FR
Broan logo
Notice d'utilisation officielle

Broan K3139

36 pages·410 KB·Hotte de ventilation·PDF·ENDEITNLJA
Broan K3139
Table des matières 68 sections Model K3139 · READ AND SAVE THESE INSTRUCTIONS WARNING · WARNING · CAUTION · … AfficherMasquer
Page 1 of the Broan K3139 user manual — ENGLISH......................................3 FRANÇAIS................................12 ESPAÑOL..................................21
Page 1 · cliquer pour agrandir
Page 1
Broan K3139 — Model K3139 diagram (page 1)
Fig. 1 · Model K3139
Broan K3139 — Model K3139 diagram (page 1)
Fig. 2 · Model K3139

Model K3139

ENGLISH 3 FRANÇAIS 12 ESPAÑOL 21

BEST BY BROAN P.O. Box 140, Hartford, WI 53027

Page 2 of the Broan K3139 user manual — Model K3139
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Broan K3139 user manual — Model K3139
Page 3 of the Broan K3139 user manual — CAUTION
Page 3 · cliquer pour agrandir
Page 3

READ AND SAVE THESE INSTRUCTIONS WARNING

WARNING

SUITABLE FOR USE IN HOUSEHOLD COOKING AREA.

TO REDUCE THE RISK OF INJURY TO PER- SONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extin-

1. Use this unit only in the manner intended by the manufacturer. If you have questions, con- tact the manufacturer at the address or tele- phone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, includ- ing fire-rated construction codes and stan- dards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chim- ney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety stan- dards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the out- doors. 7. Do not use this unit with any solid-state speed control device. 8. To reduce the risk of fire, use only steel ductwork. 9. This unit must be grounded.

guisher and you already know how to op- erate it. B. The fire is small and contained in the area

where it started. C. The fire department is being called. D. You can fight the fire with your back to an

exit. * Based on “Kitchen Fire Safety Tips” pub- lished by NFPA.

CAUTION

1. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 2. Take care when using cleaning agents or detergents. 3. Avoid using food products that produce flames under the Range Hood. 4. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 5. To avoid motor bearing damage and noisy and/ or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 6. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 7. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking sur- face. 8. Two installers are recommended because of the large size and weight of this hood. 9. Please read specification label on product for further information and requirements.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings.

Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or

when cooking flaming foods. C. Clean ventilating fans frequently. Grease should not

be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate

for the size of the surface element.

Page 4 of the Broan K3139 user manual — 8 DRYWALL ANCHORS
Page 4 · cliquer pour agrandir
Page 4

PREPARE THE HOOD

Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag containing: 1 - Mounting Bracket 1 - Discharge Collar 1 - Flue Mounting Bracket 8 - Mounting Screws (4,8 x 38mm Pan Head) 2 - Mounting Screws (3,9 x 9,5mm Pan Head) 8 - Drywall Anchors 1 - Installation Instructions 1 - Warranty Card

Broan K3139 — PREPARE THE HOOD diagram (page 4)
Fig. 3
Broan K3139 — PREPARE THE HOOD diagram (page 4)
Fig. 4

DECORATIVE FLUE

MOUNTING BRACKET

2 MOUNTING SCREWS (3,9 x 9,5mm Pan Head)

DISCHARGE COLLAR

Broan K3139 — DISCHARGE COLLAR diagram (page 4)
Fig. 5

FLUE MOUNTING BRACKET

8 MOUNTING SCREWS (4,8 x 38mm Pan Head)

8 DRYWALL ANCHORS

Page 5 of the Broan K3139 user manual — MOUNTING
Page 5 · cliquer pour agrandir
Page 5

INSTALL THE DUCTWORK

Broan K3139 — INSTALL THE DUCTWORK diagram (page 5)
Fig. 6

ROOF CAP

metal ductwork.

ROUND DUCT

1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap. Connect round metal ductwork to cap and work back to- wards hood location. Use duct tape to seal the joints between ductwork sections.

