FR
Leica logo
Notice d'utilisation officielle

Leica DISTO E7500

26 pages·1.9 MB·Télémètre laser·PDF·EN
Leica DISTO E7500
Table des matières 52 sections Instrument Set-up · Introduction · Overview · Basic measuring screen · … AfficherMasquer
Page 1 of the Leica DISTO E7500 user manual — The original laser distance meter
Page 1 · cliquer pour agrandir
Page 1
Leica DISTO E7500 diagram (page 1)
Fig. 1

The original laser distance meter Leica DISTO TM E7500

The original laser distance meter

Page 3 of the Leica DISTO E7500 user manual — EN Instrument Set-up
Page 3 · cliquer pour agrandir
Page 3

EN Instrument Set-up

Introduction

Overview

The safety instructions and the user manual should be read through carefully before the product is used for the first time.

Leica DISTO E7500 — EN Instrument Set-up diagram (page 3)
Fig. 2 · EN Instrument Set-up

The person responsible for the product must ensure that all users understand these directions and adhere to them.

The symbols used have the following meanings: !WARNING Indicates a potentially hazardous situation or an unintended use which, if not avoided, will result in death or serious injury. !CAUTION Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage.

Page 4 of the Leica DISTO E7500 user manual — FUNC
Page 4 · cliquer pour agrandir
Page 4

EN Instrument Set-up

Basic measuring screen

Selection screen

Leica DISTO E7500 — EN Instrument Set-up diagram (page 4)
Fig. 3 · EN Instrument Set-up
Leica DISTO E7500 — EN Instrument Set-up diagram (page 4)
Fig. 4 · EN Instrument Set-up
Leica DISTO E7500 — EN Instrument Set-up diagram (page 4)
Fig. 5 · EN Instrument Set-up

FUNC

Leica DISTO E7500 — FUNC diagram (page 4)
Fig. 6
Leica DISTO E7500 — FUNC diagram (page 4)
Fig. 7
Show 8 more labels / short text on this page
Status bar · Function / · Settings · Main line · Active function · Favorites · Settings · Help function
Page 5 of the Leica DISTO E7500 user manual — EN Instrument Set-up
Page 5 · cliquer pour agrandir
Page 5

EN Instrument Set-up

Pointfinder (Viewscreen)

Insert batteries

Leica DISTO E7500 — EN Instrument Set-up diagram (page 5)
Fig. 8 · EN Instrument Set-up
Leica DISTO E7500 — EN Instrument Set-up diagram (page 5)
Fig. 9 · EN Instrument Set-up

To ensure a reliable use, do not use zinc- carbon batteries. We recommend using high quality batteries. Change batteries when battery symbol is flashing.

Zoom (1x, 2x, 4x) with navigation keys up and down

Page 6 of the Leica DISTO E7500 user manual — EN Operations
Page 6 · cliquer pour agrandir
Page 6

EN Operations

Leica DISTO E7500 — EN Operations diagram (page 6)
Fig. 10 · EN Operations

If no key is pressed for 180 sec, the device switches off au- tomatically.

If the info icon appears with a number, observe the instructions in section "Message Codes". Example:

The orientation of the endpiece is automatically detected and the zero point is accordingly ad- justed.

1 2 secThe minimum a min. max. tance measured 2 max.). The last displayed in the 8 . Used to measure room diagonals (maximum values) or horizontal distance (minimum values)nd maximum disis displayed (min, value measured is main line. 5 3 2 m Leic
Page 7 of the Leica DISTO E7500 user manual — EN Operations
Page 7 · cliquer pour agrandir
Page 7

EN Operations

Leica DISTO E7500 — EN Operations diagram (page 7)
Fig. 11 · EN Operations

This process can be repeated as required. The same process can be used for adding or subtracting areas or volumes.

The next meas- urement is added to the previous one.

The next meas- urement is sub- tracted from the previous one.

This is a great help for outdoor measuring. The integrated pointfinder (viewscreen) shows the target on the display. The device measures in the middle of the cross hair, even if the laser dot is not visible. Parallax errors occur when the pointfinder camera is used on close targets, with the effect that the laser appears dis- placed in the crosshair. In this case rely on the real laser dot.

