Manuel d'utilisation / d'entretien du produit 1xN du fabricant ADTRAN
Aller à la page of 12
1 61190860L1-5B Section 61190860L1-5, Issue 2 CONTENTS 1. GENERAL ................................................................ 1 2. INSTALLATION ....................................................... 3 3. CONFIGURATION ...........................
2 61190860L1-5B Section 61190860L1-5, Issue 2 The SCIM can be locally powered by -48 VDC, or span powered from the standby unit in slot 8 if equipped for span power. Slide switch S1 selects between local or span power. CPE receive and transmit connections are either amphenol or RJ-48C jacks.
3 61190860L1-5B Section 61190860L1-5, Issue 2 Documentation associated with the listed cards provides information on implementing the auto-protect function. LED Indication Table 1 describes LED indication. • All LEDs OFF indicates no power to the SCIM.
4 61190860L1-5B Section 61190860L1-5, Issue 2 Wire-Wrap – The to-facility and from-facility wire-wraps are an alternate method in lieu of the amphenol connections. Customer Side Amphenol Connection – The to-CPE and from-CPE amphenols should be left-side oriented to prevent SCIM panel removal interference after amphenol installation.
5 61190860L1-5B Section 61190860L1-5, Issue 2 Span Power Switch S1 This switch selects between span power or local power. SP AN – The SCIM receives power from the protect card in slot 8. LOCAL – The SCIM receives power from local -48 VDC to terminal strip TB1 on the SCIM card.
6 61190860L1-5B Section 61190860L1-5, Issue 2 the controller card. The controller card will continuously monitor the network receive T1 transmission service in slot 8 (i.
7 61190860L1-5B Section 61190860L1-5, Issue 2 Table 2. In-Band Commands d n a m m o C x e H n r e t t a P n r e t t a P y r a n i B g n i m r A h c t i w S0 4 4 C0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 1 e l b .
8 61190860L1-5B Section 61190860L1-5, Issue 2 7. PROTECTION SWITCH Remote provisioning for a protection switch can be accomplished by sending a specific sequence of in-band or out-of-band messages. These remote provisioning commands are transmitted to the controller card from a remote test facility or a T1 test set at a DSX panel.
9 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Protection Switch Protocol See T able 5 for in-band protection switch protocol. Out-of-Band Enable/Disable Protocol See Table 6 for out-of-band slot enable/disable protocol. Out-of-Band Protection Switch Protocol See Table 7 for out-of-band protection switch protocol.
10 61190860L1-5B Section 61190860L1-5, Issue 2 See Figure 5 and Figure 6 for switchover codes and traffic results. 8. SWITCHBACK Switchback operation is defined as the re-establishment of the T1 transmission path between the network and the customer using the regularly assigned line.
11 61190860L1-5B Section 61190860L1-5, Issue 2 In-band Release Protocol See Table 8 for return to normal operation. Out-of-Band Release Protocol See Table 9 for return to normal operation. Signal Transmit The controller card will transmit a 0 dB signal.
12 61190860L1-5B Section 61190860L1-5, Issue 2 10. SPECIFICATIONS See Table 10 for Specifications. Table 10. Specifications n o i t a c i f i c e p S : e c a f r e t n I l a c i s y h Pe r i W - 4 : l.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ADTRAN 1xN c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ADTRAN 1xN - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ADTRAN 1xN, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ADTRAN 1xN va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ADTRAN 1xN, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ADTRAN 1xN.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ADTRAN 1xN. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ADTRAN 1xN ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.