Page 1 of the Sygonix Temperature Controller (1761770) user manual — Safety Instructions
Page 1 · cliquer pour agrandir
Page 1
  • Maintenance, modifications and repairs must only be completed by a technician or an authorised repair centre.
  • If you have questions which remain unanswered by these operating instructions, contact our technical support service or other technical personnel.

b) Connected Devices • Also observe the safety and operating instructions of any other devices which are connected to the product.

Operating Instructions Temperature Controller Item No. 1761770

c) (Rechargeable) Batteries • Correct polarity must be observed while inserting the (rechargeable) battery.

Intended Use This product is suitable to switch an electric consumer on or off wirelessly controlled by tem- perature using a suitable receiver (not included) of the RS2W radio switch system. The electric consumer can also be switched on and off manually.

  • The (rechargeable) batteries should be removed from the device if it is not used for a long period of time to avoid damage through leaking. Leaking or damaged (rechargeable) batteries might cause acid burns when in contact with skin, therefore use suitable protective gloves to handle corrupted (rechargeable) batteries.

The temperature controller is powered by two AAA/micro-batteries. The temperature control- ler can be toggled between a heating mode and a cooling mode so that either a heating or a cooling device can be controlled. Switching times can be specified for an individual day, for all weekdays (Monday - Friday) or for the entire week (Monday - Sunday) with 8 different switching programmes that work independently of each other.

  • (Rechargeable) batteries must be kept out of reach of children. Do not leave (rechargeable) batteries lying around, as there is risk, that children or pets swallow them.
  • All (rechargeable) batteries should be replaced at the same time. Mixing old and new (rechargeable) batteries in the device can lead to (rechargeable) battery leakage and device damage.

It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bath- rooms, must be avoided under all circumstances.

  • Rechargeable batteries must not be dismantled, short-circuited or thrown into fire. Never recharge nonrechargeable batteries. There is a risk of explosion!

For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for purposes other than those described above, the product may be damaged. In addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read the instructions carefully and store them in a safe place. Make this product available to third parties only together with its operating instructions.

Features and Functions

Also consider the chapter “Technical data” at the end of these operating instructions.

This product complies with the statutory national and European requirements. All company names and product names are trademarks of their respective owners. All rights reserved.

  • Operation via two batteries/rechargeable batteries of type AAA/Micro
  • Measures and displays temperature and humidity at its location
  • Cooling or heating mode can be toggled

Delivery Content • Temperature controller

  • One receiver can be connected
  • 8 switching programmes (each can be allocated one individual weekday, the period “Monday - Friday” or the period “Monday - Sunday”)
  • Operating instructions
  • Manual operation of the receiver possible

Up-to-date Operating Instructions Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.

  • Receiver is controlled wirelessly (868 MHz technology)
  • Positioning on a table or mounting on a wall

Explanation of Symbols

Getting Started

The symbol with the lightning in the triangle is used if there is a risk to your health, e.g. due to an electric shock.

a) Inserting/Replacing Batteries • Open the battery compartment on the back of the temperature controller and insert two bat- teries of type AAA/micro observing the correct polarity (pay attention to plus/+ and minus/-).

The symbol with the exclamation mark in the triangle is used to indicate important information in these operating instructions. Always read this information carefully.

  • All display segments appear briefly, then the digital clock starts and the first measurement value for temperature and humidity is shown on the right in the display.

The arrow symbol indicates special information and advice on operation.

  • Close the battery compartment again.

The battery needs to be replaced when the display contrast is reduced considerably.

Safety Instructions

The programmed data is preserved when the battery is replaced; you only need to set the time again.

Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting per- sonal injury or damage to property. Such cases will invalidate the warranty/ guarantee.

It is possible to operate the temperature controller with rechargeable batteries. However, the operating time and the display contrast, are greatly reduced due to the lower voltage (battery = 1.5 V, rechargeable battery = 1.2 V). We therefore recom- mend to use only high-quality alkaline batteries instead of rechargeable batteries.

a) General Information • The device is not a toy. Keep it out of the reach of children and pets.

b) Setting the Time • Repeatedly press the “FUNC” button briefly until “CANCEL” appears in the display.