Page 8 of the Leica DISTO E7500 user manual — EN Settings
Page 8 · cliquer pour agrandir
Page 8

EN Settings

Leica DISTO E7500 — EN Settings diagram (page 8)
Fig. 12 · EN Settings
Distance units Beep Keypad lock Tilt calibration Favorites Illumination Offset Reset Information
Page 9 of the Leica DISTO E7500 user manual — Distance units
Page 9 · cliquer pour agrandir
Page 9
Leica DISTO E7500 — Distance units diagram (page 9)
Fig. 13 · Distance units
0.000 m 0.00 m0.0 in 0 in 1/32 0.0 mm0 in 1/16 0.00 ft0 in 1/8 0‘00‘‘ 1/320 in 1/4 0‘00‘‘ 1/160.000 yd 0‘00‘‘ 1/8

The digital level is displayed in the status bar.

Page 10 of the Leica DISTO E7500 user manual — De-/Activate keylock
Page 10 · cliquer pour agrandir
Page 10
Leica DISTO E7500 — De-/Activate keylock diagram (page 10)
Fig. 14 · De-/Activate keylock
1 OFFTo deactivate, repeat procedure. The keylock 2 is active if device is switched off. ON3 Exit settings.12 within 2 sec
Page 11 of the Leica DISTO E7500 user manual — Calibration of tilt sensor (Tilt Calibration)
Page 11 · cliquer pour agrandir
Page 11
Leica DISTO E7500 — Calibration of tilt sensor (Tilt Calibration) diagram (page 11)
Fig. 15 · Calibration of tilt sensor (Tilt Calibration)

Turn the device horizontally by 180° and place it again on absolutely flat surface.

After 2 sec the device goes back to the basic mode.

Turn the device horizontally by 180° and place it again on absolutely flat surface.

Page 12 of the Leica DISTO E7500 user manual — Personalized favorites
Page 12 · cliquer pour agrandir
Page 12
Leica DISTO E7500 — Personalized favorites diagram (page 12)
Fig. 16 · Personalized favorites

4 Press selection key left or right. Function is set as favorite above the corresponding se- lection key.

Short cut: Press 2 sec on a selection-key in the measuring mode.

Page 13 of the Leica DISTO E7500 user manual — Offset
Page 13 · cliquer pour agrandir
Page 13
Leica DISTO E7500 — Offset diagram (page 13)
Fig. 17 · Offset

An offset adds or subtracts a specified value automatically to or from all measurements. This func- tion allows tolerances to be taken into account. The offset icon is displayed.

Reset returns the instrument to the factory settings. All custom- ized settings and memories are lost.

Page 14 of the Leica DISTO E7500 user manual — Functions
Page 14 · cliquer pour agrandir
Page 14
Leica DISTO E7500 — Functions diagram (page 14)
Fig. 18 · Functions

The self release starts if ON/Measure key is pressed.

Page 15 of the Leica DISTO E7500 user manual — Functions
Page 15 · cliquer pour agrandir
Page 15
Leica DISTO E7500 — Functions diagram (page 15)
Fig. 19 · Functions

Distance is measured from the rear of the device (standard setting).

Distance is measured from a Leica DISTO Adapter FTA 360 (lock symbol = perma- nently)

Distance is measured from the front of the device (lock symbol = permanently).

If device is switched off, reference goes back to standard setting (rear of the device).

If you use an original Leica DISTO adapter, the reference does not need to be adapted to tripod thread!

Page 16 of the Leica DISTO E7500 user manual — Memory
Page 16 · cliquer pour agrandir
Page 16
Leica DISTO E7500 — Memory diagram (page 16)
Fig. 20 · Memory

Use Up/Down navigation keys to show more detailed results of the speci- fic measurement.

Target surfaces: Measuring errors can occur when measuring to colourless liquids, glass, styrofoam or semi-permea- ble surfaces or when aiming at high gloss surfaces. Against dark surfaces the measuring time in- creases.

(up to 360° and a transverse tilt of ±10°)

Page 17 of the Leica DISTO E7500 user manual — Area
Page 17 · cliquer pour agrandir
Page 17
Leica DISTO E7500 — Area diagram (page 17)
Fig. 21 · Area

The result is shown in the main line and the measured value above. Partial Measurements / Painter function: Press + or - before starting the first measure- ment. Measure and add or subtract distanc- es. Finish with =. Measure 2nd length.

Page 18 of the Leica DISTO E7500 user manual — Volume
Page 18 · cliquer pour agrandir
Page 18
Leica DISTO E7500 — Volume diagram (page 18)
Fig. 22 · Volume
Page 19 of the Leica DISTO E7500 user manual — Stake out
Page 19 · cliquer pour agrandir
Page 19
Leica DISTO E7500 — Stake out diagram (page 19)
Fig. 23 · Stake out

Two different distances (a and b) can be entered to mark off de- fined measured lengths.

