UA-HD60E, UA-HD50E, UA-HD40E
EN ES DE PT FR PL NL



UA-HD60E UA-HD50E UA-HD40E
AIR PURIFIER with Humidifying Function OPERATION MANUAL
“Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Cor- poration.

* The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm3, which is measured around the center of a room with the “high-density Plasmacluster 7000” applicable fl oor area (at 1.2 m height above the floor) at the medium wind volume in humidifying & air purifying mode, or in air purifying mode, when a humidifi er/air purifi er or an air purifier using the high-density Plasmacluster ion evolving device is placed close to a wall. This product is equipped with a device corresponding to this capacity.
Free standing type

The air purifi er draws in room air from the air intake, passes the air through a Pre- Filter, a Deodorizing Filter and a HEPA Filter inside of the unit, then discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the fi lter and also helps absorb odours. The Deodorizing Filter gradually absorbs odours as they pass through the fi lter.
Some odours absorbed by the fi lters may break down over time, resulting in additional odour. Depending on the usage environment, especially when the product is used in extreme environments (significantly more severe than normal household use), this odour may become strong in a shorter period than expected. If the odour persists, the fi lters should be replaced.

(Common illustration has used “UA-HD60E”.)

Unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster + Humidifi cation
TRAPS DUST* Pre-Filter traps dust and other large airborne particles. DECREASES ODOURS Deodorizing Filter absorbs many common household odours.
REDUCES POLLEN & MOLD* HEPA Filter traps 99.97% of particles as small as 0.3 microns.
FRESHENS Plasmacluster treats the air similar to the way nature cleans the environment by emitting a balance of positive and negative ions.
*When air is drawn through the filter system.
Sensor Technology continuously monitors air quality, and automatically adjusting operation based on detected air purity and humidity.
Thank you for purchasing this SHARP Air Purifier. Please read this manual carefully before using the air purifi er. After reading, keep the manual in a convenient location for future reference.

When using electrical appliances, basic safety precautions should be followed, including the following:

If this air purifi er should cause interference to radio or television reception, try to correct the interference by one or more of the following measures:

from the wall, but place it as far as possible because it may dirty the wall or fl oor around.


1 Air Outlet (Front) 2 Operation panel (Ref. E-6) 3 Display (Ref. E-6) 4 Main Unit 5 Stopper (2 Locations) 6 Caster (4 Locations)

(Plug shape varies by country.)


3 2 4 5 1 6



Humidity Monitor Indicates approximate humidity level in the room. Humidity setting cannot be adjusted.
Dust / Odour Monitor* The dust / Odour monitor detects dust in the room and indicates the intensity in 5 levels with colour changes.

Be sure to remove the power plug from the wall outlet.

Remove the Back Panel.
Remove the fi lters from the plastic bag.
Install the fi lters in the correct order as shown.
Install the Back Panel.
Fill in the usage start date on the Date Label.

Be sure to remove the power plug from the wall outlet.

When using the Clean Air Humidify Mode, or the Clean Ion Shower Mode.
Remove the Water Tank by pushing the handle down and pulling it forward.
Fill the Water Tank with tap Water.

Using to quickly clean the air, reduce odours and to humidify.
STOP
About Automatic Humidify Mode The Temperature/Humidity sensors automatically detect and adjust humidity according to changes in room temperature. Depending on the size and humidity of the room, humidity may not reach 55~65 %. In such cases, it is recommended that CLEAN AIR HUMIDIFY/ MAX MODE be used.
Temperature Humidity ~18 ºC 65 % 18 ºC~24 ºC 60 % 24 ºC~ 55 %
Using when additional humidity is not required.

Releases high-density Plasmacluster ions and discharges strong air fl ow for 60 minutes.

Select the desired fan speed.

AUTO The fan speed is automatically switched (between HIGH and LOW) depending on the amount of impurities in the air. The sensors detect impurities for effi cient air purifi cation.
The unit will automatically operate at higher level than the normal with the intensities of releasing high-density Plasmacluster ions and catching dust. When humidity reaches at 70% or more, the unit discharges strong air fl ow continuously.
POLLEN DUST SENSOR sensitivity is automatically set to “HIGH” and quickly detects impurities such as dust and pollen to clean the air.
OFF
ON

When Plasmacluster ion is OFF, the Plasmacluster Ion Light (blue) is turned off .

more than 3 sec.
more than 3 sec.
Operation of the unit display will be locked. It is the same method as starting operation.
more than 3 sec.
more than 3 sec.
(In operation)

Use this function to select the desired brightness.
Select the length of time you want. The unit automatically starts once the selected time is reached.
(with the unit OFF)
Select the length of time you want, with the unit on. The unit automatically stops once the selected time is reached.

