FR
Broan logo
Notice d'utilisation officielle

Broan E54000

44 pages·1.4 MB·Téléviseur à écran plat·PDF·ENDEITNLJA
Broan E54000
Table des matières 80 sections Model E54000 · 99043938E · READ AND SAVE THESE INSTRUCTIONS · ! INTENDED FOR DOMESTIC COOKING ONLY ! · … AfficherMasquer
Page 1 of the Broan E54000 user manual — 99043938E
Page 1 · cliquer pour agrandir
Page 1
Broan E54000 — Model E54000 diagram (page 1)
Fig. 1 · Model E54000

Model E54000

ENGLISH 2 FRANÇAIS 15 ESPAÑOL 28

In USA - BROAN Hartford, Wisconsin In CANADA - BROAN Drummondville, QC, Canada

REGISTER YOUR PRODUCT ONLINE ATwww.Broan.com/register

For additional Information visit www.Broan.com

99043938E

Page 2 of the Broan E54000 user manual — WARNING
Page 2 · cliquer pour agrandir
Page 2

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accor- dance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip- ment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this unit with any separate solid-state speed control device. 8. To reduce the risk of fire, use only metal ductwork. 9. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high settings. Boilovers cause smoking and

greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or when cooking flaming foods. (i.e.

Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or

filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface

element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you already know how to operate

it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA.

Page 3 of the Broan E54000 user manual — READ AND SAVE THESE INSTRUCTIONS
Page 3 · cliquer pour agrandir
Page 3

! CAUTION 1. For indoor use only. 2. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 3. Take care when using cleaning agents or detergents. 4. Avoid using food products that produce flames under the Range Hood. 5. For general ventilating use only. Do not use to exhaust hazardous or explosive materi- als and vapors. 6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 7. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. 8. For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. See “Prepare Support Frame” section for mounting restrictions. 9. Two installers are recommended because of the large size and weight of this hood. 10. This product is equipped with a thermostat which may start blower automatically. To reduce the risk of injury and to prevent power from being switched on accidentally, switch power off at service panel and lock or tag service panel. 11. Use with approved cord-connection kit only. 12. Please read specification label on product for further information and requirements.

Page 4 of the Broan E54000 user manual — RING NUT !
Page 4 · cliquer pour agrandir
Page 4

OPERATION

LIGHT SWITCH

BLOWER

Controls The hood is operated using the slide controls under the bottom of the hood.

SWITCH

PILOT

LAMP

The light switch turns the lamps on and off.

The blower switch turn the blower on to three speed settings:

0. OFF 1 - LOW SPEED 2 - MEDIUM SPEED 3 - HIGH SPEED

The pilot lamp lights up whenever the blower is on.

HEAT SENTRY™ Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface. 1) If blower is OFF - it turns blower ON to HIGH speed. 2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

HALOGEN BULBS

This range hood requires (4) halogen bulbs (Type T3, 12Volt, 20 Watt Max, G-4 Base). WARNING: Always switch off the electricity supply before carrying out any operations on the appliance.

Broan E54000 — HALOGEN BULBS diagram (page 4)
Fig. 2

To change bulbs:

1. Loosen the ring nut by turning it counterclockwise. 2. Remove the bulb by pulling sideward(DO NOT ROTATE). CAUTION: Bulb may be hot! 3. Replace with Type T3, 12Volt, 20 Watt Max, G-4 Base halogen bulb. Do not touch replacement bulb with bare hands!

RING NUT !

Do not use bulbs greater then 20 Watts. Bulbs greater than 20 Watts will cause fuse to open.

Page 5 of the Broan E54000 user manual — FUSE
Page 5 · cliquer pour agrandir
Page 5

FUSE REPLACEMENT

Broan E54000 — FUSE REPLACEMENT diagram (page 5)
Fig. 3

IF LIGHTS FAIL TO OPERATE, DISCONNECT THE POWER AT THE SERVICE ENTRANCE. CHECK THE FUSE AND REPLACE IF NECESSARY.

1. Remove the grease filters.
2. Remove the cover of the fuse box.
3. Locate the fuse holder. Unscrew its cap and remove the fuse.

FUSE BOX

4. Replace the fuse with the same size and amperage (5x20mm, 4amp, 125volt).

Do not use fuses greater than 4 amps. Fuses greater than 4 amps may damage the transformer.

FUSE

5. Reinstall the fuse holder cap, fuse box cover and grease filters.
6. Reconnect power at the service entrance.
Page 6 of the Broan E54000 user manual — MAINTENANCE
Page 6 · cliquer pour agrandir
Page 6

MAINTENANCE

Proper maintenance of the Range Hood will assure proper performance of the unit.

