Manuel d'utilisation / d'entretien du produit PS-8300 du fabricant Cobalt Networks
Aller à la page of 40
Cob alt Digital Inc. 8310(-C) openGear TM Tw o Rack Unit Frame and Pow er Supply (PS-8300) User Manual 8310-UM Version: 1.0.1.
Page 2 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) 8310 • • • • openGear TM Tw o Rack Unit Frame and Powe r Supply (PS-8300) User Manual • Cobalt Digital Inc. Part Number: 8310-UM • Documen t Versio n: 1.0.1 • Printed in the United States.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 3 of 40 Important Regulatory and Safety Notices Before usin g this produ ct and any ass ociated equipm ent, refer to the “Im portant Safety Instru ctions” listed bel o w so as to av oid personal injury and to prevent produ ct damage.
Page 4 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Important Safety Instructions Read these in structions . Keep these ins tructions. Heed all w arnings . Follow all instructions . Warn ing The safe operation of this product requires that a protectiv e earth connection be provided.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 5 of 40 Product Pow e r Cord Requirements Warn ing North American Line Voltages 100 - 120 Volts This product is supplied w ith certi fied 10A/125V S VT ty pe supply cords. Conductors are color coded w hite (neutral), black (line) and green or green /yellow (groun d).
Page 6 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Maintenance/User Serv iceable Parts Routine m aintenance to this Cobalt Digital Inc. product is not required.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 7 of 40 Contents Introduction 9 In This Ch apter................................................................................................................ ...........9 A Word of Thanks .........
Page 8 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Install ing the Rear Su pport Bars and Brackets .......................................................... 35 Service Information 36 In This Ch apter ..........................................
8310 Us er Ma nu al • • • • (V 1.0.1) Page 9 of 40 Introduction In This Ch apter This chapter contain s the follow ing sections : • A Wor d of Tha nks • Overview • Features • Documenta tion T erms A Word of Thanks Congra tulations o n choosing the 8310 op enGear TM Two Rack Unit Frame and Power Supply (PS- 8300).
Page 10 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Robust Pow er Supplies The 8310 fram e can accomm odate two front- loaded P S-8300 power s upplies. A ltho ugh a si ngle power supply can f ully power a loaded fram e, the add itio n of a second (optional) power supply g ives the fram e full power redu ndancy.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 11 of 40 • Robus t 150 Watt Powe r Supply wi th integ ral cooling f an • Optiona l redun dant pow er supply is hot-s w appable for 24/7 operation.
Page 12 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Installation and Setup In This Ch apter This chapter contain s the follow ing sections : • Static Discharge • Unpacking • Installing t.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 13 of 40 Installing the Frame The 8310 fram e mounts i n the rack frame by means of four rack screw s fastened t hro ugh the fro nt moun ting flan ges. T his sh o u ld normally be sufficient to carry th e lo ad, inclu ding the w eight of accompany ing cables.
Page 14 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Note In case of a pow er supply failure, contact y o ur openGear TM dealer. The PS-8300 is a power factor corrected s upply, capable of workin g wit h all worl d AC s tandards (100-240V).
8310 Us er Ma nu al • • • • (V 1.0.1) Page 15 of 40 Notice For reliable perf ormance, it is recommen ded that the fram e door not b e opene d for lo nger than 5 m i nut e s w he n using the Coo l i ng Fan Module option on frames loaded w ith more than 40 Watt.
Page 16 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) 4. Each AC connector includes a Pow erlock, which is design ed to retain the power cable connector.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 17 of 40 Rear I/O Module Installation If y o u are installing an openGear TM card in a 8310- C-BNC or 8310- BNC frame, s kip this s ection.
Page 18 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) openBUS Connector This RJ45 conn ector is used to exch ange inf ormati on data f rom cards inst alled in t he 8310 frame to an external m onitoring/control system . Only cards havin g the openBUS interface will be able to be monitored and controlled this w ay.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 19 of 40 SMPTE 269M Fault Reporting Option In This Ch apter This chapter contain s the follow ing sections : • Overview • Frame C o n nections .
Page 20 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Frame Connections The SMPTE 269M Fault R eporting conn ection on openGear TM 8310 s eries fram es is prov ided by the FAULT BNC connector, f or interfacing w ith a custom er-designed alarm system .
8310 Us er Ma nu al • • • • (V 1.0.1) Page 21 of 40 Specifications In This Ch apter This chapter contain s the Technical Specif ications table. Technical Specifications Table 2. Technic al Specific at ions Category Parameter Specificat ion Input 100 - 240VA C, 47-63 Hz, 190 Watt Outpu t 1 +12V, ± 10%, 0.
