FR
Sharp logo
Notice d'utilisation officielle

Sharp UA-PF40E

104 pages·5.4 MB·Purificateur d'air·PDF·ENITJA
Sharp UA-PF40E
Table des matières 49 sections UA-PF40E Operation Manual · Air Purifier · EN ES DE PT FR PL NL · UA-PF40E · … AfficherMasquer
Page 1 of the Sharp UA-PF40E user manual — Air Purifier
Page 1 · cliquer pour agrandir
Page 1
Sharp UA-PF40E — UA-PF40E Operation Manual diagram (page 1)
Fig. 1 · UA-PF40E Operation Manual

UA-PF40E Operation Manual

Air Purifier

EN ES DE PT FR PL NL

Page 2 of the Sharp UA-PF40E user manual — UA-PF40E Operation Manual
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Sharp UA-PF40E user manual — UA-PF40E Operation Manual
Page 3 of the Sharp UA-PF40E user manual — Free standing type
Page 3 · cliquer pour agrandir
Page 3

R

UA-PF40E

AIR PURIFIER OPERATION MANUAL

“Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation.

Sharp UA-PF40E — R diagram (page 3)
Fig. 2

*The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm3, which is measured around the centre of a room with the “high-density plasmacluster 7000” applicable fl oor area (at 1.2 m height above the fl oor) at the medium wind volume in air purifying mode, when an air purifi er using the high-density plasmacluster ion evolving device is placed close to a wall. This product is equipped with a device corresponding to this capacity.

Free standing type

Page 4 of the Sharp UA-PF40E user manual — Please read before operating your new Air Purifi er
Page 4 · cliquer pour agrandir
Page 4

Please read before operating your new Air Purifi er

The air purifi er draws in room air from the air intake, passes the air through a Pre- Filter, a Deodorizing Filter and a HEPA Filter inside of the unit, then discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the fi lter.

The Deodorizing Filter gradually absorbs odours as they pass through the fi lter.

Some odours absorbed by the fi lters may break down over time, resulting in additional odour. Depending on the usage environment, especially when the product is used in extreme environments (significantly more severe than normal household use), this odour may become strong in a shorter period than expected. If the odour persists, the fi lters should be replaced.

  • The air purifi er is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke).
Sharp UA-PF40E — Please read before operating your new Air Purifi er diagram (page 4)
Fig. 3 · Please read before operating your new Air Purifi er
Page 6 of the Sharp UA-PF40E user manual — IMPORTANT SAFETY INSTRUCTIONS
Page 6 · cliquer pour agrandir
Page 6

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should be followed, including the following:

  • Read all instructions before using the unit.
  • Use only a 220-240 volt outlet.
  • Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened.
  • Periodically remove dust from the power plug.
  • Do not insert fi ngers or foreign objects into the intake or air outlet.
  • When removing the power plug, always hold the plug and never pull the cord. Electric shock and/or fi re from short circuit may occur as a result.
  • Be careful not to damage the power cord, it may cause electric shock, excess heat or fi res.
  • Do not remove the plug when your hands are wet.
  • Do not use this unit near gas appliances or fi replaces.
  • Remove the power plug from the wall outlet before cleaning the unit and when not using the unit. Electric shock from bad insulation and/or fi re from short circuit may occur as a
  • result.
  • When cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electric shock and/or fi re from a short circuit may result.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service agent, Sharp Authorized Service Centre or similarly qualifi ed person in order to avoid a hazard.
  • Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity conditions, such as a bathroom.
  • Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
  • Only a Sharp Authorized Service Centre should service this air purifi er. Contact the nearest Service Centre for any problems, adjustments, or repairs.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the unit and radio/TV receiver.
  • Connect the equipment into an outlet on a circuit diff erent from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
Page 7 of the Sharp UA-PF40E user manual — FILTER GUIDELINES
Page 7 · cliquer pour agrandir
Page 7

CAUTIONS CONCERNING OPERATION

  • Do not block the air intake and/or air outlet.
  • Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam.
  • Do not lay the unit down when using.
  • Always hold the handle on the back of the unit when moving it.
  • Do not use without the fi lters installed inside the unit.
  • Do not wash and reuse the HEPA fi lter and the Deodorizing fi lter. Not only does it not improve filter performance, it may cause electric shock or

malfunction.

