


Broan-NuTone LLC. 926 West State Street, Hartford, WI 53027 NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 Broan-NuTone Canada, INC.1140 Tristar Drive, Mississauga, Ontario, L5T 1H9



SUITABLE FOR USE IN HOUSEHOLD COOKING AREA.
TO REDUCE THE RISK OF INJURY TO PER- SONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, con- tact the manufacturer at the address or tele- phone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ- ing fire-rated construction codes and stan- dards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chim- ney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety stan- dards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the out- doors. 7. Do not use this unit with any solid-state speed control device. 8. To reduce the risk of fire, use only steel ductwork. 9. This unit must be grounded.
guisher and you already know how to op- erate it. B. The fire is small and contained in the area
where it started. C. The fire department is being called. D. You can fight the fire with your back to an
exit. * Based on “Kitchen Fire Safety Tips” pub- lished by NFPA.
1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 5. To avoid motor bearing damage and noisy and/ or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking sur- face. 8. Two installers are recommended because of the large size and weight of this hood. 9. Please read specification label on product for further information and requirements.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or
when cooking flaming foods. C. Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate
for the size of the surface element.

Unpack hood and check contents. You should receive: 1 - Hood 1 - Parts Bag (B080810168) containing: 4 - Mounting Screws (3,2 x 13mm) 1 - Installation Instructions 4 MOUNTING SCREWS (3,2 x 13mm)
This product is designed for use with the 331H, 332H, 335 or 336 Exterior Ventilators. The exterior ventilator must be UL listed for Canadian and U.S. use, and evaluated for use with solid state speed control rated 120V, 60 Hz, 6.0 A max.

BLOWER 10” ROUND DUCT
8” TO 10” ROUND ADAPTER
metal ductwork.
1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a exterior blower. Connect round metal ductwork to exterior blower and work back towards hood location. Use duct tape to seal the joints between ductwork sections. 5. An 8” to 10” transition (Model 414) will be necessary to connect to the exterior ventilator. It is reccommended that the transition be installed as near to the hood as possible.
EXTERIOR
BLOWER
HOOD
24” TO 30” ABOVE COOKING SURFACE
10” ROUND
DUCT
8” ROUND ELBOW


1. Remove the grease filters by pushing filter towards the back of hood and rotating filter downward. 2. Remove the metal grille by moving the 2 side fasteners. 3. Cut a hole in the bottom of the cabinet, using the dimensions shown. 4. Adjust the position of the clasping side spring by means of the proper screw, according to the thickness of the panel to which it is going to be anchored. 5. Insert the hood in the cabinet and lock it by means of the side spring. 6. Use the holes in the casing of the hood to attach it using 4 mounting screws. 7. Replace grille and filters.

THE CABINET
MOUNTING SCREWS


min 7-16” max 13/16”

10-1/4” · 26-5/8”

Connection the hood to the

WIRING BOX FOR
WIRING BOX FOR
COVER (A)
THE ELECTRICAL
THE EXTERIOR
CONNECTION
BLOWER

Electrical connections: 1. Remove the wiring box cover (B). Remove a knockout from the wiring box. 2. Feed 6" of power cable through the knock- out opening and secure cable to the wiring box with an appropriate connector. 3. Make electrical connections. Connect white to white, black to black and green to green. 4. Replace wiring box cover and screws. Make sure that wires are not pinched between cover and box.

COVER (B)
exterior blower · Exterior blower


Proper maintenance of the Range Hood will assure proper performance of the unit.
Grease Filters The grease filters should be cleaned fre- quently. Use a warm detergent solution. Grease filters are dishwasher safe. Remove filter by pushing filter towards the back of hood and rotating filter downward.
Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:
BLOWER
SWITCH
Controls The hood is operated using the slide controls under the bottom of the hood.
The light switch turns the lamps on and off.
The blower switch:makes it possible to select the motor operating speed. Position 0: motor off.
The pilot lamp lights up whenever the blower is on.


This range hood requires two halogen bulbs (Type T4, 12V, 20W). ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.
To change bulbs:
SWITCH OFF THE ELECTRICITY SUPPLY.

Remove the grease filters.
Open the fuse box.
Replace with the same type of fuse (5x20mm, 4A, 125V).

BROAN-NUTONE LLC ONE YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WAR- RANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNEC- TION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone LLC at the address stated below or telephone: 1-800-637- 1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC. 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) Broan-NuTone Canada, Inc. 1140 Tristar Drive, Mississauga, Ontario, L5T 1H9 (1-888-882-7626)
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.