FR
Sharp logo
Notice d'utilisation officielle

Sharp UA-HG40E

144 pages·6.9 MB·Purificateur d'air·PDF·ENITJA
Sharp UA-HG40E
Table des matières 80 sections UA-HG60E, UA-HG50E, UA-HG40E Operation Manual · Air Purifier · EN ES DE PT FR PL NL · UA-HG60E UA-HG50E UA-HG40E · … AfficherMasquer
UA-HG60E, UA-HG50E, UA-HG40E Operation Manualp.1Air Purifierp.1EN ES DE PT FR PL NLp.1UA-HG60E UA-HG50E UA-HG40Ep.3AIR PURIFIER with Humidifying Function OPERATION MANUALp.3Free standing Typep.3FEATURESp.4(UA-HG60E / UA-HG50E)p.4When there is no movement in the sensory areap.47detection by 6 sensorsp.4Please read before operatingp.5CONTENTSp.5your new Air Purifi erp.5HEPA Filterp.5Deodorizing Filterp.5Pre-Filterp.5IMPORTANT SAFETY INSTRUCTIONSp.6CAUTIONS CONCERNING OPERATIONp.6INSTALLATION GUIDELINESp.7FILTER GUIDELINESp.7PREPARATIONp.10FILTER INSTALLATIONp.10OPERATIONp.10START/STOPp.10INTELLIGENT MODE (UA-HG60E / UA-HG50E)p.10START STOPp.10CLEAN ION SHOWER MODE AUTO MODE (UA-HG40E)p.10PLASMACLUSTER ION SPOT MODEp.11HUMIDIFICATION SETTINGp.11REFILLING THE WATER TANKp.11SELECTING MODEp.11SLEEP POLLEN MAX MED LOWp.11ON OFFp.11CHILD LOCKp.11ON CANCELLATIONp.11PATROLLING FUNCTIONp.12DRY AND LOW TEMPERATURE PATROLLINGp.12HIGH TEMPERATURE AND HIGH HUMIDITY PATROLLINGp.13HOW TO CHANGE VARIOUS SETTINGSp.14Forwardp.14Reversep.14Setp.14UA-HG40Ep.14Function Settingp.15Sound Indicator Settingp.15Cancellation (default)p.15ONp.15Auto Restartp.15Cancellationp.15ON (default)p.15Adjusting Sensor Sensitivity (F4-F7)p.15Light Sensor Lowp.15Dust(sensitive) Sensor Standard (default)p.15Odour Sensor (UA-HG60E / UA-HG50E) Highp.15ON( Standard sensing time ) (default)p.15Motion Sensor (UA-HG60E / UA-HG50E)p.15ON( Longer sensing time )p.15Patrolling Function Settingp.15ON( notifi es with Patrolling Light only ) (default)p.15CARE AND MAINTENANCEp.16FILTER INDICATORp.16WATER TANKp.16RESETp.16CARE INDEXp.16UNIT / BACK PANELp.16Back Panelp.16CAUTIONp.16Sensor Filterp.16FILTER REPLACEMENT HEPA FILTER / DEODORIZING FILTERp.18LIFE OF FILTERSp.18UZ-HG6DF UZ-HG4DF UZ-HG4DFp.18UZ-HG6MF UZ-HG6MF UZ-HG6MFp.18How to install the Float and the Tray Panelp.18Tray Panelp.18UA-HG60Ep.18Humidifying Filterp.18UA-HG50E / UA-HG40Ep.18Floatp.18TROUBLESHOOTINGp.19SPECIFICATIONSp.20
Page 1 of the Sharp UA-HG40E user manual — UA-HG60E, UA-HG50E, UA-HG40E Operation Manual
Page 1 · cliquer pour agrandir
Page 1
Sharp UA-HG40E — UA-HG60E, UA-HG50E, UA-HG40E Operation Manual diagram (page 1)
Fig. 1 · UA-HG60E, UA-HG50E, UA-HG40E Operation Manual

UA-HG60E, UA-HG50E, UA-HG40E Operation Manual

Air Purifier

EN ES DE PT FR PL NL

Page 2 of the Sharp UA-HG40E user manual — UA-HG60E, UA-HG50E, UA-HG40E Operation Manual
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Sharp UA-HG40E user manual — UA-HG60E, UA-HG50E, UA-HG40E Operation Manual
Page 3 of the Sharp UA-HG40E user manual — Free standing Type
Page 3 · cliquer pour agrandir
Page 3

UA-HG60E UA-HG50E UA-HG40E

AIR PURIFIER with Humidifying Function OPERATION MANUAL

"Plasmacluster" and "Device of a cluster of grapes" are trademarks of Sharp Corporation.

Sharp UA-HG40E — UA-HG60E UA-HG50E UA-HG40E diagram (page 3)
Fig. 2

Free standing Type

* The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm3, which is measured around the center of a room with the “high-density plasmacluster 7000” applicable floor area (at 1.2 m height above the floor) when the product is placed close to a wall at the MED mode setting.

Page 4 of the Sharp UA-HG40E user manual — 7detection by 6 sensors
Page 4 · cliquer pour agrandir
Page 4

FEATURES

A unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster + Humidifi cation

FRESHENS By emitting a balance of positive and negative ions, Plasmacluster air treatment is a natural process.

HUMIDIFIES Controls humidity by sensing temperature and humidity automatically.

TRAPS DUST Pre-filter traps dust larger than approx 240 micron particles.

*1: VOC, NOx, SOx. The deodorizing performance for a single component odours substance in a 1m3 test container may be different than the deodorizing performance in actual use. *2: When air is circulated through the fi lter system. Sensor Technology continuously monitors air quality and room condition, and automatically adjusts operation.

DECREASES ODOURS Deodorizing fi lter absorbs harmful gases*1 and many common household odours.

REDUCES TINY DUST, POLLEN & MOLD*2 HEPA fi lter traps 99.97% of particles as small as 0.3 microns.