INSTALLATION GUIDELINES

  • When using the unit, place it away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference.
  • Avoid using in locations where furniture, fabrics or other items may come in contact with and restrict the air intake and/or air outlet.
  • Avoid using in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate condition is at room temperature 0 – 35 ºC.
  • Place on a stable surface with suffi cient air circulation. When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
  • Avoid locations where grease or oily smoke is generated. The unit surface may crack as a result.
  • The dust collecting ability of the unit is eff ective even when the unit is close to the wall, the surrounding walls and fl oor may get dirty. Please place the unit at a distance from the wall. The wall directly behind the air outlet may become dirty over time. When using the unit for an extended period of time at the same location, periodically clean the walls adjacent to it.

FILTER GUIDELINES

  • Follow the instructions in this manual for correct care and maintenance of the fi lter.
Page 8 of the Sharp UA-PF40E user manual — CAUTIONS CONCERNING OPERATION
Page 8 · cliquer pour agrandir
Page 8
Sharp UA-PF40E — CAUTIONS CONCERNING OPERATION diagram (page 8)
Fig. 4
Sharp UA-PF40E — CAUTIONS CONCERNING OPERATION diagram (page 8)
Fig. 5

7 DUST SIGN Indicates the air purity of the room in 3 levels with colour changes.

1Main Unit9Handle 2Air Outlet10Dust Sensor / Dust Sensor Filter 3OFF TIMER Button (Press 3 sec.) LIGHT ON/OFF Button 11HEPA Filter 4MODE Button, Indicator Light (green) (Press 3 sec.) Plasmacluster Ion ON/OFF Button12Deodorizing Filter 13Upper Tabs 5CLEAN ION SHOWER Button, Indicator Light (green)14Back Panel (Pre-Filter) 6POWER ON/OFF Button15Bottom Tabs 7DUST SIGN16Power Cord 8PLASMACLUSTER SIGN17Plug
Sharp UA-PF40E — CAUTIONS CONCERNING OPERATION diagram (page 8)
Fig. 6
Page 9 of the Sharp UA-PF40E user manual — 2 Remove the plastic bag and
Page 9 · cliquer pour agrandir
Page 9
Sharp UA-PF40E — 3 Place the Filter inside the main diagram (page 9)
Fig. 7 · 3 Place the Filter inside the main

Be sure to remove the power plug from the wall outlet.

To maintain the quality of the fi lter, it is installed in the main unit and packed in plastic bag. Be sure to remove the fi lter from the plastic bag before using the unit.

1 Remove the Back Panel.

3 Place the Filter inside the main

unit.

Do not install the fi lter backwards or the unit will not operate properly.

Sharp UA-PF40E — 3 Place the Filter inside the main diagram (page 9)
Fig. 8 · 3 Place the Filter inside the main
Sharp UA-PF40E — 3 Place the Filter inside the main diagram (page 9)
Fig. 9 · 3 Place the Filter inside the main

2 Remove the plastic bag and

4 Replace the Back Panel to the

take out the Filter.

main unit.

Sharp UA-PF40E — 2 Remove the plastic bag and diagram (page 9)
Fig. 10 · 2 Remove the plastic bag and
Sharp UA-PF40E — 2 Remove the plastic bag and diagram (page 9)
Fig. 11 · 2 Remove the plastic bag and

When replacing the fi lter, making a memo of the start of use date is recommended.

Upper Tabs · Bottom Tabs

Page 10 of the Sharp UA-PF40E user manual — OFF TIMER
Page 10 · cliquer pour agrandir
Page 10
Sharp UA-PF40E — CLEAN AIR diagram (page 10)
Fig. 12

CLEAN AIR

START

STOP

Sharp UA-PF40E — CLEAN AIR diagram (page 10)
Fig. 13
  • Select the desired fan speed.
  • Unless the power cord has been unplugged, the operation starts in the previous mode it was operated in.