DECORATIVE

WALL

FLUE

CAP

HOOD

ROUND ELBOW

24” TO 30” ABOVE COOKING SURFACE

6” ADAPTER

INSTALL MOUNTING BRACKET

FRAMING BEHIND DRYWALL

Broan K3139 — DECORATIVE diagram (page 5)
Fig. 7
1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure: a) the framing is centered over installation

37-7/8” to 43-7/8” above cooktop

location. b) the height of the framing will allow the

mounting bracket to be secured to the framing within the dimensions shown.

37-7/8"= bottom of hood 24" above cooktop 43-7/8"= bottom of hood 30" above cooktop

2. After wall surface is finished, secure mounting bracket to framing using dimensions shown.

INSTALL THE HOOD

WALL FRAMING

Broan K3139 — WALL FRAMING diagram (page 5)
Fig. 8

MOUNTING

SCREWS

1. Hang the hood from the bracket through the rectangular cut-out on the back of the hood. Cutout is larger than the bracket to allow for horizontal adjustment. The bottom of the hood should be 24" to 30" above the cooking surface. 2. Secure the hood with mounting screws . Use drywall anchors, provided, if wall studs or framing are not available.

MOUNTING

SCREWS

MOUNTING

BRACKET

RECTANGULAR

CUTOUT

Page 6 of the Broan K3139 user manual — WIRING
Page 6 · cliquer pour agrandir
Page 6

WIRING

Broan K3139 — WIRING diagram (page 6)
Fig. 9

Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. WARNING - Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

Set the electrical power supply within the space covered by the decorative flues. Position the power socket at a maximum distance of 33-7/16” (85 cm) from where the lead exits from the hood (see illustration alongside). Make sure this does not inter- fere with the bracket fastening area or with the decorative flue (where the flue touches the wall). Fit the plug into the power socket.

Page 7 of the Broan K3139 user manual — DUCT TAPE
Page 7 · cliquer pour agrandir
Page 7

CONNECT DUCTWORK

FLUE MOUNTING

BRACKET

Ducted Configuration Adjust the width of the flue mounting bracket to equal the inside width of decorative flue. Insert and tighten mounting screws to hold bracket width.

MOUNTING SCREWS

Use mounting screws and drywall anchors to secure flue mounting bracket to the ceiling as shown.

1. Use 6" round metal duct to connect the duct collar on the hood to the ductwork above. 2. Use duct tape to make all joints secure and air tight. 3. Insert the decorative flues setting them on the hood. 4. Extend the upper flue to the ceiling and secure with the mounting screws.

MOUNTING SCREWS

Broan K3139 — MOUNTING SCREWS diagram (page 7)
Fig. 10

FASTEN FLUE TO UPPER BRACKET

Broan K3139 — FASTEN FLUE TO UPPER BRACKET diagram (page 7)
Fig. 11

DECORATIVE

WITH MOUNTING SCREWS

FLUE

Broan K3139 — DECORATIVE diagram (page 7)
Fig. 12

DUCT TAPE

6" ROUND METAL DUCT

= · =

Page 8 of the Broan K3139 user manual — NON-DUCTED RECIRCULATION
Page 8 · cliquer pour agrandir
Page 8

Non-ducted recirculation Configuration 1. Adjust the width of the flue mounting bracket to equal the inside width of decorative flue. Insert and tighten mounting screws to hold bracket width. 2. Use mounting screws and drywall anchors to secure flue mounting bracket to the ceiling as shown. 3. Turn upper flue section upside down so air vents are at the top. Slide upper flue section into lower flue section. 4. Connect the non-ducted recirculation plenum to the upper flue section with (4) flat-head screws (supplied). 5. Install the reduction on the discharge collar. 6. Measure the distance from the top of the reduction to the ceiling. Cut a length of 5" round metal duct 5" shorter than this dimension. 7. Fit duct section over the non-ducted recirculation plenum. For best fit, make sure duct seam is toward the front. 8. Set duct/flue assembly on hood with top tilted away from wall. Reach around flue to engage bottom of duct with discharge collar on hood. Tilt flue up against wall. Duct seam can be cut to length if necessary. 9. Extend the upper flue to the ceiling and secure with the mounting screws.