INTELLIGENT MODE When a person or pet is in the sensory area*4

(*4Ref.E-5)

(UA-HG60E / UA-HG50E)

  • When there is little movement of a person or pet (example: when sleeping), automatically switches to quiet air fl ow.
  • When the room is dark, the Front Display, Cleanliness Monitor and Air Outlet LED turn off automatically.

6 sensors sensing 7 factors precisely con- trol automatic opera- tion.

When there is no movement in the sensory area

  • The Front Display, Cleanliness Monitor and Air Outlet LED turn off, humidifying stops, and the unit switches to minimum airfl ow to save power consumption.
  • When room humidity is over 80% and the room is bright, Plasmacluster Ions are emitted with strong airfl ow.

7detection by 6 sensors

SENSORDETECTION Dust (sensitive)PM2.5 (particulate matter less than 2.5 microns), etc. Tobacco smoke, house dust (dirt, mite feces and remains, mold spores, pollen) OdourTobacco, cosmetic, alcohol, spray, and other odours TemperatureRoom temperature HumidityRoom humidity LightRoom brightness Motion*3Movement of persons or pets

Front Display, Cleanli- ness Monitor

  • When in Intelligent mode you can manually switch humidifying ON or OFF (Ref. E-8)
  • Front Display and Air Outlet LED automatically switch ON and OFF based on room brightness. (When light control is set to "Auto". Ref. E-11)
  • When the Motion Sensor senses that no one has been in the room for a set interval of time it determines that the room is unoccupied.
  • You can change brightness of Display / Monitor, sensor sensitivity, and Motion Sensor sensing time. (Ref. E-11, E-12)
  • Motion sensor may sense movement other than persons or pets. (waving curtain etc.)

*3: Senses only when Intelligent mode is in operation.

Air Outlet LED

Page 5 of the Sharp UA-HG40E user manual — Table des matières
Page 5 · Table des matières
Table des matières

Table des matières

UA-HG60E, UA-HG50E, UA-HG40E Operation Manualp.1Air Purifierp.1EN ES DE PT FR PL NLp.1UA-HG60E UA-HG50E UA-HG40Ep.3AIR PURIFIER with Humidifying Function OPERATION MANUALp.3Free standing Typep.3FEATURESp.4(UA-HG60E / UA-HG50E)p.4When there is no movement in the sensory areap.47detection by 6 sensorsp.4Please read before operatingp.5CONTENTSp.5your new Air Purifi erp.5HEPA Filterp.5Deodorizing Filterp.5Pre-Filterp.5IMPORTANT SAFETY INSTRUCTIONSp.6CAUTIONS CONCERNING OPERATIONp.6INSTALLATION GUIDELINESp.7FILTER GUIDELINESp.7PREPARATIONp.10FILTER INSTALLATIONp.10OPERATIONp.10START/STOPp.10INTELLIGENT MODE (UA-HG60E / UA-HG50E)p.10START STOPp.10CLEAN ION SHOWER MODE AUTO MODE (UA-HG40E)p.10PLASMACLUSTER ION SPOT MODEp.11HUMIDIFICATION SETTINGp.11REFILLING THE WATER TANKp.11SELECTING MODEp.11SLEEP POLLEN MAX MED LOWp.11ON OFFp.11CHILD LOCKp.11ON CANCELLATIONp.11PATROLLING FUNCTIONp.12DRY AND LOW TEMPERATURE PATROLLINGp.12HIGH TEMPERATURE AND HIGH HUMIDITY PATROLLINGp.13HOW TO CHANGE VARIOUS SETTINGSp.14Forwardp.14Reversep.14Setp.14UA-HG40Ep.14Function Settingp.15Sound Indicator Settingp.15Cancellation (default)p.15ONp.15Auto Restartp.15Cancellationp.15ON (default)p.15Adjusting Sensor Sensitivity (F4-F7)p.15Light Sensor Lowp.15Dust(sensitive) Sensor Standard (default)p.15Odour Sensor (UA-HG60E / UA-HG50E) Highp.15ON( Standard sensing time ) (default)p.15Motion Sensor (UA-HG60E / UA-HG50E)p.15ON( Longer sensing time )p.15Patrolling Function Settingp.15ON( notifi es with Patrolling Light only ) (default)p.15CARE AND MAINTENANCEp.16FILTER INDICATORp.16WATER TANKp.16RESETp.16CARE INDEXp.16UNIT / BACK PANELp.16Back Panelp.16CAUTIONp.16Sensor Filterp.16FILTER REPLACEMENT HEPA FILTER / DEODORIZING FILTERp.18LIFE OF FILTERSp.18UZ-HG6DF UZ-HG4DF UZ-HG4DFp.18UZ-HG6MF UZ-HG6MF UZ-HG6MFp.18How to install the Float and the Tray Panelp.18Tray Panelp.18UA-HG60Ep.18Humidifying Filterp.18UA-HG50E / UA-HG40Ep.18Floatp.18TROUBLESHOOTINGp.19SPECIFICATIONSp.20
Page 6 of the Sharp UA-HG40E user manual — CAUTIONS CONCERNING OPERATION
Page 6 · cliquer pour agrandir
Page 6

IMPORTANT SAFETY INSTRUCTIONS

Always follow basic safety precautions when using electrical appliances, including the following:

  • Only a Sharp Authorized Service Centre should service this air purifi er. Contact the nearest Service Centre for any problems, adjustments, or repairs.
  • Do not operate the unit in rooms where aerosol insecticides are present. Do not operate the unit in rooms where there is oily residue, incense, sparks from lit cigarettes, or chemical fumes in the air. Do not operate the unit in places where it may get wet, such as a bathroom.
  • Be cautious when cleaning the unit. Strong corrosive cleansers can damage the exterior.
  • When carrying the unit, fi rst remove the Water Tank and Humidifying Tray, and then hold the unit by the handles on both sides.
  • Do not drink the water in the Humidifying Tray or Water Tank.
  • Do not expose the unit to water. Doing so can cause a short circuit or electrical shock.
  • Replace the water in the Water Tank daily with fresh tap water, and regularly clean the Water Tank and Humidifying Tray (see E-8, E-13, E-14). When the unit is not in use, dispose of the water in the Water Tank and Humidifying Tray. Leaving water in the Water Tank or Humidifying Tray can cause mold, bacteria, and bad odours. In rare cases, such bacteria can be a health hazard.
  • Read all instructions before using the unit.
  • Use only a 220-240 volt outlet.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Centre or similarly qualifi ed persons in order to avoid a hazard.
  • Be sure to remove the power plug when refi lling the Water Tank, before performing maintenance, when removing and attaching and replacing the fi lter and when not using for a long time. Failure to do so can cause a short circuit resulting in electrical shock or fi re.
  • Do not use the unit if the power cord or plug is damaged or if the connection to the wall outlet is loose.
  • Periodically remove dust from the plug.
  • Do not insert fi ngers or foreign objects into the air intake or air outlet.
  • When removing the power plug, always hold the plug and never pull on the cord. Failure to do so can cause a short circuit resulting in electrical shock or fi re.
  • When removing the unit, do not damage the power cord with the casters. Failure to do so can cause electric shock, heat generation, or fi re.
  • Be careful not to damage the power cord, it may cause electric shock, excess heat or fi res.
  • Do not remove the plug when your hands are wet.
  • Do not place the unit near gas appliances or fi replaces.

If the air purifi er interferes with radio or television reception, try one or more of the following measures:

  • Adjust or reposition the receiving antenna.
  • Increase the distance between the unit and the radio or TV.
  • Connect the equipment into an outlet on a circuit different from that of the radio or TV receiver.
  • Consult the dealer or a qualifi ed radio or TV technician.

CAUTIONS CONCERNING OPERATION

  • Do not block the air intake or air outlet.
  • Do not place the unit near or on hot objects, such as stoves or heaters, or where it may come into contact with steam.
Page 7 of the Sharp UA-HG40E user manual — FILTER GUIDELINES
Page 7 · cliquer pour agrandir
Page 7
  • Always operate the unit in an upright position.
  • When moving the unit, use the handles on both sides. Do not move the unit when it is in operation.
  • If the unit is on easily damaged fl ooring, an uneven surface, or thick-piled carpet, lift it up when moving.
  • When moving the unit by its casters, move it slowly and in a horizontal direction.
  • Turn the unit off and remove the water tank before moving, take care not to catch your fi ngers.
  • Do not operate the unit without the fi lters, the Water Tank, and the Humidifying Tray properly installed.
  • Do not wash and reuse the HEPA fi lter and the Deodorizing fi lter. Doing so will not improve fi lter performance and can also cause electric shock or operating malfunctions.
  • Clean the exterior with a soft cloth only. Do not use volatile fl uids or detergents. The unit surface may be damaged or cracked with Benzene paint thinner or polishing powder. In addition, the sensors may malfunction as a result.
  • The frequency of descaling maintenance will depend on the hardness of and the impurities in the water that you use; the harder the water the more often descaling will be necessary.
  • Keep the unit away from water.
  • When refi lling the Water Tank, make sure of no water leaking from the Water Tank.
  • Be sure to wipe off any excess water on the outside of the Water Tank.
  • Do not use hot water (40 ºC or more), chemical agents, aromatic substances, dirty water, or other damaging substances. Doing so can deform the unit or cause it to malfunction.
  • Use only fresh tap water. Using other water sources risks the growth of molds, fungi, or bacteria.
  • Do not shake the Water Tank with holding the carrying handle.
  • Do not remove the Humidifying Filter from the fi lter frame except when replacing it.
  • Avoid spilling water when removing or cleaning the Humidifying Tray.
  • Do not remove the Float. If it comes off, refer to E-15.
  • Do not use the detergents for maintenance of the Humidifying Tray and Cover. If cause deformation, tarnishing, cracking (water leakage).
  • Do not scrub the Back Panel hard during its maintenance.

INSTALLATION GUIDELINES

  • Avoid locations where the sensors are exposed to direct wind. Doing so can cause the unit to malfunction.
  • Avoid locations where furniture, fabrics, or other objects can come in contact with the unit and interfere with the intake and outtake of air.
  • Avoid locations where the unit is exposed to condensation or drastic changes in temperature. Appropriate room temperature is between 0 – 35 ºC.
  • Place the unit on a level and stable surface with suffi cient air circulation. When placed on heavy carpet, the unit may vibrate slightly. Place the unit on a level surface to avoid water leakage from the Water Tank and Humidifying Tray.
  • Avoid locations that generate grease or oily smoke. Doing so can cause the unit exterior to crack and the sensors to malfunction.
  • The dust collecting ability of the unit is effective even when the unit is as close to 3 cm from the wall,the surrounding walls and fl oor may get dirty. Please place the unit at a distance from the wall. The wall directly behind the air outlet may become dirty over time. When using the unit for an extended period of time at the same location, periodically clean the walls adjacent to it.

