FR
Broan logo
Notice d'utilisation officielle

Broan E66136SS

48 pages·5.1 MB·Cuisinière·PDF·ENDEITNLJA
Broan E66136SS
Table des matières 80 sections INSTALLATION INSTRUCTIONS · REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register · SV08340 rev. C · WARNING WARNING ! ! · … AfficherMasquer
INSTALLATION INSTRUCTIONSp.1REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/registerp.1SV08340 rev. Cp.1WARNING WARNING ! !p.2- E60000 SERIES RANGE HOOD SYSTEM -p.3INTERNAL BLOWERSp.3M ODEL 634 OR 644p.3(R OOF C AP )p.3IN-LINE AND EXTERIOR BLOWERSp.4M ODEL HLB9 (800 CFM )p.4O PTIONAL )p.4HL0100p.41. SELECT BLOWER OPTION AND INSTALLATION TYPEp.5MODEL 331H, 332H, 335 OR 336 EXTERIOR BLOWER TYPICAL DUCTWORKp.5MODEL HLB3, HLB6, HLB9 OR HLB11 IN-LINE BLOWER TYPICAL DUCTWORKp.52. MEASURE INSTALLATIONp.6HH0093Ap.6MINIMUM AND MAXIMUM DISTANCEp.6OVER COOKTOPp.63. PREPARE THE INSTALLATIONp.63. PREPARE THE INSTALLATION (CONT’D)p.7D UCTED INSTALLATIONS ONLYp.74. INSTALL BACKSPLASH (OPTIONAL)p.7(Optional) RMP Seriesp.75. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY)p.8V ERTICAL DISCHARGEp.8H ORIZONTAL DISCHARGEp.86. REMOVE FILTERS AND THE GREASE DRIP RAILp.87. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)p.88. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) HOOD ONLY)p.9L EFT S IDE M OUNTINGp.9S CREW L OCATIONp.9R IGHT S IDE M OUNTING S CREWp.9L OCATIONp.9HD0282p.9HD0269p.9HD0270p.9L OCATION L EFT S IDE M OUNTINGp.9HD0288 HD0289p.99. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)p.10(INTERNAL BLOWER(S) HOOD ONLY)p.1010. INSTALL WOOD MOUNTING STRIPp.1011. INSTALL ANKE60 RECIRCULATION KIT (NON-DUCTED INSTALLATION ONLY)p.1012. INSTALL AEE OPTIONAL SOFFIT CHIMNEYp.10(DUCTED INSTALLATION ONLY)p.1013. INSTALL THE HOODp.11M OUNTING SCREWS LOCATIONp.11HD0264p.11W ALL ANCHORS LOCATIONp.1114. ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)p.11R OUGH - IN PLATEp.11ON TOP OF HOODp.11L OCKNUTSp.11W IRINGp.11COVERp.11P LATE ON BACK OF HOODp.1115. CONNECT THE WIRING (ALL BLOWERS)p.1116. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER)p.12A Bp.1217. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERSp.1218. INSTALL LIGHT BULBSp.1219. USE AND CAREp.13Avoid: When choosing a detergentp.1320. OPERATIONp.13HEAT SENTRY ™p.1320. OPERATION (CONT’D)p.1421. WARRANTYp.14WARRANTYp.1422. WIRING DIAGRAMSp.15Broan Elite E60000 Series Internal blower(s) hoodsp.15NEONp.15Broan Elite E60000 Series Exterior or In-Line blower hoodsp.1523. SERVICE PARTSp.16Broan Elite E60000 Series Internal blower hoodsp.16HL0106p.16HL0105p.16K EYp.16P ARTp.161 SV13296p.16SV17797p.16
Page 1 of the Broan E66136SS user manual — Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
Page 1 · cliquer pour agrandir
Page 1

INSTALLATION INSTRUCTIONS

Broan E66136SS — INSTALLATION INSTRUCTIONS diagram (page 1)
Fig. 1

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGE 13 AND 14.

Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119

REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register

SV08340 rev. C

Page 2 of the Broan E66136SS user manual — WARNING WARNING ! !
Page 2 · cliquer pour agrandir
Page 2

WARNING WARNING ! !

