B UNN ® OPERA TING & SER VICE MANU AL BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 28791.0001B 1/00 ©1998 Bunn-O-Matic Corporation AF PR-2 AF PR-3 AFPR-3 VERSION DISCONTINUED The information in this manual is no longer current.
2 INTRODUCTION This equipment supplies a premixed liquid product to the hoppers on the CDS-2 or 3 dispensers. It is for indoor use only on a sturdy counter or shelf.
3 INITIAL SET -UP NOTE: This refill unit should not be used to initially fill the hopper . Running the motor for extended periods will trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time. NOTE: Hoses, clamps and product container connectors are not supplied.
4 CLEANING RECOMMENDED WEEkL Y CLEANING: This should be done in conjunction with the recommended weekly cleaning of your CDS-2 or CDS-3 machine. The CDS Hoppers must be empty before starting. 1. Prepare a 1 gallon cleaning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 3-5% chlorine based sanitizer .
5 OPERA TING CONTROLS A. MAIN POWER ON/OFF The main power ON/OFF switch is located on the right of the front panel just above the power cord. B. REFILL CIRCUIT ON/OFF The refill circuit ON/OFF switches are located on the right of the front panel just above the main power switch.
6 PROBLEM 1. Empty product container 2. No power or incorrect voltage to the dispenser 3. Signal cable unplugged 4. Hopper is full 5. Fuse and fuse holder 6. Main ON/OFF switch 7. Probe box LOW/OFF/HIGH switch - es 8. Circuit board 9. Vacuum switches 10.
7 SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessar y .
8 Removal and Replacement: 1. Disconnect the ten pin plug from the main wiring harness to the circuit board. 2. Remove the six #4-40 screws and spacers securing the circuit board to the solenoid mounting bracket.
9 FIG. 4 FUSE HOLDER FUSE AND FUSE HOLDER P1561 Location: The fuse holder is located on the lower right front of the autofill box just to the left of the power cord. T est Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Remove cap and fuse from fuse holder .
10 Removal and Replacement:: 1. Remove the wires from the switch terminals. 2. Compress the clips inside the autofill box and gently push the switch through the opening 3. Push the new switch into the opening and spread the clips to hold switch in the autofill box.
11 FIG. 8 PROBE SWITCHES Probe Boxes: 1. Disconnect the signal cable from the probe boxes. 2. Remove probe box from CDS hopper . 3. Place the switch on the probe box in the “HIGH” position. 4. Check the resistance across the box cable pins, see Fig.
12 SERVICE (cont.) REFILL SWITCHES FIG. 12 REFILL SWITCHES Location: The refill switches are located on the upper right front of the autofill box. T est Procedures: 1. Disconnect the dispenser from the power sour ce. 2. Disconnect the two white/red, brown/black or red/ black wires from the switch terminals.
13 SERVICE (cont.) V ACUUM/SUPPL Y PUMP ASSEMBL Y FIG. 16 V ACUUM/SUPPL Y PUMP ASSEMBL Y P1560 Location: The vacuum/supply pumps are located inside the autofill box. T est Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Disconnect the white wire from the pump lead and the yellow , orange or red wire from the other lead.
14 SERVICE (cont.) V ACUUM/SUPPL Y PUMP TUBE INST ALLA TION 1. Separate the pump head from the pump body . Hold pump head as shown in Fig. 18, with roller in the 2, 6 10 o’clock positions. 2. Wrap tubing around rollers and hold as shown in Fig. 18. 3.
15 V ACUUM SWITCHES FIG. 16 V ACUUM SWITCHES Location: The vacuum switches are located inside autofill box, mounted on the left side of the mounting bracket. T est Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Disconnect flavor input lines.
16 28791.1 011500.
17 28791.1 011500.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bunn AF PR-3 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bunn AF PR-3 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bunn AF PR-3, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bunn AF PR-3 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bunn AF PR-3, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bunn AF PR-3.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bunn AF PR-3. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bunn AF PR-3 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.