Page 22 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Category Parameter Specificat ion Level 1Vp p nominal Signal Analog video syn c (black burst or t ri-lev el), or AES/EBU DARS Impedan ce 75 .
8310 Us er Ma nu al • • • • (V 1.0.1) Page 23 of 40 Important Notes: The power dis sipation of each product ins talled in this fram e is indicated in the Specification s section of the docum entation provided with each m odule.
Page 24 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Frame Features In This Ch apter This chapter contain s the follow ing sections : • Cooli ng Features o Installing the Cooling Fan Mo d ule.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 25 of 40 Cooling Feature s The standard 8310 f rame can be also be ordered as the 8310- C vers ion, w ith the C ooling Fan Modu le installed as orig inal equipmen t from the factory.
Page 26 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) 1. Open the C FM-8310 packag e and remove the com ponents. Verify that all necessary compon ents are included. • Fan PCB 8310A-016 • Fan Filter S985-006 • 8 nu ts 650- 007 • 8 w ashers 960-025 • MFC- 8310(-N) Frame C ontroller C ard 2.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 27 of 40 Next y ou will inst all either an MFC-8310 or an MFC- 8310-N controller card. Refer to th e appropriate section for installation instru ctions for y o ur sp ecific controller card.
Page 28 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) seconds af ter the fan door is closed, t hen adjust to th e appropriate lev el based on pow er consumpti on. • Monitors the f rame door an d PS-8300(s) to ensu re that fans in all u nits are operatin g correctly.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 29 of 40 LED displays an d descriptions are pro vided in the following table: Table 3. MFC-8310 Cont roller Card LED Descript ions LED Color Displ ay and Description Alar m (MFC- 8310) Re d When lit, an alarm condition is occurring in th e frame.
Page 30 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Remote Control Netw orking Fea tures This secti on inclu des instruct ions f or installing the MFC-8310- N controller card for th e CFM-8310 modu le.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 31 of 40 • Monitors f r ame pow er usage an d sets the fan s p eed accordingly (h igher power con sumption req uires higher fan speed for ad e quate c o oling).
Page 32 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) DIP Switches on the M FC-8310-N The follow ing DIP Sw itches are located on the MFC -8310-N controlle r card. DIP_1 Switch DIP_1 switch disables the audio alarm signal as follow s: • ON — This setting disables the au dio alarm.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 33 of 40 Table 4. MFC-8310-N Cont roller Card LED Descript ions LED Color Location Di splay and Descri pt ion Alar m (MFC- 8310-N) Red DS1 When lit, an alarm condition is occurrin g in the fram e. Status OK (MFC- 8310-N) Green DS2 When lit, the fan control process is operating correctly.
Page 34 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Enabling SNMP You m ust obtain a l icense k ey from Cobalt Digit al Inc. to en able SNMP support. Use the follow ing procedure to obtain your licen se key: 1. Reques t a license key from you r distributor or at sales@cobaltdigital.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 35 of 40 Rear Support Bars and Brackets Under normal con ditions, moun ting the fram e to the front of the rack with four rack screw s should be suff icient to carry the load, in cluding the w eight of accom p anying cables .
Page 36 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Service Information In This Ch apter This chapter contain s the follow ing sections : • Troubleshoot ing Check list • Frame Cont roller .
8310 Us er Ma nu al • • • • (V 1.0.1) Page 37 of 40 Use the follow ing procedure to reload th e softw are: 1. Eject the card. 2. Press and hold the Alarm Mute/Bo otload button, w hile re-ins erting the card into the frame. 3. Release the bu tton.
Page 38 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Ordering Information In This Ch apter Your 8310 op enG ea r TM Two Rack Unit F rame and Pow er Supply (PS-8300) is a part of the openGear TM fam ily of products.
8310 Us er Ma nu al • • • • (V 1.0.1) Page 39 of 40 Notes:.
Page 40 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Contact Us Contact Cobalt Digita l Inc. General Business Office and Technical Support 217.344.1243 PHONE Fax 217.344.1245 General Information Info@cobaltdigital.com E-MA I L Sales Information Sales@cobaltdigital.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Cobalt Networks PS-8300 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Cobalt Networks PS-8300 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Cobalt Networks PS-8300, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Cobalt Networks PS-8300 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Cobalt Networks PS-8300, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Cobalt Networks PS-8300.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Cobalt Networks PS-8300. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Cobalt Networks PS-8300 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.