FR
DeWalt logo
Notice d'utilisation officielle

DeWalt DWFP12658

48 pages·7.3 MB·Cloueuse·PDF·ENDEITNLJA
DeWalt DWFP12658
Table des matières 26 sections INSTRUCTION MANUAL GUIDE D’UTILISATION MANUAL DE INSTRUCCIONES · 9R199590RA · IMPORTANT SAFETY INSTRUCTIONS · FOR PNEUMATIC TOOLS · … AfficherMasquer
Page 1 of the DeWalt DWFP12658 user manual — 9R199590RA
Page 1 · cliquer pour agrandir
Page 1

DWFP12658 ROOFING COIL NAILER CLOUEUSE POUR TOITURE À CLOUS EN BOBINE CLAVADORA PARA TECHADO A RESORTE

DeWalt DWFP12658 — INSTRUCTION MANUAL GUIDE D’UTILISATION MANUAL DE INSTRUCCIONES diagram (page 1)
Fig. 1

INSTRUCTION MANUAL GUIDE D’UTILISATION MANUAL DE INSTRUCCIONES

INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO.

INSTRUCTIONS DE FONCTIONNEMENT, CENTRES DE SERVICE, POLITIQUE DE GARANTIE. AVERTISSEMENT : LISEZ CES INSTRUCTIONS AVANT D'UTILISER L'APPAREIL.

If you have questions or comments, contact us. Pour toute question ou tout commentaire, nous contacter.

Si tiene dudas o comentarios, contáctenos.

1-800-4-DeWALT • www.dewalt.com

9R199590RA

Page 2 of the DeWalt DWFP12658 user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 2 · cliquer pour agrandir
Page 2

IMPORTANT SAFETY INSTRUCTIONS

FOR PNEUMATIC TOOLS

SAVE THESE INSTRUCTIONS

DEFINITIONS - SAFETY GUIDELINES The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols.

  • Actuating tool may result in flying debris, collation material, or dust which could harm operator’s eyes. Operator and others in work area MUST wear safety glasses with side shields. These safety glasses must conform to ANSI Z87.1 requirements (approved glasses have “Z87” printed or stamped on them). It is the employer’s responsibility to enforce the use of eye protection equipment by the tool operator and other people in the work area. (Fig. A)
  • Always wear appropriate personal hearing and other protection during use. Under some conditions and duration of use, noise from this product may contribute to hearing loss. (Fig. A)
  • Use only clean, dry, regulated air. Condensation from an air compressor can rust and damage the internal workings of the tool. (Fig. B)
  • Regulate air pressure. Use air pressure compatible with ratings on the nameplate of the tool. [Not to exceed 120 psi (8.3 bar).] Do not connect the tool to a compressor rated at over 200 psi. The tool operating pressure must never exceed 200 psi even in the event of regulator failure. (Fig. C)
  • Only use an air hose that is rated for a maximum working pressure of at least 150 psi (10.3 bar) or 150% of the maximum system pressure, whichever is greater. (Fig. D)
  • Do not use bottled gases to power this tool. Bottled compressed gases such as oxygen, carbon dioxide, nitrogen, hydrogen, propane, acetylene or air are not