FILTER GUIDELINES

  • Follow the instructions in this manual for proper fi lter care and maintenance. (Ref. E-13, E-14, E-15)
Page 8 of the Sharp UA-HG40E user manual — INSTALLATION GUIDELINES
Page 8 · cliquer pour agrandir
Page 8
Sharp UA-HG40E — INSTALLATION GUIDELINES diagram (page 8)
Fig. 3
5 6 1 20° 2 20° 3 7 1 Handle (2 Locations) 8 Sensor (Internal) 2 Temperature / Humidity / Odour* (*UA-HG60E / UA-HG50E) 3 Air Outlet (Front) 9 4 Caster Stopper (Right & Left) 5 Operation Panel 4 To Lock a caster stopper (Right & Left) 6 Front Louver (Adjustable) Locked Unlocked 7 Front Display Front 8 Unit 9 Caster (4 Locations) BACK Detection range 7 8 Light Sensor 9 Do not install the unit in the following places. 1 The Light Sensor may not sense correctly. 6 10 11 2 Directly under In shadow 12 a light fi xture. 3 Motion Sensor (UA-HG60E / UA-HG50E) 4 Sensory range is the area shown 13 5 below. Front 14 30° 1.6m (Plug shape varies by country.) 30° 1 Water Tank 7 Back Louver 2m 2 Tank Cap 8 Air Outlet (Back) Right and Left 2.3m 3 Humidifying Filter 9 Air Outlet LED(White) 4 Float 10 HEPA Filter 5 Humidifying Tray 11 Deodorizing Filter 2m 30° 30° 12 Back Panel (Pre-Filter) Dust(sensitive) Sensor / 6 13 Air Inlet Sensor Filter 14 Power Cord / Plug 1Water Tank7Back Louver 2Tank Cap8Air Outlet (Back) 3Humidifying Filter9Air Outlet LED(White) 4Float10HEPA Filter 5Humidifying Tray11Deodorizing Filter 6Dust(sensitive) Sensor / Sensor Filter12 13 14Back Panel (Pre-Filter) Air Inlet Power Cord / Plug
Page 9 of the Sharp UA-HG40E user manual — 7 6 5 3 2 1
Page 9 · cliquer pour agrandir
Page 9
Sharp UA-HG40E — INSTALLATION GUIDELINES diagram (page 9)
Fig. 4
1POWER ON / OFF Button7ON / OFF TIMER Button, Indicator Light (White) <Press 3 sec.> FILTER RESET Button 2INTELLIGENT MODE Button, Indicator Light (White) 3CLEAN ION SHOWER Button, Indicator Light (White)8DISPLAY SELECT Button <Press 3 sec.> CHILD-LOCK Button 4Plasmacluster Ion SPOT Button, Indicator Light (White) 9CHILD-LOCK Indicator Light (White) 5HUMIDIFY ON / OFF Button, Indicator Light (White)10FILTER RESET Indicator Light (Orange) 6MODE Button, Indicator Light (White)11Light Sensor

7 6 5 3 2 1

Sharp UA-HG40E — 7 6 5 3 2 1 diagram (page 9)
Fig. 5
1Humidity / Temperature Monitor Indicates the approximate humidity level or temperature in the room. The humidity setting cannot be adjusted. Humidity 20% to 90% is displayed. 20% 90% or or less more Temperature 0oC to 50oC is displayed. -1oC 50oC or or less more Wattage Monitor Indicates wattage by current operation. Timer Monitor Indicates setting time or remaining time of ON/OFF timer.4Patrolling Light (Green / Orange / Red) (Ref.E-9, E-10) 5Odour Light (White) (UA-HG60E / UA-HG50E) Indicates the Odour Sensor detects odours. 6Dust Light (White) Indicates the Dust(sensitive) Sensor detects usual dust. 7PM2.5 Light (White) Indicates the Dust(sensitive) Sensor detects microscopic dust. (particulate matter less than 2.5 microns) 8Motion Sensor (UA-HG60E / UA-HG50E) 2Plasmacluster Ion Light (Blue)9Cleanliness Monitor Indicates the air purity of the room in 7 levels with colour changes. Blue Red Clean Impure 3Humidify Light Green Humidity ON Off Humidity OFF Red(Flashing) Unit needs water
Page 10 of the Sharp UA-HG40E user manual — START STOP
Page 10 · cliquer pour agrandir
Page 10

PREPARATION

Always be sure to remove the power plug from the wall outlet.

FILTER INSTALLATION

Remove the Back Panel.

Install the fi lters in the correct order as shown.

Remove the plastic bag from the each fi lter.

Install the Back Panel.

HEPA Filter Deodorizing Filter

OPERATION

START/STOP

INTELLIGENT MODE (UA-HG60E / UA-HG50E)

The fan speed is automatically controlled depending on the 7 detection. (Ref. E-1)

START STOP

CLEAN ION SHOWER MODE AUTO MODE (UA-HG40E)

The unit releases Plasmacluster ions with strong airfl ow and collects dusts while decreasing static electricity for 10 min- utes. After that, the DUST sensor sensitivity is automatically set to ”HIGH”and quickly detects impurities and clean the air powerfully for 50 minutes.

The fan speed is automatically controlled depending on the 5 detection. (PM2.5 / Usual dust / Temperature /Humidity / Light)

  • When the operation fi nishes after 60 minutes, the unit will return to the prior operation mode. It is

able to change the other mode during this mode. • The Plasmacluster Ion can not be turned “OFF”. (Ref. E-10)

  • Front Display, Cleanliness Monitor and Air Outlet LED automatically switch ON and OFF based on room brightness. (When light control is set to "Auto". Ref. E-11)
Show 5 more labels / short text on this page
HEPA Filter · Tag · Back Panel · Deodorizing Filter · Click
Page 11 of the Sharp UA-HG40E user manual — ON CANCELLATION
Page 11 · cliquer pour agrandir
Page 11

PLASMACLUSTER ION SPOT MODE

HUMIDIFICATION SETTING

REFILLING THE WATER TANK

Use this mode when you want to remove adhering odour, germs, and other substances from cloths, sofas and curtains.

Remove the Water Tank.

Adjust Front Louver manually.

Fill the Water Tank with the tap water.

  • Emits highdensity Plasmacluster Ions only in the forward direction.
  • Discharges stronger air for 8 hours. When the operation fi nishes, the unit will return to its prior operation mode.
  • The Plasmacluster Ion can not be turned “OFF”. (Ref.E-10)

SELECTING MODE

To prevent leaks , securely tighten the Tank Cap.

Install the Water Tank.

SLEEP POLLEN MAX MED LOW

SLEEP The unit will operate quietly, and the fan speed is automati- cally switched depending on the amount of impurities in the air. The Front Display, Cleanliness Monitor and Air Outlet LED go off automatically. (When light control is set to "Auto". Ref.E-11)

ON OFF

POLLEN The DUST SENSOR sensitivity is automatically set to “HIGH” and quickly detects impurities such as dust and pollen and clean the air powerfully.

CHILD LOCK

When operating with Humidifi cation ON in the modes in the table below, the unit automatically controls humidity by sens- ing temperature and humidity. (Except MAX / MED / LOW mode.)

