Power Blower Operator's Manual MODELS PB-500H PB-500T W ARNING Read rules for safe operation and all instructions carefully . ECHO provides this Operator's Manual which must be read and understood for proper and safe opera- tion.
2 I n t r o d u c t I o n W elcome to the ECHO family . This ECHO product was designed and manufactured to provide long life and on-the- job-dependability . Read and understand this manual. Y ou will nd it easy to use and full of helpful operating tips and SAFETY messages.
3 P o w e r B l o w e r o P e r a t o r ' s M a n u a l I n t e r n a t I o n a l s y m b o l s Symbol description/application Symbol form/shape Symbol description/application Symbol form/shape Read and understand Operator's Manual.
4 Physical Condition Y our judgment and physical dexterity may not be good: • if you are tired or sick, • if you are taking medication, • if you have taken alcohol or drugs. Operate unit only if you are physically and mentally well. Eye Protection W ear eye protection that meets ANSI Z87.
5 P o w e r B l o w e r o P e r a t o r ' s M a n u a l DANGER Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous emissions and can cause serious injury or death.
6 W ARNING Use only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment com - bination. ECHO, INC. will not be responsible for the failure of cutting devices, attachments or accessories which have not been tested and approved by ECHO.
7 P o w e r B l o w e r o P e r a t o r ' s M a n u a l 10 11 12 1 2 3 5 6 7 4 d e s c r I p t I o n PB-500H Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instruc- tions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer .
8 1. SAFETY DECAL - Lists important safety precautions. 2. SP ARK PLUG - Provides spark to ignite fuel mixture. 3. SP ARK ARRESTOR MUFFLER OR SP ARK ARRESTOR MUFFLER WITH CA T AL YST - The mufer or catalytic mufer controls exhaust noise and emission.
9 P o w e r B l o w e r o P e r a t o r ' s M a n u a l 10 11 12 13 14 6 15 P/N X505002080 General W arning Decal (located on blower housing) P/N X505002310 Hot Decal (near mufer) 70 Category II dB(A) Measured at 50 ft.
10 1. SAFETY DECAL - Lists important safety precautions. 2. SP ARK PLUG - Provides spark to ignite fuel mixture. 3. SP ARK ARRESTOR MUFFLER OR SP ARK ARRESTOR MUFFLER WITH CA T AL YST - The mufer or catalytic mufer controls exhaust noise and emission.
11 P o w e r B l o w e r o P e r a t o r ' s M a n u a l c o n t e n t s PB-500H ___ 1 - Power Head ___ 1 - Flex Pipe ___ 1 - Pipe w/swivel ___ 1 - Straight Pipe ___ 1 - Straight Pipe w/decal ___.
12 a s s e m b l y PB-500H W ARNING Never perform maintenance or assembly procedures with engine running or serious personal injury may result. I n s t a l l b l o w e r p I p e s / s t I c k h a n d l e 1. Assemble clamps (A) onto both ends of exible pipe (B).
13 P o w e r B l o w e r o P e r a t o r ' s M a n u a l G PB-500T W ARNING Never perform maintenance or assembly procedures with engine running or serious personal injury may result. I n s t a l l b l o w e r p I p e s ( t ) 1. Place guide loop (G) across clamp, and turn until clip fully engages clamp band.
14 NOTICE: Use of unmixed, improperly mixed, or fuel older than 90 days, (stale fuel), may cause hard starting, poor performance, or severe engine damage and void the product warranty . Read and follow instructions in the Storage section of this manual.
15 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Mixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline. 2. Add the proper amount of 2-stroke oil to gasoline. 3. Close container and shake to mix oil with gasoline.
16 s t a r t I n g c o l d e n g I n e • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for start - ing. Do not allow the rope to snap back in. Always hold the unit rmly . • (PB-500H): Rotate spring loaded throttle arm downward to a com - fortable operating position.
17 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s t a r t I n g w a r m e n g I n e The starting procedure is the same as Cold Start except DO NOT close the choke. PB-500H 1. Thr ottle Lever Move throttle position lever (A) midway between idle and full throttle positions.