Grease Filter The grease filter should be cleaned frequently. Use a warm detergent solution. Grease filter is dishwasher safe. See “INSTALL FILTERS” section for removal and installation instructions.

Non-ducted Recirculation Filter The non-ducted recirculation filter should be changed every 6 months. See “INSTALL FILTERS” sectionfor removal and installation instructions.

Hood Cleaning Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:

O Hot water with soap or detergent is all that is usually needed.

O Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to

avoid water marks.

O For discolorations or deposits that persist, use a non-scratching household

cleanser or stainless steel polishing powder with a little water and a soft cloth.

O For stubborn cases, use a plastic scouring pad or soft bristle brush together with

cleanser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.

O DO NOT allow deposits to remain for long periods of time.

O DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere

to the surface causing rust.

O DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to

remain in contact with stainless steel for extended periods. Many of these com- pounds contain chemicals which may be harmful. Rinse with water after expo- sure and wipe dry with a clean cloth. Painted surfaces should be cleaned with warm water and mild detergent only.

Page 7 of the Broan E54000 user manual — DECORATIVE FLUE SUPPORT FRAME
Page 7 · cliquer pour agrandir
Page 7

PREPARE THE HOOD

Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Support Frame 1 - Parts Bag containing: 1 - Support Frame Bracket 1 - Discharge Collar 4 - Lag Bolts (6 x 70mm) 14 - Mounting Screws (3.9 x 9.5mm Pan Head) 2 - Mounting Screws (2.9 x 9.5mm Pan Head) 4 - Washers 6.4mm Diameter 6 - Serrated Washers 1 - Wiring Box Cover 1 - Wire Clamp 1 - Installation Instructions

DISCHARGE COLLAR

SUPPORT FRAME BRACKET

WIRE CLAMP

Broan E54000 — DISCHARGE COLLAR diagram (page 7)
Fig. 4
Broan E54000 — DISCHARGE COLLAR diagram (page 7)
Fig. 5

WIRING BOX COVER

4 LAG BOLTS (6 x 70mm)

DECORATIVE FLUE SUPPORT FRAME

14 MOUNTING SCREWS (3.9 x 9.5mm Pan Head)

4 WASHERS 6.4mm 6 SERRATED WASHERS

2 MOUNTING SCREWS (2.9 x 9.5mm Pan Head)

Page 8 of the Broan E54000 user manual — FRONT
Page 8 · cliquer pour agrandir
Page 8

INSTALL THE DUCTWORK

Broan E54000 — INSTALL THE DUCTWORK diagram (page 8)
Fig. 6

ROOF CAP

DUCTED HOODS ONLY

6” ROUND

DUCT

! CAUTION: To reduce the risk of fire, use only metal ductwork.

1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs. 4. Install a roof or wall cap. Connect round metal ductwork to cap and work back to- wards hood location. Use duct tape to seal the joints between ductwork sec- tions.

ROUND ELBOW

DECORA-

EAVE VENT

TIVE FLUE

HOOD

24” to 30” ABOVE COOKING SURFACE (See “Prepare Support

Frame” section for mounting restriction)

DRYWALL

CROSS FRAMING

INSTALL SUPPORT SYSTEM

Broan E54000 — DRYWALL diagram (page 8)
Fig. 7

81/16”

1. At hood location, install 2 X 4 cross framing between ceiling joists using dimensions shown. 2. Finish the ceiling surface. Be sure to mark the location of the ceiling joists and cross framing. 3. Secure the support frame bracket to joists and cross framing with four lag bolts provided (6x70mm) and four washers (6.4mm). Make sure screws are driven into center of joists and framing for maximum strength. Be careful, because the position of the bracket determines the final position of the hood: the side with the slot B corresponds to the controls side. Fig. 2.

CEILING

JOISTS

WASHERS

(Ø6.4mm)

FRONT

SLOT B

LAG BOLTS

TOP VIEW OF SUPPORT FRAME

81/16”

Broan E54000 — FRONT diagram (page 8)
Fig. 8

515/16”

315/16”

3”

Page 9 of the Broan E54000 user manual — 10-FOOT CEILINGS
Page 9 · cliquer pour agrandir
Page 9

PREPARE SUPPORT FRAME

Broan E54000 — PREPARE SUPPORT FRAME diagram (page 9)
Fig. 9

8 AND 9-FOOT CEILINGS

HEIGHT ADJUSTMENT SLOTS

1. Measure the ceiling height and determine distance between the cook top and bottom of hood.
2. Remove (4) screws and washers in the height adjustment slots. Figure 8.
3. Per the chart, adjust overall lenght of the support frame. Figure 8.
4. Reinstall (4) screws and washers in the height adjustment slots. Figure 8.

