NOTICE The shorter the hose length and the larger the hose di- ameter, the higher the pump capacity. To prevent clogging of the pump, use a prefilter with hose diameters of less than 1¼ “ (see special accesso- ries). The pump connection is equipped with a plug system (Quick-Connect). The unmounted connection nozzle is enclosed in the device. Illustration To remove the connection nozzle, press the Quick- Connect (grey button). Illustration Slide the hose clamp onto the hose. If a ¾“ or 1“ hose is used: Screw pump connecting piece (see special acces- sory) onto the connection nozzle. Slide the hose onto the pump connecting piece and secure it by means of a hose clamp. Slide the connection nozzle into the Quick-Connect. If a 1¼ “ hose is used: Slide the hose onto the connection nozzle and se- cure by means of a hose clamp. Slide the connection nozzle into the Quick-Connect. Illustration Folding the support legs in and out (SP 2 Flat - see operation). Safely place the pump on a stable surface in the feed fluid or immerse it using a rope tied to the car- rying handle. NOTICE The suction area must not be blocked by soiling. In case of muddy ground, place the pump on a brick or the like. Ensure that the pump is level. Do not carry the pump on the cable or the hose.
Illustration Fold out the support legs (SP 2 Flat) for the pump start if necessary. NOTICE It is not mandatory to fold out the support legs; a higher pump capacity is achieved by folding out the support legs. Illustration NOTICE In the automatic mode, the float switch controls the pumping operations automatically . The pump switches on as soon as the float switch has reached the switch-on height due to the rising fluid level. The pump switches off as soon as the float switch has reached the switch-off height due to the falling fluid level. Ensure that the float switch is not obstructed in any way.
For switch-on height / switch-off height see the following table:
Min / Max SP 1 Dirt SP 2 Flat SP 3 Dirt Switch-on height cm*
43 / 50 36 / 44 43 / 50
18 / 30 15 / 24 18 / 30
*The switching height can vary depending on the posi- tion of the float switch. Insert the mains plug into the socket.
Illustration Fold in the support legs (SP 2 Flat) for the pump start. NOTICE By folding in the support legs the flat vacuuming of the fluid up to a residual fluid height of 1 mm becomes pos- sible in manual operation. Illustration Secure the float switch pointing upwards in the lock. NOTICE In manual operation the pump remains switched on continuously. In order that the pump draws independently in manual operation, the fluid level must be at least 60 mm (SP 1 and 3 Dirt) or 7 mm (SP 2 Flat). The pump can pump up to a residual fluid height of 25 mm (SP 1 and 3 Dirt) or 1 mm (SP 2 Flat). The stated residual fluid height is only achieved in man- ual operation. Insert the mains plug into the socket. ATTENTION Risk of damage! Dry running leads to increased wear; never leave the pump unattended during manual oper- ation. Switch off immediately in case of dry running.
DANGER Risk of mortal danger on account of electric shock! Do not touch feed fluids, the rope attached to the carry- ing handle as well as objects that are in contact with the feed fluid (e.g. pipelines extending into the water, rail- ings, etc.).
Illustration With a low fluid level, possibly drawn air or air that is present in the pump escapes via the automatic venting device. In addition, fluid may leak at this spot. If the pump has suction problems with a low fluid level, unplug and plug in the mains plug repeatedly in order to support the suction process.
Switch-off height cm*

Storage
The pump is maintenace-free.
CAUTION In order to prevent accidents or injuries, keep in mind the weight of the appliance when selecting a storage lo- cation for it (see Specifications).
CAUTION In order to prevent accidents or injuries, keep in mind the weight of the appliance during transport (see Spec- ifications). Lift and carry the pump on the carrying handle. If you want to transport the appliance on a vehicle secure it from slipping.
Completely drain the pump and allow it to dry. Store the pump in a frost-free place.
2.997-100.0 Braided hose set Flexible 1 1/4“ braided hose with hose clamp (30 - 40 mm) with wing screw for a connection without tools. Especially recommendable for the immersion pumps when remov- ing large water quantities. Max. operating pressure: 5 bar 2.997-201.0 Prefilter for immersion pump, small
The robust prefilter is easy to attach and protects your immersion pump, which increases the functional reliability. 6.997-359.0 Pump connection G1 (33.3 mm) incl. Check valve
For pumps with G1 (33.3 mm) connection thread and 3/4" as well as 1" hoses, including union nut, hose clamp, flat packing and check valve. 6.997-347.0 Spiral hose, by the meter, 25 m, 3/4" By the meter for cutting hoses to individual lengths.
6.997-346.0 Spiral hose, by the meter, 25 m, 1" By the meter for cutting hoses to individual lengths.
2.645-142.0 Hose PrimoFlex, 25 m, 3/4" Phthalate-free 3/4" garden hose for draining away the water. 2.645-247.0 Hose PrimoFlex, 50 m, 1" Phthalate-free 1" garden hose for draining away the water.
DANGER Risk of mortal danger on account of electric shock! To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorised customer service personnel.
Fault Cause Remedy Pump runs but does not transport Air in the pump Unplug and plug in the mains plug of the pump repeatedly until the fluid is drawn Suction area blocked Pull out the mains plug and clean the suction area (only in manual mode) Water level be- low the minimum water level
Immerse, whenever possible, the pump deeper into the feed fluid or proceed as described in Chapter Operation. Pump does not run or suddenly comes to a standstill during operations
Power supply interrupted Check fuses and electrical connections Thermal protection switch has switched off the pump due to over- heating
Pull out the mains plug, let the pump cool down, clean the suction area, prevent dry running Dirt particles have got jammed into the suction area
Pull out the mains plug and clean the suction area The float switch stops the pump Check position of float switch. Pumping capacity is reducing Suction area blocked Pull out the mains plug and clean the suction area Pumping capacity too low The pumping capacity depends on the flow height, hose diameter and hose length.
Observe the maximum delivery height, see technical data. If neces- sary, use a larger hose diameter or a shorter hose length. Quick-Connect cannot be opened or closed.
Soiling in the plug system. Remove and clean clip.

SP 1 Dirt SP 2 Flat SP 3 Dirt Voltage V 230 - 240 V 230 - 240 V 230 - 240 V Current type Hz 50 50 50 Output Pnom W 250 250 350 Max. flow rate l/h 5500 6000 7000 Max. pressure bar 0,45 0,5 0,6 Max. flow height m 4,5 5 6 Max. immersion depth m 7 7 7 Max. grain size of the dirt particles that can be transported
mm 20 5 20
Minimum fluid height (manual mode) mm 60 7 60 Residual fluid height mm 25 1 25 Weight (without accessories) kg 3,7 3,7 4,2
Subject to technical modifications!

The possible delivery rate is even larger: – the lower the delivery height – the larger the diameter of the hose used – the shorter the hose used – the lower the pressure loss caused by the connected accessories