FR
TFA logo
Notice d'utilisation officielle

TFA 31.3301

28 pages·410 KB·Instruments de mesure·PDF·EN
TFA 31.3301
Table des matières 3 sections Laserdistanzmessgerät · Caution! Risk of injury: · Laser Distance Meter AfficherMasquer
Page 1 of the TFA 31.3301 user manual — Caution!  Risk of injury:
Page 1 · cliquer pour agrandir
Page 1

Laserdistanzmessgerät

  • Laser Distance Meter 1. Before you start using it
  • Please make sure to read the instruction manual carefully. This information will help you to familiarise yourself with your new device, to learn all of its functions and parts, to find out important details about its first use and how to operate it, and to get advice in the event of faults.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • We shall not be liable for any damage occurring as a result of non following of these instructions. Likewise, we take no responsibility for any incorrect readings and for any consequences which may result from them.
  • Please take particular note of the safety advice!
  • Please keep this instruction manual for future reference.

Automatische Abschalt- funktion des Lasers 60 Sekunden

Lasertyp 630…670 nm, < 1 mW

Spannungsversorgung Batterien 2 x 1,5 V AAA

Gehäusemaß 55 x 28 x 114 mm

Gewicht 94 g (nur das Gerät)

  • 2. Field of operation and all the benefits of your new instrument at a glance
  • Measurement of distances
  • Calculation of areas and volumes
  • Pythagoras function for indirect distance measurement of areas difficult to access, like roof edges
  • Shortcut keys for addition and subtraction
  • Memory function of the last 20 measurements
  • Continuous measurement (tracking) and minimum and maximum measurement
  • Backlight
  • With tripod thread
  • Simple and fast operation
  • 3. For your safety
  • This product is exclusively intended for the field of application described above. It should only be used as described within these instructions.
  • Unauthorized repairs, modifications or changes to the product are prohibited.

Caution! Risk of injury:

TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim. Diese Anleitung oder Auszüge daraus dürfen nur mit Zustimmung von TFA Dostmann veröffentlicht werden. Die technischen Daten entsprechen dem Stand bei Drucklegung und können ohne vorherige Benachrichti- gung geändert werden. Die neuesten technischen Daten und Informationen zu Ihrem Produkt finden Sie unter Eingabe der Artikel-Nummer auf unserer Homepage. www.tfa-dostmann.de 10/2014

  • Do not point the laser beam toward people or animals and do not look into the laser beam. It can cause permanent damage to the eye.
Page 2 of the TFA 31.3301 user manual — Laser Distance Meter
Page 2 · cliquer pour agrandir
Page 2

Laser Distance Meter

  • Laser Distance Meter 5. Operation
  • Each button operation is acknowledged with a beep.
  • If the device is on and no measurement is taking place, the laser automatically turns off.
  • Keep this instrument and the battery out of the reach of children.
  • Do not work with the measuring tool in an explosive environment.
  • Batteries must not be thrown into a fire, short-circuited, taken apart or recharged. Risk of explosion!
  • Never use a combination of old and new batteries together, nor batteries of different types.
  • Batteries contain harmful acids. Low batteries should be changed as soon as possible to prevent damage caused by leaking.
  • Wear chemical-resistant protective gloves and safety glasses when handling leaking batteries. Important information on product safety!
  • 6. Getting started
  • Open the battery compartment at the back and insert two new batteries 1.5 V AAA, polarity as illustrated.
  • Press the MEAS button to switch on the instrument.
  • The device will alert you with a beep and the backlight is activated.
  • The laser function is activated. The symbol will be flashing.
  • The unit is ready for use.
  • On the display appear the battery symbol, the measuring unit (default: m) and the measurement basis (default: bottom side).
  • The device will turn off automatically after two minutes.
  • Press and hold the C/OFF button to deactivate the device immediately.
  • Do not place your product near extreme temperatures, vibrations or shocks.
  • Do not leave the unit near objects of high temperature.
  • Do not immerse the unit in water. Water can penetrate and cause malfunction.
  • Protect it from moisture.
  • Measurement error can occur when measuring toward colorless liquids, glass, Styrofoam or similar surfaces at high gloss targets that deflect the laser beam.
  • 6.1 Setting of the measurement basis
  • To start an accurate measurement, you should first set the correct measurement basis.
  • Bottom side measurement basis - The length of the device is included in the measurement.
  • Middle measurement basis - The length of the device starting from the tripod thread is included.
  • Front measurement basis - The measurement is based on the real length.
  • Press the first button on the left side to select between the bottom side measurement basis (default), the middle or the front measurement basis.
  • The measurement basis should be taken into account for each new measurement.
4. Components

A. Buttons (Fig. 1)

A 1: Measurement A 2: Measurement basis A 3: Light + unit A 4: Addition A 5: Subtraction A 6: Functions A 7: Clear + OFF

6.2 Setting of the measuring unit • Press and hold the UNIT button to change between "m" (default), "ft" or "in" as measuring unit.

