Page 1 of the Pulsar Apex XD38 user manual — THERMAL S I G H T S
Page 1 · cliquer pour agrandir
Page 1
Pulsar Apex XD38 — THERMAL S I G H T S diagram (page 1)
Fig. 1

I N S T R U C T I O N S A P E X

THERMAL S I G H T S

Page 2 of the Pulsar Apex XD38 user manual — THERMAL S I G H T S
Page 2 · cliquer pour agrandir
Page 2
THERMAL SIGHTS APEX VISEURS THERMIQUES APEX WÄRMEBILD-ZIELFERNROHR APEX VISORES TÉRMICOS APEX CANNOCCHIALI TERMICI APEX ТЕПЛОВИЗИОННЫЙ ПРИЦЕЛ APEX2–17 18–35 36–53 54–71 72–89 90–107

¡Atención! La exportación de los modelos 76415/76425/76475 con una frecuencia de 50 Hz puede tener restricciones de exportación según la ley en su región.

Внимание! Экспорт моделей 76415/76425/76475 с частотой 50 Гц может иметь экспортные ограничения в зависимости от законодательства Вашего региона.

Page 3 of the Pulsar Apex XD38 user manual — THERMAL S I G H T S
Page 3 · cliquer pour agrandir
Page 3
Pulsar Apex XD38 — THERMAL S I G H T S diagram (page 3)
Fig. 2
Pulsar Apex XD38 — THERMAL S I G H T S diagram (page 3)
Fig. 3
Page 4 of the Pulsar Apex XD38 user manual — CONTROLS
Page 4 · cliquer pour agrandir
Page 4

џ Video output enabling recording џ Defective pixel repair option џ Extra Weaver rail for accessories џ Wireless remote control џ Wide range of display brightness and contrast adjustment with memorization

Pulsar Apex XD38 — COMPONENTS AND CONTROLS diagram (page 4)
Fig. 4

of user settings џ Display off function – protects against decamouflage and quick power on for

COMPONENTS AND CONTROLS

1. Sight power on button “ON” 2. Calibration button “Cal” 3. Extra modes button “MODE” 4. Battery compartment knob 5. Eyepiece adjustment ring 6. Ring for lens internal focusing 7. Objective lens 8. Lens cap 9. Controller 10. Video jack / External power supply jack 11. Extra Weaver rail 12. Mount

Video cable / External power supply cable: 13. Sight connecting plug 14. Video output jack 15. External power supply jack

Remote control: 16. Taste “ON” (switch on/off the sight) 17. Taste “Cal” (calibration) 18. Taste “ZOOM/ PiP” (Digital zoom/ Mode “PiP”).

CONTROLS

Sight power on button - “ON”: Short press – power on the sight. Long press – power off the sight. Short press when the sight is on – power off the display (“Display off” message on the display”). Subsequent short press – power on the display. Sight calibration button (“Cal”): Short press – sight calibration (operates in any calibration mode).

Extra modes button “MODE”: Short press – activation of digital zoom or function “PiP” (“picture in picture”)(if PiP is activated) Long press – activation/deactivation of the mode “Inversion”

immediate use

Page 5 of the Pulsar Apex XD38 user manual — BATTERY INSTALLATION
Page 5 · cliquer pour agrandir
Page 5

6 Controller: Rotation (by default) – display brightness adjustment Short press – switching between brightness and contrast adjustment modes, gradual digital zoom. Rotation (followed by a short press) – display contrast adjustment Rotation (followed by a short press) – continuous digital zoom (from 1x to 2x with 0.1x increment) Long press – entering the menu.