Fig. A

DeWalt DWFP12658 — IMPORTANT SAFETY INSTRUCTIONS diagram (page 2)
Fig. 2

Fig. C

4.9 bar

Fig. D

70 psi

Page 3 of the DeWalt DWFP12658 user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 3 · cliquer pour agrandir
Page 3
  • for use with pneumatic tools. Never use combustible gases or any other reactive gas as a power source for this tool. Danger of explosion and/or serious personal injury may result. (Fig. E)
  • Use couplings that relieve all pressure from the tool when it is disconnected from the power supply. Use hose connectors that shut off air supply from compressor when the tool is disconnected. (Fig. F)
  • Disconnect tool from air supply when not in use. Always disconnect tool from air supply and remove fasteners from magazine before leaving the area or passing the tool to another operator. Do not carry tool to another work area in which changing location involves the use of scaffoldings, stairs, ladders, and the like, with air supply connected. Do not make adjustments, remove magazine, perform maintenance or clear jammed fasteners while connected to the air supply. If the contact trip is adjusted when the tool is connected to the air supply and nails are loaded, accidental discharge may occur. (Fig. G)
  • Connect tool to air supply before loading fasteners to prevent an unintentional fastener discharge during connection. The tool driving mechanism may cycle when the tool is connected to the air supply. Do not load fasteners with the trigger or the contact trip depressed to prevent unintentional driving.
  • Do not remove, tamper with, or otherwise cause the tool, trigger, or contact trip to become inoperable. Do not tape or tie trigger or contact trip in the on position. Do not remove spring from contact trip. Make daily inspections for free movement of trigger and contact trip. Uncontrolled discharge could result.
  • Inspect tool before use. Do not operate a tool if any portion of the tool, trigger, or contact trip is inoperable, disconnected, altered, or not working properly. Leaking air, damaged parts or missing parts should be repaired or replaced before use. Refer to Repairs. (Fig. H)
  • Do not alter or modify the tool in any way. (Fig. I)
  • Always assume that the tool contains fasteners.
  • Do not point the tool at co-workers or yourself at any time. No horseplay! Work safe! Respect the tool as a working implement. (Fig. J)
  • Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control. When tool is not in use, it should be locked in a safe place, out of the reach of children.
  • Remove finger from trigger when not driving fasteners.
  • Never carry tool with finger on trigger. Accidental discharge could result. Using the trigger lock-off will prevent accidental discharge.
DeWalt DWFP12658 — IMPORTANT SAFETY INSTRUCTIONS diagram (page 3)
Fig. 3

Fig. G

Fig. H

DeWalt DWFP12658 — IMPORTANT SAFETY INSTRUCTIONS diagram (page 3)
Fig. 4
Page 4 of the DeWalt DWFP12658 user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 4 · cliquer pour agrandir
Page 4
  • Do not overreach. Maintain proper footing and balance at all times. Loss of balance may cause personal injury. (Fig. K)
  • Make sure hose is free of obstructions or snags. Entangled or snarled hoses can cause loss of balance or footing.
  • Use the tool only for its intended use. Do not discharge fasteners into open air, concrete, stone, extremely hard woods, knots or any material too hard for the fastener to penetrate. Do not use the body of the tool or top cap as a hammer. Discharged fasteners may follow unex pected path and cause injury. (Fig. L)
  • Always keep fingers clear of contact trip to prevent injury from inadvertent release of nails. (Fig. M)
  • Refer to the Maintenance and Repairs sections for detailed information on the proper maintenance of the tool.
  • Always operate the tool in a clean, lighted area. Be sure the work surface is clear of any debris and be careful not to lose footing when working in elevated environments such as rooftops.
  • Do not drive fasteners near edge of material. The workpiece may split causing the fastener to ricochet, injuring you or a co-worker. Be aware that the nail may follow the grain of the wood (shiner), causing it to protrude unexpectedly from the side of the work material. Drive the nail perpendicular to the grain to reduce risk of injury. (Fig. N)
  • Do not drive nails onto the heads of other fasteners or with the tool at too steep an angle. Personal injury from strong recoil, jammed fasteners, or ricocheted nails may result. (Fig. O)
  • Be aware of material thickness when using the nailer. A protruding nail may cause injury.
  • Be aware that when the tool is being utilized at pressures on the high end of its operating range, nails can be driven completely through thin or very soft work material. Make sure the pressure in the compressor is set so that nails are set into the material and not pushed completely through. (Fig. P)
  • Keep hands and body parts clear of immediate work area. Hold workpiece with clamps when necessary to keep hands and body out of potential harm. Be sure the workpiece is properly secured before pressing the nailer against the material. The contact trip may cause the work material to shift unexpectedly. (Fig. Q)
  • Do not use tool in the presence of flammable dust, gases or fumes. The tool may produce a spark that could ignite gases causing a fire. Driving a nail into another nail may also cause a spark. (Fig. R)
  • Keep face and body parts away from back of the tool
DeWalt DWFP12658 — IMPORTANT SAFETY INSTRUCTIONS diagram (page 4)
Fig. 5
Page 5 of the DeWalt DWFP12658 user manual — SEQUENTIAL ACTION TRIGGER MODE
Page 5 · cliquer pour agrandir
Page 5
  • cap when working in restricted areas. Sudden recoil can result in impact to the body, especially when nailing into hard or dense material. (Fig. S)
  • Grip tool firmly to maintain control while allowing tool to recoil away from work surface as fastener is driven. In bump action mode (contact actuation mode) If contact trip is allowed to recontact work surface before trigger is released an unwanted fastener will be driven.
  • Choice of triggering method is important. Check the manual for triggering options.

