Serial Number Prefixes: Error Messages Agilent T echnologies ESG F amily Signal Generators P art No. E4400-90333 Printed in USA June 2001 Supersedes F ebruary 2001 © Copyright 1999-2001 Agilent T ec.
Contents iii Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Error Message Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 ESG Famil y Signal Generators Introduction If an error condition occurs in the signal generator , it is reported to both the front panel display error queue and the SCPI (remote interface) error queue . These two queues are viewed and managed separately .
2 Error Messages Error Message Format ESG Famil y Signal Generators Error Message F ormat The system-defined error numbers are chosen on an enumerated (“1 of N”) basis . The SCPI-defined error numbers and the <error_description> portions of the error query response are displayed on the instrument.
Error Messa ges 3 ESG Famil y Signal Generators Error Message T ypes Error Message Types Events do not generate more than one type of error . F or example, an event that generates a query error will not generate a device-specific, execution, or command error .
4 Error Messages 0: No Error ESG Famil y Signal Generators 0: No Error 0 No error, No Error Message(s) in Queue The queue is empty . Every error in the queue has been read, or the queue was purposely c leared using either the Clear Error Queue(s) softkey or *CLS .
Error Messa ges 5 ESG Famil y Signal Generators -499 to -400: Query Errors -499 to -400: Query Errors The instrument’ s output queue control has detected a problem with the message exchange protocol described in IEEE 4888.2, Chapter 6. Errors in this class set the query error bit (bit 2) in the event status register (IEEE 488.
6 Error Messages -399 to -300: Device-Specific Errors ESG Famil y Signal Generators -399 to -300: Device-Specific Errors Some device operations did not properly complete, possibly due to an abnormal hardw are or firmware condition. These codes are also used for self-test response errors .
Error Messa ges 7 ESG Famil y Signal Generators -399 to -300: Device-Specific Error s Self-test failed; Burst Generator Memory Test @ 0x____ The burst generator memory failed.
8 Error Messages -399 to -300: Device-Specific Errors ESG Famil y Signal Generators Out of memory There was insufficient working memory during data generation pattern calculations .
Error Messa ges 9 ESG Famil y Signal Generators -399 to -300: Device-Specific Error s Out of memory; Complementary Cumulative Distribution. Display cannot function. There is insufficient working memory available . Report this error to the nearest Agilent T ec hnologies sales or service office.
10 Error Messages -399 to -300: Device-Specific Errors ESG Famil y Signal Generators Out of memory; Histogram display cannot function. There is insufficient working memory available . Report this error to the nearest Agilent T ec hnologies sales or service office.
Error Messa ges 11 ESG Famil y Signal Generators -399 to -300: Device-Specific Error s Out of memory; Memory allocation error. There is insufficient working memory available . Report this error to the nearest Agilent T ec hnologies sales or service office.
12 Error Messages -399 to -300: Device-Specific Errors ESG Famil y Signal Generators Out of memory; There is not enough memory to create the modulation. Baseband cannot function. There is not enough memory to create the modulation map. Reduce the size of any list/sweep, and preset the source to c lear up any inconsistencies .
Error Messa ges 13 ESG Famil y Signal Generators -399 to -300: Device-Specific Error s Out of memory; Unable to check Data Generator memory. There was not enough memory in the system to properly complete the data generator memory test. This does not imply a data generator memory failure.
14 Error Messages -399 to -300: Device-Specific Errors ESG Famil y Signal Generators Configuration memory lost; Persistent state checksum is bad. Using factory defaults. The persistent state is corrupt and had to be reinitialized with the factory preset values .
Error Messa ges 15 ESG Famil y Signal Generators -399 to -300: Device-Specific Error s System error; Cannot change manual point until list mode error condition cleared. An error is keeping the sweep/list from being able to set the frequency and/or power .
16 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators -299 to -200: Execution Errors An error has been detected by the instrument’ s execution control block. Errors in this class set the execution error bit (bit 4) in the event status register (IEEE 488.
Error Messa ges 17 ESG Famil y Signal Generators -299 to -200: Execution Error s Program runtime error; Floating-Point Exception A floating-point math error (such as a divide by zero) has been detected. The system will attempt to recover automatically .
18 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators -276 Macro recursion error A syntactically legal macro program data sequence could not be executed because the device found it to be recursive (see IEEE 488.
Error Messa ges 19 ESG Famil y Signal Generators -299 to -200: Execution Error s -260 Expression error An expression data element-related error occurred. This error message is used when the device cannot detect the more specific errors described for errors -261 through -269.
20 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators File name error; Illegal filename character An illegal character w as used within a filename. , : , @ and all non-printable ASCII characters are illegal in filenames . File name error; Only one “:” is allowed.
Error Messa ges 21 ESG Famil y Signal Generators -299 to -200: Execution Error s File name not found; The internal list file was not found. There is no list data to return The DWEL_FILE , FREQ_FILE , or POW_FILE has been lost, so a new one will have to be created.