GUIDELINES FOR OPERATION

The sight has been designed for long-term use. To ensure sustainable performance, please adhere to the following: џ Before use make sure that you have installed and fixed the mount

according to the instructions of the section “Installation of mount” (section 9 “Operation”). џ Store with the lens cap on in the carrying case. џ Switch off the scope after use. џ Attempts to disassemble or repair the scope will void the warranty! џ Clean the scope's optical surfaces only if necessary, and use caution. First,

MENU/STATUS BAR ICONS

remove (by blowing with a blower brush or canned air) any dust or sand particles. Then proceed to clean by using camera/lens cleaning equipment approved for use with multicoated lenses. Do not pour the solution directly onto the lens! џ The sight can be used in various operating temperatures. However, if it has

been brought indoors from cold temperatures, do not turn it on for 2 to 3 hours. This will prevent external optical surfaces from fogging. џ If the sight is unable to mount onto the rifle securely, or you have doubts

about the mounting system, see a qualified gunsmith. Using the weapon with a poorly mounted scope can lead to inaccurate target shooting! џ To ensure reliable performance, it is recommended to carry out regular

PAL/NTSC video output signal selection / disable

technical inspections of the unit. џ Do not leave batteries in the unit if it is not going to be used for an extended

Brightness control of onscreen symbols

period. џ Batteries shall not be exposed to excessive heat such as sunshine, fire or

2x continuous digital zoom

Defective pixel repair option

the like. WARNING! Do not point the objective lens of the unit at bright sources of light such as the sun. This may disable electronic components of the unit. The warranty does not cover damage caused by improper operation.

Cross for defective pixel repair

Display brightness and contrast adjustment

Image inversion mode“White hot”/“Black hot”

Return to default settings

BATTERY INSTALLATION

џ Turn the battery compartment knob (4) counterclockwise to the “Open”

Operation on external power supply

position and remove it. џ Install two CR123A batteries (or rechargeable batteries) according to the

marking on the battery compartment cover and inside it. џ Turn the battery compartment knob (4) clockwise – the latch will pull out

Please refer to section 11 “Main menu” for other icons.

(see the drawing). џ Replace the battery cover and press it until its clicking position - the cover

will close. џ Battery charge level is displayed on the status bar ( ) . џ In case of complete battery discharge, icon is flashing on the status bar and in the centre of the display. Note: to ensure long and reliable operation it is recommended that you use quality rechargeable batteries 16340 (CR123A) with a capacity of at least 800 mAh. Please do not use batteries of different types or batteries with various charge levels.

Show 8 more labels / short text on this page
Operation mode “Rocks“ · Operation mode “Forest” · Operation mode “Identification” · Manual calibration · Semiautomatic calibration · Automatic calibration · Clock setup · Low battery indicator
Page 6 of the Pulsar Apex XD38 user manual — OPERATION
Page 6 · cliquer pour agrandir
Page 6

8 Manual (silent) calibration mode џ The lens cap (8) should be closed. џ Power on the sight with the “ON” (1) button, hold down the controller (9) for

EXTERNAL POWER SUPPLY

two seconds to enter the menu. џ Rotate the controller to select option Cal. Press the controller. џ Rotate the controller to select mode М. Press the controller to confirm. To

The sight can be powered with an external DC power supply (2.1mm pin) with stabilized voltage ranging from 8V to 15V or a 12V vehicle socket. џ Connect the plug (13) of the cable to the jack (10) of the sight by matching

exit the menu, press and hold the controller (9) for two seconds or wait 10 seconds for automatic exit. џ Press the CAL (2) button to calibrate. The image will freeze for 1-2

the notch in the plug connector and the protrusion of the jack (10) (see the scheme). џ Secure the cable by turning clockwise the locking ring of the plug (13). џ Connect the external power supply (AC/DC) or car adapter to the jack (15)

seconds. Then open the lens cap. Calibration is completed. џ In case you see image flaws (such as frozen image, vertical stripes etc.) re-

of the cable. Note: central pin of the power supply that you connect to the “power” jack of the sight, must have marking “+”. џ The power supply may have marking . џ Connection of an external power supply (icon on the status bar) automatically cuts off power supply from batteries. џ External power supply DOES NOT charge the batteries in the sight! Attention! We suggest that you use battery packs EPS3 or EPS5 ensuring from 9 to 20 hours of continuous operation.

calibrate the unit with the lens cap closed.