Fig. P

DeWalt DWFP12658 — BUMP OR CONTACT ACTUATION TRIGGER MODE diagram (page 5)
Fig. 6

BUMP OR CONTACT ACTUATION TRIGGER MODE

  • When using the bump action trigger mode, be careful of unintentional double fires resulting from tool recoil. Unwanted fasteners may be driven if the contact trip is allowed to accidentally re-contact the work surface. (Fig. T) TO AVOID DOUBLE FIRES:
  • Do not engage the tool against the work surface with a strong force.
  • Allow the tool to recoil fully after each actuation.
  • Use sequential action trigger mode.
  • When bump actuating the nailer, always keep tool in control. Inaccurate placement of tool can result in misdirected discharge of a fastener.

SEQUENTIAL ACTION TRIGGER MODE

  • When using the sequential action trigger mode, do not actuate the tool unless the tool is placed firmly against the workpiece.
  • DEPTH ADJUSTMENT: To reduce risk of serious injury from accidental actuation when attempting to adjust depth, ALWAYS:
  • Disconnect air supply.
  • Engage trigger lock
  • Avoid contact with trigger during adjustments.
  • Do not drive nails blindly into walls, floors or other work areas. Fasteners driven into live electrical wires, plumbing, or other types of obstructions can result in injury. (Fig. U)
  • Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use tool while tired or under the influence of drugs or alcohol. A moment of inattention while operating power tools may result in serious personal injury. WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to the Sate of Califomia to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
Page 6 of the DeWalt DWFP12658 user manual — J K
Page 6 · cliquer pour agrandir
Page 6
  • Lead from lead-based paints
  • Crystalline silica from bricks and cement and other masonry products
  • Arsenic and chromium from chemically-treated lumber. Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles.
  • ANSI Z87.1 eye protection (CAN/CSA Z94.3),
  • ANSI S12.6 (S3.19) hearing protection,
  • NIOSH/OSHA respiratory protection. Before operating this tool, carefully read and understand all instructions in Important Safety Instructions .
NAIL SPECIFICATIONS DWFP12658 Nails0.120" (3 mm) diameter, 15º wire collated roofing nails Lengths3/4" (19 mm) - 1-3/4" (44.5 mm) Air Inlet1/4" NPT (6.4 mm) NOTE: Use only DeWALT approved fasteners

TOOL PARTS

DeWalt DWFP12658 — TOOL PARTS diagram (page 6)
Fig. 7

A

A. Exhaust deflector B. Selectable trigger C. Air Inlet with quick

C B

connect coupler D. Canister E. Door latch F. Contact tip G. Depth adjustment wheel H. Door I. Tool-Free Shingle Guide J. Trigger lock button k. Mode selector button

J K

G

D

F

E H

Page 7 of the DeWalt DWFP12658 user manual — PREPARING THE TOOL
Page 7 · cliquer pour agrandir
Page 7

ASSEMBLY

TRIGGER

WARNING: Keep fingers AWAY from the trigger when not driving fasteners to avoid accidental actuation. Never carry a tool with finger on the trigger. In bump action mode (contact actuation mode), the tool will drive a fastener if the contact trip is bumped while the trigger is depressed. The DWFP12658 is equipped with a selectable trigger. This trigger allows the operator to select either single sequential action trigger mode or bump action trigger mode. In accordance with the ANSI Standard SNT-101-2002, the trigger is assembled in the single sequential action trigger mode. To change the trigger mode, see Actuating Tool instructions in the Operation section of the manual. The selectable trigger also has a trigger lock button to keep the trigger locked at all times when the tool is not in use.

AIR FITTING The tool is equipped with a 1/4" (6.4 mm) male quick connector coupling. A 3/8" (9.5 mm) male quick connector coupling is available from DeWALT and may be used when a 1/4" (6.4 mm) supply line is not available. NOTE: A 3/8" (9.5 mm) supply line (and fittings) are required for maximum tool performance.

To install an air fitting 1. Wrap the male end of the fitting with thread seal tape prior to assembly to eliminate air leaks. 2. To install a 1/4" (6.4 mm) fitting: screw it directly into the air inlet and tighten firmly. NOTE: If an adapter is in the air inlet, remove it prior to inserting the fitting. 3. To install a 3/8" (9.5 mm) fitting: screw the fitting into the 3/8" (9.5 mm) adapter and then into the air inlet of the tool and tighten firmly.

