Manuel d'utilisation / d'entretien du produit 84700 du fabricant Cooper Lighting
Aller à la page of 41
Cooper Industries Crouse - Hinds Division Crouse - Hinds Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 860 683 - 4300 Fax 860 683 - 4354 Title: COPYRIGHT © 2006 Cooper Technologies Co.
9131 Rev. M REV. DESCRIPTION LTR. CHK. APV A Added Figure 6 - 3, - 4, - 11 (Pg. 39); Pg. 37 deleted S2 switch; Pg. 24 & 25, 6.3, 6.4 & 6.11, added figure for remote connections & deleted info that was present for remote connections; Pg. 25, 6.
9131 Rev. M LIMITED PRODUCT WARRANTY THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT BY WAY OF LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR F ITNESS FOR ANY PARTICULAR PURPOSE.
9131 Rev. M SAFETY NOTICES This equipment is normally used or connected to circuits that may employ voltages, which are dangerous and may be fatal if accidentally contacted by operating or maintenance personnel. Extreme caution should be exercised when working with this equipment.
9131 Rev. M TABLE OF CONTENTS PAGE Title Page................................. ..............................................................................................................i Revisions...................................................
9131 Rev. M FIGURES PAGE Figure 2- 1 Typical CSC Timing Diagram....................................................................................5 Figure 3A 84700 - 1 or - 2 Suggested Conduit Entrances........................................ .......
9131 Rev. M SECTION 1 GENERAL INFORMATION 1.1 INTRODUCTION 1.1.1 Purpose This instruction book provides field support data and information for the FAA Type L - 847 Runway Circuit Selector Switches manufactured by Crouse - Hinds Airport Lighting Products, Windsor, CT 06095.
9131 Rev. M 1.2.4.1 FAA Classification Type: L - 847 - 1, - 2, - 3, - 4 Class: A (for Class B, order Option - 10 or - 13) Rating: 1 and 2 (Dual Rating) 1.2.4.2 Electrical Characteristics Primary Power: L - 847 - 1, - 2: 120 VAC, 1.2A, 50/60Hz L - 847 - 3, - 4: 1 20 VAC, 2.
9131 Rev. M TABLE 1 - 1 84700 PART NUMBERS UP TO THREE OPTIONS BASIC NO ..... - ..... NUMBER OF CIRCUITS ..... - ..... OPT A ..... - ..... OPT B ..... - .
9131 Rev. M SECTION 2 TECHNICAL DESCRIPTION 2.1 THEORY OF OPERATION The operational discussion presented herein pertains to standard model CSC units. Equipment supplied with options may deviate somewhat from the exact operational description pr esented, but the basic operating principles are identical for all equipment configurations.
9131 Rev. M 5.
9131 Rev. M SECTION 3 INSTALLATION AND OPERATION WARNING INSTALLATION, SERVICE, MAINTENANCE OR OPERATION SHOULD BE PERFORMED BY QUALIFIED PERSONN EL ONLY. 3.1 INSTALLATION All CSC units are supplied ready for operation with all ordered options installed.
9131 Rev. M 3.1.3.1 Mechanical Installation Cont'd ( ) 3. Remove the electrical assembly from the enclosure by loosening and removing the mounting hardware from the four corners of the base plate panel. ( ) 4. The electrical assembly can now be placed in the shipping carton for protection.
9131 Rev. M 3.1.3.2 Electrical Wiring Cont'd ( ) 5. Connect each lighting load to the respective LOO P terminals in the high voltage section, using the #12 AWG ring terminals provided. NOTE: BEFORE CONNECTING LOAD TO LOOP TERMINALS, REMOVE JUMPER FROM ONLY THOSE TERMINALS THAT LOAD IS BEING CONNECTED TO.
9131 Rev. M 9.
9131 Rev. M 10.
9131 Rev. M 11.
9131 Rev. M 3.2 OPERATION 3.2.1 Initial Checkout This checkout is divided into two sections. In the first section, all control functions are checked. In the second, the high voltage functions are checked. If the CSC fails to perform properly at any step of this procedure, consult the troubleshooting guide in Section 4.