Semiautomatic calibration mode џ Power on the unit, open the lens cap. џ Hold down the controller (9) for two seconds to enter the menu. џ Rotate the controller to select option Cal. Press the controller. џ Rotate the controller to select mode H. Press the controller to confirm. џ Press the CAL (2) button to calibrate. The image will freeze for 1-2 seconds

and you will hear the sound of the internal shutter. Calibration is completed.

Automatic calibration mode With the automatic calibration mode the thermal imager calibrates by itself according to the software algorythm. The detector (microbolometer) is closed with the shutter automatically. User assisted calibration with the CAL (2) button is allowed in this mode. џ Power on the unit, open the lens cap. џ Hold down the controller (9) for two seconds to enter the menu. џ Rotate the controller to select option Cal. Press the controller. џ Rotate the controller to select mode A. Press the controller to confirm. џ At the moment of the automatic calibration the image will freeze for 1-2

OPERATION

Installation of mount Before using the sight you need to install the mount (12). The sight can be used with various mount types such as Weaver, Euro- prism, Los, Side mount, MAK adapter etc. that allow the scope to be installed on different types of rifles. The mounting holes in the base of the sight enable the mount to be installed in one of the multiple positions. The choice of the mounting position helps the user to ensure the correct eye relief depending on the rifle type. џ Attach the mount to the base of the sight using a hex-nut wrench and

seconds and you will hear the sound of the internal shutter. џ Time intervals between calibrations depend on the heat of the detector.

screws (see installation scheme). џ Install the scope on the rifle and check if the position is suitable for you. џ If you are happy with its position, remove the scope, unscrew the screws

The unit may require calibration more frequently on activation.

Focusing and image adjustment џ Open the lens cap (8). џ Adjust sharp image of the display icons by turning the eyepiece ring (5). џ To adjust display brightness, rotate the controller (9). Brightness level

halfway, apply some thread sealant onto the thread of the screws and tighten them fully (do not overtighten). Let the sealant dry for a while. џ The sight is ready to be installed on a rifle and to be zeroed. џ After first installation of your sight on a rifle, please follow instructions in the

section “Zeroing”. Note. Please check that your sight is duly zeroed after changing a mount.

(from 0 to 20) will appear next to the brightness icon in the top right corner of the display. џ To adjust display contrast, press the controller (icon appears) and rotate

it. Contrast level (from 0 to 20) will appear next to the contrast icon in the top right corner of the display. џ Point the unit at a warm object located at a certain distance, 100 meters, for

Powering on and calibration џ Press briefly the “ON” (1) button to power on the sight. In case of low

battery icon will start flashing. џ Do the calibration of image. Calibration levels background temperature of

example. џ Adjust the focus by turning the ring for lens internal focusing (6). џ After this adjustment no further dioptre adjustment should be required,

the microbolometer and eliminates image flaws. џ There are three calibration modes: manual (M), semiautomatic (H) and

regardless of distance or other factors. Adjust image quality only with the ring (6) for lens internal focusing.

automatic (А).

Page 7 of the Pulsar Apex XD38 user manual — H ,
Page 7 · cliquer pour agrandir
Page 7

џ Hold down the “MODE” (3) button to activate colour inversion mode

the auxiliary cross within the limiting frame until the cross matches the point of impact. Note. After the image freezes, you do not need to keep your weapon pointed at the target. џ Pressing the controller button allows you to switch direction of auxiliary

(functions “White hot” and “Black hot”). When function “White hot” is used, warm objects are represented in shades of bright colour; “Black hot” renders objects in shades of dark colour.

cross (horizontal or vertical). Long press of the controller button saves zeroing settings and exits the menu. џ Saving the settings is confirmed with “Ok” message displayed instead of

ZEROING

The sight features two zeroing methods - “one shot” zeroing and using FREEZE function. Zeroing should be done at operating temperatures, by following the order of these steps:

the coordinates. џ After exiting the menu, the image returns to normal. Note: zeroing parameters (coordinates X; Y) are saved in the sight's memory as number 1 in the menu option “Weapon choice”. If you want to zero in the sight using another weapon or another distance, select option 2 or 3 (details in the menu option “Weapon choice” section 12) and do the zeroing.