22 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators -254 Media full A legal program command or query could not be executed because the media was full. F or example, there is w as no space left on the disk. The definition of what constitutes full media is device-specific.
Error Messa ges 23 ESG Famil y Signal Generators -299 to -200: Execution Error s -252 Missing media A legal program command or query could not be executed because of missing media, for instance no disk in the disk drive. The definition of what constitutes missing media is device-specific.
24 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Hardware missing; no such SIO address The expected board is not installed.
Error Messa ges 25 ESG Famil y Signal Generators -299 to -200: Execution Error s Data corrupt or stale; <filename>. The sequence file that you are attempting to run is the wrong size. Data corrupt or stale; <NAME> differs offset 0x<VALUE>: NVRAM 0x<VALUE>, EEPROM 0x<VALUE>.
26 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Data corrupt or stale; License file is obsolete, missing entries defaulted . This error can only occur during the instrument’ s first power up after having downloaded new firmw are.
Error Messa ges 27 ESG Famil y Signal Generators -299 to -200: Execution Error s -223 Too much data A legal program data element of block, expression or string type w as received that contained more data than the device could handle due to memory or related device-specific requirements .
28 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Due to a hardware limitations , only a certain number of unique data points can be created for the IQ map. This c hannel power level has resulted in an IQ map that exceeds the hardware limit when turned on, and cannot be accommodated.
Error Messa ges 29 ESG Famil y Signal Generators -299 to -200: Execution Error s Too much data; Only 16 distinct values are allowed for I and Q values. Option UN8 cannot use an I/Q map that has more than 16 unique values defined for I and Q (distinct values are listed in the I/Q table editor).
30 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Data out of range; Manual point exceeds list sizes. Limiting to maximum point. The sweep/list manual point has been reassigned to a smaller number value due to the longest list decreasing in size or being turned off .
Error Messa ges 31 ESG Famil y Signal Generators -299 to -200: Execution Error s Data out of range; value clipped to upper limit. An input value is above the maximum value allowed.
32 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; Cannot have a secondary frame with alternate amplitude.
Error Messa ges 33 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; Cannot have more than 4 EDGE multiframe timeslots on simultaneously. The selected timeslot has been turned off. An unsupported timeslot type was encountered.
34 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; The current data rate is not valid for this radio configuration. Data rate changed to the default rate. The new radio configuration does not support the current data rate.
Error Messa ges 35 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; Continuous & Discontinuous setting conflict. All selected Continuous timeslots are now switched to Discontinuous.
36 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; EDGE BERT requires Normal as Timeslot Type. An unsupported timeslot type was encountered. The measurement timeslot must be designated Normal. Settings conflict; Enabled mod source conflicts with previously enabled mod source.
Error Messa ges 37 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; FM2/PM2 value set greater than FM1/PM1 value. FM1/PM1 changed to match FM2/PM2 value.
38 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; Frequency list and power list are of unequal size. Turn one list off, set one to size one, or make their sizes equal. The frequency list has more than one element and the power list has more than one element, and they are not of equal size.
Error Messa ges 39 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; Incompatible step sweep frequency setting. Start, stop, center or span setting changed to be compatible with last command. Incompatible step sweep frequency setting .
40 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; I/Q & AM WB cannot be on at the same time. The modulation types I/Q and AM WB cannot be used at the same time. This error is reported when the user attempts to activate one type of modulation while the other is activated.
Error Messa ges 41 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; Pulse modulation cannot be on with internal burst. There is a hardware conflict between pulse modulation and internal burst. The most recently requested modulation is turned on, the previous modulation is turned off .
42 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; RDCCH is only defined for Radio Configuration 3 and 4.
Error Messa ges 43 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; RSCH is only defined for Radio Configuration 1 and 2. You must set one of these Radio Configurations before configuring or using this code channel. The command attempted to enter a value or setting for the R-SCH in RC1 or 2.
44 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Settings conflict; The selected external trigger setting conflicts with the previous setting. The external trigger has been set to positive edge for one trigger source and negative edge for another trigger source.
Error Messa ges 45 ESG Famil y Signal Generators -299 to -200: Execution Error s Settings conflict; Walsh length invalid! Changed to default Walsh number. The current W alsh length is invalid for the current data rate. F or data rate 2X and above, doubling the rate halves the W alsh space .
46 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators -220 Parameter error A program data element related error has occurred. This particular error message is used if the device cannot detect a more specific error described for errors -221 through -229.
Error Messa ges 47 ESG Famil y Signal Generators -299 to -200: Execution Error s Init ignored; Unable to sweep due to sweep being in an error state. The sweep error should be fixed. The number of list, power , and/or dwell points are in conflict, or a serious system error has occurred in list/sweep.