Operation of the operation panel will be locked.

ON CANCELLATION

TemperatureHumidity ALL MODE (Except MAX / MED / LOW SLEEP)SLEEP / MODE ~18 ºC65 %65 % 18 ºC~24 ºC60 %65 % 24 ºC~55 %60 %

more 3 sec.

more 3 sec.

Click

Page 12 of the Sharp UA-HG40E user manual — DRY AND LOW TEMPERATURE PATROLLING
Page 12 · cliquer pour agrandir
Page 12
Sharp UA-HG40E — PATROLLING FUNCTION diagram (page 12)
Fig. 6

Select the length of time you want. The unit automatically stops once the selected time is reached. Select the length of time you want. The unit automatically starts once the selected time is passes.

PATROLLING FUNCTION

The sensor detects a state requiring attention to room temperature and humidity during operation and tells it with Patrolling Light. Both "Dry and Low temperature patrolling" and "High temperature and High humidity patrolling" work. (This function informs a room condition. The unit cannot adjust temperature or lower humidity)

DRY AND LOW TEMPERATURE PATROLLING

It tells that the room is dry or the room temperature is low. When Patrolling Light turns to red, the unit operates with airfl ow a little stronger during Intelligent mode (Auto mode).

Patrolling LightIf the beeping sound is set to "ON". (Ref. E-12)Indoor environmentTemperature and humidity area (Figure below) Humidity / Temperature Monitor (for 30 seconds)Beeping sound Red"%" Light turns onBeep (once)Dry(3) "oC" Light fl ashingBeep (once)Low temperature Green(Normal)NoneNot dry or low temperature(1)·(2)

When the room is dry and the room temperature is low, viruses survive more easily. We recommend that you increase humidity with humidifi cation setting and temperature using heating appliances according to your room environment.

Material source: Dr. Makoto Shoji, Director of Shoji internal medicine and pediatrics clinic in Sendai City, Miyagi Prefecture, Japan

Right fi gureAbsolute humidity*1Virus environmentSurvival rate*2 (1)Over 11 gEnvironment which is less suitable for viruses to survive0 % to small percent (2)11 g or lessEnvironment where viruses can survive5 % (3)7 g or lessEnvironment which is suitable for viruses to survive20 %

*1 The absolute humidity is the total mass of water vapor present in 1 m3 of air regardless of temperature and is expressed in g. While humidity generally used for a weather forecast is called relative humidity, which is the ratio of the partial pressure of water vapor to the equilibrium vapor pressure of water at a given temperature and is expressed in %. Therefore, the absolute humidity is approximately 8 g at 15 oC and 18 g at 30 oC even at the same relative humidity of 60 %. *2 Survival rate of viruses emitted in air after 6 hours under each environment.

  • It does not notify of the existence of viruses themselves.
  • Patrolling Light's illuminating "Green" does not assure prevention of infection. Use it as a reference to make an environment to prevent infection during typical daily life.
  • While adjusting humidity to approximately 55 % to 65 % during operation in Intelligent mode (Auto mode), the unit controls humidifi cation, but does not make changes according to the virus' environment.
Show 7 more labels / short text on this page
· Temperature · · (oC) · · · Relative humidity (%)
Page 13 of the Sharp UA-HG40E user manual — A
Page 13 · cliquer pour agrandir
Page 13
Sharp UA-HG40E — HIGH TEMPERATURE AND HIGH HUMIDITY PATROLLING diagram (page 13)
Fig. 7

When the Plasmacluster function is ON, the Plasmacluster Ion light on the Front Display is on. (Ref.E-6)

The beeping sound of Patrolling Function is set to "Off" at the default. You can change it to "On" or "Cancel Patrolling Function". (Ref. E-11, E-12)

HIGH TEMPERATURE AND HIGH HUMIDITY PATROLLING

It tells high temperature and high humidity. When Patrolling Light turns to orange or red, the unit stops humidifi cation automatically. (However, it is in MAX/MED/LOW mode, it does not stop humidifi cation)

If the beeping sound is set to "ON". (Ref. E-12)

below) Humidity / Temperature Mon-

itor (for 30 seconds) Beeping sound

Red(Flashing) "oC" Light fl ashing Beep・・・(for 30 seconds) High temperature and high humidity

D

Red "oC" Light turns on Beep・・・(for 30 seconds) C

Relatively high temperature and high

Orange "oC" Light turns on None

B

Not high temperature nor

A

We recommend that you drink some water or lower the room temperature.

Guideline for preventing heatstroke in daily life

Overview of life activities to be noted Precautions

Elderly people are highly likely to suffer from heartstroke even in a resting state. Avoid going out and move to a cooler room.

Risks that could occur

C Heavy alert Avoid blazing sun when going out and pay attention to an increase of room temperature when staying in a room.

in all life activities

B Alert Risks that could occur in middle level or higher

Rest regularly when doing exercise or intense work.

A Caution Risks that could occur

Generally the risk is low, but people may suffer when doing hard exercise or hard work.

in hard life activities

This is not a function to prevent heatstroke. Please use this function as an assistance.

Show 19 more labels / short text on this page
Patrolling · Temperature and humidity · Light · Indoor environment · area (Figure · humidity · Green (Normal) None · high humidity · Temperature · Temperature · standard · ' · D Danger · & · % · (oC) · $ · life activities · Relative humidity (%)
Page 14 of the Sharp UA-HG40E user manual — Set
Page 14 · cliquer pour agrandir
Page 14

HOW TO CHANGE VARIOUS SETTINGS

You can change the functions in the "Type of setting" table in the following.

Sharp UA-HG40E — HOW TO CHANGE VARIOUS SETTINGS diagram (page 14)
Fig. 8

Select "Setting number" from the table in the following.

Forward

Reverse

Sharp UA-HG40E — Forward diagram (page 14)
Fig. 9 · Forward

Select "Function number" from the table in the following.

Set

UA-HG40E

Press Power button to fi nish the set- ting.