One shot zeroing џ Mount the rifle with the sight installed on a bench rest. џ Set a target at a distance of about 100m. џ Adjust the sight according to the instructions of Section 9 “OPERATION”. џ Aim the firearm at the target using the mechanical sight. џ Take a shot. If the point of impact does not match the aiming point, press the

MENU

controller (9) to enter menu M2 and rotate the controller to select option “Zeroing” marked with icon. џ Red auxiliary cross (C) appears in the centre of display. On the right of the

OPERATING THE MENU Long press of the controller – entering the menu. Rotating the controller – menu navigation. Short press of controller – entering menu option; selecting value in menu option, exiting menu option or moving to the next parameter (clock mode). Long press of controller – exiting menu option and menu (depending on the cursor actual position). Automatic exit the menu takes place after more than 10 seconds of inactivity (no navigation).

icon appear horizontal arrows and coordinated of the auxiliary cross . џ Holding the reticle in the aiming point, by rotating

the controller (9) move the auxiliary cross (С) horizontally or vertically relative to the reticle until the auxiliary cross matches the point of impact (P) (see pic.). џ To switch between movement direction push the

C P

THE SIGHT HAS TWO MENUS M1 – menu 1 (main menu); М2 – menu 2 (additional menu); Active submenu is highlighted with a frame . To switch to the other menu, rotate the controller and move the cursor (the frame will be flashing), press briefly the controller.

controller (9) to hear a click. Vertical lines appear next to the icon . Note: the auxiliary cross moves only within the limiting frame (see pic.) that defines its travel range: 200 clicks horizontally (+100/-100) and 200 clicks vertically (+100/-100). џ Exit submenu “Zeroing” with a long press of the controller button. Message

H ,

OK confirms successful operation. The reticle will now move to the point of impact. Attention! Do not turn off the sight before zeroing settings are saved, otherwise your settings will be lost. џ Take another shot - the point of impact should now match the aiming point. џ The sight should now be zeroed-in for the specified distance.

STATUS BAR Status bar in the bottom part of the display shows information as follows: 1. Number of weapon choice (1,2,3): 2. Operation mode (“Rocks”,”Forest”,”Identification”): 3. Calibration modes - manual, semiautomatic and automatic: 4. 2x smooth digital zoom is on: 5. Image inversion is on: 6. Running time: 7. Battery charge level or connected external battery:

Zeroing with “Freeze” function џ Before using this function, please take a shot. џ Select “Freeze” function in submenu M2. џ Sight will prompt you to press any button on the sight or wireless control

within 30 seconds to freeze (memorize) the image. The status bar shows corresponding icon. џ Before pressing a button match the reticle of the sight with the aiming point

(as a rule - target centre). After button is pressed, the image “freezes” and a limiting frame with an auxiliary cross appear. Rotating the controller, move

Page 8 of the Pulsar Apex XD38 user manual — MENU М2
Page 8 · cliquer pour agrandir
Page 8

Menu М1 includes: џ Selection of operation mode џ Selection of calibration mode џ Weapon selection (1;2;3) џ Selection of preloaded reticle џ Brightness control of onscreen symbols

Pulsar Apex XD38 — MENU M1 diagram (page 8)
Fig. 5

џ Confirm your choice by a short press of the controller. џ List and full description of the reticles can be found at www.pulsar-nv.com

(Support => Download section). Note: adequate operation of APEX reticles is supported for the basic magnification for each model (1.5x ; 2x ; 3x), and in the “PiP” mode (“Picture in Picture”).

