E64000 SERIES INTENDED FOR DOMESTIC COOKING ONL Y INST ALLER: LEA VE THIS MANU AL WITH HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P A GES 13 AND 14. Broan-NuT one LLC; Har tf ord, Wisconsin www .broan.com 800-558-1711 Broan-NuT one Canada; Mississauga, Ontario www .
W ARNING W ARNING - 2 - T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJUR Y TO PERSONS, OBSER VE THE FOLLO WING: 1. Use this unit only in the manner intended by the manuf acturer . If you hav e questions, contact the manuf acturer at the address or telephone number listed in the warranty .
HL0097 - 3 - RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL .) 8” R OUND A DJUST ABLE E LBOW M ODEL 412 T RANSITION (3¼” X 10” TO 7”) A DAPTER /.
- 4 - HL009 8 RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL ) E64000 SERIES HOOD - E64000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLO WERS 332KR.
- 5 - 1. SELECT BLOWER OPTION AND INST ALLA TION TYPE 1.2 D UCTED I NST ALLA TION The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blow ers (included with the hood), or hood using e xter nal blo wers.
- 6 - 2. PREP ARE THE INST ALLA TION Make sure that the f ollowing items are included: - Range hood - Accessories: • Baffle filters • Baffle filters handles (located inside the hood) • 3¼” x .
- 7 - 2. PREP ARE THE INST ALLA TION (CONT’D) Cut-out the openings f or duct ( A ) and power cab le ( B ), in cabinet or wall, according to the direction of discharge chosen.
- 8 - 4. REMOVE FIL T ERS AND GREASE DRIP RAIL A. Remov e tape on filters. Remov e filters from hood and set aside. NO TE: It is recommended to star t with the center one(s). B. Remov e tape on grease drip rail ( 1 ). Lift out grease drip rail and set aside.
- 9 - 6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONL Y) Remov e the knock out for the chosen opening(s) (horizontal at the bac k of the hood or vertical on top). See illustrations below . V ERTICAL DISCHARGE H ORIZONT AL DISCHARGE NO TE: F or ducted installation only .
- 10 - 7. HORIZONT AL DISCHARGE INST ALLA TION ( INTERNAL BLOWER(S) ONL Y) HD0271 Flip the blo wer and engage its flange in the back w all retaining brac ket. Using a 5/16” sock et and the screws pre viously remov ed, secure the blo wer to the hood.
- 11 - 10. INST ALL THE HOOD (ALL BLOWERS) HD0265 A B A B B INTERNAL BLO WER: Run power cab le to installation location. Place the hood in its location. Mar k the position of the scre ws (smaller par t of the ke y holes [ A ]) with a pen. Remov e the hood and install the (4) 1/2” doub le thread screws at marked positions , leaving a 1/8” gap.
- 12 - 13. INST ALL LIGHT BULBS This hood must use 120 V , 50 W , MR16 with GU10 base or P AR16 with GU10 base, shielded halogen lamps (not included). W ARNING In order to pre vent the risk of personal injury , do not install a lamp identified f or use only in enc losed fixtures.
- 13 - 15. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently . Use a war m detergent solution. W ash more often if your cooking style generates greater grease—lik e fr ying foods or w ok cooking. Remov e baffle filters by pushing them to wards the back of hood and rotating filters do wnward.
- 14 - 16. OPERA TION (CONT’D) HC00 3 5 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blow er switch 4) Blower speed control knob 2 3 1 4 HC00 3 4 A) Halogen light knob B) Blower speed control knob A B COOKT OP LIGHTING (HALOGEN) A rotar y 3-position knob ( 1 ) controls the halogen lights (OFF - low intensity - high intensity).
- 15 - 18. WIRING DIAGRAMS Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods LINE NEUTRAL GROUND 120 V AC WHT M BRN BLU RED BLK M BRN BLU RED B.
- 16 - 19. SER VICE P ARTS HL0104 Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods 6 7 14 17 * N OT SHO WN .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Broan P408ICAT c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Broan P408ICAT - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Broan P408ICAT, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Broan P408ICAT va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Broan P408ICAT, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Broan P408ICAT.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Broan P408ICAT. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Broan P408ICAT ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.