FR
Dimplex logo
Notice d'utilisation officielle

Dimplex DF2608

63 pages·2.3 MB·Cheminée d'intérieur·PDF·ENDEITNLJA
Dimplex DF2608
Table des matières 8 sections 7208680100R06_EN ·  Welcome & Congratulations ·  Important Instructions ·  Fireplace Installation · … AfficherMasquer
Page 1 of the Dimplex DF2608 user manual — 7208680100R06
Page 1 · cliquer pour agrandir
Page 1
Dimplex DF2608 — 7208680100R06_EN diagram (page 1)
Fig. 1
Dimplex DF2608 — 7208680100R06_EN diagram (page 1)
Fig. 2

Owner’s Manual

Model

DF2608 NBDF2608 DF2622SS DF2622BLK

7208680100R06

Page 2 of the Dimplex DF2608 user manual — Table of Contents
Page 2 · cliquer pour agrandir
Page 2

Table of Contents

Welcome & Congratulations 3

Fireplace Installation 7

Operation 11

Maintenance 13

Warranty 17

Replacement Parts 20

Always use a qualified technician or service agency to repair this stove.

! NOTE: Procedures and techniques that are considered important enough to emphasize.

Warning: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death.

Page 3 of the Dimplex DF2608 user manual — Welcome & Congratulations
Page 3 · cliquer pour agrandir
Page 3

Welcome & Congratulations

Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces.

Please carefully read and save these instructions.

Please record your model and serial numbers below for future reference: model and serial numbers can be found on the Model and Serial Number Label of your fireplace.

Dimplex DF2608 — Welcome & Congratulations diagram (page 3)
Fig. 3 · Welcome & Congratulations

OR Toll-Free 1-888-DIMPLEX (1-888-346-7539) Monday to Friday 8:00 a.m. to 4:30 p.m. EST Please have your model number and product serial number ready. (See above)

Page 4 of the Dimplex DF2608 user manual — Important Instructions
Page 4 · cliquer pour agrandir
Page 4

Important Instructions

① Read all instructions before using the electric fireplace.

⑨ Do not operate any unit with a damaged cord or plug, or if the heater has malfunctioned, or if the electric fireplace has been dropped or damaged in any manner. Contact Dimplex Technical Service 1-888-346- 7539.

② This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation.

⑩ Do not use outdoors.

③ Extreme caution is necessary when any heater is used by or near children or invalids and whenever the unit is left operating and unattended.

⑪ Never locate fireplace where it may fall into a bathtub or other water container.

④Young children should be supervised to ensure that they do not play with the appliance.

⑫ Do not install the fireplace directly on carpet or a similar surface which may restrict air circulation beneath the unit.

⑤The appliance is not intended for use by young children or infirmed persons without supervision.

⑬ Do not run the cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord away from traffic area and where it will not be tripped over.

⑥ The appliance must be positioned

so that the plug is accessible.

⑦ Always unplug the electric fireplace when not in use.

⑭ Do not locate the heater immediately below a fixed socket- outlet.

⑧If the supply cord is damaged, it must be replaced by the manufacturer, or its service agent, or a qualified person in order to avoid a hazard.

⑮ To disconnect the fireplace, turn the controls off, then remove the plug from the outlet.

Dimplex DF2608 — Important Instructions diagram (page 4)
Fig. 4 · Important Instructions
Page 5 of the Dimplex DF2608 user manual — SAVE THESE Instructions
Page 5 · cliquer pour agrandir
Page 5

Important Instructions

⑯ Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage to the heater.

⑳Avoid the use of an extension cord. Extension cords may overheat and cause a risk of fire. If you must use an extension cord, the cord shall be No. 14 AWG minimum size and rated not less then 1875 Watts.

⑰ Although this unit is of zero clearance design, to prevent a possible fire, do not block air intake or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.

㉑ Do not burn wood or other materials in the electric fireplace.

㉒ Do not strike the fireplace glass.