(menu and status bar) џ Reticle colour selection џ Function PiP

Brightness control of onscreen symbols џ To select option, rotate and press the controller (9). џ Rotate the controller to select brightness level of icons – from 1 to 10. џ Confirm your choice by a short press of the controller.

Menu М2 includesџ One shot zeroing џ “Freeze” zeroing џ Selection/disable of video output signal
Pulsar Apex XD38 — MENU M1 diagram (page 8)
Fig. 6

Reticle colour selection џ To switch between two reticle colours (black or white), press and rotate the

(PAL, NTSC) џ Clock setup џ Remote control activation џ Defective pixel repair option џ Return to default settings

controller. џ Confirm your choice by a short press of the controller.

Function PiP Function PiP (“picture in picture”) allows you to enlarge central area of the reticle twice which facilitates aiming without narrowing the field of view. џ Select “Yes” to activate the mode. Select “No” to deactivate. џ Confirm your choice by a short press of the controller. Note: digital zoom does not work when function PiP is activated.

MENU M1

Operation modes There are three automatic operating modes: “Rocks” (enhanced contrast), “Forest” (low contrast) and “Identification” (improved detail rendering). Each mode includes optimal combination of parameters (brightness, contrast, gain etc.) to deliver best possible image in specific viewing conditions. џ To select an option, press and rotate the controller. џ Short press of the controller to confirm your choice. џ Icon of the selected mode is shown in the status bar.

MENU М2

One shot zeroing Please refer to section 10 “ZEROING”.

Zeroing with “Freeze” function Please refer to section 10 “ZEROING”.

Weapon selection (1,2,3) This menu option allows selection of three positions of the aiming point for various types of weapons or for various distances. Also this option allows you to save three types of reticle for each weapon. џ To select option, press controller button and select number out of the list (1; 2; 3). џ Confirm your choice by a short press of the controller button. џ Number of the selected variant of the weapon to use is shown in the status

Selection/disable of video output signal џ Press the controller button and rotate it to select output video signal – PAL

or NTSC (video output is disabled by default). џ To disable the video output, select option “OFF”. Disabled video output

reduces power consumption. џ Confirm your choice by a short press of the controller button.

Clock setup џ Press and rotate the controller (9) to select time format: 24/AM/PM. џ Press the controller to proceed to hour setup. Set the hour value rotating

bar in the lower portion of the display. Note. Originally the reticle for all the three variants is located in the display centre (coordinates X=0;Y=0). Further on, each type of weapon (distance) requires individual zeroing.

the controller. џ Press the controller to proceed to minute setup. Set the minute value. џ To exit submenu, hold down the controller (9) for two seconds. Or wait ten

Selection of calibration mode Please refer to section 9 “Operation”.

seconds to exit automatically.

Remote control activation Please refer to section 12.

Selection of preloaded reticle This menu option allows selection of one of the 10 preloaded reticles. Menu option shows number of the reticle. џ To select option, press controller button and select reticle number out of the

list. Corresponding reticle will be shown on the display.

Page 9 of the Pulsar Apex XD38 user manual — WEAVER RAIL 7/8“
Page 9 · cliquer pour agrandir
Page 9

Defective pixel repair џ When operating the thermal imager, there is a possibility of defective (dead)

Display contrast level – 12; Digital zoom – x1; Image inversion – off; Function “PiP” – off To cancel return to default settings, select “No” and press controller button to confirm. Note: zeroing coordinates do not return to default for all types of weapon.

pixels (bright or dark dots with constant brightness) appearing on the detector which are visible on the image. џ Thermal sights Apex provide an opportunity to repair defective pixels on the

detector using a software-based method. џ Press and hold the controller (9) for two seconds to enter the menu. џ Rotate the controller to select icon and press the controller. џ Select icon in the pop-up submenu and press the controller. џ A cross appears in the centre of display, coordinates (X;Y) of the cross relative to the centre of display appear in the place of pop-up icons, icons disappear. џ Rotate the controller to align the cross with a defective pixel (if the alignment