FRONT

CEILING HEIGHTDUCT METHODHOOD DISTANCE ABOVE 36” HIGH COOK TOP (See note a) 24” 25” 26” 27” 28” 29” 30” LENGHT OF SUPPORT FRAME, DIMENSION “A” 8 FOOT CEILINGDUCTED22”21” NON DUCTED22”21” 9 FOOT CEILINGDUCTED & NON DUCTED32”31”30”29”28” 10 FOOT CEILING (see note b)DUCTED & NON DUCTED46”45”44”43”42”41”40”

A maximun of 30” above cook top is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer’s and user’s discretion; providing that ceiling height and flue length permit. b. Requires optional 10-foot flue extension.

10-FOOT CEILINGS

  • Flue extension model FX54SS for ducted installations
  • Flue extension model FXN54SS for non-ducted installations
5. Discard the upper support frame half supplied with the range hood. Replace with the longer upper support frame supplied with the flue extension.
6. Follow steps 1 through 4 shown above.
Page 10 of the Broan E54000 user manual — 6”/5” ADAPTER
Page 10 · cliquer pour agrandir
Page 10

PREPARE SUPPORT FRAME, cont’d.

MOUNTING SCREWS

Broan E54000 — MOUNTING SCREWS diagram (page 10)
Fig. 10
7. Hang the support frame from the support frame bracket (located on ceiling). Securely fasten with (4) 3.9x9.5mm mounting screws. Fig. 9.

SUPPORT FRAME BRACKET

SUPPORT

FRAME

FRONT

MOUNTING

ELECTRICAL MOUNTING PLATE

SCREWS (3.9x9.5mm)

PREPARE THE HOOD

Broan E54000 — PREPARE THE HOOD diagram (page 10)
Fig. 11

DUCTED AND NON-DUCTED HOODS

1. Assemble the Electrical Mounting Plate to the hood with (2) 3.9x9.5mm mounting screws and (2) serrated washers. Fig. 10.

DUCTED HOODS ONLY

2. Install the plastic discharge collar into the opening of the blower discharge. Fig. 11.
3. Install 6” diameter metal duct over the blower discharge. It must be long enough to reach ducting that discharges to the outside. Duct tape all joints to make them secure and air tight.

DISCHARGE COLLAR DUCTED ONLY

Broan E54000 — DISCHARGE COLLAR DUCTED ONLY diagram (page 10)
Fig. 12

NON-DUCTED HOODS ONLY

NON-DUCTED ONLY

1. Discard the plastic discharge collar supplied with the hood. Install the 5” to 6” adapter (supplied with the non-ducted recirculation kit) over the blower discharge. Fig. 12.

6”/5” ADAPTER

Broan E54000 — 6”/5” ADAPTER diagram (page 10)
Fig. 13
2. Duct tape alljoints to make them secure and air tight.
Page 11 of the Broan E54000 user manual — VENTS “DOWN”
Page 11 · cliquer pour agrandir
Page 11

PREPARE THE HOOD, cont’d.

NON-DUCTED HOODS ONLY 3. Install the non-ducted recirculation plenum through the upper rectangular openings in the support frame. Fig. 13 4. Install the 5” diameter duct connector to plenum. Twist and lock to secure. Fig. 14. 5. Attach 5” diameter metal expandable duct to the plenum. When stretched, it must be long enough to reach the bottom of the support frame. Fig. 14. 6. Duct tape all joints to make them secure and air tight.

NON-DUCTED RECIRCULATION PLENUM

Broan E54000 — NON-DUCTED RECIRCULATION PLENUM diagram (page 11)
Fig. 14
Broan E54000 — NON-DUCTED RECIRCULATION PLENUM diagram (page 11)
Fig. 15

DUCT CONNECTOR

5” METAL EXPANSION DUCT

INSTALL UPPER DECORATIVE FLUE

MOUNTING SCREWS

Broan E54000 — DUCT CONNECTOR diagram (page 11)
Fig. 16

DUCTED HOODS ONLY (8-FOOT AND 9-FOOT CEILINGS)

VENTS “UP”

  • 1. Install and secure the upper flue to the support frame with (2) 2.9x9.5mm mounting screws. Fig. 15.
  • On 8-foot ceilings, install with air vents down.
  • On 9-foot ceilings, install upper flue with air vents up.

VENTS “DOWN”

UPPER

FLUE

(10-FOOT CEILINGS) 2. Discard the upper flue supplied with the hood. Replace with the upper flue supplied with flue extension model FX54SS. 3. Install and secure the upper flue to the support frame with (2) 2.9x9.5mm mounting screws.

Page 12 of the Broan E54000 user manual — WASHERS
Page 12 · cliquer pour agrandir
Page 12

INSTALL THE UPPER DECORATIVE FLUE, cont’d.