㉓ Always use a certified electrician should new circuits or outlets be required

⑱ All electrical heaters have hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint, or flammable liquids are used or stored or where the unit will be exposed to flammable vapors.

㉔ Always use properly grounded, fused and polarized outlets.

㉕ Disconnect all power supply before performing any cleaning, maintenance or relocation of the unit.

⑲ Do not modify the electric fireplace. Use it only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.

㉖ When transporting or storing the unit and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage.

SAVE THESE Instructions

Page 6 of the Dimplex DF2608 user manual — Important Instructions
Page 6 · cliquer pour agrandir
Page 6

Important Instructions

! NOTE: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Operation is subject to the following two conditions: (1) this device may not cause interference and; (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Reorient or relocate the receiving • antenna.

Increase the separation between • the equipment and the receiver.

Connect the equipment into an • outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an • experienced radio/TV technician for help.

Page 7 of the Dimplex DF2608 user manual — Fireplace Installation
Page 7 · cliquer pour agrandir
Page 7

Fireplace Installation

Fireplace Assembly The only assembly required is to slide the Front Glass onto the fireplace and install hardware to keep it in place.

cord is not installed so that it is pinched or against any sharp edges and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons. Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons. Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.

Remove fireplace and glass 1. carefully from the carton, discard the plastic bag and foam packaging. Remove the foam block from 2. within the fireplace (Figure 1). Using side cutters or scissors, 3. cut and remove the two (2) cable ties as shown in Figure 1 and remove the cardboard that protects the Log Set Assembly. Remove the right hand side 4. Trim by removing three (3) Phillips screws at the side of

Dimplex DF2608 — Fireplace Installation diagram (page 7)
Fig. 5 · Fireplace Installation
Page 8 of the Dimplex DF2608 user manual — Fireplace Installation
Page 8 · cliquer pour agrandir
Page 8

Fireplace Installation

the fireplace (Figure 2). Place the Front Glass onto 5. the track of the fireplace (Figure 2) and slide it along the front until it reaches the far left of the unit. Re-attach the right hand trim 6. piece using the three (3) Philips screws from step 4. Site Selection and Preparation This section provides instructions for selecting a location and preparing the site to install the fireplace into your Dimplex mantel surround.

the fireplace near an existing outlet (refer to NOTE 1). Store the fireplace in a safe 3. dry and dust free location.

air circulation beneath the fireplace is provided by two (2) spacers. Do not install fireplace directly on carpet or similar surfaces which may restrict air circulation. If installing the fireplace in a carpeted area, place a one- piece, solid flat surface under the fireplace. Ensure that all feet rest securely on this surface.

Select a suitable location that 1. is not susceptible to moisture and is away from drapes, furniture and high traffic. For ease of electrical hook 2. up you may wish to locate

! NOTEThe dimensions of

the fireplace with the trim are 27 ⅜ inch (695 mm) wide x 23 ½ inch (596 mm) high x 8 3/4 inch (222 mm) deep.

Dimplex DF2608 — Fireplace Installation diagram (page 8)
Fig. 6 · Fireplace Installation
Page 9 of the Dimplex DF2608 user manual — New Wall Construction
Page 9 · cliquer pour agrandir
Page 9

Fireplace Installation

New Wall Construction

Dimensions without trim are 26 ¼ inch (663 mm) wide x 22 ⅞ inch (580 mm) high x 8 ¾ inch (222 mm) deep. The fireplace does not require any additional venting (Figure 3).

Select a suitable location that 1. is not susceptible to moisture and is away from drapes, furniture and high traffic. Place the fireplace in the 2. desired location to see how it will look in the room. Mark the desired location on 3. the floor. Use studs to frame an 4. opening of 26 ¾ inch (679 mm) wide x 23 ⅛ inch (587 mm) high x 9 inch (229 mm) deep.

Fireplace Insert Installation Install the fireplace assembly into the mantel (refer to mantel assembly instructions).