OPERATION

PREPARING THE TOOL

WARNING: Read the section titled Important Safety Instructions for Pneumatic Tools at the beginning of this manual. Always wear eye and ear protection when operating this tool. Keep the nailer pointed away from yourself and others. For safe operation, complete the following procedures and checks before each use of the nailer. NOTICE: To reduce the risk of damage to the tool, only use DeWALT pneumatic tool oil or a non-detergent SAE 20 weight oil. Oil with additives or detergent will damage tool parts. 1. Before you use the nailer, be sure that the compressor tanks have been properly drained. 2. Lubricate tool:

Page 8 of the DeWalt DWFP12658 user manual — E
Page 8 · cliquer pour agrandir
Page 8

a. Use DeWALT pneumatic tool oil or a non-detergent S.A.E. 20 weight oil. DO NOT use detergent oil or additives as they will damage O-rings and rubber parts. b. Use a filter when possible. c. Add 5 to 7 drops of oil in the air fitting a least twice a day. 3. Wear eye and ear protection. 4. Ensure canister is empty of all fasteners. 5. Check for smooth and proper operation of contact trip. Do not use tool if assembly is not functioning properly. NEVER tamper with the contact trip. NEVER use a tool that has the contact trip restrained in the actuated position. 6. Adjust air supply: Ensure air pressure does not exceed recommended operating limits; 70 to 120 psi, (4.9 to 8.3 bar, 5 to 8.5 kg/cm2). 7. Keep tool pointed away from yourself and others. 8. Connect air hose. 9. Check for audible leaks around valves and gaskets. Never use a tool that leaks or has damaged parts. WARNING: To reduce the risk of personal injury, disconnect tool from air supply and engage trigger lock before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location or handing the tool to another person. LOADING THE TOOL (FIG. 1–6)

WARNING: Never load nails with the contact trip or trigger activated. Personal injury may result. 1. Read all Safety Warnings before using tool. 2. Connect the air supply to the tool. 3. Lift the canister door latch (E) to open the nail guide door (H). 4. Rotate the canister door (I) open. 5. Adjust the nail platform (J) to properly accommodate the nail length being used. Pull the nail platform (J) up or down for desired nail.

DeWalt DWFP12658 — H I diagram (page 8)
Fig. 8

E

H I

Platform PositionNail Length lowest position1-1/2" (38 mm) - 1 3/4" (44.5mm) center position1-1/4" (32 mm) upper position3/4" (19 mm) - 1" (25 mm) NOTE: 3/4" (19 mm) nails are not available for this tool.
6. Place the coil on the nail platform (J). NOTE: Observe fastener icon (K) Fig. 4. Insert fasteners (L) with points down. IMPORTANT: Fasteners must point in the same direction as they will be driven. 7. Uncoil enough nails [approximately 3" (76 mm)] to reach the nose of the tool. 8. Insert the first nail into the nose and the second nail (M) between the two rails of the feed pawl as shown in Fig. 5.
Page 9 of the DeWalt DWFP12658 user manual — S
Page 9 · cliquer pour agrandir
Page 9
DeWalt DWFP12658 — ACTUATING TOOL diagram (page 9)
Fig. 9

Fig. 3 J

DeWalt DWFP12658 — ACTUATING TOOL diagram (page 9)
Fig. 10

K

DeWalt DWFP12658 — K diagram (page 9)
Fig. 11
DeWalt DWFP12658 — K diagram (page 9)
Fig. 12

H

M

E

ACTUATING TOOL

Single Sequential actuation trigger mode - (Fig. 7) WARNING: Allow the tool to recoil off the work surface after actuation. If the contact trip remains depressed a nail will be driven each time the trigger is released and pulled, which could result in accidental actuation, possibly causing injury. The sequential actuation trigger’s intended use is for intermittent fastening where accurate fastener placement is desired.

DeWalt DWFP12658 — ACTUATING TOOL diagram (page 9)
Fig. 13

S

To operate the tool in Single sequential actuation mode: 1. Depress the contact trip firmly against the work surface. 2. Pull the trigger. 3. Allow the tool to recoil from the work surface.

Trigger mode selector button

Trigger lock button

Page 10 of the DeWalt DWFP12658 user manual — G
Page 10 · cliquer pour agrandir
Page 10

Contact actuation trigger mode - (Fig. 8) The contact actuation trigger is intended for rapid fastening on flat, stationary surfaces. Using the contact actuation trigger mode, two methods are available: place actuation and contact actuation.

DeWalt DWFP12658 — ADJUSTING DEPTH (FIG. 9) diagram (page 10)
Fig. 14

To operate the tool using the PLACE ACTUATION method: 1. Depress the contact trip against the work surface. 2. Pull the trigger to drive the fastener. 3. Allow the tool to recoil off the work surface

Trigger mode selector button

To operate the tool using the CONTACT ACTUATION method: 1. Pull the trigger. 2. Depress the contact trip against the work surface. As long as the trigger is pulled, the tool will drive a fastener every time the contact trip is depressed. This allows the user to rapidly drive multiple fastener in sequence.