DUST/ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high” if the DUST/ ODOUR MONITOR is constantly green to increase sensitivity. *Odour sensor is only equipped with UA-HD60E and UA-HD50E.
more than 3 sec.
(with the unit OFF)


In case operating at the “MEDIUM” wind volume, the Indicator Light will turn on after approximately 720 hours. (30days×24hours=720) (The lighting time will vary between approximately 360-1080 hours depending on the wind volume.)
Reminder to perform maintenance of parts below. After performing maintenance, reset the Filter Indicator. (Ref. E-13)
more than 3 sec.

After maintenance, replace the parts accurately.


③ ①

Be sure to remove the power plug from the wall outlet.
Rinse the inside with a small amount of water.

Clean inside of the water tank with a soft sponge and the tank cap with a cotton swab or a toothbrush.
Rinse with plenty of water.


Rinse the inside of the Humidifying Tray with a toothbrush.

TRAY 1. Fill the tray half way with water.
Gently remove dust with a vacuum cleaner attachment or similar tool.

Sensor

Be sure to remove the power plug from the wall outlet.
Remove the dust on the HEPA FILTER and DEODORIZING FILTER.
Do not WASH in water and DRY in the sun.
Wipe with a dry, soft cloth.
surface. • Do not use detergents Detergent ingredients may damage the unit.
Tag · HEPA Filter (White) · Deodorizing Filter (Black)

Be sure to remove the power plug from the wall outlet.
Replacement timing Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odour persists, replace the fi lter. (Refer to “Please read before operating your new Air Purifi er”) The following filter life and replacement period is based on the condition of smoking 5 cigarettes per day and the dust collection/deodorization power is reduced by half compared with that of new fi lter. We recommend to replace the filter more frequently if the product is used in a condition significantly severer than normal household use.
Please consult your dealer for purchase of replacement filter.


Use the date label as a reminder for next replacement.
Disposal of Filters
Please dispose of used fi lters according to any local laws and regulations.

HEPA Filter material :
Deodorizing Filter material :
Humidifying Filter material :
Filter Frame (white)

Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction.
SYMPTOM REMEDY (not a malfunction)
Odours and smoke are not removed.
The Dust/Odour Monitor illuminates green even when the air is impure.
The Dust/Odour Monitor illumi- nates orange or red even when the air is clean.
A clicking or ticking sound is heard from the unit.
The discharged air has an odour.
The unit does not operate when cigarette smoke is in the air.
Filter Indicator Light is illuminated.
The Dust/Odour Monitor are turned off .
The Water Supply Indicator Light does not illuminate when the tank is empty.
Water lever in the tank does not decrease or decreases slowly.
The Dust/Odour Monitor lights change colour frequently.


When the Roller / Float / Tray partition was removed.
Fix the roller in the tray from side way.
After a power failure, automatically resume the operation when the power recovers. Auto Restart can be set. • Even when the plug is unplugged or the breaker is thrown during the operation, the operation resumes at the previous operation mode and settings if the power recovers.
If the , , lamp lights up for 10 seconds, the setting is complete.

ERROR DISPLAY If error occurs again, contact the Sharp Service Centre.
Abnormal Humidity Filter.
Verify if the Humidifying Filter, Humidifying Tray and Roller are properly installed and then turn power ON again.
Abnormal fan motor.
Unplug the unit, wait one minute, and plug the unit in again. Abnormal temperature- humidity sensor.

Dimensions (mm) 420 (W) × 242 (D) × 637 (H) 399 (W) × 230 (D) × 615 (H) 399 (W) × 230 (D) × 615 (H)
Fan Speed Adjustment MAX MED LOW MAX MED LOW MAX MED LOW
Humidifi cation (mL/hour)*1 660 480 230 600 460 190 440 370 190
Sensors Dust/Odour/Temperature & Humidity Dust/Odour/Temperature & Humidity Dust/Temperature & Humidity
Fan Speed (m3/hour) 396 240 90 306 186 60 216 144 60
Rated Power (W) 80 24 5.5 54 17 5 25 12 5
Noise Level (dBA) 55 45 25 55 43 23 47 37 23
Fan Speed (m3/hour) 366 240 90 288 186 60 180 144 60
Rated Power (W) 70 26 7 49 20 7 19 14 7
Noise Level (dBA) 54 45 25 54 43 23 43 37 23
Model UA-HD60E UA-HD50E UA-HD40E
Recommended Room Size (m2)*2 ~48 ~38 ~26
High density Plasmacluster ion recommended room size (m2)*3 ~35 ~28 ~21
Water Tank Capacity (L) 3.0 2.5 2.5
Weight (kg) 8.6 7.9 7.9
Filter type Dust collection HEPA with Microbial control *4
Power supply 220-240 V 50-60 Hz

