6.1 Time and day of the week 6
6.2 Calendar month and day 7
6.2.1 AU = Automatic changeover 7
6.2.2 cHA = Weekday-related time change 8 - 9
6.2.3 no = no changeover 10

2.3 Connection See information on the unit! Press any key to activate the time switch • the time and date is displayed Note: If no key is pressed the time switch is automatically activated after approx 1 - 2 minutes.

Set time, end program input
Select day(s) of the week
Set minutes, month, year
Set hours, day, year
Summer time/winter time switchover
1234567 = days of the week
Hours - current time Calendar day - current date
summer time Minutes - current time Month - current date - start/end
Channel 1 Channel 2
summer time Year - day/month

5 5. Factory setting
The selections correspond to Central European Time. The time switch offers 3 Operating modes. The date and time, and also the Operating mode AU are set.
Operating modes: • AU Automatic summer time controller switchover see 6.2.1 The switchover occurs on the dates defined by the legislator.
AM/PM switch-over Switch clock is in current operating mode 1. Press h and keep pressed 2. – Press Res once – all segments are displayed – after approx. 1 second the following appears:
AM, 12.00 and 3 (Wednesday)
Operating mode AU is active = works setting

6 6. Changing settings
6.1 Time and day of the week
no = no change
- see 6.2.3
was selected, the day of the week must now be set. With the Day 1 - Monday key select: 2 - Tuesday 3 - Wednesday : 7 - Sunday

7 6.2 Calendar month and day – Select the Operating mode
6.2.1 AU or 6.2.2 cHA or 6.2.3 no
6.2.1 AU = Automatic changeover
Press the + 1h key 1 once, AU appears
Press the Prog key once
Confirm with the Prog key
Set the current month and day:
With the m key – calendar month With the h key – calendar day Note:
With the Prog key (press once or twice), read the date for the start e.g. 29.03. and end e.g. 25.10. of summer time.

8 6.2.2 cHA = Weekday – related time change
Press the + 1h key as often as necessary until cHA appears
Press the Prog key once
Confirm with the Prog key
Set the current month and day:
With the m key – calendar month With the h key – calendar day

Confirm with the Prog key The start of summer time is displayed.
Set the individual summer time start: With the m key – month With the h key – day
Confirm with the Prog key

6.2.3 no = no changeover – only weekly time switch
Press the + 1h as often as necessary until no appears. The time switch operators without a date!

11 7. Standard switching commands
Select free memory location: Press the Prog key as often as necessary until – –:-– – appears.
Set the switching times: With the m key – minutes With the h key – hours For weekday adjustment, see:
Block formation of weekdays, Point 8
The switching state for CH1 or CH2 can be deactivated. No symbol – no switching.
Press the Prog key once. The input has ended. A free memory location is displayed – for other settings or
Press the key once. The input is ended. The display shows the current time.
(ON) or (OFF)

12 8. Fixed weekday block formation – only weekly time switch
Defined combinations of weekdays or individual days
You determine the weekdays for your switching program. 1 - Monday, 2 - Tuesday, 3 - Wednesday ..., 7 - Sunday
Press the Day key once All 7 days of the week are activate
1 2 3 4 5 6 7 –

Press the Prog key once. The input is ended. A free memory location is displayed - for further settings or press the key 1once. The input is ended. The display shows the current time.

Press the Prog key step by step as far as the switching command/contents which you want to change/overtype. Change the switching command/ contents: As described in 8. Weekday block formation
Delete - individual switching commands
Press the Prog key step by step as far as the switching command/contents which you want to delete.
Press the Clear key once. This switching command is deleted.
Read · Change

Delete - All switching commands
Press the Prog key as often as necessary until FRxx appears
Press the Clear key once. CL is in the display
Press the Clear key and hold it down. All memory locations are deleted!
The display shows the number of the max. memory locations.
Press the Reset key once
The set date and time are reset.
The factory setting AU = automatic s/w- time changeover is active (31.12.1997, 00:00)
All segments are visible for approx. 2 seconds, then 00:00 appears.
AU = automatic s/w time
changeover See point 5 and 6 for setting the current date.
Reset

You change – manually – the current switching state. However, the individually set switching program is preserved.
1 for channel 1 2 for channel 2
FIX = continuous operation
= ON
FIX = Continuous ON
= OFF
FIX = Continuous OFF
The switching state corresponds to the entered program.
You change – m a n u a l l y – the current switching state. The next switching command in the program is executed automatically again.
You change – m a n u a l l y – the current switching state. Only with the key do you switch from continuous operation back to Automatic mode.
= automatic · = Manual mode

17 11. Technical data
1 channel daily program
1 channel weekly program 2 channel weekly program
Dimensions (H x W x D) mm Distributor cut-out mm Weight g (approx.) Connection Power consumption: Switching capacity at 230 V AC – ohmic load (VDE, IEC) – inductive load cos ϕ 0,6 – glow lamp load Switching output Switching contacts Protection class Protection type Running accuracy DCF 77 radio operation Running reserve type Running reserve Shortest switching time Programmable Memory locations Switching preselection Hand switch
45 x 36 x 60 46 x 36 170 see unit imprint see unit imprint
45 x 36 x 60 46 x 36 170 see unit imprint see unit imprint
16 A/250 V AC 2,5 A/250 V AC 1000 W potential-free 1 or 2 changeover contacts II IP 20 ± 2.5 s/day at +20° C – Lithium 3 years from factory 1 minute every minute 12 yes Automatic/preselection Fix ON Fix OFF yes – automatic/freely selectable captive +/– screw terminals - 25° C … + 55° C yes
16 A/250 V AC 2,5 A/250 V AC 1000 W potential-free 1 or 2 changeover contacts
± 2.5 s/day at +20° C – Lithium 3 years from factory 1 minute every minute 20/30 yes Automatic/preselection Fix ON Fix OFF yes fixe assignment automatic/freely selectable captive +/– screw terminals - 25° C … + 55° C yes
Switching state display Block formation of weekdays Summer/winter time switchover Connection type Ambient temperature Led sealable
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.