INTRODUCTION

Thank you for choosing the VISTADOOR video intercom system. You have purchased a high quality system with a stainless steel cover. The elaborate stainless steel covers are made by hand and thus have individual characteristics that should be considered a sign of quality.

INSTALLATION OF THE OUTDOOR STATION

Notes on caring for stainless steel Please never clean the stainless steel surfaces with standard cleaning materials, as these are too harsh. Please simply clean using spray desi- gned for the cleaning and care of stainless steel. If this is not available please use only clear water. Brushed surfaces should always be cleaned with the grain and never in a circular motion. This will avoid the creation of scratches. Failure to observe these notes may lead to discolouration or even to rust damage in extreme cases.

The intercom system is designed to be flush-mounted.

Preparation When removing the front cover, take care that the indicator field and the nameplate do not fall out and get damaged.

The camera should be mounted at a height of approx. 1.5-1.6m (middle of the camera) (Fig. 3). Before installing the intercom system, test whether the camera captures a sufficient image of the visitor. If necessary, adjust the installation height and location to suit the local conditions.

The system should be assembled by a specialist.

1. Remove the four screws in the stainless steel front plate using a Torx key (T10) and then lift this carefully upwards. Make sure you do not tear off the microphone cable. You can now reveal the flush mounted shell by removing the outdoor station. 2. Hold the wall box straight on the wall and draw around it on the wall with a suitable pencil. Take care that the necessary connecting cables are in the middle part of the wall box. The cables should not be measured too short. 3. The cable feedthrough can be detached with a sharp knife.

Key

1. Camera 2. Loudspeaker perforations 3. Bell button 4. Microphone 4.1. Connection for microphone 5. Casing screws 6. Lightness sensor 7. Volume potentiometer 8. Dip switch for the opening time of the door opener 9. Dip switch for the ID code 10. Connection terminal door opener 11. Connection terminal power supply 12. Connection terminal signal line 13. Connection terminal external camera 14. Installation aid 15. Outdoor unit 15.1. Stainless steel front plate 15.2. Inner housing 15.3. Wall box

4. In order to anchor the wall box to the wall, first use the holes in the base of the wall box to mark the 8 fixing holes in the wall and then drill corresponding holes (diameter approx. 6 mm). 5. Next place the supplied dowels in the holes. The wall box can now be affixed with the 4 outer screws. Take care here to ensure that the wall box is level; check this if necessary with a spirit level. The wall box must also not be twisted.

PREPARATION FOR INSTALLATION

6. For plastering insert the supplied plaster aid into the wall box. This prevents the wall box from being filled with mortar / plaster. When plastering make sure that the threaded inserts will not be soiled with mortar / plaster. 7. Insert the outer unit into the wall box. In order to prevent the outer unit from falling out, use the supplied installation aid (14). It is easily screwed to the wall box using one of the Torx screws and holds the outer unit in position. 8. Remove the cover over the screw terminals on the outer unit and feed the cable through the relevant inlet. 9. Now connect the cable to the intercom system. (See Point CONNECTION)

The following lines are required:

Single-family house (VDV-910): 4 lines from the outdoor unit to the indoor unit and 2 lines from the outdoor unit to the door opener.

Duplex house (VDV-920): 4 lines per bell push-button from the outside unit to each apartment are required here, i.e. you need 8 lines from the outside station to the inside (4 each per family 1 and 2) and 2 lines for the door opener.

Up to four indoor units can be connected in parallel per residential unit. The connection can either be laid from the indoor station or in a star formation from a central point (distribution box).

Fit the name plate The nameplate consists of two transparent plastic parts, which are joined together with 2 respectively 4 small screws.

The lines should be laid in such a way that they are fed out of the wall directly behind the relevant outdoor/indoor unit.

Page 2 of the ME VDV 920 user manual — OPERATION
Page 2 · cliquer pour agrandir
Page 2

ENGLISH | VDV-900

10. Remove both screws on the nameplate and take it apart; the foil for inscription is between the plastic parts. 11. Write on the foil with a smear-resistant felt pen or print a nameplate inlay* using a PC and a printer. 12. Place the written nameplate inlay between the two plastic parts and screw these back together.

first power supply unit. The second power supply unit should be connected with a short line to the indoor or outdoor station that is farthest away so that any drop in current in the connection line can be compensated.

Connecting an external camera An external camera can be connected to this screw terminal (figure 2) in order, for example, to provide additional monitoring of areas that cannot be seen by the main camera. All cameras can be connected that require operating voltage of 12 V DC and supply an FBAS video signal. The video line is connected to the terminal (VIDEO IN) and the earth line to the terminal (GND), operating voltage for the camera is taken from the terminals ‘+12V DC OUT’ (positive pole) and ‘GND’ (negative pole). The external camera automatically has the ID 4 (see chapter on ID code). No sound transmission is possible when the external camera is active. When using the VDV 500 XCam, the X-module is not needed.

*Size of the nameplateVDV 910: 71 mm x 34 mm VDV 920: 71 mm x 15 mm

13. In order to be able to replace the front cover on the outdoor station first insert the nameplates into the outdoor station and fix them on the sides using the supplied tape strips so that they cannot fall out. Alternatively you many also fix the nameplates with transparent sticky tape. 14. Remove the assembly aid and secure the outdoor station from falling with your hand. A second person can help. 15. Replace the microphone plug into the circuit board and replace the front cover on the outdoor station. Take care not to crush the microphone cable. 16. Screw on the front cover with the relevant 4 Torx screws. Please ensure that the screws are not tilted or over-tightened. The maxi- mum tightening torque is 1.2 Nm. This value must not be exceeded as the threads in the flush mounted shell can otherwise become unusable or fall out.

POSSIBLE SETTINGS

1,2 Nm max.

