2 Important The CD A Group L td cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that CD A reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment.
3 IMPORT ANT INFORMA TION FOR CORRECT DISPOSAL OF THE PRODUCT IN A CCORD ANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services.
4 Using your Extractor R emote Control A - LED lights B - “Plus” button C - “Light” button D - “Power” button E - “Clock” button F - “Minus ” button A E D C B F Fig.
5 T o switch the extractor on or o: • Press the “P ower” button “D” once . After switching on the motor will automatically start at the lowest speed setting. Setting the extractor speed when it is running: The extractor may run at a choice of 4 speeds, indicated by the LED lights on the remote control.
6 Care and Maintenance IMPORT ANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRA CT OR WITHOUT FIRST SWIT CHING OFF THE ELECTRICITY SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface.
7 T o remove the aluminium grease filters for cleaning • While supporting the weight of the lower half of the globe, use the special tool supplied with the appliance to unscrew the metal ring that secures it (Fig. 2). • Place the lower half of the globe, chrome lower cover and locking ring aside safely .
8 Changing the charcoal filter (Filter part number CHA30) T o ensure best performance of your extractor , you should replace the charcoal filter every four to six months, depending on use. T o replace the charcoal filters: • The charcoal filters are removed as part of the grease filter cleaning process described on the previous page.
9 If your extractor is not working: 1. Check that the mains supply has not been switched o . 2. Check that the fuse in the spur has not blown. 3. There is a hidden on/o switch inside the body of the globe. Ensure that this has not been accidentally switched o during installation or maintenance.
10 The LED and Neon Lamps The LED lamps (3S10BL) and neon light tubes (3S10WH) are long-life items that are not designed to be replaced by the user . In the unlikely event of a lamp failure, contact CD A Customer Care for assistance.
11 • The wire which is coloured green and yellow must be connected to the terminal marked “E” (Earth) or coloured green. • The wire which is coloured blue must be connected to the terminal marked “N” (Neutral) or coloured black.
12 Mounting Y our Extractor This appliance is designed to recirculate air only , under no circumstances should it be connected to any ductwork or external venting system. When installing this appliance over a CD A hob, the clearance between the extractor and the hob must be equal to or ex ceed 650mm.
13 Installation 1. Thread the safety cable upward through the small hole in the ceiling plate then downward through the centre boss. Pull this tight so the end nipple rests against the ceiling plate (Fig. 6). 2. P ass the fix ed wiring from the ceiling through the large hole in the ceiling plate (shown as “ A ” in Fig.
14 2. R emove the chrome cover from the top of the sphere, then remove and discard the cylindrical packing piece from the top bracket within it (Fig. 8). 3. P ass the power cable that exits the appliance up through the central bracket within the sphere (Fig.
15 6. Select the smaller diameter hanging tube and pass it through the ceiling rose cover . Note that the end of the hanging tube with holes in it needs to be upper-most (Fig. 13). 7 . Thread the power cable from the sphere upward through the smaller diameter hanging tube.
16 Fig. 16 Fig. 17 Fig. 19 10 . With a second person supporting the weight of the sphere, thread the safety cable down the tube assembly (Fig. 16) so it exits within the top cavity of the sphere (Fig. 17). 11. Insert the top tube into the ceiling bracket and secure it with two supplied through-bolts and nuts (Fig 18).
17 11. With an assistant supporting the weight of the sphere, adjust the height by sliding the outer hanging tube up or down the inner one (Fig. 20). 12 Fix the height adjustment by locking the three grubscrews on the tube joining-piece (shown as in Fig.
18 Notes:.
19 E & O E. All instructions, dimensions and illustrations are provided for guidance only . CDA reserve the right to change specifications without prior notice.
Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www. cda.eu www .cda.eu Please contact our Customer Care Department for Service on the details below Customer Care Department The Group L td.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté CDA 3S10 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du CDA 3S10 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation CDA 3S10, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le CDA 3S10 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le CDA 3S10, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du CDA 3S10.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le CDA 3S10. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei CDA 3S10 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.