Move device slowly along the stake-out line. The distance to the next stake out point is displayed.

0.240 m is missing up to next 0.625 m distance.

When approaching a stake out point to less than 0.1 m the instrument starts to beep. The function can be stopped by pressing the CLEAR/OFF button.

Page 20 of the Leica DISTO E7500 user manual — Pythagoras (2-point)
Page 20 · cliquer pour agrandir
Page 20
Leica DISTO E7500 — Pythagoras (2-point) diagram (page 20)
Fig. 24 · Pythagoras (2-point)

Aim laser at second target.

The result is shown in the main line. Pressing the measuring key for 2 sec in the function ac- tivates automatically Minimum or Maximum measure- ment.

We recommend to use the pythagoras only for indirect horizontal measuring. For height measuring (vertical) it is more precise to use a function with the inclination measuring.

Page 21 of the Leica DISTO E7500 user manual — EN Technical Data
Page 21 · cliquer pour agrandir
Page 21

EN Technical Data

Leica DISTO E7500 — EN Technical Data diagram (page 21)
Fig. 25 · EN Technical Data

* applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC ** applies for 10 to 100 % target reflectivity, high background illumination, - 10 ºC to + 50 ºC *** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m, to 0.20 mm/m between 30 m to 100 m and to 0.30 mm/m for distances above 100 m **** applies for 100 % target reflectivity, background illumi- nation of approximately 30'000 lux ***** after user calibration. Additional angle related devia- tion of +/- 0.01° per degree up to +/-45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by +/-0.1°.

Leica DISTO E7500 — EN Technical Data diagram (page 21)
Fig. 26 · EN Technical Data

Typical Measuring Tolerance* ± 1.0 mm / ~1/16" ***

6 /30 / 60 mm (10 / 50 / 100 m)

For accurate indirect results, the use of a tripod is recommended. For accurate tilt measurements a transverse tilt should be avoided.

Protection class IP65 (dust tight and jet water protected)

Battery durability (2 x AA) up to 5000 measure- ments

Dimension (H x D x W) 143 x 58 x 29 mm 5.6 x 2.28 x 1.14 in

-25 to 70 °C -13 to 158 °F -10 to 50 °C 14 to 122 °F

Page 22 of the Leica DISTO E7500 user manual — Warranty
Page 22 · cliquer pour agrandir
Page 22

EN Message Codes

Care

Safety Instructions

If the message Error does not disappear after switching on the device repeatedly, contact the dealer. If the message InFo appears with a number, press the Clear button and observe the following instructions:

  • Clean the device with a damp, soft cloth.
  • Never immerse the device in water.
  • Never use aggressive cleaning agents or solvents.

The person responsible for the instrument must ensure that all users understand these directions and adhere to them. Areas of responsibility

  • Responsibilities of the manufacturer of the original equipment: Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Internet: <a href="http://www.disto.com" rel="nofollow noopener" target="_blank">www.disto.com</a> The company above is responsible for supplying the product, including the User Manual in a completely safe condition. The company above is not responsible for third party accessories. Responsibilities of the person in charge of the instrument:
  • To understand the safety instructions on the product and the instructions in the User Manual.
  • To be familiar with local safety regulations relating to accident prevention.
  • Always prevent access to the product by unauthorised personnel.

Warranty

No. Cause Correction

Lifetime Manufacturer's Warranty Warranty coverage for the entire usage time of the product according to Leica Geosys- tems International Limited Warranty. Free of charge repair or replacement for all products that suffer defects as a result of faults in mate- rials or manufacturing, for the entire life of the product. 3 Years no Cost Guaranteed service should the product become defective and require servicing under normal conditions of use, as described in the user manual, at no additional charge.

156 Transverse tilt greater than 10°

Hold the instrument without any transverse tilt.

162 Calibration mistake Make sure, the device is placed on a absolutely horizontal and flat surface. Repeat the calibration procedure. If the mistake still occurs, contact your dealer.

204 Calculation error Perform measurement again.

252 Temperature too high Let device cool down.

253 Temperature too low Warm device up.

255 Received signal too weak, measuring time too long

Change target surface (e.g. white paper).

To receive the "3 years no cost" period, the product must be registered at www.leica- geosystems.com/registration within 8 weeks of the purchase date. If the product is not registered, a "2 years no cost" period applies.

