Manuel d'utilisation / d'entretien du produit 00278A2 du fabricant AcuRite
Aller à la page of 12
Instruction Manual SAVE THIS MANU AL FOR FUTURE REFERENCE. Questions? Contact Cust omer Suppor t at ( 8 77) 22 1 - 1 25 2 or visit www . AcuRite .com. CONTENTS Unpac king Instr uctions ........... 2 P ackage Contents .................. 2 Product R egistration .
2 Congratulations on y our new A cuRite product. T o ensure t he best possible product perf ormance, please read t his manual in its entirety and retain it for future ref erence. Unpac king Ins tructions Remo v e the protective lm t hat is applied to the LCD screen prior to using this product.
3 Features & Benets Thermometer Displa y 1 17 2 3 4 5 6 7 8 1 . Meat Type Setup Indicator Select Beef, V eal, Chicken, Pork, Poultr y , Lamb, Fish, Custom or Boil. 2. Meat Doneness Setup Indicator Select Rare, Medium or W ell done; temperatures based on USDA recommended guidelines.
4 SETUP Install or Replace Batteries AcuRite recommends high quality alkaline batteries f or the best product per for mance. Heavy duty or rec hargeable batteries are not recommended.
5 Food Preparation Consuming raw or under cooked meats, poultr y , seaf ood, shellsh, or eggs may increase your risk of food-borne illness, especiall y if you hav e cer tain medical conditions. The USD A recommends certain guidelines be me t when preparing meat and seafood.
6 The preference set order is as follows: BEEF , VEAL, C HIC KEN , PORK, POUL TRY , L AMB, FISH, CUS TOM, B OIL, TIMER* 3. T o save your selection, press and r elease the “SELECT” button when t he desired meat type is displayed. * For TIMER, see setup See Timer Se tup on page 7 Meat Doneness Setup 1 .
7 Be careful when touc hing the tem perature probe and pr obe wire if it has been in or near hot food or sur f aces. Remaining Cook Time Remaining Cook Time estimates t he amount of time food needs to cook . Cook time is deter mined by measuring and monitoring t he cooking process, then applying a series of estimating me thods.
8 5. When 0:00:00 is reached, t hermome ter/pager (if in use) beeps/vibrates until “SELECT” or “ ” is pressed. Backlight Press the Bac klight button to moment arily illuminat e the displa y for 5 seconds. Press and HOLD Backlight button f or 3 seconds to keep display illuminated.
9 Chec k Probe “CHEC K PROBE” indicates a probe error and is shown with a diagnostic code: Diagnostic Code Problem Solution No Probe cord is not connected to t he ther mometer . V er ify cord connection is secure or reconnect cord. SC Probe cord is not functioning properly .
10 Care & Maintenance Store in a dr y location at room temperature. Clean ther mometer wit h a sof t, damp clot h. T emperature probe should be wiped clean with warm water immediately af t er direct contact with f oods. DO NOT place display unit on or near hot surf aces.
11 At AcuRite, we proudly uphold our commitment to quality tec hnology . Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology . Visit www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AcuRite 00278A2 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AcuRite 00278A2 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AcuRite 00278A2, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AcuRite 00278A2 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AcuRite 00278A2, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AcuRite 00278A2.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AcuRite 00278A2. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AcuRite 00278A2 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.