81441001R8-3/06 Price - $2.00 R O F L A U N A M N O I T A L L A T S N I M A H N R U B A R - E S A BY ® PA G E 2 I=B=R RA TINGS 4 ASSEMBL Y CHAR T 5 SYSTEM TYPES 6 SERIES L OOP SYSTEMS 7 SERIES L OOP .
2 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. No. 9A Base-Ray ® I=B=R Ratings – Steam and Hot W ater ( 500 LBS/HR Flow Rate **.
3 For Ratings at the following temperatures, multiply the 150° rating by the multiplier of the desired temperature. T emperature – Multiplier 150° - 1.
4 Dimensions and Speci ¿ cations BASE-RA Y T APPINGS- T apped 3/4" top and bot- tom of end sections. A 3/4" x 1/8" vent bushing is furnished with each Base-Ray Assembly .
5 BASE-RA Y ® HYDRONICS T ypes of Systems Hydronic Heating Systems are classi ¿ ed according to the pip- ing arrangement and heating medium employed. BASE-RA Y is very versatile in that it may be used in almost all types of systems as noted below: 1.
6 SERIES LOOP SYSTEMS Installation Data This type of installation, in which the BASE-RA Y ® Assem- blies serve as part of the main, is the most economical way BASE-RA Y can be installed. Substantial savings in labor and material are realized in that one-pipe ¿ ttings, shut-of f valves, balancing cocks and additional piping are eliminated.
7 T o Design Series-Loop Base-Ray ® Installation – 1. Calculate the Heat Loss of each room using the procedure outlined in the I=B=R Heat Loss Calculation Guide No. H-21 or the ASHRAE Guide. 2. Using 210°F as design water temperature and 500 lbs/hr .
8 Installation Details A BASE-RA Y ® heating system is extremely easy to install – no other heating system requires less labor . The same installa- tion practices that are used in an ordinary radiator system are followed. Use conventional methods in selecting boiler and pipe sizes, including mains, risers and branches.
9 INST ALLA TION INSTRUCTIONS 1. W all Preparation: T o prevent excessive heat loss through the walls in back of BASE-RA Y ® , it is recommended that the stud space behind the Assemblies be insulated.
10 5. Assembling BASE-RA Y ® BASE-RA Y is shipped assembled in lengths up to six (6) lineal feet – longer assemblies are shipped in two or more sub-assemblies for assembly on the job (see BASE-RA Y Assembly chart, page 4).
11 Stand Assemblies upright, place in position and fasten to the walls with T op Center Supports using the number shown in the table above. Insert T op Center Supports in Air Outlet opening of Sections opposite studs (stud locations determined in step 1).
12 8. Installation of Corner Plates INVER TED CORNER PLA TES – for inside corners – furnished in two types, 4-5/8” standard plate is used when Assemblies on adjoining walls extend to within 4-3/8” of the corner . If this distance is greater than 4-3/8” but less than 10-3/8”, the 10-5/8” plate is used.
13 ADJUST ABLE END CAPS & FILLER PIECES – Adjustable End Caps are available in both left-hand and right-hand patterns and are used in the same loca- tions as the standard end caps except the 9” length of the adjustable end caps makes it possible to ¿ ll in spaces of up to 7-1/2”.
14 SPECIAL APPLICA TIONS BASE-RA Y ® INST ALLED ON THREE W ALLS OF ROOM – When BASE-RA Y is installed on three walls, expansion noises are sometimes created by the middle assembly when rigid piping is used to connect all three assemblies together .
15 All Base-Ray® repair parts may be obtained through your local Burnham Wholesale Distributor . Should you require assistance in locating a Burnham Distributor in your area, or have questions regarding the availability of Burnham products or repair part s, please contact Burnham Customer Service at (717) 481-8400 or Fax (717) 481-8408.
Limited W arranty – Except as provided below with respect to products or parts not manufactured by U.S. Boiler Co., Inc. U.S. Boiler Co., Inc. warrants to the original owner at the original installation site that products manufactured by U.S. Boile r Co.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Burnham BASE-RAY 81441001R8-3/06 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Burnham BASE-RAY 81441001R8-3/06 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Burnham BASE-RAY 81441001R8-3/06, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Burnham BASE-RAY 81441001R8-3/06 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Burnham BASE-RAY 81441001R8-3/06, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Burnham BASE-RAY 81441001R8-3/06.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Burnham BASE-RAY 81441001R8-3/06. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Burnham BASE-RAY 81441001R8-3/06 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.