Cord Length (m) 2.0
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this
*1 • Humidifi cation Amount changes in accordance with indoor and outdoor temperature and humidity. Humidifi cation Amount increases as temperatures rise or humidity decreases.
Humidifi cation Amount decreases as temperatures decrease or humidity rises.
For energy conservation, unplug the power cord when the unit is not in use.
*4 • The fi lter removes more than 99.97% of particles of 0.3-micron dust. (JEM1467)
CLEAN AIR
CLEAN AIR
Deodorization Deodorizing

A. Information on Disposal for Users (private households)
IF YOU WISH TO DISPOSE OF THIS EQUIPMENT, DO NOT USE THE ORDINARY WASTE BIN, AND DO NOT PUT THEM INTO A FIREPLACE! Used electrical and electronic equipment should always be collected and treated SEPA- RATELY in accordance with local law. Separate collection promotes an environment-friendly treatment, recycling of materials, and minimizing fi nal disposal of waste. IMPROPER DISPOSAL can be harmful to human health and the environment due to certain substances! Take USED EQUIPMENT to a local, usually municipal, collection facility, where available. If in doubt about disposal, contact your local authorities or dealer and ask for the correct method of disposal. ONLY FOR USERS IN THE EUROPEAN UNION, AND SOME OTHER COUNTRIES; FOR INSTANCE NORWAY AND SWITZERLAND: Your participation in separate collection is requested by law. The symbol shown above appears on electrical and electronic equipment (or the packag- ing) to remind the users of this. Users from PRIVATE HOUSEHOLDS are requested to use existing return facilities for used equipment. Return is free of charge. If the equipment has been used for BUSINESS PURPOSES, please contact your SHARP dealer who will inform you about take-back. You might be charged for the costs arising from take-back. Small equipment (and small quantities) might be taken back by your local collection facility. For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch
B. Information on Disposal for Business Users.
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.


Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Odours and smoke are not removed. | • Clean or replace the fi lters if they appear to be heavily soiled. (Ref. E-12,E-13,E-15) | p.21 | |
| The Dust/Odour Monitor illuminates green even when the air is impure. | • The air could be impure at the time the unit was plugged in. Unplug the unit, wait one minute, and plug the unit in again. | p.21 | |
| The Dust/Odour Monitor illumi- nates orange or red even when the air is clean. | • Sensor operation is aff ected if the dust sensor openings are dirty or clogged. Gently clean the dust sensors. (Ref. E-5). | p.21 | |
| A clicking or ticking sound is heard from the unit. | • Clicking or ticking sounds may be audible when the unit is generating ions. | p.21 | |
| The discharged air has an odour. | • Check to see if the fi lters are heavily soiled. • Clean or replace the fi lters. • Plasmacluster Air Purifi ers emit small traces of ozone which may produce an odour. | p.21 | |
| The unit does not operate when cigarette smoke is in the air. | • Is the unit installed in a location that is diffi cult for the sensor to detect cigarette smoke? • Are the dust sensor openings blocked or clogged? (In this case, clean the openings.) (Ref. E-5) | p.21 | |
| Filter Indicator Light is illuminated. | • A fter replacing fi lters, connect the power cord to an outlet and press the Filter Reset Button. (Ref. E-12) | p.21 | |
| The Dust/Odour Monitor are turned off . | • Check to see if the Lights OFF Mode selected. If so, then press the Lights Control Button to activate the indicator lights. (Ref. E-11) | p.21 | |
| The Water Supply Indicator Light does not illuminate when the tank is empty. | • Check Styrofoam fl oat for impurities. Clean the HumidifyingTray. Ensure unit is located on a level surface. | p.21 | |
| Water lever in the tank does not decrease or decreases slowly. | • Check to see if the Humidifying Tray and Water Tank are correctly installed. Check the Humidifying Filter. • Clean or replace the fi lter when it is heavily soiled. (Ref. E-15 and E-16). | p.21 | |
| The Dust/Odour Monitor lights change colour frequently. | • The Dust/Odour Monitor lights automatically change colours as impurities are detected by the dust sensor and odour sensor. | p.21 | |
| When the Roller / Float / Tray partition was removed. FLOAT Fl 1. Insert the fl oat under this tab. 2. Inner the tab of fl oat into the hole. Tab 3. Insert the tab on the other side of the fl oat into the hole. Cross-Section | • I nstall the Roller / Float / Tray partition in order below. Tray partition Click Humidifying tray ROLLER Fix the roller in the tray from side way. oat Float view | p.22 | |
| AUTO RESTART After a power failure, automatically resume the operation when the power recovers. ON (with the unit OFF) (simultaneously for more than 3 sec.) If the , , for 10 second complete. | Auto Restart can be set. • E ven when the plug is unplugged or the breaker is thrown during the operation, the operation resumes at the previous operation mode and settings if the power recovers. CANCELLATION (with the unit OFF) (simultaneously for more than 3 sec.) lamp lights up s, the setting is | p.22 |
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.