DWFP12658 ROOFING COIL NAILER CLOUEUSE POUR TOITURE À CLOUS EN BOBINE CLAVADORA PARA TECHADO A RESORTE

INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
INSTRUCTIONS DE FONCTIONNEMENT, CENTRES DE SERVICE, POLITIQUE DE GARANTIE. AVERTISSEMENT : LISEZ CES INSTRUCTIONS AVANT D'UTILISER L'APPAREIL.
If you have questions or comments, contact us. Pour toute question ou tout commentaire, nous contacter.
Si tiene dudas o comentarios, contáctenos.
1-800-4-DeWALT • www.dewalt.com

FOR PNEUMATIC TOOLS
SAVE THESE INSTRUCTIONS
DEFINITIONS - SAFETY GUIDELINES The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.
Fig. A

Fig. C
4.9 bar
Fig. D
70 psi


Fig. G
Fig. H




Fig. P



A. Exhaust deflector B. Selectable trigger C. Air Inlet with quick
connect coupler D. Canister E. Door latch F. Contact tip G. Depth adjustment wheel H. Door I. Tool-Free Shingle Guide J. Trigger lock button k. Mode selector button
G
D
F
E H

WARNING: Keep fingers AWAY from the trigger when not driving fasteners to avoid accidental actuation. Never carry a tool with finger on the trigger. In bump action mode (contact actuation mode), the tool will drive a fastener if the contact trip is bumped while the trigger is depressed. The DWFP12658 is equipped with a selectable trigger. This trigger allows the operator to select either single sequential action trigger mode or bump action trigger mode. In accordance with the ANSI Standard SNT-101-2002, the trigger is assembled in the single sequential action trigger mode. To change the trigger mode, see Actuating Tool instructions in the Operation section of the manual. The selectable trigger also has a trigger lock button to keep the trigger locked at all times when the tool is not in use.
AIR FITTING The tool is equipped with a 1/4" (6.4 mm) male quick connector coupling. A 3/8" (9.5 mm) male quick connector coupling is available from DeWALT and may be used when a 1/4" (6.4 mm) supply line is not available. NOTE: A 3/8" (9.5 mm) supply line (and fittings) are required for maximum tool performance.
To install an air fitting 1. Wrap the male end of the fitting with thread seal tape prior to assembly to eliminate air leaks. 2. To install a 1/4" (6.4 mm) fitting: screw it directly into the air inlet and tighten firmly. NOTE: If an adapter is in the air inlet, remove it prior to inserting the fitting. 3. To install a 3/8" (9.5 mm) fitting: screw the fitting into the 3/8" (9.5 mm) adapter and then into the air inlet of the tool and tighten firmly.
WARNING: Read the section titled Important Safety Instructions for Pneumatic Tools at the beginning of this manual. Always wear eye and ear protection when operating this tool. Keep the nailer pointed away from yourself and others. For safe operation, complete the following procedures and checks before each use of the nailer. NOTICE: To reduce the risk of damage to the tool, only use DeWALT pneumatic tool oil or a non-detergent SAE 20 weight oil. Oil with additives or detergent will damage tool parts. 1. Before you use the nailer, be sure that the compressor tanks have been properly drained. 2. Lubricate tool:

a. Use DeWALT pneumatic tool oil or a non-detergent S.A.E. 20 weight oil. DO NOT use detergent oil or additives as they will damage O-rings and rubber parts. b. Use a filter when possible. c. Add 5 to 7 drops of oil in the air fitting a least twice a day. 3. Wear eye and ear protection. 4. Ensure canister is empty of all fasteners. 5. Check for smooth and proper operation of contact trip. Do not use tool if assembly is not functioning properly. NEVER tamper with the contact trip. NEVER use a tool that has the contact trip restrained in the actuated position. 6. Adjust air supply: Ensure air pressure does not exceed recommended operating limits; 70 to 120 psi, (4.9 to 8.3 bar, 5 to 8.5 kg/cm2). 7. Keep tool pointed away from yourself and others. 8. Connect air hose. 9. Check for audible leaks around valves and gaskets. Never use a tool that leaks or has damaged parts. WARNING: To reduce the risk of personal injury, disconnect tool from air supply and engage trigger lock before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location or handing the tool to another person. LOADING THE TOOL (FIG. 1–6)
WARNING: Never load nails with the contact trip or trigger activated. Personal injury may result. 1. Read all Safety Warnings before using tool. 2. Connect the air supply to the tool. 3. Lift the canister door latch (E) to open the nail guide door (H). 4. Rotate the canister door (I) open. 5. Adjust the nail platform (J) to properly accommodate the nail length being used. Pull the nail platform (J) up or down for desired nail.

H I


Fig. 3 J



M
E
Single Sequential actuation trigger mode - (Fig. 7) WARNING: Allow the tool to recoil off the work surface after actuation. If the contact trip remains depressed a nail will be driven each time the trigger is released and pulled, which could result in accidental actuation, possibly causing injury. The sequential actuation trigger’s intended use is for intermittent fastening where accurate fastener placement is desired.

To operate the tool in Single sequential actuation mode: 1. Depress the contact trip firmly against the work surface. 2. Pull the trigger. 3. Allow the tool to recoil from the work surface.
Trigger mode selector button
Trigger lock button

Contact actuation trigger mode - (Fig. 8) The contact actuation trigger is intended for rapid fastening on flat, stationary surfaces. Using the contact actuation trigger mode, two methods are available: place actuation and contact actuation.