18 o p e r a t I n g b l o w e r W ARNING Engine exhaust IS HOT , and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause unconsciousness, serious in- jury , or death. Exhaust can cause serious burns. AL W A YS position unit so that exhaust is directed away from your face and body .
19 P o w e r B l o w e r o P e r a t o r ' s M a n u a l m a I n t e n a n c e I n t e r v a l s m a I n t e n a n c e Y our ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help your blower achieve that goal.
20 a I r f I l t e r Level 1. T ools r equir ed: 25 - 50 mm (1 - 2 in.) cleaning brush. Parts r equir ed: Repower TM T une Up Kit NOTE Clean daily . 1. Close choke (Cold Start Position [ ]). This prevents dirt from entering the carburetor throat when the air lter is removed.
21 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s p a r k p l u g Level 1. T ools r equir ed: 3/4 in. Spark Plug deep socket, Feeler gauge Parts Requir ed: Repower TM T une Up Kit IMPOR T ANT Use only NGK BPM8Y spark plug (BPMR8Y in Canada) other - wise severe engine damage may occur .
22 e x h a u s t s y s t e m Spark Arrestor Screen Level 2. T ools r equir ed: Cross Head Screwdriver Parts Requir ed: Spark arrestor screen, Gasket IMPOR T ANT Carbon deposits in mufer will cause a drop in engine output and overheating. Spark arrestor screen must be checked periodically .
23 P o w e r B l o w e r o P e r a t o r ' s M a n u a l Exhaust Port Cleaning Level 2 T ools r equir ed: W ood or plastic scraper , Cross Head Screwdriver , 4 & 5mm Hex W rench Parts Requir ed: As needed: Mufer gasket 1. Remove spark plug lead from spark plug, and remove engine cover (5 screws).
24 c a r b u r e t o r a d j u s t m e n t Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the break- in period your engine performance will increase and exhaust emissions will stabilize.
25 P o w e r B l o w e r o P e r a t o r ' s M a n u a l DANGER Fuel vapors are extremely ammable and may cause re and/or explosion. Never test for ignition spark by ground- ing spark plug near cylinder plug hole, otherwise serious personal injury may result.
26 s t o r a g e W ARNING During operation the mufer or catalytic mufer and surrounding cover become hot. Always keep exhaust area clear of ammable debris during transportation or when storing, otherwise serious property damage or personal injury may result.
27 P o w e r B l o w e r o P e r a t o r ' s M a n u a l s p e c I f I c a t I o n s MODEL ---------------------------------------------------- PB-500H, PB-500T Length PB-500H ------------------------------------------ 380mm (15.0 in.) Length PB-500T ------------------------------------------- 328mm (12.
28 ECHO LIMITED W ARRANTY ST A TEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO'S RESPONSIBILITY ECHO Incorporated’s Limited W arranty , provides to the original purchaser that this ECHO product is free from de fects in material and workmanship .
29 P o w e r B l o w e r o P e r a t o r ' s M a n u a l PURCHASED REP AIR P ARTS, SHORT BLOCKS AND ACCESSORIES .
30 ECHO INCORPORA TED EMISSION CONTROL W ARRANTY ST A TEMENT FOR ECHO AND SHINDAIWA BRANDS The Environmental Protection Agency (EP A) and the California Air Resources Board (C.A.R.B.) and ECHO Incorporated (ECHO Inc.) are pleased to explain the emission control system warranty on your 2010 and later equipment/small of f-road engine (SORE).
31 P o w e r B l o w e r o P e r a t o r ' s M a n u a l n o t e s.
ECHO, INCORPORA TED 400 O a k w O O d R O a d L a k e Z u R i c h , iL 60047 www .echo-usa.com CONSUMER PRODUCT SUPPORT 1-800-673-1558 8:30 - 4:30 Mon - Fri C.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Echo PB-500T c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Echo PB-500T - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Echo PB-500T, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Echo PB-500T va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Echo PB-500T, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Echo PB-500T.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Echo PB-500T. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Echo PB-500T ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.