1. Do not spill any liquids on the charger. This may cause short circuits and contaminate the charging contacts. 2. If any liquid penetrates into the charging receptacle, disconnect the charger from power immediately and have the charger checked by AKG service personnel. 3. Never use the charger to charge dry batteries. The charger will detect dry batteries and automatically deactivate the charging function. 4. Use the charger in dry rooms only. 5. The charger may be opened, serviced, and repaired by authorized personnel only. The charger contains no user-serviceable parts. 6. Place the charger at least 1 inch away from walls or other equipment to ensure ade- quate heat dissipation from the charger. If the charger overheats, the charging cycle will be stopped immediately. 7. Before connecting the charger to power, check that the AC mains voltage stated on the included power supply is identical to the AC mains voltage available where you will use the charger. 8. Do not operate the charger with any power supply other than the included AC adapter with an output voltage of 5 VDC. Using a power supply with an AC output and/or a dif- ferent output voltage may cause serious damage to the charger. 9. If you will not use the charger for a long period of time, disconnect the charger from power. To prevent unwanted discharging, be sure to remove the transmitter(s) from the charger every time you disconnect the charger from power. 10. Do not place the charger near heat sources such as radiators, heating ducts, or am- plifiers, etc. and do not expose it to direct sunlight, excessive dust, moisture, rain, me- chanical vibrations, or shock. 11. Clean the charger with a moistened (not wet) cloth only. Be sure to disconnect the charger from power before cleaning the charger! Never use caustic or scouring clean- ers or cleaning agents containing alcohol or solvents since these may damage the enamel and plastic parts. 12. Use the charger for the applications described in this manual only. AKG cannot accept any liability for damages resulting from improper handling or misuse.
1. The charger will draw a low current even when the charging mode is off. To save en- ergy, disconnect the charger from power if you will not use the charger for a long pe- riod of time. To prevent unwanted discharging, be sure to remove the transmitter(s) from the charger every time you disconnect the charger from power. 2. Be sure to dispose of used batteries as required by local waste disposal rules. Never throw batteries into a fire (risk of explosion) or garbage can. 3. When scrapping the charger, separate the case, circuit boards, and cables, and dispose of all components in accordance with local waste disposal rules. 4. The packaging of the charger is recyclabe. To dispose of the packaging, make sure to use a collection/recycling system provided for that purpose and observe local legisla- tion relating to waste disposal and recycling.
Safety · Environment

Thank you for purchasing an AKG product. This Manual contains important instructions for setting up and operating your equipment. Please take a few minutes to read the instruc- tions below carefully before operating the equipment. Please keep the Manual for fu- ture reference. Have fun and impress your audience!
1 CU 400 charger
1 AC adapter (if checked on the packaging)
2 AA size NiMH rechargeable batteries (2100 mAh)
The charger provides two charging slots specially shaped to accept AKG handheld or body- pack transmitters. The charging slots operate completely independently so you can charge two rechargeable batteries simultaneously. You do not need to remove the battery from the transmitter for charging.
The charger checks the battery inside the transmitter and will automatically deactivate the charging function if it detects a dry battery.
There is one STATUS LED in front of each charging slot. These tricolor (red/orange/green) LEDs indicate the current operating status of the charger.
The DC 5V jack on the rear panel accepts the DC cable on the included AC adapter.