Sharp UA-HG40E — Set diagram (page 14)
Fig. 10 · Set

Auto (default) Light automatically switches ON or OFF based on room brightness.

Room is brightlight is ON Room is dark: light is OFF

You can select the brightness of the Front Display, Cleanliness Monitor and Air Outlet LED.

  • Turn off
  • When set to “Turn off”, the “Darker” light illuminates for 3 seconds after operation starts and then the light turns off.
  • The Humidity Light fl ashes darker only when the unit needs water.
  • Patrolling Light fl ashes/lights dimmer only when the room temperature or humidity requires attention.

Turn off

Page 15 of the Sharp UA-HG40E user manual — ON( notifi es with Patrolling Light only ) (default)
Page 15 · cliquer pour agrandir
Page 15

Function Setting

Sound Indicator Setting

Cancellation (default)

You can set the unit to make a beeping sound when the Water Tank is empty.

ON

Auto Restart

Cancellation

If the unit is unplugged or if there is a power failure, the unit will resume operation with the previous settings after power is restored.

ON (default)

Adjusting Sensor Sensitivity (F4-F7)

Light Sensor Low

Dust(sensitive) Sensor Standard (default)

Odour Sensor (UA-HG60E / UA-HG50E) High

ON( Standard sensing time ) (default)

Motion Sensor (UA-HG60E / UA-HG50E)

You can set the time until the Mo- tion Sensor detects that no one is in the room . You can also cancel Motion Sensor sensing.

ON( Longer sensing time )

Cancellation

ON(notifi es with Patrolling Light and sound) The beeping sound continues for 30 seconds at maximum. Pressing any button on the operation panel stops the sound. When Patrolling Light is red, the beeping sounds hourly.

Patrolling Function Setting

You can set the unit to make a beep- ing sound when Patrolling Light turn to red.You can also cancel Patrolling Function.

ON( notifi es with Patrolling Light only ) (default)

Cancellation

Page 16 of the Sharp UA-HG40E user manual — Sensor Filter
Page 16 · cliquer pour agrandir
Page 16

CARE AND MAINTENANCE

FILTER INDICATOR

WATER TANK

The fi lter reset Indicator light will turn on after approximately 720 hours operating. (30 days × 24 hours =720 hours)

Rinse the inside with water.

RESET

How to clean hard to remove dirt.

Clean the inside of the Water Tank with a soft sponge and the Tank Cap with a cotton swab or toothbrush.

more than 3 sec.

This is a reminder to perform the maintenance described be- low. After performing maintenance, reset the Filter Indicator.

CARE INDEX

UNIT / BACK PANEL

Wipe with a dry, soft cloth.

Sharp UA-HG40E — CARE INDEX diagram (page 16)
Fig. 11

Back Panel (Pre Filter)

Remove the dust gently with a cleaning tool such as a vac- uum cleaner.

How to clean hard to remove dirt.

Back Panel

1. Add a small amount of kitchen detergent to water and soak for about 10 minutes.

CAUTION

Place Ref.

Do not apply excessive pressure when scrubbing the back panel.

2. Rinse off the kitchen detergent with clean water. 3. Completely dry the fi lter in a well ventilated area.

E-13 2 Unit / Back Panel (Pre Filter)

Sensor Filter

1. Remove the Back Panel. 2. Remove the sensor fi lter. 3. If the sensor fi lter is very dirty, wash it with water and dry it thoroughly.
Show 10 more labels / short text on this page
Tank Cap · Toothbrush · Sensors · 1 Water Tank · 3 Sensors · 4 Humidifying Filter · E-14 Humidifying Tray · Sensor Filter · 5 HEPA Filter · E-15 Deodorizing Filter
Page 17 of the Sharp UA-HG40E user manual — CARE AND MAINTENANCE
Page 17 · cliquer pour agrandir
Page 17
Sharp UA-HG40E — CARE AND MAINTENANCE diagram (page 17)
Fig. 12

1 HOW TO REMOVE THE HUMIDIFYING FILTER AND TRAY.

Remove the Humidifying Tray Cover. Rinse with plenty of water.

If you remove the Humidifying Filter shaft, be sure to reattach it to its original position.

  • Do not remove the Float and the Tray Panel. If they come off, refer to E-15.

1 1. Fill the tray half-way with water. 2. Add a small amount of kitchen detergent.

3 Rinse off the kitchen detergent or the descaling solution with clean water.

Page 18 of the Sharp UA-HG40E user manual — UZ-HG6DF UZ-HG4DF UZ-HG4DF
Page 18 · cliquer pour agrandir
Page 18

FILTER REPLACEMENT HEPA FILTER / DEODORIZING FILTER

LIFE OF FILTERS

Remove the dust on the HEPA Filter and Deodorizing Filter.

Filter life varies depending on the room environment, usage conditions, and location of the unit. Lifespan of HEPA fi lter and Deodorizing fi lter and replacement suggestions are based on purifying a room in which 5 cigarettes are smoked per day and the unit's dust collection and deodorizing performance has declined to half the level of a new fi lter. We recommend replacing the fi lter more frequently if the unit is used in conditions signifi cantly more severe than a normal household.

HEPA FILTER

Maintain only the tagged surface. Do not clean up the opposite surface. The fi lter is fragile, so be careful not to apply too much pressure.

  • HEPA Filter About 10 years after opening
  • Deodorizing Filter About 10 years after opening
  • Humidifying Filter About 10 years after opening

DEODORIZING FILTER

Replacement Filter Model Consult your dealer when purchasing a replacement fi lter.

Both surfaces can be main- tained. The fi lter may be broken if being too much power is applied on it, so please handle it with care.

Filter UA-HG60E UA-HG50E UA-HG40E

(1 unit) UZ-HD6HF UZ-HD4HF UZ-HD4HF

Some odours absorbed by the fi lters will break down over time, causing additional odours. Depending on usage conditions, and especially if the unit is used in environments signifi cantly more severe than a normal household, these odours may become noticeable sooner than expected. Replace the fi lter in those cases or if dust is unable to be re- moved after maintenance.