MOUNTING SCREWS

MOUNTING SCREWS

UPPER FLUE SECTION

AIR VENTS (in upper flue section)

UPPER BRACKET

FASTEN FLUE TO UPPER BRACKET

Broan K3139 — UPPER BRACKET diagram (page 8)
Fig. 13

NON-DUCTED RECIRCULATION

WITH MOUNTING SCREWS

PLENUM

MEASURE

LOWER FLUE SECTION

DUCT SEAM

5" ROUND METAL DUCT

REDUCTION

DISCHARGE

COLLAR

= · =

Page 9 of the Broan K3139 user manual — GREASE FILTERS
Page 9 · cliquer pour agrandir
Page 9

NON-DUCTED RECIRCULATION FILTER INSTALLATION

Broan K3139 — NON-DUCTED RECIRCULATION FILTER INSTALLATION diagram (page 9)
Fig. 14
1. Position the filters over the blower. 2. Rotate to lock filters in place. 3. Purchase replacement filter packs (contains 2) from your dealer.

Part No. B03300487. CHARCOAL

FILTERS

MAINTENANCE

Broan K3139 — FILTERS diagram (page 9)
Fig. 15

Proper maintenance of the Range Hood will assure proper performance of the unit.

Grease Filters The grease filters should be cleaned fre- quently. Use a warm detergent solution. Grease filters are dishwasher safe. Remove filter by pushing filter towards the back of hood and rotating filter downward.

GREASE FILTERS

Charcoal Filters The charcoal filters should be changed every 6 months. Rotate the filters to remove and replace.

Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:

  • Hot water with soap or detergent is all that is usually needed.
  • Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.
  • For discolorations or deposits that persist, use a non-scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth.
  • For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.
  • DO NOT allow deposits to remain for long periods of time.
  • DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.
  • DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth. Painted surfaces should be cleaned with warm water and mild detergent only.
Page 10 of the Broan K3139 user manual — ELECTRICAL BOX SUPPORT FUSE
Page 10 · cliquer pour agrandir
Page 10

OPERATION

LIGHT SWITCH

BLOWER

MEDIUM

SPEED

The hood is operated using the (4) push- buttons located at eye-level, on the front edge of the hood.

BLOWER ON-LOW /

BLOWER

HIGH SPEED

PILOT

OFF SWITCH

LAMP

The light switch turns the halogen lamps on and off.

The blower on-low / off switch turns the blower on to its lowest running speed. The blower must be turned on using this switch. Turn the blower off by pressing this switch a second time.

The blower medium speed switch changes the blower speed to medium. This switch works only if the blower is already running at low or high speed.

The blower high speed switch changes the blower speed to high. This switch works only if the blower is already running at low or medium speed.

The pilot lamp lights up whenever the blower is on.

HALOGEN BULBS

This range hood requires two halogen bulbs (Type T4, 12V, 20W). ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

Broan K3139 — HALOGEN BULBS diagram (page 10)
Fig. 16

To change bulbs:

1. Loosen the ring nut by turning it counterclockwise. 2. Remove the bulb by pulling sideward (DO NOT ROTATE). CAUTION: BULB MAY BE HOT! 3. Replace with Type T4, 12V, 20W halogen bulb. Do not touch replacement bulb with bare hands!

RING NUT

FUSE REPLACEMENT

Broan K3139 — RING NUT diagram (page 10)
Fig. 17

SWITCH OFF THE ELECTRICITY SUPPLY.

Remove the grease filters.

Remove the electrical box support and open the fuse box.

Replace with the same type of fuse (5x20mm, 4A, 125V).

ELECTRICAL BOX SUPPORT FUSE

Controls

Page 11 of the Broan K3139 user manual — WARRANTY
Page 11 · cliquer pour agrandir
Page 11

WARRANTY

BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WAR- RANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PAR- TICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENDT BULBS. This warranty does not cover (a) normal mainte- nance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan), faulty installation or installation contrary to recommended installa- tion instructions. The duration of any implied warranty is limited to the one- year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CON- NECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. BEST BY BROAN, P.O. Box 140 Hartford, Wisconsin 53027

Poser une question sur : Broan K3139

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan K3139

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan K3139 manuel PDF

36 pages·410 KB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…