Manuel d'utilisation / d'entretien du produit s8300 du fabricant 2Wire
Aller à la page of 22
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 1 IP Enabling Siemens Hicom 300 With Avaya Solutions Running MultiVantage™ Software.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 2 1. Introduction: The configuration shown in figure 1 illustrates a PRI Trunk Connec.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 3 2. Equipment and Software Validated: The configuration used to test performance of .
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 4 Software : 1. Recommended Siemens Hicom 300. Release 9006.5 or newer. 2. Firmware for the boards and phones are included in the core software.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 5 Figure 2a . MM710 DS1 Circuit Pack Administration Figure 2b .
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 6 Trunk Group: Create a Trunk Group and select “isdn” as the Group Type and a TAC number based on your switches dial-plan. Ensure “PRI/BRI” is the Carrier Medium, this is used for ISDN trunks.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 7 Trunk Group Members: Assign trunk ports to the Trunk Group.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 8 Determine If System Has Capacities: <dis-dimen; (Displays System Dimensions) TYP.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 9 Adding a TNDN64 T-1 Board: <add-bcsu BOARD = ? BOARD : SPECIFY BOARD TYPE CHARAC.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 10 ACKTIM = ? ACKTIM : ACKNOWLEDGEMENT TIMER CHARACTERISTIC : OPTIONAL POSSIBLE VALUE.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 11 SET UP - OUT OF SERVICE (NPR) H6 : THE CIRCUIT WAS ADDED TO THE REFERENCE CLOCK TABLE. H19 : WHEN FCTID IS NOT ENTERED, OR FCTID=0 IS ENTERED FOR A TMDN, IT WILL CONFIGURE A TMDN WITH THE DEFAULT FCTID=1.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 12 Add Trunk Group Access Codes: <add-tgacc TGRP = 100 SATOPS = ? SATOPS : SATOPS .
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 13 CFBLOCK = ? CFBLOCK : CALL FORWARD BLOCKING CHARACTERISTIC : OPTIONAL POSSIBLE VAL.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 14 Display COP (Class of Parameters): <dis-cop; DIS-COP:,,; H500: AMO COP STARTED .
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 15 Add COS (Class of Service): <add-cos COPYCOS = NEWCOS = 100 AVCE = ? AVCE : ADD.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 16 MDR MESSAGE/CALL DETAIL RECORDING ORIGONLY ORIGINATE ONLY TERMLPBK DATA REMOTE TER.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 17 Display COS (Class of Service): <dis-cos:all; H500: AMO COS STARTED +------+---.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 18 TCCID = ? TCCID : TELEPHONE COMPANY CIRCUIT IDENTIFICATION CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : MAX.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 19 COSNO = 1 DEDSVC = ? DEDSVC : DEDICATED SERVICE FOR PRIB TRUNKS CHARACTERISTIC : O.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 20 Modify D-Channel from Default: <cha-tcsu PEN = 1-1-73-24 COTNO = COPNO = DPLN =.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 21 D10036 NTI DMS-100(RELEASE BCS-36) D10037 NTI DMS-100(RELEASE BCS-37/LEC-03- FUTUR.
Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 22 Display Trunk Members: <dis-tscu PEN1 = 1-1-73-24; H500: AMO TCSU STARTED +----.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté 2Wire s8300 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du 2Wire s8300 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation 2Wire s8300, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le 2Wire s8300 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le 2Wire s8300, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du 2Wire s8300.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le 2Wire s8300. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei 2Wire s8300 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.