MOUNTING SCREWS

Broan E54000 — MOUNTING SCREWS diagram (page 12)
Fig. 17

NON-DUCTED HOODS ONLY (8-FOOT AND 9-FOOT CEILINGS) 4. Install the upper flue with air vent “up”. Secure to the support frame with (2) 2.9x9.5mm mounting screws. Fig. 16. (10-FOOT CEILINGS) 5. Discard the upper flue supplied with the hood. Replace with the upper flue supplied with flue extension model FXN54SS. 6. Install with air vents “up” and secure to the support frame with (2) 2.9x9.5mm mounting screws.

VENTS

“UP”

UPPER

FLUE

Broan E54000 — VENTS diagram (page 12)
Fig. 18

INSTALL LOWER DECORATIVE FLUE

1. Slide the lower flue up and over the upper flue until it contacts the ceiling. Temporarily secure the both halves together with duct tape. Fig. 17.

LOWER

FLUE

INSTALL THE HOOD

TAPE

!

SERRATED

Broan E54000 — SERRATED diagram (page 12)
Fig. 19
1. Secure the hood to the support frame with (6) 3.9x9.5mm mounting screws and (2) serrated washers. Fig. 18.

WASHERS

MOUNTING SCREWS

Page 13 of the Broan E54000 user manual — LINE IN 120 VOLTS - 60 HZ
Page 13 · cliquer pour agrandir
Page 13

CONNECT THE DUCTWORK

6” DUCTED CONNECTION

Duct tape all connecton’s to make them secure and air tight.

Broan E54000 — 6” DUCTED CONNECTION diagram (page 13)
Fig. 20

DUCTED HOODS ONLY 1. Connect 6” diameter metal duct to ducting that discharges to the outside. NON-DUCTED HOODS ONLY 2. Connect 5” diameter expandable metal duct from the non-ducted plenum to the adapter on the blower discharge. DUCTED AND NON-DUCTED HOODS 3. Remove the tape from the lower flue. Lower the flue until is seats on top of the hood. 4. Remove duct tape from upper and lower flue. Lower the flue until it seats on top of the hood.

TAPE

5” NON-DUCTED CONNECTION

INSTALL ELECTRICAL

!

WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring. 1. Remove the wiring box cover. Fig. 20. 2. Run 2-wire plus ground power cable through the round opening in the support frame bracket and into the wiring box. 3. Secure cable to box with an appropriate cable connector. 4. Feed the range hood’s power cable through the hole in the bottom of the wiring box. 5. Secure the cable to the box using the wire clamp (supplied in the parts bag). 6. Connect wires, white-to-white, black-to-black and green-to-ground. 7. Push wiring into the electrical box. Reinstall the wiring box cover. 8. Raise the upper flue and reinstall mounting screws.

Broan E54000 — TAPE diagram (page 13)
Fig. 21

LINE IN 120 VOLTS - 60 HZ

WIRING BOX

COVER

BLK-BLK

WIRE CLAMP

WHT-WHT

GRN-GRN

Page 14 of the Broan E54000 user manual — CLAMP
Page 14 · cliquer pour agrandir
Page 14

INSTALL FILTERS

Broan E54000 — INSTALL FILTERS diagram (page 14)
Fig. 22

(DUCTED AND NON-DUCTED HOODS)

1. To remove the GREASE filter, push in on the metal latch tab and tilt filter downward to remove. 2. To install the GREASE filter, align rear filter tabs with slots in the hood. Depress the metal latch tab, push filter into position and release. Make sure filter is securely engaged after installation.

GREASE FILTERS

Broan E54000 — GREASE FILTERS diagram (page 14)
Fig. 23

(NON-DUCTED HOODS ONLY)

1. To remove the CHARCOAL filter, push in on the front filter latch. Pull the filter down to disengage the rear filter tabs. 2. To install the CHARCOAL filter, align the rear filter tabs with slots in the hood. Push the filter up into place until the front latch snaps securely into the slot. Make sure the filter is securely engaged after assembly. 3. Install GREASE filter after charcoal filter is installed.

CLAMP

NON-DUCTED RECIRCULATION

FILTER

WARRANTY

ONE YEAR LIMITED WARRANTY FOR BROAN PRODUCTS Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Broan products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCAN- DESCENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCT- ING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or instal- lation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or con- sequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

In USA - Broan®, 926 W. State Street, Hartford, WI 53027 (800-558-1711) In Canada - Broan®, 550 Lemire Blvd., Drummondville, QC J2C 7W9 (866-737-7770) www.Broan.com

Poser une question sur : Broan E54000

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan E54000

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan E54000 manuel PDF

44 pages·1.4 MB·Téléviseur à écran plat·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…