  • Do not leave packaging material lying around carelessly. This may become dangerous playing material for children.
  • Hold the “FUNC“ button pressed (approx. 3 seconds) until the weekday flashes on the top in the display (above the displayed time).
  • Do not place the product under any mechanical stress.
  • If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. Safe operation can no longer be guaranteed if the product:
  • Set the weekday or the period using the “+/ON” or “-/OFF” buttons.

- is visibly damaged,

- is no longer working properly,

- has been stored for extended periods in poor ambient conditions or

- has been subjected to any serious transport-related stresses.

  • Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
  • Briefly press the “FUNC” button to confirm and the hours will flash.
  • The product must not be exposed to extreme temperatures, direct sunlight or strong vibrations. Keep the product away from strong magnetic fields generated by machines, electric motors or loudspeakers.
  • Set the hours with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.
  • Do not operate the product in environments where there are high levels of dust, flammable gases, vapours or solvents. There is a danger of fire and explosion!
  • Briefly press the “FUNC” button to confirm and the minutes will flash.
  • Set the hours minutes with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.
  • Do not use this product in hospitals or medical institutions. Although the sensor emits only relatively weak radio signals, these may lead to the malfunction of lifesupporting systems. The same may also apply to other areas.
  • Briefly press the “FUNC” button to confirm and to exit the setting mode.
  • Consult an expert when in doubt about the operation, safety or connection of the appliance.
Show 7 more labels / short text on this page
“MO” = Monday · “TU” = Tuesday · “WE” = Wednesday · “TH” = Thursday · “FR” = Friday · “SA” = Saturday · “SU” = Sunday
Page 2 of the Sygonix Temperature Controller (1761770) user manual — b) Switching the Consumer On/Off Manually At the receiver
Page 2 · cliquer pour agrandir
Page 2

c) Registering a Receiver for the Temperature Controller

c) Selecting and Setting the Programme • Repeatedly press the “FUNC” button briefly until “AUTO” appears in the display.

The temperature controller can control a receiver of the RS2W radio switch system

(e.g. a radio switch socket that is part of the system). Other receivers cannot be used.

  • Select one of the 8 programmes “PROG1” to “PROG8” with the “+/ON” or “-/OFF” button.
  • Hold the “FUNC“ button pressed (approx. 3 seconds) until the temperature flashes at the left in the display.

Follow the operating instructions of the receiver of the RS2W radio switch system that will be used prior to the registration procedure.

  • Set the temperature with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.

A dimmer of the RS2W radio switch system cannot be used.

During the registration process, maintain a 20 - 30 cm minimum distance between the temperature controller and the receiver. Failing to do this may result in a registra- tion failure.

  • Briefly press the “FUNC” button to confirm and the weekdays will flash.
  • Set the weekday or the period using the “+/ON” or “-/OFF” buttons.

You can set:

  • If the receiver is switched on, switch it off for the moment.

The receiver (e.g. a radio switch socket) must be switched off (LED in the button is

off); otherwise, registration cannot be done.

  • Start the registration procedure at the temperature controller.
  • Repeatedly press the “FUNC” button briefly until “CANCEL” appears on the left in the display.

Hold the “+/ON” button pressed for 2 seconds until the two arrows in the “

” symbol flash alternately. Then release the button.

“MO TU WE TH FR” = Monday to Friday

The temperature controller is now ready to register the receiver.

“MO TU WE TH FR SA SU” = Monday to Sunday

  • Hold the button on the receiver pressed (approx. 3 seconds) until the two arrows in the “
  • Briefly press the “FUNC” button and the hours of the starting time will flash.

” symbol on the temperature controller stop flashing.

You can now enter a time period during which the set temperature should be maintained (e.g. from 8am to 5pm).

  • The receiver switches on to indicate the end of the registration process.

Only one receiver can be registered at the temperature controller (a receiver of the

Keep in mind that the set time periods must not overlap (e.g. if you would set pro-

RS2W radio switch system, but not a dimmer).

gramme 1 from 8 am to 5 pm and programme 2 from 9 am to 3 pm). Otherwise, some switching times or temperatures may not be activated as a result.

