FR
Broan logo
Notice d'utilisation officielle

Broan RM533604

40 pages·1.3 MB·Cuisinière·PDF·ENDEITNLJA
Broan RM533604
Table des matières 68 sections RM53000 Series · READ AND SAVE THESE INSTRUCTIONS · ! INTENDED FOR DOMESTIC COOKING ONLY ! · WARNING · … AfficherMasquer
Page 1 of the Broan RM533604 user manual — ENGLISH....................................2 FRANÇAIS...............................16 ESPAÑOL.................................30
Page 1 · cliquer pour agrandir
Page 1
Broan RM533604 — RM53000 Series diagram (page 1)
Fig. 1 · RM53000 Series

RM53000 Series

ENGLISH 2 FRANÇAIS 16 ESPAÑOL 30

In USA - BROAN Hartford, Wisconsin In CANADA - BROAN Drummondville, QC, Canada

REGISTER YOUR PRODUCT ONLINE ATwww.Broan.com/register

For additional Information visit www.Broan.com

Page 2 of the Broan RM533604 user manual — RM53000 Series
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Broan RM533604 user manual — RM53000 Series
Page 3 of the Broan RM533604 user manual — WARNING
Page 3 · cliquer pour agrandir
Page 3

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accor- dance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any separate solid-state speed control device. 8. To reduce the risk of fire, use only metal ductwork. 9. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings. Boilovers cause smoking and

greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes

Suzette, Cherries Jubilee, Peppercorn Beef Flambe’). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or

filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface

element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you already know how to operate

it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

Page 4 of the Broan RM533604 user manual — READ AND SAVE THESE INSTRUCTIONS
Page 4 · cliquer pour agrandir
Page 4

! CAUTION 1. For indoor use only. 2. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 3. Take care when using cleaning agents or detergents. 4. Avoid using food products that produce flames under the Range Hood. 5. For general ventilating use only. Do not use to exhaust hazardous or explosive materi- als and vapors. 6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 7. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 8. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. 9. Two installers are recommended because of the large size and weight of this hood. 10. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 11. Please read specification label on product for further information and requirements.

Page 5 of the Broan RM533604 user manual — 8 DRYWALL ANCHORS
Page 5 · cliquer pour agrandir
Page 5

Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag (B080810501) containing: 1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 8 - Mounting Screws (4,8 x 38mm Pan Head) 6 - Mounting Screws (3,9 x 9,5mm Pan Head) 8 - Drywall Anchors 1 - Installation Instructions

Broan RM533604 — MOUNTING BRACKET diagram (page 5)
Fig. 2
Broan RM533604 — MOUNTING BRACKET diagram (page 5)
Fig. 3

MOUNTING BRACKET

DECORATIVE FLUE

6 MOUNTING SCREWS (3,9 x 9,5mm Pan Head)

DISCHARGE COLLAR

Broan RM533604 — DISCHARGE COLLAR diagram (page 5)
Fig. 4

8 DRYWALL ANCHORS

FLUE MOUNTING BRACKET

8 MOUNTING SCREWS (4,8 x 38mm Pan Head)

Page 6 of the Broan RM533604 user manual — DECORATIVE
Page 6 · cliquer pour agrandir
Page 6

INSTALL THE DUCTWORK (DUCTED HOODS ONLY)

ROOF CAP

Broan RM533604 — ROOF CAP diagram (page 6)
Fig. 5

metal ductwork.

ROUND DUCT

1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap. Connect round metal ductwork to cap and work back to- wards hood location. Use duct tape to seal the joints between ductwork sections.

DECORATIVE

WALL

FLUE

CAP

HOOD

ROUND ELBOW

6” ADAPTER

24” TO 30” ABOVE COOKING SURFACE

WIRING

Broan RM533604 — DECORATIVE diagram (page 6)
Fig. 6

Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING - Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance. Set the electrical power supply within the space covered by the decorative flues. Position the power socket at a maximum distance of 33-7/16” (85 cm) from where the lead exits from the hood (see illustration alongside). Make sure this does not interfere with the bracket fastening area or with the decorative flue (where the flue touches the wall). Fit the plug into the power socket.