CLEAN ION SHOWER

Releases high-density Plasmacluster ions and discharges strong air fl ow for 60 minutes.

START

  • If Plasmacluster Ion is OFF, Plasmacluster Ion will not be released.
  • When the operation fi nishes, the unit will return to the prior operation mode. It is able to change the other mode or turn off during this mode.

FAN SPEED

AUTO

  • The fan speed is automatically switched depending on the amount of impurities in the air. The sensors detect impurities for efficient air purfication.

SLEEP

AUTO SLEEP MED MAX

  • The unit will operate very quietly, and the fan speed is automatically switched depending on the amount of impurities in the air. DUST /PLASMACLUSTER SIGN go off automatically. Even though the indicator is off , Plasmacluster Ion is released into air unless Plasmacluster Ion is turned off by

OFF TIMER

Select the time turning off the unit during operation. The unit automatically stops once the selected time is reached.

  • 2h
  • 4h
  • 8h CANCEL
Page 11 of the Sharp UA-PF40E user manual — (with the unit OFF) 1
Page 11 · cliquer pour agrandir
Page 11
Sharp UA-PF40E — LIGHT CONTROL diagram (page 11)
Fig. 14

LIGHT CONTROL

You can turn off the DUST/PLASMACLUSTER SIGN when they are lighting up.

ON

OFF

  • When the unit starts operation, the DUST/PLASMACLUSTER SIGN always light up.
  • In SLEEP mode, Light Control button doesn’t operate.

more than 3 sec.

more than 3 sec.

PLASMACLUSTER ION ON/OFF

When Plasmacluster Ion is ON, the PLASMACLUSTER SIGN will turn on. (blue)

(In operation) ON OFF

more than 3 sec. more than 3 sec.

ADJUSTMENT OF SENSOR DETECTION SENSITIVITY

Set to “Low” if the DUST SIGN is constantly red to reduce sensitivity, and set to “High” if the DUST SIGN is constantly green to increase sensitivity.

(with the unit OFF) 1

more than 3 sec.

Select the sensor detection sensitivity.

  • If the Power ON/OFF Button is not pressed within 8 seconds of adjusting sensor sensitivity, the setting will be saved automatically.
  • The sensor sensitivity setting will be saved even if the unit is unplugged.

High · Standard · Low

Page 12 of the Sharp UA-PF40E user manual — CAUTION
Page 12 · cliquer pour agrandir
Page 12
Sharp UA-PF40E — FILTERS diagram (page 12)
Fig. 15

To maintain optimum performance of this air purifi er, please clean the unit including the fi lter periodically. Be sure to disconnect the power cord from the wall outlet before performing any maintenance.

Sharp UA-PF40E — FILTERS diagram (page 12)
Fig. 16

Gently remove dust from the back panel by using a vacuum cleaner attachment or similar tool. BACK PANEL (Pre-fi lter)

Do not apply excessive pressure, when scrubbing the back panel.

1. Add a small amount of kitchen detergent to water and soak for about 10 minutes.
2. Rinse off the kitchen detergent with clean water.
3. Completely dry the fi lter in a well-ventilated area.

FILTERS

Gently remove dust from HEPA Filter and Deodorizing Filter with a vacuum cleaner attachment or similar tool.

CAUTION

Do not WASH in water and DRY in the sun. The fi lters are fragile, be careful not to apply too much force.

  • HEPA Filter

Apply the maintenance only on the side with the tag. Do not clean the opposite side; otherwise, the fi lter will be damaged.

The maintenance can be applied to the both sides.

UNIT

Wipe with a dry, soft cloth For stubborn stains or dirt, use a soft cloth dampened with warm water.