If you start a new registration procedure and register another receiver of the RS2W radio switch system, the receiver registered previously will be deleted/overwritten.

If a temperature is to be maintained for the entire day, set the same time for starting and ending time.

d) Deleting a Registered Receiver If the receiver is registered at the temperature controller, proceed as follows:

  • Set the hours of the starting time with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.
  • Start the registration procedure at the temperature controller.
  • Briefly press the “FUNC” button to confirm and the minutes of the starting time will flash.

Repeatedly press the “FUNC” button briefly until “CANCEL” appears on the left in the display.

  • Set the minutes of the starting time with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.

Hold the “+/ON” button pressed for 2 seconds until the two arrows in the “

” symbol flash alternately. Then release the button.

  • Hold the “+/ON” button pressed again for 2 seconds and the registered receiver will be deleted; the right part of the “
  • Briefly press the “FUNC” button to confirm and the hours of the ending time will flash.

” symbol and the two arrows disappear.

  • Set the hours of the ending time with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.
  • Briefly press the “FUNC” button to confirm and the minutes of the ending time will flash.

Operation

  • Set the minutes of the ending time with the “+/ON” or “-/OFF” buttons. For quick adjustment, press and hold down the corresponding button for longer.

a) Selecting Heating or Cooling Mode

In heating mode, the receiver is activated when the measured temperature is below

  • Briefly press the “FUNC” button to confirm and to exit the setting mode.

the set target temperature. This operating mode can be used in conjunction with a heater.

d) Manual Temperature Pre-selection • Repeatedly press the “FUNC” button briefly until “MANU” appears in the display.

In cooling mode, the receiver is activated when the measured temperature is above the set target temperature. This operating mode can be used in conjunction with a cooling unit or fan.

  • Hold the “FUNC“ button pressed (approx. 3 seconds) until the temperature flashes on the left in the display.
  • Repeatedly press the “FUNC” button briefly until “CANCEL” appears in the display.
  • Select the desired temperature with the “+/ON” or “-/OFF” button. For quick adjustment, press and hold down the corresponding button for longer.
  • Hold the “+/ON” and “-/OFF” buttons pressed at the same time to toggle between the heating and cooling mode.
  • Press the “FUNC” button briefly to confirm.

Depending on the mode selected, a corresponding symbol appears in the top left of the display:

Manual temperature pre-selection remains activated for the following 24 hours and

then changes back to automatic operation.

“ ” Heating mode

e) Selecting the Operating Mode (“AUTO”, “MANU”, “CANCEL”) If the temperature controller is not in a setting mode, you can select the operating mode by briefly pressing the “FUNC” button.

“ ” Cooling mode

b) Switching the Consumer On/Off Manually At the receiver

Follow the operating instructions of the receiver of the RS2W radio switch system.

The temperature controller maintains the temperature automatically according to the settings made for times/weekdays in the 8 programmes “PROG1” to “PROG8”.

At the button on the temperature controller

  • Repeatedly press the “FUNC” button briefly until “CANCEL” appears in the display.
  • The registered receiver can be switched on with the “+/ON” button and switched off with the “-/OFF” button.

The temperature controller maintains the temperature after activation of this operating mode for a duration of 24 hours and then changes back to automatic operation.

The temperature controller is deactivated; a switching process is not executed.

Show 10 more labels / short text on this page
“MO” = Monday · “TU” = Tuesday · “WE” = Wednesday · “TH” = Thursday · “FR” = Friday · “SA” = Saturday · “SU” = Sunday · Operating mode “AUTO” · Operating mode “MANU” · Operating mode “CANCEL”
Page 3 of the Sygonix Temperature Controller (1761770) user manual — Technical Data Input voltage ................................. 2x type AAA/Micro batteries
Page 3 · cliquer pour agrandir
Page 3

f) Feedback On the Switching Process A special feature of the RS2W radio switch system, to which the temperature controller be- longs, is that it provides feedback on the successful (or unsuccessful) switching process.