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN—You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels—This could cause a violent steam explosion. 4. Use an extinguisher ONLY if: A. You own a Class ABC extinguisher and you
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

know how to operate it. B. The fire is small and contained in the area

where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA. CAUTION

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

1. For indoor use only. 2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it will be cooled down. If the motor continues to shut off and restart, have the hood serviced. 5. For best capture of cooking impurities, the bottom of the hood should be at a minimum of 24” and at a maximum of 30” above the cooking surface. 6. Two installers are recommended because of the large size and weight of this hood. 7. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside—Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage. 8. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 9. Because of the high exhausting capacity of this hood, you should make sure enough air is entering the house to replace exhausted air. Use an appropriate make-up air device or open a window close to or in the kitchen. 10. To reduce the risk of fire and electric shock, the Broan Elite E60E Series hood must be installed with one Broan exterior blower model 331H, 332H, 335 or 336; or one Broan in-line blower model HLB3, HLB6, HLB9, HLB11. Other blowers cannot be substituted. (Exterior or in-line blowers sold separately.) 11. Please read specification label on product for further information and requirements.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any additional solid-state speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

Page 3 of the Broan E66136SS user manual — (R OOF C AP )
Page 3 · cliquer pour agrandir
Page 3

- E60000 SERIES RANGE HOOD SYSTEM -

INTERNAL BLOWERS

MODEL 437 (HIGH CAPACITY ROOF CAP)

MODEL 441 (10’’ ROUND WALL CAP)

MODEL 647 (7” ROUND WALL CAP)

M ODEL 634 OR 644

MODEL 643 (8” ROUND WALL CAP)

(R OOF C AP )

Broan E66136SS — (R OOF C AP ) diagram (page 3)
Fig. 2

MODEL 418 (10” ROUND ADJUSTABLE ELBOW)

MODEL 410 (10” ROUND DUCT —2 FT. SECTIONS)

TO 10” ROUND, 6” HIGH - LATERAL

TO 10” ROUND - HORIZ. FRONT/REAR

ADAPTER/DAMPER 3¼’’ X 10’’ (SUPPLIED WITH SINGLE BLOWER HOOD)

42” AND 48” ONLY SINGLE BLOWER (600 CFM)

Page 4 of the Broan E66136SS user manual — O PTIONAL )
Page 4 · cliquer pour agrandir
Page 4

- E60000 SERIES RANGE HOOD SYSTEM -

IN-LINE AND EXTERIOR BLOWERS

MODEL 437 (HIGH CAPACITY ROOF CAP)

MODEL 441 (10” ROUND WALL CAP)

M ODEL HLB9 (800 CFM )

Broan E66136SS — M ODEL HLB9 (800 CFM ) diagram (page 4)
Fig. 3

IN-LINE BLOWER (INCLUDES TWO 8” X 12” TO

MODEL 441 (10” ROUND WALL CAP)

IN-LINE BLOWER (INCLUDES TWO 4½” X 18½” TO

MODEL 421 (10” ROUND VERT. IN-LINE DAMPER) RECOMMENDED FOR USE WITH EXTERIOR BLOWERS

IN-LINE BLOWER (INCLUDES ONE 8” TO 10”

MODEL 410 (10” ROUND DUCT - 2FT. SECTIONS)

332KR IN-LINE AND EXTERIOR BLOWER ROUGH-IN KIT (SUPPLIED WITH HOOD)

RMP SERIES BACKSPLASH (STAINLESS STEEL WALL COVERING

WITH WARMING SHELVES.

O PTIONAL )

HL0100

Page 5 of the Broan E66136SS user manual — MODEL 331H, 332H, 335 OR 336 EXTERIOR BLOWER TYPICAL DUCTWORK
Page 5 · cliquer pour agrandir
Page 5

1. SELECT BLOWER OPTION AND INSTALLATION TYPE

1.1 NON-DUCTED INSTALLATION For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series.

1.2 DUCTED INSTALLATION The Broan Elite E60000 Series range hood includes many configurations: hoods with single or double internal blowers (included with the hood), or hoods using external blowers. For this last category, the Broan Elite E60000 Series must be installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only. Other blowers cannot be substituted. (Blowers sold separately). Plan where and how the ductwork will be installed. If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 6, 10, 12 and up of this manual. Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10” round ducts, use a transition (internal blowers only). Use 2” duct tape to seal duct joints.