Page 7 of the Broan RM533604 user manual — SYSTEM
Page 7 · cliquer pour agrandir
Page 7

INSTALL MOUNTING BRACKET

FRAMING BEHIND DRYWALL

Broan RM533604 — FRAMING BEHIND DRYWALL diagram (page 7)
Fig. 7
1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure: a) the framing is centered over

37-7/16” to 43-7/16” above cooktop

installation location. b) the height of the framing will allow the

mounting bracket to be secured to the framing within the dimensions shown.

37-7/16"= bottom of hood 24" above cooktop 43-7/16"= bottom of hood 30" above cooktop

2. After wall surface is finished, secure mounting bracket to framing using dimensions shown.

INSTALL FLUE MOUNTING BRACKET

FLUE MOUNTING

BRACKET

3.9 x 6 mm FLAT HEAD BRACKET SCREWS

DUCTED AND NON-DUCTED

1. Assemble the flue mounting bracket, adjusting outside width as shown. Fig.4
2. Carefully center the mounting bracket directly over the range hood location.

9-13/16” (249.8mm)

3. Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors. Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood.

MOUNT THE PLATE

MOUNTING SCREWS

PLATE OF

(3.9x9.5mm)

THE ELECTRICAL

Broan RM533604 — THE ELECTRICAL diagram (page 7)
Fig. 8

Mount the plate of the electrical system attaching it with (2) mounting screws (3.9x9.5mm).

SYSTEM

Page 8 of the Broan RM533604 user manual — UPPER
Page 8 · cliquer pour agrandir
Page 8
Broan RM533604 — 6” DIAMETER diagram (page 8)
Fig. 9

6” DIAMETER

DUCT

DISCHARGE

COLLAR

DUCTED CONFIGURATION

DUCT CONNECTOR

1.Install the discharge collar into the duct connector of the range hood. Fig. 6

2.Attach an adequate length of 6” round steel ducting to the range hood duct connector. Fig. 6

3.Duct tape all joints to make them secure and air tight.

4.Carefully place the lower decorative flue into the recessed area of the range hood top. Fig. 7

UPPER

Broan RM533604 — UPPER diagram (page 8)
Fig. 10

UPPER FLUE

FLUE VENTS EXPOSED

5.Carefully slide the upper decorative flue down inside the lower flue. Fig. 7

LOWER FLUE

UPPER

FLUE VENTS CONCEALED

On 9” ceilings, air vents on the upper flue will be exposed after installation.

Page 9 of the Broan RM533604 user manual — COLLAR
Page 9 · cliquer pour agrandir
Page 9

NON - DUCTED CONFIGURATION

  • Non - Ducted Recirculation Kit, Model RRK51
  • 1/16” diameter twist drill.

1.Discard discharge collar and damper supplied with the hood. Install the 5” to 6” adapter supplied with the Non-Ducted Recirculation Kit. Fig. 8.

Broan RM533604 — NON - DUCTED CONFIGURATION diagram (page 9)
Fig. 11

PLENUM

(3) SCREWS

2.Measure the distance “A”.

5” ALUMINUM FLEX DUCT

3.Attach aluminum flexible duct to the 5” adapter. Tape all joints with duct tape. Fig. 8.

A

5” 6” ADAPTER

4.Assemble the recirculation plenum to the flexible duct. Fig. 8.

BLOWER

5.Drill three (3) 1/16” diameter equally spaced holes through the duct and duct connector of the recirculation plenum. Fig.8.

COLLAR

6.Secure duct to the plenum’s connector with (3) sheet metal screws. Tape all joints with duct tape. Fig. 8.

Page 10 of the Broan RM533604 user manual — RECTANGULAR
Page 10 · cliquer pour agrandir
Page 10
Broan RM533604 — 4 FLAT HEAD SCREWS UPPER diagram (page 10)
Fig. 12

PLENUM

NON - DUCTED CONFIGURATION, cont’d.

