Professional rotary laser of extremely rugged design. Horizontal and vertical levelling even under the toughest conditions Automatic self-levelling through electronic vials and servomotors assisted by temperature stable sensors, horizontal and vertical. This unit is equipped with all important laser functions and due to the extreme rugged housing works reliable even under toughest conditions. Dust- and waterproof IP66, preci- sion 1 mm / 10 m, self-levelling range 5 °. Horizontal slopes can be adjusted. The included remote control can control all functions. Titanium Red Laser Class 2. The green laser of the Titanium Green is much more visible than the red. This allows applications over longer distances and working under very bright ambient light conditions. Titanium Green Laser Class 3R. General safety instructions Caution: Do not look directly into the beam. Lasers must be kept out of
reach of children. Never intentionally aim the device at people. This is a quality laser measuring device and is 100% factory adjusted within the stated tolerance. For reasons of product liability, we must also draw your attention to the following: Regularly check the cali- bration before use, after transport and after extended periods of storage. We also wish to point out that absolute calibration is only possible in a specialist workshop. Calibration by yourself is only approximate and the accuracy of the calibration will depend on the care with which you proceed.
Laser light ! Do not stare into the beam or view directly
with magnifiers.
Class 3R laser EN60825-1:2003-10
Warranty The warranty period is 2 years from the date of purchase. The warranty covers all material or manufacturing defects occurring during this time. The following are excluded from warranty: Damage due to improper use (e.g. operation with wrong type of current/voltage, connection to unsuitable power source, fall onto hard surface, etc.) or improper storage, normal wear and tear, and defects which only insignificantly impair the value or suitability for use. Any tampering by unauthorised persons will render this warranty void. In the event that you need to claim warranty, please take the complete device together with all information and the invoice to one of our dealers or send it in to Umarex-Laserliner.

The Titanium is of the self-levelling kind. After it has been put in the required basic position, fine adjustment is being effected automatically. Horizontal and vertical orthogonal adjustments are effected by the self-levelling system (SLS), while the X-, Y- and the Y-axis are scanned by two electronic measuring sen- sors. The working angle is ± 5°.
The Anti-drift system (ADS) prevents mismeasurements. Its principle of func- tion: 10 seconds after ADS has been activated, the laser is permanently being checked for its correct adjustment. In case the instrument has been moved by external influences or the laser has lost its frequency, the system switches itself automatically off and the "tilt"-LED shows a permanent light. After the instrument has been switched on, the ADS is not active. In order to protect the instrument from position changes caused by external influences, the ADS has to be activated by pressing the push-button "tilt"(J). Should the instru- ment be moved by external influences, then the laser is switched off and the "tilt"-LED (K) shows a permanent light. The instrument has to be switched off and -on again if work is to be commenced. This is a simple and reliable prevention of misreadings.
The laser switches itself off for safety reasons, the "tilt"- LED shows a ON permanent light. ON
after 10 sec., short blink signals in tilt display (K). Rotation begins
External influence Adjustment phase Sensor Automatic
Acticate ADS: Press “tilt” but- ton (D), long blink signals in tilt display (K).

P

Q
O

N

K
F
R L
M

J
I H
S
T
A Reference laser outlet
L 5/8 “ tripod adapter for vertical
C Receiver diode for remote control
M Vertical holder (screw adjustment)
O Centric point (with hinge)
G ON / OFF button
H Anzeigen X, Y und Z-Achsen
R Vertical vial for pre-adjustment
I Operating / Battery display
S Charger socket (DC 6V)
T Battery charge display

SensoLite 310 Protection class IP 66
SensoCommander 310 Protection class IP 66 (not for Titanium Green)


SensoLite 120:
SensoLite 200 (not for Titanium Green)


1 IR output signal
2 Receiver field for laser beam
9 Battery compartment (on back)
3 SpotLite marking LED
11 LCD display (on back)
13 All-round marking groove

Commader 50 SensoCommander SensoLite



14 Speed / Angle range / Adjusting axis at auto/man mode / Volume at Hand receiver mode
22 Display measuring range selection
23 Hand receiver above laser level
24 Precisely on laser level
25 Hand receiver below laser level
26 Acoustic signal display
27 Low battery display
18 Hand receiver mode
28 Hand receiver mode /
21 Calibration mode: Saving the new calibration.