Broan E66136SS — 1. SELECT BLOWER OPTION AND INSTALLATION TYPE diagram (page 5)
Fig. 4
Broan E66136SS — 1. SELECT BLOWER OPTION AND INSTALLATION TYPE diagram (page 5)
Fig. 5

7” or 8” ROUND OR 3¼” x 10” DUCT

7” or 8” ROUND OR 3¼” x 10” RECTANGULAR

MODEL 331H, 332H, 335 OR 336 EXTERIOR BLOWER TYPICAL DUCTWORK

MODEL HLB3, HLB6, HLB9 OR HLB11 IN-LINE BLOWER TYPICAL DUCTWORK

Page 6 of the Broan E66136SS user manual — HH0093A
Page 6 · cliquer pour agrandir
Page 6

2. MEASURE INSTALLATION

Dimensions for the most common installation are illustrated beside.

Ceiling Cabinet, soffit, decorative flue or

The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion.

Top of wood mounting strip A + 2’’

A

the hood and cooktop:

Recommended maximum distance between the hood

and cooktop30’’

Standard 36” high cooktop

HH0093A

MINIMUM AND MAXIMUM DISTANCE

OVER COOKTOP

3. PREPARE THE INSTALLATION

Remove the installation kit from inside the hood. Make sure that the following items are included: -Wood strip (attached to back of hood) -Installation manual -Accessories including:

  • Baffle filters: 30” and 36” hoods come with 3 baffle filters; 42” and 48” hoods come with 4 baffle filters
  • Baffle filters handles (taped inside the hood)
  • 3¼” x 10” adapter/damper (included with internal single blower hood)
  • 4½” x 18½” adapter (included with internal double blower hood)
  • In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
  • Bag of parts including: (4) flat head screws no. 10-2’’, (8) screws no. 8 x 3/4’’, (2) wire connectors, (3) wall anchors, (3) washers 13/64’’ ID x 3/4’’ OD, (1) wire clamp, (8) mechanical screws no. 8-32 x 1/4”, (4) no. 8 x 3/8” screws Parts sold separately: - In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition) - Exterior blower assembly 331H, 332H, 335 or 336 - Shielded GU10 50W halogen bulbs (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width) - RMP Series Backsplash (optional) - ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only) - AEE Series Decorative flue, to be installed over the hood (optional) - Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers.
Show 4 more labels / short text on this page
non-duct kit flue · Hood · Minimum distance between · 24’’
Page 7 of the Broan E66136SS user manual — (Optional) RMP Series
Page 7 · cliquer pour agrandir
Page 7

3. PREPARE THE INSTALLATION (CONT’D)

D UCTED INSTALLATIONS ONLY

Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (vertical or horizontal).

Broan E66136SS — D UCTED INSTALLATIONS ONLY diagram (page 7)
Fig. 6
HOOD WIDTHSDIMENSION C 30’’13” 36’’16” 42’’19” 48’’22”
HOOD WIDTHSDIMENSION C 30’’13” 36’’16” 42’’19” 48’’22”
A C ³8” 578”3½” B L 478 Ø 10½” 478 ½”

4. INSTALL BACKSPLASH (OPTIONAL)

(Optional) RMP Series

Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel or cooktop. (See instructions packed with backsplash.)

Page 8 of the Broan E66136SS user manual — 7. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)
Page 8 · cliquer pour agrandir
Page 8

5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY)

Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.

Broan E66136SS — 5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY) diagram (page 8)
Fig. 7

V ERTICAL DISCHARGE

H ORIZONTAL DISCHARGE

Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag). NOTE: For a non-ducted installation, punch

out the back electrical knock-out (B).

6. REMOVE FILTERS AND THE GREASE DRIP RAIL

Broan E66136SS — 6. REMOVE FILTERS AND THE GREASE DRIP RAIL diagram (page 8)
Fig. 8

Remove filters from hood and set aside. NOTE: It is recommended to start with the center one.

B. Remove tape on grease drip rail (1).

7. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)

Broan E66136SS — 7. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY) diagram (page 8)
Fig. 9

Remove the adapter (1), or adapter/damper, taped inside the hood.

Page 9 of the Broan E66136SS user manual — S CREW L OCATION
Page 9 · cliquer pour agrandir
Page 9

8. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) HOOD ONLY)

All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel of the hood. The procedure below applies for one or two blowers.

Broan E66136SS — 8. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) HOOD ONLY) diagram (page 9)
Fig. 10
Broan E66136SS — 8. HORIZONTAL DISCHARGE INSTALLATION ( INTERNAL BLOWER(S) HOOD ONLY) diagram (page 9)
Fig. 11

L EFT S IDE M OUNTING

S CREW L OCATION

Using a 5/16” socket, remove all blower mounting screws from the inner top of the hood. Keep the screws for further use.