Each charging slot features a tricolor STATUS LED that indicates the current operating sta- tus of the respective charging slot (">…
--- The charger is ready to operate, no transmitter is inserted in the charging slot.
orange The battery inside the inserted transmitter is being checked.
red The battery is being charged.
green The battery is fully charged; the charging cycle is com- pleted.
>red< Error.
1. Check that a rechargeable battery is inside the transmitter battery compartment. Do not try to charge a dry battery. If there is no battery inside the battery compartment, do not place the transmitter in a charging slot before you inserted a rechargeable battery into the transmitter. 2. Make sure to switch the transmitter OFF before placing it in a charging slot. This is the only way to guarantee optimum charging. 3. Insert the transmitter into the charging slot so that the display on the transmitter faces the LEDs on the charger. The charger will automatically power the transmitter via the charging contacts. 4. Never switch the transmitter ON during the charging cycle. This may cause the charger to falsely indicate a completed charging cycle before charging is actu- ally completed.
Refer to fig. 2.
If the transmitter has been switched ON by accident during the charging cycle, 1. Remove the transmitter from the charger. 2. Switch the transmitter OFF. 3. Insert the transmitter into the charger.
The charging cycle will start automatically as soon as you insert a transmitter with a rechargeable battery into the charger.
Table 2: Charging cycle STATUS LED Status orange The voltage and temperature of the battery are being checked.
red The battery is being charged. Charging time is approx. 1.5 hours for a completely dis- charged battery and proportionately less for a partially discharged battery. Charging two batteries simultaneously will extend the charging time to 3 to 4 hours. green The battery is fully charged; the charging cycle is com- pleted. The charger has switched to trickle charging mode. You may remove the transmitter from the charger. Due to the charging process, the battery may heat up to +60°C. This is normal.
STATUS LED Status · indications · Charging Cycle



Problem Possible Cause Remedy
All LEDs dark. • No defect. STATUS LEDs are not activated before you insert a trans- mitter with a battery into a charg- ing slot.
All LEDs dark although at least one charging slot is loaded.
STATUS LED flashing red. • Charging cycle has been stopped: 1. Transmitter uses dry battery.

Operating voltage: 5 VDC, 1.5 A max. Recommended batteries: NiMH or NiCd rechargeable with 1500 mAh minimum capacity AC voltage: refer to label on AC adapter Charging current: typ. 1.4 A in single-slot mode typ. 0.7 A if both slots are used simultaneously Charging time: typ. 1.5 hours in single-slot mode typ. 3 hours if both slots are used simultaneously (depending on battery type and capacity) Size (LxHxD): 188 x 115 x 78 mm (7.4 x 4.5 x 3.1 in.) Weight: approx. 420 g (14.8 oz.)
This product conforms to the standards listed in the Declaration of Conformity. To order a free copy of the Declaration of Conformity, visit http://www.akg.com or contact sales@akg.com
The device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Statement




Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| All LEDs dark. | • No defect. STATUS LEDs are not activated before you insert a trans- mitter with a battery into a charg- ing slot. | • (Insert transmitter with recharge- able battery.) | p.7 |
| All LEDs dark although at least one charging slot is loaded. | 1. AC adapter is not connected to power. 2. DC cable is no not connected to charger. 3. One or more charging contacts fail to make contact with the transmitter. 4. Internal error. | 1. Connect power supply to conven- ient power outlet. 2. Connect DC cable to charger. 3. Check contacts for resilience, or clean contacts. 4. Disconnect power supply or DC cable, wait for 10 seconds, and connect again. Should the problem persist, contact your nearest AKG Service Center. | p.7 |
| STATUS LED flashing red. | • Charging cycle has been stopped: 1. Transmitter uses dry battery. 2. Charging contacts contaminated. 3. Inside temperature of battery is too high. 4. Inside temperature of charger is too high. 5. Battery defective (voltage <0.5 V). 6. Charger connected to incompatible power supply whose output voltage is too high: both STATUS LEDs flashing red. 7. Charger defective. | 1. Remove transmitter from charging slot; replace dry with rechargeable battery. 2. Clean charging contacts on charger and transmitter with soft cloth. 3. Allow battery/charger to cool down, charging cycle will resume when temperature returns to acceptable range. Should the problem persist, contact your nearest AKG Service Center. 4. Make sure there is enough free space around charger to provide adequate heat dissipation. 5. Replace battery. 6. Use original AC adapter supplied with charger. 7. Contact your nearest AKG Service Center. | p.7 |