B. Display (Fig. 2)

  • 6.3 Measuring of the single distance
  • Press the MEAS button.
  • Orientate the device properly.
  • Aim with the red laser point toward the end point of the section to be measured.
  • Press the MEAS button.
  • The device will alert you with a beep and the laser point will be flashing .
  • On the display appears the measured distance.
  • After the measurement the laser automatically turns off.
  • Press the C/OFF button to clear the result.

B 1: Battery symbol B 2: Self-timer active B 3: Continuous measurement B 4: Single distance B 5: Laser active B 6: Front measurement basis B 7: Middle measurement basis B 8: Bottom side measurement basis B 9: Minimum B 10: Measurement area / Volume B 11: Maximum B 12: Indirect measurement 1 + 2 B 13: Memory values B 14: 1. Display line B 15: 2. Display line B 16: 3. Display line B 17: Main display line

TFA 31.3301 — Laser Distance Meter  diagram (page 2)
Fig. 1 · Laser Distance Meter
Page 3 of the TFA 31.3301 user manual — Laser Distance Meter
Page 3 · cliquer pour agrandir
Page 3

Laser Distance Meter

  • Laser Distance Meter
  • The device calculates automatically the area and shows you the result in " m 2 ".
  • The result area appears in the summary line, the single measurements in the first and second line
  • Press the C/OFF button three times to return to normal mode.
  • Troubleshooting
  • If the display shows "Err 21 or 22" after a measurement, press the C / OFF button to delete the last measurement.
  • Start a new measurement process.
  • 6.7 Volume measurement
  • Press the F button twice.
  • On the display appears the symbol for a cuboid .
  • The laser function is activated. The symbol will be flashing.
  • The side to be measured (length) will be flashing.
  • Press the MEAS button.
  • On the display appears the result.
  • The new side to be measured (width) will be flashing.
  • Press the MEAS button.
  • On the display appears the result.
  • The new side to be measured (height) will be flashing.
  • Press the MEAS button.
  • The device calculates automatically the volume and gives the result in "m 3 ".
  • The volume result appears in the summary line, the single measurements in the first, second and third line.
  • Press the C/OFF button four times to return to normal mode.
TFA 31.3301 — Laser Distance Meter  diagram (page 3)
Fig. 2 · Laser Distance Meter
  • 6.4 Continuous measurement (tracking) and maximum and minimum
  • Press and hold the MEAS button to activate the continuous measurement.
  • On the display appear max and min.
  • A continuous tone will sound.
  • A measurement will be automatically started every 0.5 seconds.
  • The unit automatically stores the maximum and minimum distance.
  • The actual measured distance is displayed in the summary line.
  • Press the MEAS button to deactivate the function.
  • The laser function turns off. The symbol disappears.
  • Press the C/OFF button to return to normal mode.
  • 6.5 Addition and subtraction
  • Press the + or - button to add the next measurement to the current measurement or subtract from it.
  • On the display appears in the first line the last measurement and a second line (with + or -) and a summary line.
  • The laser function is activated. The symbol will be flashing.
  • Press the MEAS button to measure a new distance.
  • On the display appears the new measured value in the second line.
  • In the summary line appears the sum or the difference.
  • This process can be repeated if necessary.
  • The sum or the difference appears always in the summary line, the new measured value in the second line and the previous sum or difference in the first line.
  • Press the C/OFF button twice to return to normal mode.
  • 6.8 Indirect measurement 1 - right angle triangle
  • According to the Pythagoras function, the distance can be determined through indirect measurements.
  • Press the F button three times.
  • On the display appears the symbol for a triangle .
  • The laser function is activated. The symbol will be flashing.
  • The side to be measured (a) will be flashing.
  • Press the MEAS button.
  • On the display appears the result.
  • The new side to be measured (c) will be flashing.
  • Press the MEAS button.
  • The device calculates automatically the missing side (b=x) and gives the result in "m".
  • The result appears in the summary line, the single measurements in the first and second line.
  • Press the C/OFF button three times to return to normal mode.
TFA 31.3301 — Laser Distance Meter  diagram (page 3)
Fig. 3 · Laser Distance Meter
  • 6.6 Area measurement
  • Press the F button.
  • On the display appears a rectangle .
  • The laser function is activated. The symbol will be flashing.
  • The side to be measured (length) will be flashing.
  • Press the MEAS button.
  • On the display appears the result.
  • The new side to be measured (width) will be flashing.
  • Press the MEAS button.
TFA 31.3301 — Laser Distance Meter  diagram (page 3)
Fig. 4 · Laser Distance Meter
Page 4 of the TFA 31.3301 user manual — Laser Distance Meter
Page 4 · cliquer pour agrandir
Page 4