! NOTE 1A 15 Amp, 120

Volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

Option #1The power cord can

be run from behind the Trim and along the wall to an outlet near the fireplace.

Dimplex DF2608 — New Wall Construction diagram (page 9)
Fig. 7 · New Wall Construction

a Dimplex mantel, the fireplace must be installed in an enclosure with the following MINIMUM dimensions (Figure 4).

Page 10 of the Dimplex DF2608 user manual — Existing Fireplace
Page 10 · cliquer pour agrandir
Page 10

Fireplace Installation

Option #2A new outlet can be

surfaces which may restrict air circulation. If installing the fireplace in a carpeted area, place a one-piece, solid, flat surface under the fireplace insert. Ensure that all feet rest securely on this surface.

installed inside the framing construction.

Plug the unit into a 15 Amp, 120 Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 Watts.

For Bathroom Use If this unit is installed in a bath room it must be protected by a GFI receptacle or circuit. If receptacle is used it must be readily accessible. To prevent electrical shock this unit is an electrical appliance that is not watertight and must be installed as to prevent water from entering unit. This must be installed away from showers, tubs, etc. Never locate fireplace where it may fall into a bathtub or other water con tainer. High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of this heater.

Existing Fireplace

Seal all drafts and vents 1. with a non-fibrous insulation material to prevent any chimney debris from falling onto the fireplace. Do not install into an existing fireplace that is prone to dampness. Cap the top of the chimney 2. flue to prevent rain from entering. Plan your electric power 3. supply. The power cord can run along 4. the front of the hearth to an outlet near the fireplace.

air circulation beneath the fireplace insert is provided by two (2) spacers. Do not install the fireplace insert directly on carpet or similar

Page 11 of the Dimplex DF2608 user manual — Operation
Page 11 · cliquer pour agrandir
Page 11

Operation

Dimplex DF2608 — Operation diagram (page 11)
Fig. 8 · Operation

Electric Fireplace Manual Controls (Figure 5) The manual controls for the fireplace are behind the access panel located at the bottom of the fireplace.

C. Light Dimmer Control Turn the Light Dimmer Control knob to increase or decrease the brightness of the interior of the fireplace.

D. Heater On/Off Switch The Heater On/Off Switch supplies power to the heating unit when the Three Position On/ Off Switch (A) is on (“ I ” or “ II ” positions).

A. Three Position On/Off Switch The switch has two (2) on positions marked with “ I ” and “ II ”. The “ I ” position is for manual operation. In this position the built-in remote control is bypassed. The “ II ” position is for operating the unit with the provided remote control. When in “ II ” position the unit is operated with the ON and OFF buttons of the remote control. When the switch is in the center “ O ” position the unit is off.

E. Heater Thermostat Control To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at its setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on.

B. Flame Action Control

Turn the Flame Action Control knob to adjust the flame speed to the desired level.

Page 12 of the Dimplex DF2608 user manual — Operation
Page 12 · cliquer pour agrandir
Page 12

Operation

To turn the heater off, rotate the knob fully counter clockwise.

Three Position On/Off Switch on the fireplace is set to the remote control setting (“ II ”position). To operate, push the ON button to turn the fireplace on, push the OFF button to turn the fireplace off.

Resetting the Temperature Cutoff Switch This unit is equipped with a thermostat which controls the temperature of the room by turning the heater on and off. The heater is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Three Position On/Off Switch to Off and waiting five (5) minutes before switching the unit back on.

  • Battery Replacement (Figure 6) To replace the battery:
  • Slide battery cover open on the hand held transmitter.
  • Correctly install one (1) 12 Volt (A23) battery in the battery holder.
  • Close the battery cover.

Remote Initialization/ Reprogramming Follow these steps for remote control initialization and if required, re-initialization:

continuously reset the heater, unplug the unit and call Technical Support at 1-888- 346-7539. Please have your model and serial number ready when calling.