The outdoor station offers the following possibilities to set the system to your personal circumstances:

Volume of the outdoor station The potentiometer (7) is used to set the volume on the outdoor station. To set the highest volume, turn the potentiometer carefully clockwise as far as possible. Reduce the volume by turning in an anti-clockwise direction.

CONNECTION

ID code If several outdoor stations are switched in parallel (e.g. at the gate ent- rance and the house) then the ID code is set via the dip switch (9). This makes it possible to activate the individual outdoor units in sequence, e.g. in order to monitor the coverage of the relevant outdoor unit. The switch is carried out on the indoor station with the ‘monitor’ switch.

Connect the laid line to Audio 1, +15V, GND and Video 1 (figure 2) on the outdoor station and connect it with the indoor station/s. These are also present on the indoor station and need only be connected with one another 1:1.

ID1 = Switch 1 ‘on’ Switch 2 ‘on’ ID2 = Switch 1 ‘on’ Switch 2 ‘off’ ID3 = Switch 1 ‘off’ Switch 2 ‘on’

Connecting a door opener The door opener is connected directly to the outdoor station by two lines (figure 2.2, no. 12). No additional power supply is necessary to control the door opener. The door opener must be designed for 12 V direct current and may not require more than 1 A current. The two connector terminals are marked ‘Doorlock’ and ‘GND’ if the door opener needs to be poled. ‘GND’ is negative.

Opening time of the door opener The DIP switch (8) is used to set the time the door opener remains activated. The options are either 1 second or 5. The factory setting is 5 seconds, which works for most conventional door openers.

Switch to the left to “5S” for 5 seconds open time. Switch to the right to “1S” for 1 second open time.

Connecting the power supply The power supply can either be connected to the indoor or to the out- door station. Separate screw terminals exist for this purpose (figure 2). It is also possible to connect the power supply directly to the signal line, e.g. if all signal lines have been laid from the fuse box to the outdoor and indoor units. The power supply unit then needs to be connected with earth (GND) and +15V. Up to 8 units can be supplied with power from one power supply unit. A second power supply unit is required if there are more than eight units, e.g. if 2 outdoor and 7 indoor stations need to be used. The second power supply unit can simply be switched parallel to the

OPERATION

1. Press the bell push-button. 2. The preset ring tone sounds on its inside station/s and the screen displays the outside station view. 3. Accept the dialogue on the inside unit by briefly pressing the pressto-talk button (MOUTH). 4. If an additional camera is present at the outside station, you may switch over to this camera by pressing the “MONITOR” button.
Page 3 of the ME VDV 920 user manual — SAFETY NOTES
Page 3 · cliquer pour agrandir
Page 3

VDV-900 | ENGLISH

Pressing the „Monitor“ button again switches you back to the internal camera. 5. If a door opener is connected then you can activate the door opener by pressing briefly on the door opener button (KEY). 6. Switch the system back to standby operation by briefly pressing the speak button (MOUTH).

For reasons of safety and licensing (CE), unauthorised conversion and / or modification of the product is prohibited. The design of the product complies with protection class 1. Only a standard mains socket (230V~/50Hz) of the public mains supply may be used to power the device. Devices powered by mains voltage must be kept away from children. Please therefore be particularly careful in the presence of children.

TECHNICAL DATA

Do not take the product apart! There is a danger of lethal electric shock!

Operating voltage: 15 V DC Current consumption: 130 ± 50 mA Camera detection angle: 135° horizontal / 100° vertical Temperature range: -10°C to +50°C Dimensions (w x h x d): 160 x 233 x 3 mm (without lens) Wall box (w x h x d): 133 x 210 x 35 mm Door opener connection: DC 12V, max. 1A

Do not leave packaging material lying about since plastic foils and pockets and polystyrene parts etc. could be lethal toys for children.

The interior units are suitable only for dry interior rooms (not ba- throoms and other moist places). Do not allow the devices to get moist or wet. There is a danger of lethal electric shock!

Please consult a specialist should you have doubts regarding the method of operation, the safety, or the connections of the device.

INFORMATION

Information regarding CE - Conformity The functionality of the unit can be affected by the influence of strong static, electrical or high frequency fields (discharging, mobile phones, radios, microwaves).

Handle the product with care – it is sensitive to bumps, knocks or falls even from low heights.

GB These operating instruction are published by m-e GmbH modern-electronics, An den Kolonaten 37, 26160 Bad Zwischenahn/Germany

Cleaning and maintenance Always disconnect mains powered units from the mains supply before cleaning (disconnect the plug). The unit housing can be cleaned using a soapy soft cloth. Do not use any abrasive materials or chemicals. Remove dust build-up from ventilation slits using a brush and clean up using a vacuum cleaner. Do not hold the vacuum cleaner nozzle directly against the unit.

The operating instructions reflect the current technical specifications at time of print. We reserve the right to change the technical or physical specifications.

Safety instruction In the event of damage to the housing, connectors, power cables or isolation shielding, switch off the device immediately and disconnect from the mains power. ELECTRIC SHOCK – DANGER OF LOSS OF LIFE. (Unplug the mains connector from the socket!). Damage should be repaired immediately by a specialist!

Never carry out repairs yourself!

Warranty

2 years warranty from date of purchasing, on base of correct using.

The producer is not responsible for consequential damages which are effected directly or indirectly from this item.

SAFETY NOTES

The warranty will be null and void in case of damages arising from violations of these operating instructions. We are not liable for consequential damages!

We accept no liability for material damages or injuries arising from inappropriate use or violation of the safety instructions. In such cases all warranty claims are null and void!

Poser une question sur : ME VDV 920

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le ME VDV 920

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

ME VDV 920 manuel PDF

16 pages·1.2 MB·Interphone·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…