VIDEO OUTPUT

Video output is designed to connect external recording devices and to transmit video signal to monitors, TV sets etc. џ Connect the plug (13) of the cable to the jack (10) of the sight by matching

is correct, the defective pixel should go out). џ Switch direction of the cross from horizontal to vertical by a short press of the

the notch in the plug connector and the protrusion of the jack (10) (see the scheme). џ Secure the cable by turning clockwise the locking ring of the plug (13). џ Connect the signal receiver to the jack (14) of the cable. џ Turn on the sight – image will appear on the external device. Please make

controller. џ After the centre of the cross is aligned with a defective pixel, press the MODE

(3) button to repair the pixel. џ In case of success a short “OK” message appears in the place of the

coordinates. џ Further on, move the cross to repair another defective pixel. When moving

sure the external device is in the AV mode. џ To record video, you can use video recorders such as Yukon MPR

the cross to the coordinates area, the latter goes to the lower right portion of the display.

(#27041) / CVR640 (#17044) and others. Note: it is not recommended to attach the CVR640 on the sight because the video recorder is not designed for heavy shock resistance.

Return to default defective pixel pattern џ If you wish to return to the default defective pixel pattern (i.e. restore all

defective pixels previously repaired), select icon in the pop-up submenu and press the controller. џ Options “Yes” and “No” appear on the right of the icon. џ Rotate the controller to select “Yes” and press the controller. џ If you choose not to return to default pixel pattern, select “No” and press the

WIRELESS REMOTE CONTROL

The wireless remote control duplicates functions of the sight, calibration function and digital zoom/PiP function. It has three buttons: џ Button “ON” (16) – turning the sight on/off (press for two seconds to

controller. џ To exit the main menu, keep the controller pressed for two seconds or wait 10

seconds to exit automatically. Attention! One or two pixels in the form of bright white or black 1-2 pixels dots are allowed on the display of thermal imager. These pixels cannot be repaired and are not a defect.

deactivate). џ Button “CAL” (17) – image calibration. џ Button “ZOOM/PiP” (18) – digital zoom on/off or function “PiP” on/off. To start using the wireless remote control you will need to activate it: џ Turn on the scope and select menu option “RC activation” (icon ). џ Press controller button, a message “WAIT” will show up and countdown

Restore of default settings To return to default settings: џ Rotate the controller to select “Default settings”. Press the controller button. џ To activate return to default settings, rotate the controller to select “Yes”,

will start within which you need to press any button of the RC. џ If the activation is successful, a message “Complete” will show up next to

icon. The RC is ready for use. џ If the RC does not work, replace the battery. To do this, unscrew the screws

press the controller button. The following settings will return to their original status before the changes: Operation mode – “Rocks”; Calibration mode – automatic; Weapon selection – 1; Selection of preloaded reticle – 1 (for all weapon types); Reticle colour – black; Brightness of onscreen symbols (menu and status bar) – 5; Video output – off; Display brightness level – 12;

on the rear panel of the RC, remove the cover, pull out the old battery and insert a new CR2032 battery.

WEAVER RAIL 7/8“

With the help of the Weaver rail (11) you can attach accessories such as: џ External power supply EPS3 (#79111).

Page 10 of the Pulsar Apex XD38 user manual — TROUBLESHOOTING
Page 10 · cliquer pour agrandir
Page 10

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

TECHNICAL INSPECTION

The sight will not turn on.

Batteries have been incorrectly installed.

Reinstall the batteries observing polarity.

It is recommended that you inspect the sight before every use. Make sure to check for the following: џ Visually inspect that the unit is free from any physical damage; cracks, dents

Oxidized contact points in the battery compartment due to “leaky” batteries or contact points becoming exposed to a chemically reactive solution.

