FR
Broan logo
Notice d'utilisation officielle

Broan 784

12 pages·1.1 MB·Hotte de ventilation·PDF·ENDEITNLJA
Broan 784
Table des matières 20 sections MODEL 784 CEILING VENTILATOR · READ AND SAVE THESE INSTRUCTIONS · WARNING · CAUTION · … AfficherMasquer
Page 1 of the Broan 784 user manual — CLEANING & MAINTENANCE
Page 1 · cliquer pour agrandir
Page 1

MODEL 784 CEILING VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori- ties. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. Never place a switch where it can be reached from a tub or shower. 9. This unit must be grounded.

TO CLEAN GRILLE: CAUTION: Grille can be cleaned with mild, soapy water (use a mild detergent, such as dishwashing liquid) and dried with a soft cloth. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS.

TO CLEAN FAN ASSEMBLY: Unplug fan assembly. To remove motor plate: Find the single tab on the motor plate (located next to the receptacle). Push up near motor plate tab while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of hous- ing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. OPERATION

Use an on/off switch or speed control to operate this ventilator. See “Connect Wiring” for details. Use of speed controls other than the Broan Models 78V and 78W may cause a motor humming noise. WARRANTY

BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANT- ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan- NuTone), faulty installation or installation contrary to recommended installation instruc- tions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OP- TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUEN- TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of inciden- tal or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or tele- phone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711

CAUTION

!

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Please read specification label on product for further information and requirements.

CLEANING & MAINTENANCE

For quiet and efficient operation, long life, and attractive appear- ance - lower or remove grille and vacuum interior of unit with the dusting brush attachment.

Installer: Leave this manual with the homeowner.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller).

Register your product online atwww.broan.com/register
Page 2 of the Broan 784 user manual — HOUSING MOUNTED DIRECTLY TO JOIST
Page 2 · cliquer pour agrandir
Page 2

TYPICAL INSTALLATIONS

Broan 784 — TYPICAL INSTALLATIONS diagram (page 2)
Fig. 1
Broan 784 — TYPICAL INSTALLATIONS diagram (page 2)
Fig. 2

"I" JOIST "I" JOIST GRILLE

HOUSING MOUNTED DIRECTLY TO JOIST

HOUSING MOUNTED IN ANY LOCATION BETWEEN JOISTS Requires additional framing for mounting tabs.

Broan 784 — HOUSING MOUNTED DIRECTLY TO JOIST diagram (page 2)
Fig. 3
Broan 784 — HOUSING MOUNTED DIRECTLY TO JOIST diagram (page 2)
Fig. 4

HOUSING MOUNTED TO 2x4 TRUSS Requires additional framing for mounting tabs.

SUSPENDED CEILINGS Housing hung with wires - 3-point mount.

Broan 784 — HOUSING MOUNTED DIRECTLY TO JOIST diagram (page 2)
Fig. 5

* Additional framing must be a 2x6 (minimum height), at least 9-inches long.

HOUSING MOUNTED TO “I” JOIST Requires additional framing for mounting tabs.

2x6 (or larger)

Page 3 of the Broan 784 user manual — ADDITIONAL MOUNTING
Page 3 · cliquer pour agrandir
Page 3

INSTALL THE HOUSING

Broan 784 — INSTALL THE HOUSING diagram (page 3)
Fig. 6

EXISTING CONSTRUCTION

- PLEASE NOTE - THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTAL- LATION, MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANNER. (Additional framing must be a 2x6 (minimum height), at least 9-inches long.)

1. Choose the location for your fan in the ceiling. For best possibleperformance, use the shortest possible duct run and a minimum number of elbows.

NEW CONSTRUCTION

2. In attic, position mounting brackets against joist. Trace outline of housing on ceiling material.
Broan 784 — NEW CONSTRUCTION diagram (page 3)
Fig. 7
1. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
3. Set housing aside and cut ceiling opening slightly larger than marked.
Broan 784 — NEW CONSTRUCTION diagram (page 3)
Fig. 8
2. Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling.

BOTTOM EDGE OF JOIST

4. Place housing in opening so that its bottom edge is flush with finished ceiling. Nail to joist through keyhole on both sides. To ensure a noise-free installation, drive another nail through the top hole of each mounting bracket.

Additional positioning feature for 5/8”, 1”, & 1-1/4” thick ceiling material: Holes in corners of housing are labeled with various ceiling material thicknesses. Position housing so bottom edge of joist is visible through a matched set of holes. The housing is now in the proper position for that ceiling material thickness.

Additional positioning feature for 1/2” thick ceiling material: Bend two tabs, on side of housing, 90° outward. Lift housing until tabs contact underside of joist. Mark the keyhole slot on both mounting brackets.

5. Additional mounting holes are provided for installations where access from above is inconvenient or not possible. Nail or screw housing directly to joists or framing.
Broan 784 — BOTTOM EDGE OF JOIST diagram (page 3)
Fig. 9
3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.

ADDITIONAL MOUNTING

HOLES

INSTALL THE DUCTWORK

Broan 784 — ADDITIONAL MOUNTING diagram (page 3)
Fig. 10
4. Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail through the top hole of each mounting tab.
1. Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock into slots in housing. Top of damper/duct connector should be flush with top of housing.
2. Connect 4” round duct to damper/duct connector and extend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.
Page 4 of the Broan 784 user manual — 99044579B
Page 4 · cliquer pour agrandir
Page 4

CONNECT THE WIRING

SERVICE PARTS

1. Wire unit following diagram. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.
KEY NO. PART NO.DESCRIPTION 1 97017032 Grille Assembly 2 97018310 Motor Plate Assembly 3 99080634 Motor 4 99020300 Blower Wheel Assembly 5 99260425 Motor Nut - Hex Keps * 97018326 Blower Assembly - (includes Key Nos. 2 thru 5) 6 99270982 Receptacle 7 98009611 Wire Panel * 97015170 Wire Panel Assembly - (includes Key Nos. 6 & 7) 8 97014922 Housing 9 97003932 Damper/Duct Connector 10 98008868 Wiring Plate 11 99170245 Screw, #8-18 x 3/8 12 99150471 Ground Screw
Broan 784 — CONNECT THE WIRING diagram (page 4)
Fig. 11
Broan 784 — CONNECT THE WIRING diagram (page 4)
Fig. 12

U N I T S W I T C H B O X

* Not shown assembled. Order replacement parts by “PART NO.” - not by “KEY NO.”

Broan 784 — CONNECT THE WIRING diagram (page 4)
Fig. 13

ATTACH THE GRILLE

SLOT IN MOTOR PLATE

Broan 784 — SLOT IN MOTOR PLATE diagram (page 4)
Fig. 14

GRILLE SPRING

1. Squeeze grille springs together and insert springs into slots in motor plate.
Broan 784 — GRILLE SPRING diagram (page 4)
Fig. 15
2. Push grille up against ceiling.

99044579B

Poser une question sur : Broan 784

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Broan 784

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Broan 784 manuel PDF

12 pages·1.1 MB·Hotte de ventilation·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…