9131 Rev. M 3.2.1.2 High Voltage Functions Cont'd D. Attempt to turn on the CCR. Verify it does not turn on. E. After repeating Step A above, re - install the dead front cover on the CSC. F. Restore power to all circuits. 3.2.2 Normal Operation In most cases, the CSC will be operated from a remote location.
9131 Rev. M SECTION 4 MAINTENANCE WARNING INSTALLATION, SERVICE, MAINTENANCE OR OPERATION SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY. 4.1 PERIODIC MAINTENANCE The CSC should be inspected periodically as shown be low: INTERVAL ACTION 1 month (A) Visually inspect high voltage relays through clear dead front cover.
9131 Rev. M 4.2 CORRECTIVE MAINTENANCE CONT'D WARNING VOLTAGES IN EXCESS OF 1000 VOLTS ARE PRESENT WHEN THE REGULATOR IS OPERATING. DO NOT ATTEMPT REPAIR OR SERVICING WITHOUT FIRST REMOVING POWER FROM THE REGULATOR.
9131 Rev. M 16.
9131 Rev. M 17.
9131 Rev. M TABLE 4 - 2 TROUBLESHOOTING PROCEDURE PROBLEM POSSIBLE CAUSE TEST CORRECTIVE ACTION CSC does not operate in remote (all circuits) Power source not energized Verify voltage is present at TB.
9131 Rev. M PROBLEM POSSIBLE CAUSE TEST CORRECTIVE ACTION No distinct delay between high voltage relay actions Defective timing circuit card ------ Replace the timing circuit card.
9131 Rev. M SECTION 5 PARTS LIST 5.1 SCOPE The following Parts List provides ordering data for all repairable or replaceable components and assemblies. 5.1.1 List of Figures Figure 5- 1 Component I dentification, 84700 - 1 or - 2 Figure 5- 2 Component Identification, 84700 - 3 or - 4 5.
9131 Rev. M 21.
9131 Rev. M 21a.
9131 Rev. M 22.
9131 Rev. M TABLE 5 - 1 PARTS LIST, 84700 - 1 OR - 2 ITEM NO REFERENCE DESIGNATION QUANTITY - 1 - 2 DESCRIPTION CROUSE HINDS PART NUMBER 1 1 1 Cabinet 31525 2 1 1 Base Plate 30858 3 1 1 Low Voltage Pa.
9131 Rev. M TABLE 5 - 2 PARTS LIST, 84700 - 3 OR - 4 ITEM NO REFERENCE DESIGNATION QUANTITY - 3 - 4 DESCRIPTION CROUSE HINDS PART NUMBER 1 1 1 Cabinet 31530 2 1 1 Base Plate 30859 3 1 1 Low Voltage Pa.
9131 Rev. M SECTION 6 OPTIONS 6.1 SCOPE The follo wing listing provides parts ordering data and customer installation data. 6.2 OPTION - 2 The part number for the 220VAC transformer is 10047 - 1444. Customer primary input connections are at points H1 and H4 on the transformer; see Figures 6 - 2A and 6 - 2B.
9131 Rev. M 6.9 Option - 9 Item 11 P/N is 10047 - 1878. Item 12 P/N is 46 - 192 - 5X/D - 8. The part number for the interlock switch harness is 31985 - 1.
9131 Rev. M TABLE 6 - 1 PART NUMBE R USED ON 31955 - 1 84700 - 1 or - 2 31955 - 2 84700 - 3 or - 4 31955 - 3 84700 - 2 - 9 31955 - 4 84700 - 1 or - 2 w/Opt. - 8 31955 - 5 84700 - 3 or - 4 w/Opt. - 8 31955 - 6 84700 - 1 or - 2 w/Opt. - 3 31955 - 7 84700 - 3 or - 4 w/Opt.
9131 Rev. M 28.
9131 Rev. M 29.
9131 Rev. M 30.
9131 Rev. M 31.
9131 Rev. M 32.
9131 Rev. M 33.
9131 Rev. M 34.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Cooper Lighting 84700 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Cooper Lighting 84700 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Cooper Lighting 84700, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Cooper Lighting 84700 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Cooper Lighting 84700, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Cooper Lighting 84700.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Cooper Lighting 84700. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Cooper Lighting 84700 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.