Clean the battery compartment, focusing on the contacts.

or signs of corrosion which may disqualify it from proper use. џ Check the sturdiness and proper fit of the mounting system. џ Ensure that the objective lens and eyepiece are free of cracks, grease spots,

The batteries are fully exhausted or one or several batteries are faulty.

Install fresh batteries. Use spare battery container.

dirt, water stains and other residue before use. џ Visually inspect the condition of the battery and the battery compartment; the

battery should be free of electrolyte and oxidation residue, especially where the battery makes contact with metal. џ Verify the proper function of the following: selector switch, display brightness

The image is blurry, with vertical stripes and uneven background.

Calibration is to be done.

Do the calibration according to section 9 “OPERATION”.

The image is too dark.

The lowest brightness level is set.

Adjust brightness by rotating the controller (9).

adjustment knob and other operation buttons. џ Verify the smoothness of the objective lens focus knob, dioptre focus knob.

The reticle is blurred and cannot be focused with the dioptre knob.

The dioptre cannot be adjusted to your eyesight.

If you wear prescription glasses with a range of +/- 4, keep glasses on when looking through the eyepiece.

TECHNICAL MAINTENANCE

With a crisp image of the reticle, the image of the observed target that is at least 30 m away is blurred.

Dust and condensate are covering the outside optical surfaces after the sight was brought in from the cold into a warm environment, for example.

Clean the lens surfaces with a blower and soft lens cloth. Let the sight dry by leaving it in a warm environment for 4 hours.

Technical maintenance should be done at least twice a year, includes the following steps: џ Clean the outside metal and plastic surfaces from dust, dirt and moisture;

wipe the scope with a soft lint free cloth. џ Clean the battery compartment's electric contact points using an oil-free

The objective lens is not focused.

Adjust the image by rotating the lens knob (6).

solvent. џ Inspect the eyepiece lens and the objective lens and gently blow off any dust

The aiming point shifts after firing rounds. The sight will not focus.

The sight is not mounted securely or the mount was not fixed with thread sealant.

Check that the sight has been securely mounted, make sure that the same type and calibre bullets are being used as when the scope was initially zeroed; if your sight was zeroed during the summer, and is now being used in the winter (or the other way round), a small displacement of the aiming point is possible.

and sand, and clean using lens cleaner and a soft cloth; see section 6 “GUIDELINES FOR OPERATION”.

STORAGE

Always store the unit in its carrying case in a dry, well-ventilated space. For prolonged storage, remove the batteries.

The sight will not focus.

Wrong settings.

Adjust the sight according to the instructions given in the Section 9 “OPERATION” and check the surfaces of the eyepiece and objective lenses and clean them if necessary from dust, condensation, frost, etc; to prevent fogging in cold weather, apply a special anti-fog solution.

TROUBLESHOOTING

Listed below are some potential problems that may occur when using the scope. Carry out the recommended checks and troubleshooting steps in the order listed. Please note that the table does not list all of the possible problems. If the problem experienced with the scope is not listed, or if the suggested action meant to correct it does not resolve the problem, please contact the manufacturer.

The scope is used in day light at long working distance.

Check focusing of the scope in night conditions.

The sight cannot be started with wireless remote control.

Remote control is not activated.

Activate the remote according to instructions in section 13.

Low battery.

Install a new CR2032 battery.

The unit does not operate on external power supply.

Make sure your power supply provides output voltage. Make sure the central pin of the external power supply (15) and plug contacts (13) are intact.

Page 11 of the Pulsar Apex XD38 user manual — PROBLEM
Page 11 · cliquer pour agrandir
Page 11
Pulsar Apex XD38 — PROBLEM diagram (page 11)
Fig. 7
Pulsar Apex XD38 — PROBLEM diagram (page 11)
Fig. 8
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Pulsar Apex XD38

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Pulsar Apex XD38

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Pulsar Apex XD38 manuel PDF

55 pages·4.7 MB·Divers·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…