The smoke alarm alerts you early and reliably to an accumulation of fi re smoke, and gives you and your family plenty of time to escape to safety.
This is of particular importance at night because when asleep we are not able to smell fi re smoke, and so are exposed to the toxic gases generated by fi res.
During this phase, the smoke alarm gives you a head start to escape the room safely.
Experience has shown that smoke alarms save lives.
In this respect, please also follow our instructions on using our product properly.
Delivered with the smoke alarm (including base) are this operating guide, the leafl et with important information, a permanently installed battery, a replaceable battery, 2 screws and dowels for attaching the alarm, and an adhesive pad.

The smoke alarm is fi tted to the ceiling of the room. Fitting it in the centre of the room gives the smoke alarm its optimum detection characteristics.
-JWJOHSPPN
To provide minimum protection, smoke alarms must be installed in bedrooms, children’s rooms and landings/hallways so you are woken up when an alarm is raised.
In multi-storey buildings, at least one additional smoke alarm should be positioned in the hallway on every fl oor.
,JUDIFO
If a smoke alarm is connected to a Gigaset elements base, the maximum range for DECT wireless transmission is 50 metres (indoor).
$FMMBS
= MINIMUM PROTECTION
= SPECIAL PROTECTION
Multi-room fl at · House

FOR INCLINED OR POINTED ROOFS For installation to inclined or pointed ceilings, and rooms with an inclined ceiling, smoke alarms should be installed at least 10 cm vertically underneath the highest point, and no more than 90 cm horizontally from the highest point. These distances also apply when multiple alarms are installed in one room. Install individual smoke alarms at appropriate distances from each other.

CEILING INSTALLATION When fi tting smoke alarms to the ceiling, keep a distance of at least 50 cm from a wall.
ANGLED CEILING In rooms having a ceiling at an angle greater than 7 degrees (corresponds to a height diff erence of about 50 cm over 4 m), smoke alarms should be positioned on the ceiling in the higher part of the room.
10cm · 90 cm

The smoke alarm is delivered with a permanently installed battery and a replaceable battery. No rechargeable batteries or mains adapters are required to provide power. Only insert the following batteries: Lithium Primary 3.0 Volt (CR2). Batteries with visible damage must be replaced.
MEDICAL DEVICES The functioning of medical devices can be aff ected. Bear in mind the technical conditions of the environment in question (such as a doctor’s surgery).
If you use medical devices (such as pacemakers), please fi nd out from the device manufacturer the extent to which the devices in question are immune to external, high-frequency energy.

DO NOT SPRAY OR PAINT OVER AN ALARM Smoke alarms may not be coated with paint.
INSTALLATION IN ROOF GABLES Installation in roof gables is only permitted when they are fi tted in line with “Installation position for inclined roofs”.

DISTANCE FROM LIGHTS Keep a distance of at least 50 cm between lights and smoke alarm installation position.
FOR INDOOR USE ONLY Smoke alarms are only permitted for indoor use.
People have a reduced perception of fi re and fi re smoke especially when asleep. Smoke alarms provide an early warning so that speedy reactions are possible. Smoke alarms do not provide protection from material damage.

BEAR IN MIND THE ENVIRONMENT Do not use the devices in potentially explosive environments, such as paint shops.
DISPOSAL Do not throw (rechargeable) batteries out with household waste. For this, observe local waste disposal regulations (available from your local authority).
In Germany: Dispose of these in the green “Gemeinsame Rücknahmesystem Batterien” (Collective return system for batteries) boxes provided at specialist retailers.

All electrical and electronic devices must be disposed of at local authority sites (separate from general household waste).
If a product displays the symbol of a crossed-out rubbish bin, the product is subject to European Directive 2012/19/EU.
Proper disposal and separate collection of used equipment help to prevent potential harm to human health and the environment. They are prerequisites for the reuse and recycling of used electrical and electronic equipment.
Consult your local authority or waste disposal fi rm for more comprehensive information on disposal of your old devices.