Disconnect power to 1. fireplace. Set the Three Position On/Off 2. Switch to the Remote position (Figure 5A). Wait a minimum of five (5) 3. seconds and then re-acquire power to fireplace. Within 4. 10 seconds of re- acquiring power, press the

Remote Control (Figure 6) The fireplace is supplied with an integrated on/off remote control.

! NoteEnsure that the
Page 13 of the Dimplex DF2608 user manual — Operation
Page 13 · cliquer pour agrandir
Page 13

Operation

Dimplex DF2608 — Operation diagram (page 13)
Fig. 9 · Operation

seconds to perform this last step. Failure to do so will result in these steps needing to be followed again.

This will synchronize the remote control transmitter and receiver.

flames and embers, and two (2) bulbs above that illuminate the log exterior.

before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.

Lower Light Bulb Requirements Quantity of three (3) clear chan delier or candelabra bulbs with an E-12 (small) socket base, 60 Watt rating. Example: GE 60BC or Philips 60CTC. Do not exceed 60 Watts per bulb.

Light Bulb Replacement Allow at least five (5) minutes for the light bulbs to cool before touching them to avoid accidental burning of the skin. The light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log ember bed exterior reduces. There are three (3) bulbs under the Log Set Assembly, which generate the

Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce

Page 14 of the Dimplex DF2608 user manual — Maintenance
Page 14 · cliquer pour agrandir
Page 14

Maintenance

Dimplex DF2608 — Maintenance diagram (page 14)
Fig. 10 · Maintenance

the number of times you need to open the unit to replace light bulbs. Care must be taken when removing the Log set assembly as it contains LED’s and wires (DF2608 only).

the log set assembly by the ember bed or plastic grate.

! NOTE: Log set assembly fits tightly into firebox, some force may be necessary to remove.

Slide fireplace out of mantel. 1. Lay unit on it’s back for safe 2. removal of front glass. Remove three (3) Phillips 3. screws from the right side of trim. Remove trim. 4. Slide glass to right side of 5. fireplace to remove (Figure 7). Pull the front edge of the 6. plastic ember bed or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the mirror (Figure 8).

Set log set assembly in front 7. of fireplace. Remove flicker rod by pulling 8. rod to the right, towards the flicker motor. Bend the flicker rod enough to clear the bracket on the left, lift out and pull flicker rod off of flicker motor shaft (Figure 9). Remove four (4) Phillips 9. screws (two (2) per side) which attach light filter bracket for easier access to light bulbs (Figure 9). Unscrew bulbs counter 10. clockwise to remove. Insert new bulbs and screw in 11.

! IMPORTANTOnly handle
Page 15 of the Dimplex DF2608 user manual — Maintenance
Page 15 · cliquer pour agrandir
Page 15

Maintenance

clockwise. Replace light filter bracket 12. and flicker rod. Install the log set assembly by 13. placing the front, bottom edge of the ember bed in the track behind the control panel. Once in place, push down on the back edge of the ember bed until the rear tab snaps into place under the mirror (Figure 8).

and attach trim.

Upper Light Bulb Requirements Quantity of two (2) clear chandelier or candelabra bulbs with an E-12 (small) socket base, 15 Watt rating. Do not exceed 25 Watts per bulb.

To access the upper light bulb area:

Slide fireplace out of mantel. 1. Lay unit on it’s back for safe 2. removal of front glass. Remove three (3) Phillips 3. screws from right side of trim. Remove trim. 4. Slide glass to the right side 5.

! NOTE: Ensure the log set Assembly is installed tightly under the bottom edge of the mirror to prevent light leakage.

Lay unit on it’s back and slide 14. Front Glass back into position

Dimplex DF2608 — Maintenance diagram (page 15)
Fig. 11 · Maintenance
Page 16 of the Dimplex DF2608 user manual — Maintenance
Page 16 · cliquer pour agrandir
Page 16

Maintenance

Glass Cleaning The glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the clear door may collect dust particles, these can be removed by dusting lightly with a clean dry cloth. To remove fingerprints or other marks, the clear door can be cleaned with a damp cloth.

of the fireplace to remove (Figure 7). Upper bulbs are located in 6. the upper left and upper right corners of fireplace, behind the light block bracket (Figure 9). Remove the four (4) Phillips 7. screws that attach the light block to the firebox (Figure 9). Unscrew bulbs counter 8. clockwise. Insert new bulbs and screw in 9. clockwise. Re-attach light block bracket. 10. Lay unit on it’s back, slide 11. front glass back into position and attach Trim.