Sharp UA-PF40E — UNIT diagram (page 12)
Fig. 17

CAUTION

  • Do not use volatile fl uids Benzine, paint thinner, polishing powder, etc., may damage the surface.
  • Do not use detergents Detergent ingredients may damage the unit.

Tag HEPA Filter

Page 13 of the Sharp UA-PF40E user manual — Disposal of Filter
Page 13 · cliquer pour agrandir
Page 13
Sharp UA-PF40E — SENSOR diagram (page 13)
Fig. 18

Be sure to remove the power plug from the wall outlet.

SENSOR

1. Remove the Back Panel.
Sharp UA-PF40E — SENSOR diagram (page 13)
Fig. 19
2. Remove the Dust Sensor Filter.
3. If it is very dirty, wash it with water and dry it thoroughly.

FILTER REPLACEMENT GUIDELINES

Replacement timing About 10 years after operating

Do not wash and reuse the fi lters

The fi lter life and replacement period are based on the condition of smoking 5 cigarettes per day and the dust and odour collection power is reduced by half compared with that of new fi lter. Filter life varies depending on the room environment, usage, and location of the unit. We recommend to replace the fi lter more frequently if the product is used in a condition signifi cantly severer than normal household use.

REPLACING THE FILTER

Replacement Filter

Model:UZ-PM5HF

Model:UZ-PM5DF

  • HEPA Filter : 1 unit
  • Deodorizing Filter : 1 unit

See page E-5 for directions on how to install the fi lter when replacing.

  • Please consult your dealer for purchase of replacement fi lter.
  • Use only fi lters designed for this product.

Disposal of Filter

Please dispose of the replaced fi lter according to the local disposal laws and regulations.

HEPA Filter materials :

Deodorizing Filter materials :

  • Filter : Polypropylene
  • Frame : Polyester
  • Polypropylene, Polyester, Activated charcoal

Dust Sensor · Dust Sensor Filter

Page 14 of the Sharp UA-PF40E user manual — TROUBLESHOOTING
Page 14 · cliquer pour agrandir
Page 14

TROUBLESHOOTING

Before calling for service, please review the Troubleshooting list below, since the problem may not be a unit malfunction.

SYMPTOM REMEDY (not a malfunction)

Odours and smoke are not removed.

  • Clean or replace the fi lters if they appear to be heavily soiled. (Ref. E-8,E-9)

The DUST SIGN illuminates green even when the air is impure.

  • The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again.

The DUST SIGN illuminates orange or red even when the air is clean.

  • Sensor operation is aff ected if the dust sensor fi lter is dirty or clogged. Gently clean the dust sensor fi lter. (Ref. E-9).

A clicking or ticking sound is heard from the unit.

  • Clicking or ticking sounds may be audible when the unit is generating ions.
  • The discharged air has an odour.
  • Check to see if the fi lters are heavily soiled.
  • Clean or replace the fi lters.
  • Plasmacluster Air Purifi ers emit small traces of ozone which may produce an odour. These ozone emissions are well below safety level.

The unit does not operate properly when cigarette smoke is in the air.

  • Is the unit installed in a location that is diffi cult for the sensor to detect cigarette smoke?
  • Is the dust sensor fi lter blocked or clogged? (In this case, clean the fi lter.) (Ref. E-9)

The DUST SIGN is turned off . • Check to see if the Lights OFF Mode is selected.

Press for 3 seconds to turn light ON.

(Ref. E-7) • Check to see if the SLEEP mode is selected. The DUST/PLASMACLUSTER SIGN are turned off automatically

after the SLEEP mode is selected.

The DUST SIGN changes colour frequently.

  • The DUST SIGN automatically changes colours as impurities are detected by the dust sensor. The sensor detection sensitivity can be adjusted lower. (Ref.E-7)
Page 15 of the Sharp UA-PF40E user manual — SPECIFICATIONS
Page 15 · cliquer pour agrandir
Page 15
Sharp UA-PF40E — SPECIFICATIONS diagram (page 15)
Fig. 20
Sharp UA-PF40E — SPECIFICATIONS diagram (page 15)
Fig. 21

AUTO RESTART After a power failure, automatically resume the operation when the power recovers.