48 Error Messages -299 to -200: Execution Errors ESG Famil y Signal Generators Execution Error; Cannot update FlexDG with Even Second Delay. There is an error with the cdma2000 hardware .
Error Messa ges 49 ESG Famil y Signal Generators -199 to -100: Command Errors -199 to -100: Command Errors The instrument’ s parser detected an IEEE 488.2 syntax error . Errors in this class set the command error bit (bit 5) in the event status register (IEEE 488.
50 Error Messages -199 to -100: Command Errors ESG Famil y Signal Generators -170 Expression data error This error , as well as errors -171 through -179, are generated when parsing an expression data element. This particular error message is used if the device cannot detect a more specific error .
Error Messa ges 51 ESG Famil y Signal Generators -199 to -100: Command Errors -150 String data error This error , as well as errors -151 through -159, are generated when parsing a string data element. This particular error message is used if the device cannot detect a more specific error .
52 Error Messages -199 to -100: Command Errors ESG Famil y Signal Generators -128 Numeric data not allowed A legal numeric data element was received, but the device does not accept one in this position for the header .
Error Messa ges 53 ESG Famil y Signal Generators -199 to -100: Command Errors -110 Command header error An error was detected in the header . This message is used when the device cannot detect the more specific errors described for errors -111 through -119.
54 Error Messages -199 to -100: Command Errors ESG Famil y Signal Generators Syntax error An unrecognized command or data type was encountered. F or example, a string was received when the device does not accept strings . -101 Invalid character A syntactic command contains a character that is invalid for that type .
Error Messa ges 55 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors 201 to 702: Device-Specific Errors Some device operations did not properly complete, possibly due to an abnormal hardw are or firmware condition. These codes are also used for self-test response errors .
56 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators A STATe: file could not be saved due to insufficient space , file corruption, or another related problem. I/O error; Trailing zero found in <filename>. Fixing.
Error Messa ges 57 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors The firmware has c hanged the attenuator setting because, while in attenuator hold mode, a c hange in frequency setting has forced the ALC beyond its range. Attenuator hold setting over range; Power set to lower limit.
58 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators 513 1 GHz Oscillator unlocked The 1 GHz reference oscillator is unlocked. If an external reference is connected, check the frequency . If this error reoccurs when no external reference is connected, the instrument may require service .
Error Messa ges 59 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors Calibration failure; DCFM DC overrange The instrument was unable to perform a DCFM or DC Φ M calibration due to the input signal being outside of the offset range that can be calibrated for .
60 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators Uncalibrated signal; Quadrature Skew Not Calibrated A calibration is required to use the quadrature skew feature. The quadrature skew may be functional, but is not guaranteed to meet specifications until the I/Q impairment adjustment is performed.
Error Messa ges 61 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors 605 DSP FW download failed. The instrument’ s firmware w as unable to successfully initialize the internal digital signal processor (DSP) on the A14 CPU/Motherboard.
62 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators DSP times out; Demodulator communication failed The digital signal processor (DSP) on the Demodulator board (Option 300) failed to respond within the appropriate amount of time.
Error Messa ges 63 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors DSP returns error; ARB data line error (code) The dual arbitrary wa veform generator (Option UND) digital signal processor (DSP) detected an internal error when processing a command.
64 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators 616 Configuration Error; Attenuator configuration does not match actual installed attenuator type. A mismatch w as found between the configured and detected attenuator types .
Error Messa ges 65 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors Configuration error; Installed board not supported. An option board or board combination that is not supported by the installed firmware has been specified or detected.
66 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators Configuration error; Old bootrom detected. File system and instrument state re-initialized due to firmware upgrade. Replace bootrom to avoid this in the future. The firmware has detected that the instrument contains an old bootrom version.
Error Messa ges 67 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors DSP code is invalid; Flex DG DSP code is invalid. The version number of the DSP firmware in the FlexDG data generator is not the version expected by the instrument firmware .
68 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators 621 FPGA download failed; Demodulator board. The download of the field programmable gate array code to the Demodulator board failed.
Error Messa ges 69 ESG Famil y Signal Generators 201 to 702: Device-Specific Errors State Save Recall Error; Recall data different from FW revision. No instrument state change. An attempt was made to recall a state that w as saved with an incompatible version of the instrument firmware .
70 Error Messages 201 to 702: Device-Specific Errors ESG F amily Signal Generators Load/Store Error; Cannot create a shape with less than 2 points. Burst shape files must have two or more points for both the rise and the fall shape specification. Load/Store Error; Invalid modulation file.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Agilent Technologies E4400-90333 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Agilent Technologies E4400-90333 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Agilent Technologies E4400-90333, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Agilent Technologies E4400-90333 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Agilent Technologies E4400-90333, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Agilent Technologies E4400-90333.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Agilent Technologies E4400-90333. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Agilent Technologies E4400-90333 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.