256 Received signal too high

Change target surface (e.g. white paper).

257 Too much back- ground light

Shadow target area.

258 Measurement outside of measuring range

Correct range.

260 Laser beam inter- rupted

Repeat measurement.

Page 23 of the Leica DISTO E7500 user manual — EN Safety Instructions
Page 23 · cliquer pour agrandir
Page 23

EN Safety Instructions

  • Permitted use
  • Measuring distances
  • Tilt measurement Prohibited use
  • Using the product without instruction
  • Using outside the stated limits
  • Deactivation of safety systems and removal of explanatory and hazard labels
  • Opening of the equipment by using tools (screwdrivers, etc.)
  • Carrying out modification or conversion of the product
  • Use of accessories from other manufacturers without express approval
  • Deliberate dazzling of third parties; also in the dark
  • Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.)
  • Deliberate or irresponsible behaviour on scaffolding, when using ladders, when measuring near machines which are running or near parts of machines or installations which are unprotected
  • Aiming directly in the sun

Hazards in use!WARNING Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified. Carry out periodic test measurements. Particularly after the instrument has been subject to abnormal use, and before, during and after important measurements. !CAUTION Never attempt to repair the product your- self. In case of damage, contact a local dealer. !WARNING Changes or modifications not expressly approved could void the user’s authority to operate the equipment. Limits of use

Disposal!CAUTION Flat batteries must not be disposed of with household waste. Care for the environment and take them to the collection points provided in accordance with national or local regulations. The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regu- lations in force in your country. Adhere to the national and country specific regulations. Product specific treatment and waste management can be downloaded from our homepage. Electromagnetic Compatibility (EMC)!WARNING The device conforms to the most stringent requirements of the relevant standards and regulations. Yet, the possibility of causing interference in other devices cannot be totally excluded.

Refer to section "Technical data". The device is designed for use in areas permanently habitable by humans. Do not use the product in explosion hazardous areas or in aggressive environments.

Page 24 of the Leica DISTO E7500 user manual — EN Safety Instructions
Page 24 · cliquer pour agrandir
Page 24

EN Safety Instructions

  • FCC statement (applicable in U.S.) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
  • This device may not cause interference and
  • this device must accept any interference, including interference that may cause undesired operation of the device.
  • ce dispositif doit accepter toutes les interférences, y compris les interférences pouvant induire des opérations non souhaitées.
  • Cet appareil est conforme à la section 15 des règlements FCC. Son fonctionnement est soumis aux deux conditions suivantes :
  • cet appareil ne doit pas causer d'interférences nuisibles, et
  • cet appareil doit accepter toute autre interférence reçue, y compris les interférences pouvant entraîner un fonctionnement non désiré. Ce dispositif est conforme à la norme RSS210 d’Industrie Canada. L’utilisation est sujette aux deux conditions suivantes :
  • ce dispositif ne pas doit pas être la source d’interférences nuisibles, et
Page 25 of the Leica DISTO E7500 user manual — Labelling
Page 25 · cliquer pour agrandir
Page 25

EN Safety Instructions

Leica DISTO E7500 — EN Safety Instructions diagram (page 25)
Fig. 27 · EN Safety Instructions

The device produces visible laser beams, which are emitted from the instrument: It is a Class 2 laser product in accordance with: • IEC60825-1 : 2014 „Radiation safety of laser products“ Laser Class 2 products: Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded by aversion responses including the blink reflex. !WARNING Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous. !CAUTION Looking into the laser beam may be hazardous to the eyes.

Labelling

Leica DISTO E7500 — Labelling diagram (page 25)
Fig. 28 · Labelling

Subject to change (drawings, descriptions and technical data) without prior notice.

Page 26 of the Leica DISTO E7500 user manual — Laser classification
Page 26 · cliquer pour agrandir
Page 26

Leica Geosystems AG, Heerbrugg, Switzerland has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems (ISO standard 9001) and Environ- mental Management Systems (ISO standard 14001).

Copyright Leica Geosystems AG, Heerbrugg, Switzerland 2014 Original text (820692 EN)

Pat. No.: WO 9427164, WO 9818019, WO 0244754, WO 0216964, US 5949531, EP 1195617, US 7030969, US 8279421 B2

Leica Geosystems AG CH-9435 Heerbrugg (Switzerland) www.disto.com

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Leica DISTO E7500

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Leica DISTO E7500

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Leica DISTO E7500 manuel PDF

26 pages·1.9 MB·Télémètre laser·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…