R IGHT S IDE M OUNTING S CREW

L OCATION

HD0282

HD0269

Slide the blower to disengage its flange from the retaining bracket.

HD0270

Broan E66136SS — HD0270 diagram (page 9)
Fig. 12
Broan E66136SS — HD0270 diagram (page 9)
Fig. 13

R IGHT S IDE M OUNTING S CREW

L OCATION L EFT S IDE M OUNTING

Rotate the blower and engage its flange in the back wall retaining bracket. Using a 5/16” socket and the screws previously removed, secure the blower to the hood.

S CREW L OCATION

HD0288 HD0289

Page 10 of the Broan E66136SS user manual — 12. INSTALL AEE OPTIONAL SOFFIT CHIMNEY
Page 10 · cliquer pour agrandir
Page 10

9. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)

(INTERNAL BLOWER(S) HOOD ONLY)

Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10” adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install an appropriate sized transition and seal the joints with duct tape.

Broan E66136SS — 9. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE) diagram (page 10)
Fig. 14

10. INSTALL WOOD MOUNTING STRIP

Broan E66136SS — 10. INSTALL WOOD MOUNTING STRIP diagram (page 10)
Fig. 15

Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustration beside and under step 2). Remove wood mounting strip from back of hood. Use no. 10 - 2’’ flat head screws to secure the mounting strip to the drywall. Make sure to hit the wall studs.

Due to the weight of this hood, ensure that the wood strip is attached to all of the available studs (2 studs minimum for a 30’’ width hood, more as hood width increases); not into the drywall alone.

1. Drywall 2. Wood mounting strip 3. Flat head screw
4. Wall anchor location 5. Back of hood outline 6. Wall studs

11. INSTALL ANKE60 RECIRCULATION KIT (NON-DUCTED INSTALLATION ONLY)

Refer to the instructions sheet included with the recirculation kit for details.

12. INSTALL AEE OPTIONAL SOFFIT CHIMNEY

(DUCTED INSTALLATION ONLY)

Refer to the instructions sheet included with the optional soffit chimney.

Page 11 of the Broan E66136SS user manual — R OUGH - IN PLATE
Page 11 · cliquer pour agrandir
Page 11

13. INSTALL THE HOOD

INTERNAL BLOWER(S) ONLY Run power cable to installation location. Remove the electrical compartment cover. Insert the cable in the hood and tighten the wire clamp to secure the cable. ALL INSTALLATIONS Rest the back cavity of the hood on the wood mounting strip. Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4’’ (for 30’’ and 36’’ width hoods) or (6) screws (for 42’’ and 48’’ width hoods) provided at locations shown. Drill (3) 3/16’’ size holes into the drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the three wall anchors with the remaining no. 8 x 3/4’’ screws and the (3) washers provided.

M OUNTING SCREWS LOCATION

HD0264

W ALL ANCHORS LOCATION

For a non-ducted installation, go to step 15, Connect the wiring.

14. ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)

Run power cable to installation location. For ducting through top of hood, existing plate remains in place on inside back of hood. For ducting through back of hood, remove existing plate from inside back of hood and remove the rough-in plate from the top of hood. Attach the plate to inside top of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the rough-in plate to the back of hood so that the wiring box is located on the right side as you are facing the hood. Connect ducting to rough-in plate as you are installing the rough-in plate. Use duct tape to make all joints secure and air-tight. HD0262

R OUGH - IN PLATE

ON TOP OF HOOD

L OCKNUTS

W IRING

COVER

L OCKNUTS

P LATE ON BACK OF HOOD

15. CONNECT THE WIRING (ALL BLOWERS)

Broan E66136SS — R OUGH - IN PLATE diagram (page 11)
Fig. 16

Remove wiring cover from rough-in plate or electrical compartment and set aside.

INTERNAL BLOWERS: Connect cable into wiring box using wire connectors. Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.

Broan E66136SS — R OUGH - IN PLATE diagram (page 11)
Fig. 17
Broan E66136SS — R OUGH - IN PLATE diagram (page 11)
Fig. 18

Reinstall wiring cover.

IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.

Page 12 of the Broan E66136SS user manual — 18. INSTALL LIGHT BULBS
Page 12 · cliquer pour agrandir
Page 12

16. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER)

Refer to instructions included with blower. Plug the 3-prong plug cord from rough-in plate to the 3-prong male connector inside the hood (A) and the 2-prong male connector cord from rough-in plate to the 2-prong plug inside the hood (B).

