Thank you for choosing a GUTMANN extractor hood.
Please read the following information and explanations regarding the proper use of your new GUTMANN hood model carefully before using for the first time. Please also observe our cleaning recommendations so that your new device will enjoy as long a service life as possible.
Dear customer,

The extractor hood may never be operated without the grease filter and must always be used under supervision. Filters that are overfilled with grease can represent a fire hazard! Keep the extractor hood under constant supervision when deep-frying! Please make sure that the grease filter is cleaned regularly. Flambéing under the extractor hood is not allowed! Gas appliances may only be used under the extractor hood with saucepans being on them! If you use more than 3 gas-fired hot plates at once, please operate the extractor hood at level 2 or higher. This avoids an accumulation of heat in the appliance.
These operating instructions contain important information that must be heeded to enable the extractor hood to be operated without danger or malfunctions. Keep the operating and installation instructions in a safe place for future reference.
The extractor hood may only be used for the extraction of kitchen vapours above the cooking appliances in private households. Any other use will be deemed to be improper. Danger to persons and objects may result from improper use of the hood.The extractor hood may not be used as a shelf for depositing objects such as e.g. bottles or herbs or other loose items.
Do not clean the hood with a steam jet or water pressure cleaner. The hood must be disconnected from the power supply prior to cleaning. This appliance is not intended for use by persons (including children) with restricted physical, sensorial or mental capabilities or with a lack of experience or knowledge, unless they are supervised by a person responsible for safety or have received instructions from that person as regards the use of the appliance. Children must be supervised to ensure that they do not play with the appliance.
The device may only be installed and connected by an authorised technician observing all relevant regulations of the po- wer supplying companies and Building Re- gulations of the Federal States. Please observe the assembly instructions during installation! Damaged appliances may not be put into operation. Defective parts must be replaced by original ones. Repairs may only be carried out by authorised technical staff.
Subject to technical alterations!!
If the extractor hood is operated in extraction mode in one room together with other room air dependent firing installations (e.g. wood, gas, oil or coal-fired appliances), lethal combustion gases may be redirected into the room due to an occurring negative pressure. The operator must therefore provide a sufficient air supply at all times. The negative pressure in the room must not exceed 4 Pa (0.04mbar).
The extractor hood has been especially developed for the extraction of cooking vapours in private households where the hood is installed in bottom cupboard units. Rising cooking vapours are captured by the extractor hood and extracted via metal filters.
The metal filters are fastened to the filter mounting and can be replaced without tools. The metal filters are high-quality aluminium filters with several knit-work filter mats that ensure good grease extraction.
Fire hazard! · Intended use · Installation

The lighting system consists of several ha- logen lighting units, which are positioned symmetrically and sunk in the filter mounting, thus centrally illuminating the hob.
The hood body is made of noble, easy-to- clean materials such as stainless steel.
The suction power and the lighting of the hood are controlled via a membrane keypad. Information about the operating condition of the hood is provided by the LEDs in the operator panel.
Switching the fan ON/OFF Press membrane key 1 to switch on. To switch the fan off from each level, press membrane key 1 twice.

Fan power The fan power is controlled by repeatedly pressing arrow keys 4 or 5. The individual levels must however be switched one after another. 12 different power levels can be selected.
Fan operation faster: press membrane key 5.
Fan operation slower: press membrane key 4.
Automatic follow-up time (1) To switch on the follow-up time press membrane key 1. The device switches back to level 1 within a sort time and then switches off altogether after approx. 15 minutes.
Switching on the lighting (6) To switch the lighting ON or OFF, press membrane key 6. The lighting is dimmed by pressing this key again. A long press on membrane key 6 is required to increase brightness.
Filter cleaning indicator (3) After approx. 15 operating hours or 14

The functions of the hood model and the fan power of the external motor can be controlled via three alternative procedures:

operating days, the red LED in the membrane keypad begins to light up (even if no cooking takes place). This indicates that the grease filter needs changing. After cleaning the grease filter, press membrane keys 4 and 5 simultaneously until the red LED goes out. The operating hours counter is then reset.

Indication mode LEDs lighting up in clockwise direction indicate the power level of the fan.
Switch over to rotary LEDs by pressing membrane keys 4 and 5 simultaneously.
Pressing the switch to the left: Light ON/OFF
Pressing the switch to the right: Fan power control
Pressing the switch to the right for 3 seconds: hood switches off.
The filter saturation indicator is also reset via this switch. To do so, please press the right side of the switch until the red LED goes out.



(see also separate operating instructions)
Function 2 – follow-up time (activation of the follow-up time by pressing button 1 again; the ceiling unit automatically switches down by one level as a result within a short time until it finally switches off altogether)
Details regarding the operating status of the hood can be read off at the LED display of the device.
Button 3: Intensive level (motor automatically switched back to level 3 after 3 minutes).

When the red LED lights up the metal filters must be cleaned (see section on cleaning and care). The filter saturation indicator lights up after max. 15 operating hours or every 14 days (even if no cooking has taken place).
Level 1 green LED
Level 2 green LED
Level 3 green LED
Intensive level green LED
Filter saturation indicatorred LED
(the hood automatically switches down by one level at a time within a short time until finally switching off altogether)
Only use conventional detergents or univer- sal cleaning agents for cleaning suitable for stainless steel/aluminium and glass. Never use abrasive cleaning agents or steel wool. After cleaning the hood, please treat the stainless steel surfaces with a care product for stainless steel.
LED 2:Fan power level 1 (low motor power)
Press button 2 of remote control once
Only clean painted surfaces with soapy water and a very soft cloth.
Clean the glass front (halogen) with a conventional glass cleaner and wipe with a soft cloth.
Press button 2 of remote control twice
Fire hazard! The performance of the extractor hood is reduced by grease residues and the fire hazard increases. In order to prevent a fire hazard, please make sure to clean the metal filter regularly (see „Grease filter cleaning indicator“). Clean the filters every two weeks at the latest.
Press button 2 of remote control three times
Grip the metal filter by the handles with both hands and pull down until the magnet contact releases. The metal filter can now be removed downwards. Installation takes place in reverse order.
Press button 3 of remote control
Follow-up green LED


The metal filter is best cleaned in the dishwasher using a gentle dishwashing agent.

The manufacturer shall not assume any guarantee whatsoever for any discolouration caused by the use of aggressive dishwashing agents. Temperatures exceeding 65 degrees must be avoided in all cases.
Use a clean cloth to touch the bulb. Do not
touch the bulb with your bare hands.
Re-insert the metal filter after cleaning and turn in clockwise direction to tighten using both hands.
Activated carbon, see separate instructions!
whether the bulbs have been properly inserted.

Disposal
Please contact our service department
immediately, if:
- the extractor hood causes indefinable
The packaging of the device is recyclable. Cardboard and polyethylene film (PE) are used as packaging materials. These materials must be disposed of in accordance with the respective environmental regulations valid at the place of use.
noises and you are unable to detect any faults after checking the exhaust line;
- you establish that the motor is faulty or
defective e.g. by hearing strange noises;
- the switches are not working properly.
Please make sure to state the type of your
extractor hood model and the corresponding serial number. You will find this information on the type plate. This plate is located inside the hood near the filters.
Your municipal authority will advise you as to the environmentally compatible disposal of used household appliances.
This device is marked in accordance with the European Directive 2002/96/EC regarding waste electrical and electronic equipment (WEEE). The directive specifies the framework for a Europe-wide return and disposal of used appliances. Please ask your dealer for information about current disposal methods.
Packaging · Extractor hood