8. Carefully place the lower decorative flue into the recessed area of the range hood top. Fig. 7
9. Carefully slide the upper decorative flue down inside the lower flue. Note: air vents must be up. Fig. 7

4 FLAT HEAD SCREWS UPPER

10.Secure the recirculation plenum to the upper flue with (4) flat head screws. Fig. 9

FLUE

INSTALL THE HOOD

MOUNTING

WALL FRAMING

Broan RM533604 — FLUE diagram (page 10)
Fig. 13

SCREWS (4.8x38mm)

SCREWS (3.9x9.5mm)

MOUNTING

SCREWS (4.8x38mm)

MOUNTING

BRACKET

1. Raise the hood into its mounting position.
2. Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue.

RECTANGULAR

CUTOUT

3. Align the rectangular opening on the back of the hood with the wall-mounting bracket. Gently lower the hood until it securely engages the bracket. Fig. 10

3.9x9.5mm MOUNTING SCREWS

4. Level the hood with 2 screws (3.9x9.5mm) and secure with (4) mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 10
Broan RM533604 — RECTANGULAR diagram (page 10)
Fig. 14
5. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 11
6. Secure the flue with (2) mounting screws. Fig. 11
Page 11 of the Broan RM533604 user manual — CLAMP
Page 11 · cliquer pour agrandir
Page 11

NON-DUCTED RECIRCULATION FILTER INSTALLATION

Broan RM533604 — NON-DUCTED RECIRCULATION FILTER INSTALLATION diagram (page 11)
Fig. 15
1. Purchase a non-ducted recirculation filter (B03300488) from your dealer.
2. Install the filter by pressing the 2 tabs on the filter down into the special housing and rotating upward. NON-DUCTED RECIRCULATION

FILTER

MAINTENANCE

Broan RM533604 — FILTER diagram (page 11)
Fig. 16

Proper maintenance of the Range Hood will assure proper performance of the unit.

Grease Filters The grease filters should be cleaned fre- quently. Use a warm detergent solution. Grease filters are dishwasher safe. Remove filter by pushing filter towards the back of hood and rotating filter downward.

GREASE FILTERS

Broan RM533604 — GREASE FILTERS diagram (page 11)
Fig. 17

Non-ducted recirculation Filter The non-ducted recircualtion filter should be changed every 6 months. To remove the filter press inward on the clamp and rotate the filter downward until the 2 tabs can be removed from the housing.

TABS

Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help pre- serve its fine appearance. Cleaning tips:

CLAMP

  • Hot water with soap or detergent is all that is usually needed.
  • Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
  • For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth.
  • For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.
  • DO NOT allow deposits to remain for long periods of time.
  • DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
  • DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth. Painted surfaces should be cleaned with warm water and mild detergent only.
Page 12 of the Broan RM533604 user manual — HALOGEN BULBS
Page 12 · cliquer pour agrandir
Page 12

OPERATION

LIGHT SWITCH

BLOWER

Controls The hood is operated using the slide controls under the bottom of the hood.

SWITCH

PILOT

LAMP

The light switch turns the lamps on and off.

The blower switch:makes it possible to select the motor operating speed. Position 0: motor off.

The pilot lamp lights up whenever the blower is on.

HEAT SENTRY™ Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface. 1) If blower is OFF - it turns blower ON to HIGH speed. 2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

HALOGEN BULBS

This range hood requires two halogen bulbs (Type G9, 120Volt, 25 Watt Max, G-9 Base). ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

Broan RM533604 — HALOGEN BULBS diagram (page 12)
Fig. 18

To change bulbs:

1. Remove the lamp lens cover by inserting a small flat-blade screwdriver into each of the three slots and gently prying it free. CAUTION: DO NOT REMOVE THE OUTER TRIM RING (LAMP ASSEMBLY). 2. Remove the bulb by pulling sideward(DO NOT ROTATE). CAUTION: BULB MAY BE HOT! 3. Replace with Type G9, 120Volt, 25 Watt Max, G-9 Base halogen bulb. Do not touch replacement bulb with bare hands!
Page 13 of the Broan RM533604 user manual — WARRANTY
Page 13 · cliquer pour agrandir
Page 13

WARRANTY

ONE YEAR LIMITED WARRANTY FOR BROAN PRODUCTS Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Broan products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCAN- DESCENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCT- ING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or instal- lation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or con- sequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

In USA - Broan®, 926 W. State Street, Hartford, WI 53027 (800-558-1711) In Canada - Broan®, 550 Lemire Blvd., Drummondville, QC J2C 7W9 (866-737-7770) www.Broan.com

Poser une question sur : Broan RM533604

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan RM533604

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan RM533604 manuel PDF

40 pages·1.3 MB·Cuisinière·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…