Model 5000/6000 Model 5000/6000 FLOW-THROUGH FURNACE HU M IDIFIER Warranty Maintenance Troubleshooting Guide.
W ARRANTY The manufacturer guarantees the for the period of one year from the date of purchase, the product will be free of defects in workmanship and/or material. As well the manufacturer offers a life time warranty on the flow through humidifier body .
4. The inlet filter is located inside the black orifice fitting . Using a pointy object (i.e. nail), remove the inlet. 5. The filter should be fairly clean and free of depree, 6. Replace or clean the inlet filter if required. If punctured or damaged, replace before operating the humidifier .
14. Reinstall the solenoid valve onto the humidifier side, feed the flexible black water supply tube back through the humidifier side, reinstall the humidifier side (if removed) onto the humidifier bo.
5 Model 5000/6000 Flow Through Humidifiers Component Item Description P arts List/ Humidifier Model Component Number W arranty P eriod Recommended Maintenance Duct Mount Humidity Sensor 6000 29 1 year Replace as required. Humidisense Electronic Humidifier Control 5000/6000 Not Shown 1 year Replace as required.
6 WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE 010912000 1 /per d r ain ins er t 3 2 3 * S pe c i fy b r and 2 8 2 6 2 7 2 5 2 4 1 3 1 8 22 21 20 19 1 6 1 7 1 5 1 4 8 11 12 10 9 6 7 5 4 0109 3 7 000 1 .
7 Model 5000/6000 Flow Through Humidifiers 3 drain insert 1/p er 0 1 09 1 2000 1 5 f eet / u nit 3 f eet / u nit 1 0 f eet / u nit in l et w ater f i l ter 2 3 * S p e c i f y b rand 2 8 2 7 2 6 2 5 2.
TROUBLE SHOO TING GUIDE MODEL 5000 AND 6000 HUMIDIFIERS PROBLEM : NOT ENOUGH HUMIDITY POSSIBLE CAUSE : Humidistat set too low . REMEDY : T urn up the humidistat.
REMEDY : • Adjust bypass damper to fully open position. • Ensure the bypass tube is fully stretched out tight. • F urnace filter is dirty and needs replacement. • Bypass tube and humidifier not installed parallel, use hard ducting – use hard ducting for any elbows – take the most direct route when ducting .
• The bypass tube or humidifier is installed in front of air- conditioning coils or is blocked in some other way – move to another location and ensure maximum air flow . • The fan delay on your furnace is not set properly and the furnace fan is shutting off too early when the air is still hot.
POSSIBLE CAUSE : The humidifier is not turning off when the furnace is turning off . REMEDY : See section above for solution. If the unit is running when the furnace is not in heating mode then very little water will be evaporated and most of the water will be going down the drain.
MODEL 6000 HUMIDIFIERS ONL Y PROBLEM : THE DIGIT AL HUMIDIST A T KEEPS RESET TING TO THE DEFAUL T SET TINGS. POSSIBLE CAUSE : P ower source (transformer) is plugged into an outlet which is being shut off or turns off via a switch.
MODEL AK5000 AK5500 & AK7000 SUPPLEMENTAL INSTRUCTION SHEET WARNING: THIS UNIT IS INTENDED TO BE INSTALLED BY AN LICENCED HVAC PROFESSIONAL – FOR THIS UNIT TO OPERATE PROPERLY THE SUPPLIED 24 VO.
FEUILLE D’INSTRUCTION COMPLÉMENTAIRE, MODÈLES AK5000, AK5500 ET AK7000 MISE EN GARDE : CET APPAREIL EST CONÇU PO UR ÊTRE INSTALLÉ PAR UN PROFESSIONNEL CVC AUTORISÉ SOUS LICENCE – POUR QUE CE.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Air King AK5000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Air King AK5000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Air King AK5000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Air King AK5000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Air King AK5000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Air King AK5000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Air King AK5000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Air King AK5000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.