Charging the batteries • Before using the divice, fully charge th batteries


Insertion of batteries in the SensoLite and SensoCommander: • Remove the battery cover (9) and insert the batteries as shown by the installation symbol, ensuring that the polarity is correct. Then replace the cover.
Note: Do not expose batteries to excessive heat such as sunshine, fire, etc. Dry batteries must not be recharged. Used batteries must not be disposed of as household waste. Please take them to a collection point for used batteries or for special waste. Ask your local authority for further details. Batteries with the recycling symbol can also be returned to our dealerships or to our Technical Service.

In 1 plane · In 2 planes

Laser modes The following modes can be controlled with the Commander 50 up to a maximum distance of 50 m. Open battery compartment and insert battery according to picture on the right, ensure polarity is correct and close battery compartment. The rotating laser can also be controlled with the SensoCommander.

To establish point mode, press button (16) repeatedly until the laser no longer rotates. The laser can then be precisely positioned to the measuring level with the direction buttons (15).
Use button (16) to set the desired speed of rotation: 0, 150, 500 rpm.
Button (17) can be used to activate and set an intensive light segment with one of 4 different widths. The segment can be positioned with the direction buttons (15).
Working with the optional laser receiver: Switch on the SensoLite laser receiver with the botton (18). With the Commander 50 and SensoCommander you could set the maximum rotary speed, 500 rpm. It is able to detect the laser beam at a great distance now. Move the SensoLite up and down through the laser beam until the middle indicator (24) appears. Mark the measured height at the perimeter marking groove. SpotLite Marking: The projected light beam at the height of the laser beam simplifies precise marking and prevents parallax error.




Universal mount (optional): The laser receiver can be installed on levelling staffs with the aid of the universal mount. The Flexi measuring staff (Art. No. 080.50) is always recommended when measuring from floor heights. It also allows you to determine heights directly without any need for calculation.


Preparing the calibration check It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls, which must be at least 5 metres apart. Switch the device on. The best calibration results are achieved if the device is mounted on a tripod. 1. Mark point A1 on the wall. (Use spot mode.) 2. Turn the device through 180° and mark point A2. You now have a horizontal reference between points A1 and A2.
A2
A1
Performing the calibration check: 3. Position the device as near as possible to the wall at the height of point A1. Now adjust the device in the X axis. 4. Turn the device through 180° and mark point A3. The difference between points A2 and A3 is the tolerance for the X axis. 5. To check the Y and Z axis, repeat steps 3 and 4.
< 1 mm / 10 m = OK
A3
A2
A3

Alternatively the X- and Y-Axis can be changed with the button (SensoCommander).
In vertical mode the Z-Axis is automatically switched on.
and the previous status restored.
Save: The new calibration can be saved by pressing button (21) of the additional remote control or SensoCommander.
Alternatively the new calibration can be saved with the button (SensoCommander).

auto man

Self-levelling range + 5° Precision + 1 mm / 10 m
Horizontal / vertical levelling Automatic with electronic sensors and servo motors Self-levelling alignment time ca. 30 s Vertical reference beams 90° to rotation plane Rotation speed 0, 150, 500 RPM Remote control Infrared IR Laser wavelengths, green / red 635 nm / 532 nm Laser class red / green 2 / 3R (EN60825-1:2003-10) Laser output rating < 1 mW / < 5 mW Protection class IP 66
Rechargeable battery life red / green approx. 24 h / 16 h
Non-rechargeable battery life red / green approx. 35 h / 24 h (4 x type D)
Battery recharging time approx. 14 h
Working temperature range red / green -10°C ... +50°C / 0°C ... +45°C Weight 3,3 kg
1 x 9V Block / 1 x 9V Block / 1 x 9V Block 4 x type AA / 2 x type AAA
Battery life laser receiver approx. 70 h
Remote control range Commander 50 SensoCommander 310
max. 50 m max. 15 m
Laser reception range SensoLite 310 / SensoLite 120 SensoLite 200 / SensoCommander 310
Titanium red 300 m / 120 m 200 m / 300 m Laser reception range SensoLite 310 / SensoLite 120
Titanium green 200 m / 120 m Temperature range, operating / storage -10°C ... + 50°C / -10°C ... + 70°C
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.