Broan E66136SS — 16. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER) diagram (page 12)
Fig. 19

A B

HE0078 WARNING Do not plug the 2 cords together.

!

17. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS

Broan E66136SS — ! diagram (page 12)
Fig. 20

Reinstall grease drip rail. The illustration beside shows how to reinsert the grease drip rail into the range hood.

Remove protective plastic film covering filters before installing them.

to the filters, using provided no. 8-32 x 1/4” screws, before installing them in the hood. It is recommended to install side filters first and finish with center one(s).

1. Insert one end of the filter into the upper channel of the hood. 2. Raise the other end toward the inside of hood and insert in the grease drip rail of the hood.

18. INSTALL LIGHT BULBS

Broan E66136SS — 18. INSTALL LIGHT BULBS diagram (page 12)
Fig. 21

This hood must use 50W, 120V with GU10 base, shielded halogen bulbs (not included). (2 required for 30” and 36” hood width or 3 for 42” and 48” hood width.)

1. Install bulbs by placing the bulb leads into their grooves in the socket. 2. Gently push upwards and turn clockwise until secure.

To remove bulbs, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves. NOTE: If need be, use a rubber dishwashing glove to add grip when removing the bulb.

Page 13 of the Broan E66136SS user manual — !
Page 13 · cliquer pour agrandir
Page 13

19. USE AND CARE

Baffle Filters The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by the warranty.

Grease Drip Rail The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail to dry completely before reinstalling it in the hood. Blower Cleaning (Internal) Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water. Hood Cleaning Stainless steel cleaning:

  • Do:
  • Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
  • Always clean in the direction of original polish lines.
  • Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely.
  • You may also use a specialized household stainless steel cleaner.
  • Don’t:
  • Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
  • Use any harsh or abrasive cleansers.
  • Allow dirt to accumulate.
  • Let plaster dust or any other construction residues reach the hood. During construction/renovation, cover the hood to make sure no dust sticks to stainless steel surface.

Avoid: When choosing a detergent

  • Any cleaners that contain bleach will attack stainless steel.
  • Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
  • Any combustible products used for cleaning such as acetone, alcohol, ether, benzol , etc., are highly explosive and should never be used close to a range.

20. OPERATION

Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.

HEAT SENTRY ™

This hood is equipped with a Heat Sentry™thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1. If blower is OFF - it turns blower ON to HIGH speed.
2. If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.

!

When the temperature level drops to normal, the blower will return to its original setting.

Page 14 of the Broan E66136SS user manual — 21. WARRANTY
Page 14 · cliquer pour agrandir
Page 14

20. OPERATION (CONT’D)

Broan E66136SS — 20. OPERATION (CONT’D) diagram (page 14)
Fig. 22

A) Halogen light knob B) Blower speed control knob

1. Halogen light knob 2) Blower operation indicator 3) ON/OFF blower switch 4) Blower speed control knob

COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower operates at the previous setting of the speed control (4). Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.

21. WARRANTY

WARRANTY

ONE YEAR LIMITED WARRANTY FOR BROAN ELITE PRODUCTS Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Broan Elite products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to another. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at one of the addresses or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. In USA - Broan-NuTone LLC; 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711 In Canada - Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119

Page 15 of the Broan E66136SS user manual — Broan Elite E60000 Series Exterior or In-Line blower hoods
Page 15 · cliquer pour agrandir
Page 15

22. WIRING DIAGRAMS

Broan Elite E60000 Series Internal blower(s) hoods

NEON

Broan E66136SS — Broan Elite E60000 Series Internal blower(s) hoods diagram (page 15)
Fig. 23 · Broan Elite E60000 Series Internal blower(s) hoods

BLK BLACK BLU BLUE BRN BROWN ORA ORANGE RED RED WHT WHITE YEL YELLOW

Broan Elite E60000 Series Exterior or In-Line blower hoods

NEON

Broan E66136SS — Broan Elite E60000 Series Exterior or In-Line blower hoods diagram (page 15)
Fig. 24 · Broan Elite E60000 Series Exterior or In-Line blower…
Page 16 of the Broan E66136SS user manual — * SV08352
Page 16 · cliquer pour agrandir
Page 16

23. SERVICE PARTS

Broan Elite E60000 Series Internal blower hoods

Broan Elite E60000 Series Exterior or In-Line blower hoods

HL0106

HL0105

K EY

P ART

NO. DESCRIPTION QTY. (HOOD WIDTH) 30” 36” 42” 48”

K EY

NO. PART NO. DESCRIPTION QTY. (HOOD WIDTH) 30” 36” 42” 48” 2 SV06750 BROAN ELITE LOGO 1 3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y 2 2 3 3 4 SV03435 HEAT SENTRY™ THERMOSTAT 1 5 SV08338 LIGHT SWITCH 1 6 SV03501 SPEED CONTROL 1 7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS) 1

NO.