Auto Restart can be set. • Even when the plug is unplugged or the breaker is thrown during operation, the unit resumes at the previous operation mode and settings if the power recovers.

ON OFF (with the unit OFF) (with the unit OFF)

(simultaneously for more than 3 sec.) (simultaneously for more than 3 sec.)

If the , , lamps light up for 10 seconds, the setting is completed.

SPECIFICATIONS

Sharp UA-PF40E — SPECIFICATIONS diagram (page 15)
Fig. 22

*1 The fan speed is automatically switched depending on the amount of impurities in the air.

*2 Size of a room which is appropriate for operating the unit at maximum fan speed. • It indicates the space where a certain amount of dust particles can be removed in 30 minutes (JEM1467).

*3 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the centre of the room (at a height of approximately 1.2 meters from the fl oor) when the product is placed next to a wall and run at the MED fan speed.

Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 1.0W of standby power. For energy saving, unplug the power cord when the unit is not in use.

Page 16 of the Sharp UA-PF40E user manual — SPECIFICATIONS
Page 16 · cliquer pour agrandir
Page 16

A. Information on Disposal for Users (private households)

1. In the European Union

IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE! Used electrical and electronic equipment should always be collected and treated SEPA- RATELY in accordance with local law. Separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing fi nal disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available. If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal. ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES; FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law. The symbol shown above appears on electrical and electronic equipment (or the packag- ing) to remind the users of this. Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment. Return is free of charge. If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.

2. In other Countries outside the EU

If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.

For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch

B. Information on Disposal for Business Users.

1. In the European Union

If the product is used for business purposes and you want to discard it:

Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.

For Spain: Please contact the established collection system or your local authority for take-back of your used products.

2. In other Countries outside the EU

If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Odours and smoke are not removed.• Clean or replace the fi lters if they appear to be heavily soiled. (Ref. E-8,E-9) p.14
The DUST SIGN illuminates green even when the air is impure.• The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again. p.14
The DUST SIGN illuminates orange or red even when the air is clean.• Sensor operation is aff ected if the dust sensor fi lter is dirty or clogged. Gently clean the dust sensor fi lter. (Ref. E-9). p.14
A clicking or ticking sound is heard from the unit.• Clicking or ticking sounds may be audible when the unit is generating ions. p.14
The discharged air has an odour.• Check to see if the fi lters are heavily soiled. • Clean or replace the fi lters. • Plasmacluster Air Purifi ers emit small traces of ozone which may produce an odour. These ozone emissions are well below safety level. p.14
The unit does not operate properly when cigarette smoke is in the air.• Is the unit installed in a location that is diffi cult for the sensor to detect cigarette smoke? • Is the dust sensor fi lter blocked or clogged? (In this case, clean the fi lter.) (Ref. E-9) p.14
The DUST SIGN is turned off .• Check to see if the Lights OFF Mode is selected. Press for 3 seconds to turn light ON. (Ref. E-7) • Check to see if the SLEEP mode is selected. The DUST/PLASMACLUSTER SIGN are turned off automatically after the SLEEP mode is selected. p.14
The DUST SIGN changes colour frequently.• The DUST SIGN automatically changes colours as impurities are detected by the dust sensor. The sensor detection sensitivity can be adjusted lower. (Ref.E-7) p.14
AUTO RESTART After a power failure, automatically resume the operation when the power recovers. ON (with the unit OFF) (simultaneously for more than 3 sec.) If the , , lamps lig for 10 seconds, the setting is compAuto Restart can be set. • Even when the plug is unplugged or the breaker is thrown during operation, the unit resumes at the previous operation mode and settings if the power recovers. OFF (with the unit OFF) (simultaneously for more than 3 sec.) ht up leted. p.15

Poser une question sur : Sharp UA-PF40E

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Sharp UA-PF40E

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Sharp UA-PF40E manuel PDF

104 pages·5.4 MB·Purificateur d'air·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…