 ETL Model No.: CF110 This control is designed to operate only one ceiling fan, (Figure 18). This SW46 speed control is rated for 1.2 amps at 120 volts.. 1. Before disconnecting power, ensure that the fan is set at the highest speed. NOTE: Electric connections should be in accordance with the National Electrical Codes and all Local Codes.
11 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 8. Position the faceplate (provided) onto the SW46 speed control. Using the two 6-32 x 1/4” screws, screw the faceplate and speed control to the wall outlet box (Figure 21).
12 ETL Model No.: CF110 Repair Parts 4 9 8 1 5 2 3 6 14 15 16 17 7 22 4 0 3 2 1 13 18 19 11 21 20 12 10.
13 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 Repair Parts Listing Before discarding packaging material, be certain all parts have been removed.
14 ETL Model No.: CF110 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. WARNING ! IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
15 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 What The Limited Warranty Covers: This limited warranty is offered by Air Comfort Products division of Emerson Electric Co.
Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., EST , Monday-Friday 1-800-654-3545 www .emersonfans.com Retain this manual for future use. Air Comf or t Pr oducts DIVISION OF EMERSON ELECTRIC CO.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson CF110ORB00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson CF110ORB00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson CF110ORB00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson CF110ORB00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson CF110ORB00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson CF110ORB00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson CF110ORB00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson CF110ORB00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.