FR
Laserliner logo
Notice d'utilisation officielle

Laserliner Flexi3D-Camera

92 pages·727 KB·Divers·PDF·EN
Laserliner Flexi3D-Camera
Table des matières 8 sections Flexi3D-Camera · Adjusting the camera head · Lock camera head · Focal depth · … AfficherMasquer
Page 1 of the Laserliner Flexi3D-Camera user manual
Page 1 · cliquer pour agrandir
Page 1

Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference. !

Function / Application The Flexi3D-Camera is a micro camera which can be connected to the Video- Control-Master base unit. Thanks to the small camera head and the twistable cable base with angle scale, the Flexi3D-Camera is ideal for the inspection of front and side areas. Working with a base unit, colour video images are sent to the LCD for inspecting all places that are difÖ cult to access such as cavities, air shafts, in masonry or motor vehicles.

Laserliner Flexi3D-Camera diagram (page 1)
Fig. 1

Connection to the base unit VideoControl-Master

Wheel for adjusting the camera

Camera head with 4 high-power LEDs

Knob for locking the camera head

Angle scale · Push rod · Control cable

Page 2 of the Laserliner Flexi3D-Camera user manual — < 2,5 cm
Page 2 · cliquer pour agrandir
Page 2

Flexi3D-Camera

Adjusting the camera head

Using the camera adjustment wheel (4), the camera head can be moved steplessly in two directions (Fig. 1). The cable base can be turned as well (Fig. 2).

Laserliner Flexi3D-Camera — Adjusting the camera head diagram (page 2)
Fig. 2 · Adjusting the camera head
Laserliner Flexi3D-Camera — Adjusting the camera head diagram (page 2)
Fig. 3 · Adjusting the camera head

Lock camera head

Laserliner Flexi3D-Camera — Lock camera head diagram (page 2)
Fig. 4 · Lock camera head

The camera head can be locked by turning the knob (3).

In order to avoid damage to the camera head, the lock must be disengaged when moving the push rod. !

Focal depth

The Flexi3D-Camera delivers sharp images in a range between 2,5 and 9 cm from the camera head.

2,5 - 9 cm

Objects well beyond the focus range may appear blurred.

< 2,5 cm

> 9 cm

Page 3 of the Laserliner Flexi3D-Camera user manual — Connection to VideoControl-Master
Page 3 · cliquer pour agrandir
Page 3

Connection to VideoControl-Master

Laserliner Flexi3D-Camera — Connection to VideoControl-Master diagram (page 3)
Fig. 5 · Connection to VideoControl-Master

The Flexi3D-Camera can be connected directly to the base unit VideoControl-Master. See image on right. Ensure that all contact pins are positioned correctly.

Connection with control cable

Use the supplied control cable as an extension or to work more × exibly. When screwing the control cable to the Flexi3D-Camera and the VideoControl- Master base unit on top, ensure that the arrow on the connector plug points toward the groove of the respective device.

Laserliner Flexi3D-Camera — Connection to VideoControl-Master diagram (page 3)
Fig. 6 · Connection to VideoControl-Master

The sensitive contact pins of the connector only fit into the socket in this position and can be damaged if not positioned correctly or used too forcefully. !

  • Instructions for use
  • It is absolutely vital to ensure that the Flexi3D-Camera does not come into contact with chemicals, current, moving or hot objects. This can damage the device and put its user at risk of serious injury.
  • The camera head is not acid-resistant or Ö reproof.
  • The Flexi3D-Camera must not be used for medical examinations / examining people.
  • The unit is not suitable for taking measurements close to dangerous voltages. Therefore always make sure that conductive parts are at zero potential when carrying out measurements in the vicinity of electrical systems. Safe isolation from the power supply and precautions to prevent systems being switched on again must be ensured by implementing suitable measures.
  • Clean the push rod with a damp cloth before placing it in the case.
  • The camera must not be operated when the push rod is rolled up.

Direct connection

Page 4 of the Laserliner Flexi3D-Camera user manual — Flexi3D-Camera
Page 4 · cliquer pour agrandir
Page 4

Flexi3D-Camera

Technical dataSubject to technical alterations. 08.13. Type of cameraCMOS image sensor Camera headø 5,5 mm, water-resistant Protection classIP 67 (immersion depth 1 m, 30 min.) Camera resolution640 x 480 pixels Field of vision65° Focal depth2,5 ... 9 cm Cable diameter5,5 mm Cable length1 m / 2 m Minimum bending radius70 mm Operating temperature-10 … 60°C Storage temperature-20 … 70°C Weight0,48 kg (1 m) / 0,56 kg (2 m)

EU directives and disposal This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: www.laserliner.com/info

Poser une question sur : Laserliner Flexi3D-Camera

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Laserliner Flexi3D-Camera

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Laserliner Flexi3D-Camera manuel PDF

92 pages·727 KB·Divers·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…