  • Changing the Actuation Mode - WARNING: To reduce risk of serious injury, disconnect tool from air supply before changing actuation mode. 1. Push the (black) trigger lock button down 2. Rotate the (black) selectable trigger button counterclockwise 3. Align the triangular indicator to the desired mode
  • For Sequential Mode
  • For Contact Mode 4. Then push the trigger lock button back up to the un-locked position.

ADJUSTING DEPTH (FIG. 9)

DeWalt DWFP12658 — ADJUSTING DEPTH (FIG. 9) diagram (page 10)
Fig. 15
  • Disconnect air supply and engage trigger lock.
  • Avoid contact with trigger during adjustments. The depth that the fastener is driven can be adjusted using the depth adjustment next to the trigger of the tool. The depth of drive is factory adjusted to a nominal setting. Test fire a fastener and check depth. If a change is desired: 1. To drive the nail shallower, rotate the depth setting wheel (G) to the right. 2. To drive a nail deeper, rotate the depth setting wheel (G) to the left. The adjustment knob has detents every 1/4 turn. Test drive another fastener and check depth. Repeat as necessary to achieve desired results. The amount of air pressure required will vary depending on the size of the fastener and the material being fastened. Experiment with the air pressure setting to determine the lowest setting that will consistently perform the job at hand. Air pressure in excess of that required can cause premature wear and/or damage to the tool.

G

Trigger lock button

Page 11 of the DeWalt DWFP12658 user manual — CLEARING A JAMMED NAIL (FIG. 1, 13)
Page 11 · cliquer pour agrandir
Page 11
DeWalt DWFP12658 — CLEARING A JAMMED NAIL (FIG. 1, 13) diagram (page 11)
Fig. 16
DeWalt DWFP12658 — CLEARING A JAMMED NAIL (FIG. 1, 13) diagram (page 11)
Fig. 17

P

O

O

Q

R

SHINGLE GUIDE (FIG. 11, 12) Adjust shingle guide (O): 1. Loosen the adjusting lever (P) and slide the locking plate to desired position. 2. Tighten adjusting lever firmly.

The locking plate (O) can be used as an aid to position the shingle being nailed a specific distance (Q) from the front edge of the previous row of shingles (R) as shown.

CLEARING A JAMMED NAIL (FIG. 1, 13)

WARNING: Disconnect air line from tool, engage trigger lock and remove fasteners from magazine before making adjustments or personal injury may result. If a nail becomes jammed in the nosepiece, keep the tool pointed away from you and follow these instructions to clear: 1. Disconnect the air supply from the tool. 2. Lift the canister door latch (E) to open the nail guide door (H). 3. Open the canister door. 4. Remove the jammed nail. 5. Correct any deformation that may have occurred to the nail coil. NOTE: Should nails continue to jam frequently in nosepiece, have tool serviced by an authorized DeWALT service center.

DeWalt DWFP12658 — CLEARING A JAMMED NAIL (FIG. 1, 13) diagram (page 11)
Fig. 18

COLD WEATHER OPERATION When operating tools at temperatures below freezing: 1. Make sure compressor tanks have been properly drained prior to use. 2. Keep tool as warm as possible prior to use. 3. Make certain all fasteners have been removed from canister. 4. Put 5 to 7 drops of DeWALT pneumatic tool oil in the air inlet. 5. Lower air pressure to 80 psi (5.5 bar) or less. 6. Reconnect air and load nails into canister. 7. Actuate the tool 5 or 6 times into scrap lumber to lubricate O-rings. 8. Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal. 9. Re-lubricate at least once daily. 10. Always drain the compressor tanks at least once a day.

Page 12 of the DeWalt DWFP12658 user manual — ACCESSORIES
Page 12 · cliquer pour agrandir
Page 12

HOT WEATHER OPERATION Tool should operate normally. However, keep tool out of direct sunlight as excessive heat can deteriorate bumpers, O-rings and other rubber parts resulting in increased maintenance.