Fireplace Surface Clean ing Use a cloth dampened with warm water only to clean painted sur faces of the electric fireplace. Do not use abrasive cleaners.

Page 17 of the Dimplex DF2608 user manual — Warranty
Page 17 · cliquer pour agrandir
Page 17

Warranty

Two Year Limited Warranty

defects in material and workmanship for a period of 2 years from the date of the first purchase of such products as follows: (a) a repair or replacement warranty on defective products or parts, including in-home services, for the first year following the date of first purchase; and (b) thereafter, a replacement of parts warranty on defective products and parts (with no in-home services) for the 1 year period commencing on the first anniversary of first purchase and ending on the second anniversary of the date of first purchase.

Products to which this limited warranty applies

This limited warranty applies to your newly purchased Dimplex electric fireplace. This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA (and the District of Columbia) except for Hawaii and Alaska. This limited warranty applies to the original purchaser of the product only and is not transferable.

Dimplex fireplace surrounds (mantels) and trims covered by this limited warranty have been tested and inspected prior to shipment and, subject to the provisions of this warranty, Dimplex warrants such products to be free from defects in material and workmanship for a period of 1 year from the date of first purchase of such products. Warranty services do not include in-home services.

Products excluded from this limited warranty

Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner/purchaser. Products purchased in Yukon Territory, Nunavut, Northwest Territories, Hawaii, or Alaska are not covered by this limited warranty. Products purchased in these States, provinces, or territories are sold AS IS without warranty or condition of any kind (including, without limitation, any implied warranties or conditions of merchantability or fitness for a particular purpose) and the entire risk of as to the quality and performance of the products is with the purchaser, and in the event of a defect the purchaser assumes the entire cost of all necessary servicing or repair.

The limited 2 year warranty period for products other than fireplace surrounds (mantels) and trims and the limited 1 year warranty period for fireplace surrounds (mantels) and trims also applies to any implied warranties that may exist under applicable law. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to the purchaser.

What this limited warranty does not cover

What this limited warranty covers and for how long

This limited warranty does not apply to products that have been repaired (except by Dimplex or its authorized service representatives) or otherwise altered. This limited warranty does further not apply to defects resulting from misuse, abuse, accident, neglect, incorrect installation, improper maintenance or handling, or

Products, other than fireplace surrounds (mantels) and trims, covered by this limited warranty have been tested and inspected prior to shipment. Subject to the provisions of this warranty, Dimplex warrants such products to be free from

Page 18 of the Dimplex DF2608 user manual — Warranty
Page 18 · cliquer pour agrandir
Page 18

Warranty

operation with an incorrect power source.

refund the purchase price for such product or part. This limited warranty entitles the purchaser to on-site or in- home warranty services. Accordingly, Dimplex will be responsible for all labour and transportation costs associated with the repair or replacement of the product or part except as follows: (i) charges may be levied for travel costs incurred to travel to the purchaser’s site where the product is located if the purchaser’s site is beyond 30 miles (48 km) from the closest service depot of Dimplex’s dealer or service agent; and (ii) the purchaser is solely responsible for providing clear access to all serviceable parts of the product.

What you must do to get service under this limited warranty

Defects must be brought to the attention of Dimplex Technical Service by contacting Dimplex at 1-888-DIMPLEX (1-888- 346-7539), or 1367 Industrial Road, Cambridge Ontario, Canada N1R 7G8. Please have proof of purchase, catalogue/ model and serial numbers available when calling. Limited warranty service requires a proof of purchase of the product.