UZ-HG6DF UZ-HG4DF UZ-HG4DF

UZ-HG6MF UZ-HG6MF UZ-HG6MF

How to install the Float and the Tray Panel

Tray Panel

UA-HG60E

Humidifying Filter

UA-HG50E / UA-HG40E

Float

*Do not dispose these parts.

1. Insert the fl oat under this tab.

Disposing of fi lters Dispose of used fi lters according to local laws and regulations.

HEPA Filter material:

  • Filter: Polypropylene
  • Frame: Polyethylene Deodorizing Filter material:
3. Insert the tab on the other side of the fl oat into the hole.
  • Filter: Paper
  • Frame: ABS resin Humidifying Filter material:
2. Insert the tab of the fl oat into the hole.
  • Filter: Rayon, polyester
Show 16 more labels / short text on this page
Tag · Replacement · HEPA Filter · Deodorizing · Filter (1 · unit) · Humidifying · Filter (1 · unit) · Shaft (white)* · Filter Frame (white)* · Filter Frame (gray)* · Shaft (gray)* · Tab · Float · Cross-Section view
Page 19 of the Sharp UA-HG40E user manual — TROUBLESHOOTING
Page 19 · cliquer pour agrandir
Page 19

TROUBLESHOOTING

Before contact for service, review the troubleshooting chart below to make sure that the problem is not a unit malfunction.

SYMPTOM REMEDY (the following are not due to a malfunction)

Odour and smoke persists. • Check the fi lters. If they appear to be extremely dirty, clean or replace them. (Ref. E-15)

The Cleanliness Monitor is blue even when the air is not clean.

  • The air may have been dirty when the unit was plugged in. Unplug the unit, wait one minute, and then plug the unit in again.

The Cleanliness Monitor light is red even when the air is clean.

  • Dirty or clogged dust(sensitive) sensor openings interfere with sensor operation. Gently clean the sensor fi lter or the back panel. (Ref. E-13).

The unit makes a clicking or ticking sound.

  • The unit may make clicking or ticking sounds when it is generating ions.

Air discharged from the unit has an odour.

  • Check to see if the fi lters are extremely dirty.
  • Clean or replace the fi lters. (Ref. E-13, E-14, E-15)
  • Use only fresh tap water. Using other water sources risks the growth of mold, fungi, or bacteria.

The unit does not operate when cigarette smoke is in the air.

  • Make sure the unit is installed in a location in which the sensors can detect cigarette smoke.
  • Check to see if the dust(sensitive) sensor openings are blocked or clogged. If they are blocked or clogged, clean the sensor fi lter or the back panel. (Ref. E-13)

The FILTER RESET Indicator Light is on.

  • Whenever after performing maintenance or replacing the fi lters, connect the power cord to an outlet and then press the Filter Reset Button. (Ref. E-13)

The Front Display is turned off. • When Light control is set to "Auto", the light automatically turns off when the room is dark. Moreover, when Light control is set to "Turn off", the light is always off. If you do not want the light to be off, set Light control to the "Darker" setting. (Ref. E-11)

The Humidify Light on the Front Display does not light up when the tank is empty.

  • The room has reached the appropriate level of humidity and has stopped humidifying.
  • Check the styrofoam fl oat for impurities. Clean the Humidifying Tray. Make sure that the unit is on a level surface. (Ref. E-14)

The water level in the tank does not decrease or decreas- es slowly.

  • Check to see if the Humidifying Tray and Water Tank are correctly installed. Check the Humidifying Filter. (Ref. E-14)
  • If the fi lter is extremely dirty, clean or replace it. (Ref. E-15)

The Cleanliness Monitor changes colour frequently.

  • The Cleanliness Monitor automatically changes colour when the dust (sensitive) sensor and odour sensor* detect impurities. If you are concerned about the change, you can change sensor sensitivity. (Ref. E-11,E-12) (*UA-HG60E / UA-HG50E)

There is a discrepancy between the unit’s Humidity Monitor and another hygrometer in the room.

  • There is a difference in the humidity level within the same room.
  • The sensor have different measurement parameters.
  • If the monitor indicates wattage or temperature, switch the display by pressing the DISPLAY SELECT button. (Ref. E-10)

The unit PM2.5 Light does not match weather report or other local PM2.5 data.

  • Outdoor and indoor as well as the home environment (the volume of traffi c nearby, number of stories in home, etc.) may cause a reading different than local PM2.5 data.
  • " o C" Light fl ashing
  • The room is suitable for viruses to survive due to low room temperature. We recommend you adjust the temperature using heating appliances. (Ref. E-9)
  • The room temperature and humidity is high. We recommend that you drink some water or lower the room temperature. (Ref. E-10)

ERROR DISPLAY If error occurs repeatedly, contact the Sharp Service Centre.

Sharp UA-HG40E — TROUBLESHOOTING diagram (page 19)
Fig. 13

Make sure that the Humidifying Filter and Humidifying Tray are properly installed, and then turn the power to ON again.

Unplug the unit, wait one minute, and then plug the unit in again.

Page 20 of the Sharp UA-HG40E user manual — & HUMIDIFY
Page 20 · cliquer pour agrandir
Page 20

SPECIFICATIONS

Model UA-HG60E UA-HG50E UA-HG40E

Power supply 220-240 V 50-60 Hz

Fan Speed Adjustment MAX MED LOW MAX MED LOW MAX MED LOW

Fan Speed (m3/hour) 408 240 72 306 180 60 240 120 60

CLEAN

Rated Power (W) 72 38 5.0 53 26 5.0 31 12 5.0

AIR

Noise Level (dBA) 53 48 24 52 47 19 46 40 19

Fan Speed (m3/hour) 342 240 72 240 120 60 210 120 60

CLEAN AIR

Rated Power (W) 55 40 6.5 33 14 6.5 24 14 6.5

& HUMIDIFY

Noise Level (dBA) 49 48 24 46 40 20 43 40 20 Humidifi cation

(mL/hour) *1 630 470 200 450 300 150 400 300 150

Recommended Room Size (m2) *2 ~50 ~38 ~28 High density Plasmacluster ion recommended room size (m2) *3 ~35 ~28 ~21