MAINTENANCE

DAILY MAINTENANCE CHART

ACTIONWHYHOW Lubricate tool with 5-7 drops of DeWALT Pneumatic Tool OilPrevents failure of o-ringsInsert drops into air fitting on end cap of tool Drain compressor tanks and hoses dailyPrevents accumulation of moisture in compressor and nailerOpen petcocks or other drain valves on compressor tanks. Allow any accumulated water to drain from hoses Clean canister, feed piston area and contact trip mechanism.Permits smooth operation of magazine, reduces wear and prevents jams.Blow clean with compressor air. The use of oils, lubricants periodically or solvents is not recommended as they tend to attract debris. Before each use, check to insure all screws, nuts and fasteners are tight and undamaged.Prevents jams, leaks and premature failure of tool parts.Tighten loose screws or other fasteners using the appropriate hex wrench or screwdriver.

CLEANING

REPAIRS To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DeWALT factory service center, a DeWALT authorized service center or other qualified service personnel. Always use identical replacement parts. Refer to the Troubleshooting Guide at the end of this section.

ACCESSORIES

Page 13 of the DeWalt DWFP12658 user manual — THREE YEAR LIMITED WARRANTY
Page 13 · cliquer pour agrandir
Page 13

Recommended accessories for use with your tool are available at extra cost from your local dealer or authorized service center. If you need assistance in locating any accessory, please contact DeWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286, call 1-800-4-DeWALT (1-800-433-9258) or visit our website www.dewalt.com

THREE YEAR LIMITED WARRANTY

DeWALT will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www.dewalt.com or call 1-800-4-DeWALT (1-800-433-9258). This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces. In addition to the warranty, DeWALT tools are covered by our: 1 YEAR FREE SERVICE: DeWALT will maintain the tool and replace worn parts caused by normal use, for free, any time during the first year after purchase. Nailer wear items, such as o-rings and driver blades, are not covered. 90 DAY MONEY BACK GUARANTEE: If you are not completely satisfied with the performance of your DeWALT Power Tool, Laser, or Nailer for any reason, you can return it within 90 days from the date of purchase with a receipt for a full refund – no questions asked. LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained in the packaging, call the local company or see website for warranty information.

DeWalt DWFP12658 — THREE YEAR LIMITED WARRANTY diagram (page 13)
Fig. 19
Page 14 of the DeWalt DWFP12658 user manual — TOOL SPECIFICATIONS
Page 14 · cliquer pour agrandir
Page 14

TROUBLESHOOTING GUIDE MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE CHART BELOW. FOR MORE SERIOUS OR PERSISTENT PROBLEMS, CONTACT A DeWALT SERVICE CENTER OR CALL 1-(800)-4-DeWALT (1-800-433-9258).

SYMPTOM PROBLEMS SOLUTIONS Air leak near top of tool or in trigger area

Loose screws. Tighten screws. Worn or damaged o-rings or seals.

Install Overhaul Kit.

Tool does nothing or operates sluggishly

Inadequate air supply. Verify adequate air supply. Inadequate lubrication. Put 5 or 7 drops of oil into air inlet. Worn or damaged o-rings or seals.

Install Overhaul Kit.

Air leak near bottom of tool

Loose screws. Tighten screws. Worn or damaged o-rings or bumper.

Install Overhaul Kit.

Tool jams frequently Incorrect fasteners. Verify approved fasteners of correct size and 15° collation angle. Damaged fasteners. Bent collation wire.

Replace with undamaged fasteners. Canister or nose screws loose Tighten screws. Canister is dirty. Clean magazine. Driver tip is worn or damaged. Install Driver Maintenance Kit. Other Contact a DeWALT Authorized Warranty Service Center

TOOL SPECIFICATIONS

DWFP12658

Height (inch/mm) 10.5/ 266

Width (inch/mm) 4.3/ 110

Length (inch/mm) 10.3/ 262

Weight (lbs/kg) 4.91/ 2.23

Recommended Operating Pressure 70-120 psi (4.8 to 8.3 bar) Air Consumption per 100 cycles 4.13 CFM Loading capacity 120 nails

Page 15 of the DeWalt DWFP12658 user manual — TOOL SPECIFICATIONS
Page 15 · cliquer pour agrandir
Page 15
DeWalt DWFP12658 — TOOL SPECIFICATIONS diagram (page 15)
Fig. 20

Compressor will be sufficient for tools at all production rates.

Compressor will be sufficient at slow or moderate production rates, but may have difficulty at very rapid rates.

Compressor will be adequate only when tools are utilized at slow production rates (punch-out or occasional use).

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : DeWalt DWFP12658

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le DeWalt DWFP12658

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

DeWalt DWFP12658 manuel PDF

48 pages·7.3 MB·Cloueuse·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…