SMOKE ALARMS MAY NOT BE AFFIXED AT THE FOLLOWING PLACES:
DISTANCE FROM WATER VAPOUR Rooms in which high levels of water vapour are generated under normal conditions (e.g. kitchen, bathroom/toilet)
DISTANCE FROM FIREPLACES Near fi replaces and open fl ues
TEMPERATURE RANGE Rooms having temperatures lower than -10°C or higher than +60°C
DO NOT POSITION IN DRAUGHTS Near ventilation shafts (e.g. of air-conditioning or recirculation air system)


Look for the small red registration button. Bring smoke into the immediate vicinity

of your base. Start the Gigaset elements app. In the app, open the system overview
, and select "Add + smoke”, then follow the instructions on the screen. Smoke is then connected to Gigaset elements
and is shown in the system overview of the app.

Within reach of base (max. 50 m). If possible, in the middle of the room, with a minimum
distance of 50 cm away from live wires. Check that no live wires run across the installation
location and keep a minimum distance of 50 cm from walls and lights.
Use adhesive pads for installation if you do not want to
drill. For information on installing with adhesive pads see: "Optional accessory"

You can use the lower part / base of the smoke alarm
as a template.

All-is-good

Acoustic signal Red LED Function / Meaning
No sound Flashes every
344 seconds Normal state, automatic self-test
every 0.5 seconds
0.5 seconds Alarm state
every 40 seconds OFF Battery change display, please renew the alarm
3 short signal sounds every 40 seconds OFF Fault/dirt, please renew the alarm
No sound Flashes every
10 seconds Alarm muting
Flashes every 0.5 seconds whilst the face of the alarm is

The smoke alarm is in place The smoke inlet openings for coarse dirt (dust, paint) The smoke alarm for mechanical damage
A damaged smoke alarm must be replaced immediately.
The smoke alarm is working correctly.
Alarm muting has no function when the smoke alarm is tested with test aerosol.

The state building codes in some federal states stipulate that owners of houses and fl ats are responsible for ensuring that smoke alarms are installed and function correctly. Maintenance must be performed at least once a year and comprises (according to DIN 14676) a visual inspection and function/alarm test. A function test must be performed following a longer period of absence, but no later than after a year.
Replace all smoke alarms after 10 years at the latest. The recommended date for replacement is on the label in format month/year. Smoke alarms can be stored for a maximum period of 2 years before being used.
Wipe the device with a damp or antistatic cloth. Do not use solvents or microfi bre cloths. Never use a dry cloth as this can cause static charging.

When an alarm is raised, alarm muting can be activated by pressing the face of the alarm. This reduces the response sensitivity of the alarm / increases its activation threshold. The alarm is muted if the smoke concentration in the smoke chamber is below the increased activation threshold after the face of the alarm is pressed. If the smoke concentration is still above the increased activation threshold, muting is not activated until the smoke concentration drops below the increased activation threshold. The smoke alarm is muted. The smoke alarm returns to normal mode after about 10 minutes.

This function is especially useful at night. Press the test button on the face of the alarm to suppress the fault signal for about 8 hours when a battery fault occurs. After this time, the battery fault signal is sounded again and you are reminded to replace the smoke alarm.
the face

CNBOP-PIB APPROVED ADHESIVE PAD The smoke alarm base can be attached to the ceiling using the screws and dowels supplied or with the dual-sided adhesive pad. For order request, please contact the Gigaset customer service www.gigaset.com/service
When using the adhesive pad to fi t the alarm, note the condition of the surface in question to guarantee secure adhesion of the smoke alarm. Best possible adhesive force is only attained with clean surfaces. Before using the adhesive pad, carefully check that the condition of the surface used is suitable for permanent bearing and bonding of the weight (carry out test adhesion as required).
For installation, pull the protective fi lm from one side of the adhesive pad and stick it onto the middle of the base of the smoke alarm. Next, remove the protective fi lm on the other side and press the base fi rmly to attach it to the ceiling. Then continue with the installation as described in section “Installation and use”.

Only stick the sensors onto clean, dry, grease-free surfaces which are as smooth and
sturdy as possible. The optimal adhesive strength is attained after about 48 hours. The adhesive strips are intended for one-time use only. Only use the adhesive strips provided. Gigaset Communications GmbH assumes no liability for potential damage to surfaces caused by sticking on, setting up, installing and removing Gigaset elements sensors and actuators.
A plastic anti-tamper seal can be affi xed to the smoke alarm to prevent unauthorised removal.
Instead of this seal, a safety screw can be fi tted to prevent unauthorised removal of the smoke alarm.
The seal and screw are not included in the delivery and can be ordered separately. Please contact the Gigaset customer service www.gigaset.com/service


Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.