Laser Distance Meter

  • Laser Distance Meter 7. Backlight
  • Press the UNIT button to activate or deactivate the backlight.
  • If the UNIT button is not pressed, the backlight switches off automatically after a few seconds.
  • 6.9 Indirect measurement 2 - Determining a distance using 3 measurements
  • Press the F button four times.
  • On the display appears the symbol .
  • The laser function is activated. The symbol will be flashing.
  • The side to be measured (a) will be flashing.
  • Press the MEAS button.
  • On the display appears the result.
  • The new side to be measured (c1) will be flashing.
  • Press the MEAS button.
  • On the display appears the result.
  • The new side to be measured (c2) will be flashing.
  • Press the MEAS button.
  • The device calculates automatically the distance (b2 = x) and gives the result in "m".
  • The result appears in the summary line, the single measurements in the first, second and third line.
  • Press the C/OFF button four times to return to normal mode.
TFA 31.3301 — Laser Distance Meter  diagram (page 4)
Fig. 5 · Laser Distance Meter
8. Fastening • Pull the cord through the attachment hole on the device and knot it.
  • 9. Care and maintenance
  • The sensor is the most delicate part of the device. Please protect the sensor part from dirt.
  • Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
  • Remove the batteries if you do not use the product for a long period of time.
  • 9.1 Battery replacement
  • The battery symbol appears permanently on the display.
  • Change the batteries when the battery symbol appears on the display.
  • Confirm the device is powered off before changing the battery.
  • Open the battery compartment and insert two new batteries 1.5 V AAA, polarity as illustrated.
  • Close the battery compartment again.
  • 6.10 Memory function
  • Press the F button five times.
  • On the display appear MEMO and 01.
  • The laser function turns off. The symbol disappears.
  • Check with the + or - button the last measurements taken.
  • There are twenty data stored.
  • Once a new measurement is taken, this one will be stored and the oldest measurement will be automatically deleted.
  • Press the C/OFF button to return to normal mode.
10. Troubleshooting Problems Solution

No display ➜ Press the MEAS button to switch on the instrument ➜ Ensure that the batteries’ polarities are correct ➜ Change the batteries

  • 6.11 Setting of the self-timer
  • Press the F button six times.
  • On the display appears the symbol for the self-timer beside the battery symbol.
  • The self-timer is set to 5 seconds (default).
  • The laser function is activated. The symbol will be flashing.
  • Press briefly the + or - button, the seconds (1 - 60 seconds) are shown step by step.
  • Press and hold the + or - button until the desired time is indicated.
  • Press the MEAS button to perform a measurement.
  • The countdown starts.
  • The device will alert you with a beep in the last five seconds before the measurement starts.
  • On the display appears the result.
  • Press the C/OFF button to return to normal mode.

Incorrect indication ➜ Change the batteries

Indication 21 ➜ Signal too weak - repeat the process

Indication 22 or 32 ➜ Error in the calculation - Repeat procedure

If your device fails to work despite these measures contact the supplier from whom you pur- chased it.

11. Waste disposal This product has been manufactured using high-grade materials and components which can be recycled and reused.
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Codes d'affichage

Codes d'erreur

La signification des codes d'erreur affichés à l'écran et la façon de les effacer.

CodeSignificationSolution
B11Maximum p.2
B13Memory values p.2
B152. Display line p.2
B17Main display line p.2

Poser une question sur : TFA 31.3301

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le TFA 31.3301

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

TFA 31.3301 manuel PDF

28 pages·410 KB·Instruments de mesure·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…