What Dimplex will do in the event of a defect

In the event a product or part covered by this limited warranty is proven to be defective in material or workmanship during (i) the 2 year limited warranty period for products other than fireplace surrounds (mantels) and trims, and (ii) the 1 year limited warranty period for surrounds (mantels) and trims, you have the following rights:

For products (other than surrounds • (mantels) and trims) for the period commencing at 12:01 a.m. on the day after the first anniversary of the first purchase and ending at midnight on the second anniversary of the date of first purchase, this limited warranty entitles the purchaser to replacement parts only without charge. If Dimplex is unable to replace such part, or if replacement is not commercially practicable or cannot be timely made, Dimplex may, in lieu of replacement, choose to refund the purchase price for such part. The purchaser shall not be entitled to on-site or in-home warranty services. The purchaser shall be responsible for all expenses incurred for the removal of the part and installation of the replacement part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s place of business and all labour

  • Limited warranty service will be performed solely by dealers or service agents of Dimplex authorized to provide limited warranty services.

For products (other than surrounds • (mantels) and trims) for the period ending at midnight on the first anniversary of the date of first purchase, Dimplex will in its sole discretion either repair or replace such defective product or part without charge. If Dimplex is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or replacement, choose to

Page 19 of the Dimplex DF2608 user manual — Warranty
Page 19 · cliquer pour agrandir
Page 19

Warranty

costs. Such costs shall not be the responsibility of Dimplex.

CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE, MAINTENANCE, USE, OR INABILITY TO USE THE PRODUCT, EVEN IF DIMPLEX OR ITS DIRECTORS, OFFICERS, OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE. IN NO EVENT WILL DIMPLEX, OR ITS OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES, COSTS, OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT.

For surrounds (mantels) and trims • for the period ending at midnight on the first anniversary of the date of first purchase, Dimplex will in its sole discretion either repair or replace such defective surrounds (mantels) and trims or part thereof without charge. If Dimplex is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. The purchaser shall not be entitled to on-site or in-house services. The purchaser is responsible for all expenses incurred for repair or replacement of such product or part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s business and all labour costs. Such costs shall not be the responsibility of Dimplex.

SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER.

How State and Provincial law apply

This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction. The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty.

On-site or in-home services not • provided under this warranty may be performed at the purchaser’s specific request and expense at Dimplex’s then-current rates for such services.

What Dimplex and its dealers and service agents are also not responsible for:

IN NO EVENT WILL DIMPLEX, OR ITS DIRECTORS, OFFICERS, OR AGENTS, BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY. WHETHER IN CONTRACT, IN TORT, OR ON ANY OTHER BASIS, FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY,

Page 20 of the Dimplex DF2608 user manual — Replacement Parts
Page 20 · cliquer pour agrandir
Page 20

Replacement Parts

Log Set 0439560100RP

Flicker Motor 3000240200KIT

Heater Assembly (Built-in Cutout) 2000330100RP

Thermostat 2300150100RP

Main On/Off Switch 2800071100RP

Manual Heat Selection Switch 2800070700RP

Flame Action Control with Potentiometer 3000240500RP

Light Dimmer Control with Potentiometer 3000250100RP

Cord Set 4100040200RP

Single Lamp Holder (Center Lower) 2500150300RP

Double Lamp Holder (Upper and Lower) 2500400300RP

Mirror 5901210200RP

Front Glass 5901220100RP

Control Knob 8800000200RP

Remote Transmitter 3000370500RP

Remote Reciever 3000380200RP

Terminal Block 4000070100RP

Flicker Rod 5901250100RP

Trim Replacement Kit 9600260100RP

Dimplex DF2608 — Replacement Parts diagram (page 20)
Fig. 12 · Replacement Parts

Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8

© 2011 Dimplex North America Limited

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Dimplex DF2608

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Dimplex DF2608

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Dimplex DF2608 manuel PDF

63 pages·2.3 MB·Cheminée d'intérieur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…