Water Tank Capacity (L) 3.0 2.5 2.5

Sensors Dust(sensitive) / Odour / Light / Temperature & Humidity / Motion

Dust(sensitive) / Light / Temperature & Humidity

Cord Length (m) 2.0

Dimensions (mm) 370 (W) × 293 (D) × 660 (H) 345 (W) × 262 (D) × 631 (H) 345 (W) × 262 (D) × 631 (H)

Weight (kg) 10.5 9.2 9.2

  • *1
  • The amount of humidifi cation changes in accordance with indoor and outdoor temperature and humidity. The amount of humidifi cation increases as temperatures rises or humidity decreases. The amount of humidifi cation decreases as temperatures decrease or humidity rises.
  • Measurement Conditions: 20 ºC, 30 % humidity (JEM1426) *2
  • The recommended room size is appropriate for operating the unit of maximum fan speed.
  • The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes. *3
  • Room size in which approximately 7000 ions per cubic centimeter can be measured in the centre of the room when the unit is placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the fl oor.
Sharp UA-HG40E — & HUMIDIFY diagram (page 20)
Fig. 14

When the unit’s power plug is inserted in a wall outlet it consumes about 1.2 watts of standby power in order to operate electrical circuits. To conserve energy, unplug the power cord when the unit is not in use.

Page 21 of the Sharp UA-HG40E user manual — SPECIFICATIONS
Page 21 · cliquer pour agrandir
Page 21

A. Information on Disposal for Users (private households)

1. In the European Union

IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE! Used electrical and electronic equipment should always be collected and treated SEPARATELY in accordance with local law. Separate collection promotes an environment-friendly treatment, recycling of materials, and min- imizing fi nal disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available. If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal. ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES; FOR IN- STANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law. The symbol shown above appears on electrical and electronic equipment (or the packaging) to remind the users of this. Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equip- ment. Return is free of charge. If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.

2. In other Countries outside the EU

If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.

For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch

B. Information on Disposal for Business Users.

1. In the European Union

If the product is used for business purposes and you want to discard it:

Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.

For Spain: Please contact the established collection system or your local authority for take-back of your used products.

2. In other Countries outside the EU

If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.

Page 22 of the Sharp UA-HG40E user manual — SPECIFICATIONS
Page 22 · cliquer pour agrandir
Page 22
Page 22 of the Sharp UA-HG40E user manual — SPECIFICATIONS
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Odour and smoke persists.• C heck the fi lters. If they appear to be extremely dirty, clean or replace them. (Ref. E-15) p.19
The Cleanliness Monitor is blue even when the air is not clean.• The air may have been dirty when the unit was plugged in. Unplug the unit, wait one minute, and then plug the unit in again. p.19
The Cleanliness Monitor light is red even when the air is clean.• Dirty or clogged dust(sensitive) sensor openings interfere with sensor operation. Gently clean the sensor fi lter or the back panel. (Ref. E-13). p.19
The unit makes a clicking or ticking sound.• The unit may make clicking or ticking sounds when it is generating ions. p.19
Air discharged from the unit has an odour.• Check to see if the fi lters are extremely dirty. • Clean or replace the fi lters. (Ref. E-13, E-14, E-15) • Use only fresh tap water. Using other water sources risks the growth of mold, fungi, or bacteria. p.19
The unit does not operate when cigarette smoke is in the air.• Make sure the unit is installed in a location in which the sensors can detect cig- arette smoke. • Check to see if the dust(sensitive) sensor openings are blocked or clogged. If they are blocked or clogged, clean the sensor fi lter or the back panel. (Ref. E-13) p.19
The FILTER RESET Indicator Light is on.• Whenever after performing maintenance or replacing the fi lters, connect the power cord to an outlet and then press the Filter Reset Button. (Ref. E-13) p.19
The Front Display is turned off.• When Light control is set to "Auto", the light automatically turns off when the room is dark. Moreover, when Light control is set to "Turn off", the light is always off. If you do not want the light to be off, set Light control to the "Darker" setting. (Ref. E-11) p.19
The Humidify Light on the Front Display does not light up when the tank is empty.• The room has reached the appropriate level of humidity and has stopped hu- midifying. • Check the styrofoam fl oat for impurities. Clean the Humidifying Tray. Make sure that the unit is on a level surface. (Ref. E-14) p.19
The water level in the tank does not decrease or decreas- es slowly.• Check to see if the Humidifying Tray and Water Tank are correctly installed. Check the Humidifying Filter. (Ref. E-14) • If the fi lter is extremely dirty, clean or replace it. (Ref. E-15) p.19
The Cleanliness Monitor changes colour frequently.• The Cleanliness Monitor automatically changes colour when the dust (sensitive) sensor and odour sensor* detect impurities. If you are concerned about the change, you can change sensor sensitivity. (Ref. E-11,E-12) (*UA-HG60E / UA-HG50E) p.19
There is a discrepancy between the unit’s Humidity Monitor and another hygrometer in the room.• There is a difference in the humidity level within the same room. • The sensor have different measurement parameters. • If the monitor indicates wattage or temperature, switch the display by pressing the DISPLAY SELECT button. (Ref. E-10) p.19
The unit PM2.5 Light does not match weather report or other local PM2.5 data.• Outdoor and indoor as well as the home environment (the volume of traffi c near- by, number of stories in home, etc.) may cause a reading different than local PM2.5 data. p.19
"oC" Light fl ashing• The room is suitable for viruses to survive due to low room temperature. We recommend you adjust the temperature using heating appliances. (Ref. E-9) • The room temperature and humidity is high. We recommend that you drink some water or lower the room temperature. (Ref. E-10) p.19

Poser une question sur : Sharp UA-HG40E

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Sharp UA-HG40E

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Sharp UA-HG40E manuel PDF

144 pages·6.9 MB·Purificateur d'air·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…