Declaration of Conformity (DOC) Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this product conforms to the 2014/53/EU directive.

The receiver sends information about reception and execution of the switching process back to the sender. In this way, you can always see if the radio receiver (e.g. a radio switch socket) has executed the switching command or not.

Click on the following link to read the full text of the EU declaration of conformity:

www.conrad.com/downloads

The temperature controller indicates this with double arrows:

Enter the product item number in the search box. You can then download the EU declaration of conformity in the available languages.

” Switching process successful, feedback received

” No feedback received from the receiver

Disposal

A reason for missing feedback could be interferences at the same frequency, unfa-

a) Product

vourable reception conditions or similar (see next chapter “Range”) or the receiver is not connected to the mains.

Electronic devices are recyclable waste and must not be disposed of in the house- hold waste. At the end of its service life, dispose of the product in accordance with applicable regulatory guidelines.

g) Installation/Positioning Of the Temperature Controller The temperature controller can be hung from a nail, hook or screw in a wall, using an opening on the back.

Remove any inserted (rechargeable) batteries and dispose of them separately from the product.

Alternatively, unfold the mounting foot at the back and position the temperature controller on a level, stable surface. Protect valuable furniture surfaces by using a suitable mat to prevent scratch marks.

b) (Rechargeable) Batteries

You as the end user are required by law (Battery Ordinance) to return all used (rechargeable) batteries. Disposing of them in the household waste is prohibited.

For operation, choose a place that is not directly exposed to the sun and not located

close to a radiator. This will result in an erroneous temperature or humidity display as well as to an erroneous control of the heating or cooling device connected to the receiver.

Contaminated (rechargeable) batteries are labeled with this symbol to indicate that disposal in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).

h) Range The transmission range of the radio signals between the temperature controller and the re- ceiver is up to 150 m under optimum conditions.

Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever (rechargeable) batteries are sold.

You thus fulfill your statutory obligations and contribute to the protection of the environment.

This value, however, is the so-called “open space range” (the range when transmit-

ter and receiver are in line of sight, without any interference).

Technical Data Input voltage 2x type AAA/Micro batteries

In practice, however, there may be walls, room ceilings, etc. between the transmitter and the receiver, which will reduce the range accordingly.

Temperature control range 0 °C to +50 °C

Due to the different influences on the radio transmission, no specific range can be guaranteed. However, trouble-free operation is usually possible in a single family house.

Switching programmes 8 (daily, weekdays or entire week can be selected)

Range up to 150 m (see chapter “Range”)

Sometimes the range can be considerably reduced due to:

Suitable receivers Radio switches of the RS2W radio switch system

  • Walls, reinforced concrete floors, drywall walls with metal frame construction

(a dimmer cannot be used!)

  • Coated/metallised insulated glass

Number of receivers 1

  • Proximity to metallic & conductive objects (e.g., heating elements)

Transmission/receiving frequency ... 868.000 – 868.600 MHz

  • Proximity to human bodies

Transmission/receiving range max. 150 m (in open area)

  • Other devices on the same frequency (e.g. wireless headphones, wireless speakers)

Transmission power

  • Proximity to electric motors/appliances, transformers, power supplies, computers

Operating/Storage conditions -9 °C to +55 °C, 20 – 95 % RH (non-condensing)

Dimensions (H x W x D) 102 x 63 x 18 mm

Care and Cleaning • The product does not require any maintenance by the user; do not open/disassemble it (except for replacing the batteries). Repair or maintenance work must be carried out by a specialist.

Weight approx. 73 g (without batteries)

  • Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning.
  • You can use a clean, dry, soft cloth for cleaning. Dust can be very easily removed with a soft, clean brush and a vacuum cleaner.
  • Do not press on the display, it could be damaged.

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in- cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the time of printing.

Copyright 2020 by Conrad Electronic SE. *1761770_V2_1120_02_mxs_m_en

“ · “

Poser une question sur : Sygonix Temperature Controller (1761770)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Sygonix Temperature Controller (1761770)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Sygonix Temperature Controller (1761770) manuel PDF

12 pages·251 KB·Contrôleur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…