ADCP-90-216 Issue 2, January 1998 1017825 Page 1 © 1998, ADC Telecommunications, Inc. 7-Inch Fiber Distribution System Splice Module User Manual Content Page INTRODUCTIO N .......................................................................... . 1 Revision Histor y .
ADCP-90-216 Issue 2, January 1998 Page 2 1998, ADC Telecommunications, Inc. List of Changes PAGE IDENTIFIER DESCRIPTION OF CHANGE All pages – Reformat to current standards with editorial and technical changes.
ADCP-90-216 Issue 2, January 1998 Page 3 1998, ADC Telecommunications, Inc. 1. GENERAL 1.01 The AD C 7-Inch Fiber Distribut ion System ( FDS) ( Figure 1 ) pr ovides the te rminati on, splicing, and storage requirements of a large fiber optic cable system.
ADCP-90-216 Issue 2, January 1998 Page 4 1998, ADC Telecommunications, Inc. 3.03 Splice trays are available in nine configurations which provide splice chips to support individual splices.
ADCP-90-216 Issue 2, January 1998 Page 5 1998, ADC Telecommunications, Inc. 4. DESCRIPTION 4.01 The splice module requires a 7-inch (17.8 cm) mounting space withi n the frame. Major components of the splice module are shown in Figure 3 and are described in the following paragraphs.
ADCP-90-216 Issue 2, January 1998 Page 6 1998, ADC Telecommunications, Inc. Table 1. Splice Module Specifications FEATURE SPECIFICATION Dimensions Height 7 in.
ADCP-90-216 Issue 2, January 1998 Page 7 1998, ADC Telecommunications, Inc. C. Splic e Drawers 4.04 Th e splic e modul e contain s u p to six splice drawers.
ADCP-90-216 Issue 2, January 1998 Page 8 1998, ADC Telecommunications, Inc. 4. If applicable, remove the vertical cable guide from each side of th e frame position in which the splice module is being installed. 5. Place the splice module in its assigned position in the frame.
ADCP-90-216 Issue 2, January 1998 Page 9 1998, ADC Telecommunications, Inc. #12-24 SCREW (2 PLACES EACH SIDE) INTERBAY MANAGEMENT PANEL 1217-A VERTICAL CABLE GUIDE MOUNTING HOLES VERTICAL CABLE GUIDE MOUNTING HOLES VERTICAL CABLE GUIDE Figure 5. Vertical Cable Guide Installation in an Equipment Rack C.
ADCP-90-216 Issue 2, January 1998 Page 10 1998, ADC Telecommunications, Inc. Danger : Infrared radiation is invisible and can seriously damage th e retina of the eye. Do not look into the optical bulkhead of an operational transmitter, or into the launching (output ) end of an active fiber.
ADCP-90-216 Issue 2, January 1998 Page 11 1998, ADC Telecommunications, Inc. 5.07 One cable clamp kit is currently available. The OS P cable clamp kit accommodates cables with outside diameters that range from 0.5 to 0.8 inches (13-20 mm). 5.08 Select a grommet that when placed around the cable, has a gap o f nearly 0 to 0.
ADCP-90-216 Issue 2, January 1998 Page 12 1998, ADC Telecommunications, Inc. D. Fibe r Storage 5.11 Ope n the rear door about 2 inches (5 cm) and lift it from its hinges. Place the cover where it will not be scratched or damaged. 5.12 Route OSP/IFC fibers through a side access opening in the chassis to the assigned drawer of the splice module.
ADCP-90-216 Issue 2, January 1998 Page 13 1998, ADC Telecommunications, Inc. 6. SPLICING 6.01 Th e splice module accommodates most splicing methods which should be performed in accordanc e with local practices. The splice tray splice chip should be selected to match the local splice method.
ADCP-90-216 Issue 2, January 1998 Page 14 1998, ADC Telecommunications, Inc. 6.07 Coil the service loop clockwise (if the fiber entry is from the right) or counter-clockwise (if the fiber entry is from the left), around the radius limiters in the splice drawer.
ADCP-90-216 Issue 2, January 1998 Page 15 8. CUSTOMER SUPPORT SERVICES 8.01 ADC offers the follow ing customer support services. For calls originating in the U.S.A. or Canada, dial 1-800-366-3891 , then request the extension listed. For calls originating outside the U.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ADC P-90-216 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ADC P-90-216 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ADC P-90-216, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ADC P-90-216 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ADC P-90-216, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ADC P-90-216.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ADC P-90-216. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ADC P-90-216 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.