To operate the tool using the PLACE ACTUATION method: 1. Depress the contact trip against the work surface. 2. Pull the trigger to drive the fastener. 3. Allow the tool to recoil off the work surface
Trigger mode selector button
To operate the tool using the CONTACT ACTUATION method: 1. Pull the trigger. 2. Depress the contact trip against the work surface. As long as the trigger is pulled, the tool will drive a fastener every time the contact trip is depressed. This allows the user to rapidly drive multiple fastener in sequence.

Trigger lock button



O
O
Q
R
SHINGLE GUIDE (FIG. 11, 12) Adjust shingle guide (O): 1. Loosen the adjusting lever (P) and slide the locking plate to desired position. 2. Tighten adjusting lever firmly.
The locking plate (O) can be used as an aid to position the shingle being nailed a specific distance (Q) from the front edge of the previous row of shingles (R) as shown.
WARNING: Disconnect air line from tool, engage trigger lock and remove fasteners from magazine before making adjustments or personal injury may result. If a nail becomes jammed in the nosepiece, keep the tool pointed away from you and follow these instructions to clear: 1. Disconnect the air supply from the tool. 2. Lift the canister door latch (E) to open the nail guide door (H). 3. Open the canister door. 4. Remove the jammed nail. 5. Correct any deformation that may have occurred to the nail coil. NOTE: Should nails continue to jam frequently in nosepiece, have tool serviced by an authorized DeWALT service center.

COLD WEATHER OPERATION When operating tools at temperatures below freezing: 1. Make sure compressor tanks have been properly drained prior to use. 2. Keep tool as warm as possible prior to use. 3. Make certain all fasteners have been removed from canister. 4. Put 5 to 7 drops of DeWALT pneumatic tool oil in the air inlet. 5. Lower air pressure to 80 psi (5.5 bar) or less. 6. Reconnect air and load nails into canister. 7. Actuate the tool 5 or 6 times into scrap lumber to lubricate O-rings. 8. Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal. 9. Re-lubricate at least once daily. 10. Always drain the compressor tanks at least once a day.

HOT WEATHER OPERATION Tool should operate normally. However, keep tool out of direct sunlight as excessive heat can deteriorate bumpers, O-rings and other rubber parts resulting in increased maintenance.
REPAIRS To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DeWALT factory service center, a DeWALT authorized service center or other qualified service personnel. Always use identical replacement parts. Refer to the Troubleshooting Guide at the end of this section.

Recommended accessories for use with your tool are available at extra cost from your local dealer or authorized service center. If you need assistance in locating any accessory, please contact DeWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286, call 1-800-4-DeWALT (1-800-433-9258) or visit our website www.dewalt.com
DeWALT will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www.dewalt.com or call 1-800-4-DeWALT (1-800-433-9258). This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces. In addition to the warranty, DeWALT tools are covered by our: 1 YEAR FREE SERVICE: DeWALT will maintain the tool and replace worn parts caused by normal use, for free, any time during the first year after purchase. Nailer wear items, such as o-rings and driver blades, are not covered. 90 DAY MONEY BACK GUARANTEE: If you are not completely satisfied with the performance of your DeWALT Power Tool, Laser, or Nailer for any reason, you can return it within 90 days from the date of purchase with a receipt for a full refund – no questions asked. LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained in the packaging, call the local company or see website for warranty information.


TROUBLESHOOTING GUIDE MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE CHART BELOW. FOR MORE SERIOUS OR PERSISTENT PROBLEMS, CONTACT A DeWALT SERVICE CENTER OR CALL 1-(800)-4-DeWALT (1-800-433-9258).
SYMPTOM PROBLEMS SOLUTIONS Air leak near top of tool or in trigger area
Loose screws. Tighten screws. Worn or damaged o-rings or seals.
Install Overhaul Kit.
Tool does nothing or operates sluggishly
Inadequate air supply. Verify adequate air supply. Inadequate lubrication. Put 5 or 7 drops of oil into air inlet. Worn or damaged o-rings or seals.
Install Overhaul Kit.
Air leak near bottom of tool
Loose screws. Tighten screws. Worn or damaged o-rings or bumper.
Install Overhaul Kit.
Tool jams frequently Incorrect fasteners. Verify approved fasteners of correct size and 15° collation angle. Damaged fasteners. Bent collation wire.
Replace with undamaged fasteners. Canister or nose screws loose Tighten screws. Canister is dirty. Clean magazine. Driver tip is worn or damaged. Install Driver Maintenance Kit. Other Contact a DeWALT Authorized Warranty Service Center
DWFP12658
Height (inch/mm) 10.5/ 266
Width (inch/mm) 4.3/ 110
Length (inch/mm) 10.3/ 262
Weight (lbs/kg) 4.91/ 2.23
Recommended Operating Pressure 70-120 psi (4.8 to 8.3 bar) Air Consumption per 100 cycles 4.13 CFM Loading capacity 120 nails


Compressor will be sufficient for tools at all production rates.
Compressor will be sufficient at slow or moderate production rates, but may have difficulty at very rapid rates.
Compressor will be adequate only when tools are utilized at slow production rates (punch-out or occasional use).