ADAPTER/DAMPER 3¼” X 10” (1-BLOWER HOOD) ADAPTER 4¼” x 18½” (2-BLOWER HOOD)

1 SV13296

1 2 SV06750 BROAN ELITE LOGO 1 3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y 2 2 3 3 4 SV03435 HEAT SENTRY™ THERMOSTAT 1 5 SV08338 LIGHT SWITCH 1 6 SV03501 SPEED CONTROL 1 7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS) 1 8 SV08343 REPLACEMENT CHARCOAL FILTERS (PAIR) 1 9 SV08344 CHARCOAL FILTER SUPPORTS (PAIR) 1

SV17797

- - - 1 12 SV08337 FILTER SPRING (SET OF 6) 1

SV17640 SV17641 SV17642 SV17643

GREASE RAIL 30” GREASE RAIL 36” GREASE RAIL 42” GREASE RAIL 48”

1. - -

- 1 - -

- - 1 -

10 SV08097 INTERNAL MOTOR (1 OR 2, DEPENDING ON HOOD MODEL) 1

13 SV17606 SV17609

2 1 - 3 2 2 - 4 14 SV08339 BLOWER ROCKER SWITCH 15 SV08093 PILOT LAMP ASS’Y 16 SV08354 ROUGH-IN PLATE 10” ROUND 17 SV13924 FEMALE CONNECTOR 18 SV13923 MALE CONNECTOR 19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3 3 4 4

BAFFLE FILTER 8.84” X 15.25” BAFFLE FILTER 11.84” X 15.25”

- - - 1 12 SV08337 FILTER SPRING (SET OF 6) 1

SV17640 SV17641 SV17642 SV17643

GREASE RAIL 30” GREASE RAIL 36” GREASE RAIL 42” GREASE RAIL 48”

1. - -

- 1 - -

- - 1 -

13 SV17606 SV17609

2 1 - 3 2 2 - 4 14 SV08339 BLOWER ROCKER SWITCH 15 SV08093 PILOT LAMP ASS’Y 19 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3 3 4 4

BAFFLE FILTER 8.84” X 15.25” BAFFLE FILTER 11.84” X 15.25”

* SV08340 INSTALLATION GUIDE 1

PARTS BAG ([2] WIRE CONNECTORS, [1] WIRE CLAMP, [3] WALL ANCHORS [3] WASHERS 13/64” ID X 3/4”, [4] SCREWS NO. 8 X 3/8”, [8] SCREWS NO. 8 X 3/4”, [8] MECHANICAL SCREWS NO. 8-32 X 1/4”, [4] FLAT HEAD SCREWS NO. 10-2”

* SV08340 INSTALLATION GUIDE 1

* SV08352

1

PARTS BAG: ([2] WIRE CONNECTORS, [1] WIRE CLAMP, [3] WALL ANCHORS [3] WASHERS 13/64” ID X 3/4” OD, [4] SCREWS NO. 8 X 3/8”, [8] SCREWS NO. 8 X 3/4”, [8] MECHANICAL SCREWS NO. 8-32 X 1/4”, [4] FLAT HEAD SCREWS NO. 10-2”

* SV08352

1

* NOT SHOWN.

* NOT SHOWN.

Page 17 of the Broan E66136SS user manual — Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119
Page 17 · cliquer pour agrandir
Page 17

GUIDE D’INSTALLATION

Broan E66136SS — GUIDE D’INSTALLATION diagram (page 17)
Fig. 25
INSTALLATEURLAISSER CE MANUEL AU PROPRIÉTAIRE. PROPRIÉTAIRE : INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN

EN PAGES 29 et 30.

Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119

ENREGISTREZ VOTRE PRODUIT EN LIGNE À : www.broan.com/register

SV08340 rév. C

Poser une question sur : Broan E66136SS

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan E66136SS

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan E66136SS manuel PDF

48 pages·5.1 MB·Cuisinière·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…