PUBLISHED BY Gallagher Group Limited 181 Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand
www.gallagherams.com Copyright© Gallagher Group Limited 2008 All rights reserved. Patents pending.
Gallagher M150 / M200 / M300 / M500 Mains Powered Energizer User Manual
3E0682 - EdiƟ on 8 - November 2012
DISCLAIMER: Whilst every eff ort has been made to ensure accuracy, neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or acƟ ons they may make as a result of using this informaƟ on. In accordance with the Gallagher policy of conƟ nuing development, design and specifi caƟ ons are subject to change without noƟ ce. Developed and manufactured by Gallagher Group Limited, and ISO 9001 2000 CerƟ fi ed Supplier.





WARNING: Read all instruc Ɵ ons

Minimum clearances from power lines for electric animal fences

SERVICE OF DOUBLE-INSULATED APPLIANCES In a double-insulated controller, two systems of insulaƟ on are provided instead of grounding. No equipment grounding means is provided in the supply cord of a double-insulated controller, nor should a means for equipment grounding be added to the controller. Servicing a double-insulated controller requires extreme care and knowledge of the system, and should be done only by qualifi ed service personnel. Replacement parts of a double insulated controller must be idenƟ cal to the parts they replace. A double insulated controller is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED”. The symbol for double insulaƟ on may also be marked on the appliance.


Output Terminal: Connects to Fence
M500: This energizer complies with the requirements for a Ɵ me delayed electric fence energizer with a Ɵ me delay of 15 seconds.
Green light constant- Normal operaƟ on
The output voltage bargraph will pulse with every energizer pulse. Each colour segment gives an approximate indicaƟ on of the fence performance. The bargraph is read in the following manner:
Use this bar graph for quick indicaƟ on of your energizer and Fence performance.
Green Yellow Red



Mount the energizer on a wall, under cover or inside, out of reach of children. Install where there is no risk of the energizer incurring fi re or mechanical damage and if possible away from heavy electrical equipment eg. pumps or other items that may cause electrical interference.

a) Using the template on the back page, drill 2 x 4mm (5/32”) holes (A & B).
b) Fix the screws provided into the wall leaving the head of the screw about 3mm (1/8”) out from the wall.

c) Place the energizer over and slide down onto the mounƟ ng screws.

5 Wire Ɵ ghtener
9 Cut out switch

a) Using Underground Cable (G6270) remove 5cm (2”) of plasƟ c coaƟ ng from one end of the cable and connect to the green terminal on the energizer.
b) AƩ ach the cable to the earth system by removing 10cm (4”) of insulaƟ on from the cable at each Earth Stake (G8790), then clamp the exposed wire to each stake using an Earth Clamp (G8760).
c) Tighten the clamp.
a) Connect the energizer’s red output (
) terminal to the fence using Underground Cable (G6270).
b) AƩ ach the other end of the cable to the fence using a Joint Clamp (G603).
a) Plug the energizer into a power outlet and switch ON.
b) Check that the Power On LED on the front of the energizer is green.
Find a locaƟ on for your earth system that is permanently damp, has high ferƟ lity or salinity and is away from dairy sheds. Install the earth system at least 10m (33Ō ) from any power supply earth peg, underground telephone or power cable.

The best construcƟ on is 2m (61/2Ō ) long galvanised stakes G8790 or Super Earth Kits G8800, 3m (10Ō ) apart, connected to the energizer by high quality Lead-out cable G6270. Do not use materials that rust. (Use G6272 if the earth system is over 100m (300Ō ) from the energizer).


Improperly earthed energizers can cause barns, gates etc to become hot. Follow earthing instrucƟ ons carefully.
The most eff ecƟ ve place for an earth system is in conƟ nuously damp soil (illustraƟ on a).

The animal must touch the wire and the ground to feel a shock
For dry areas with poor earthing condiƟ ons, install the fence using illustraƟ on b.

The animal must touch both a live wire and the earth wire to feel an eff ecƟ ve shock
Earth stakes, at least 2m (6Ō ) long, should be spaced 3m (10Ō ) apart. Use a minimum of 3 earth stakes for the M150, M300, M500.

Use Cut-out Switches (G6076) to allow secƟ ons of the fence system to be switched off during fence maintenance. Put a switch at each gateway and at every major change in fence direcƟ on.


These fi gures are guidelines only for fl at country condiƟ ons.
Post spacing 20 - 25 m (60 - 75 ft)
Post spacing 20 - 25 m (60 - 75 ft)
Post spacing 20 - 30 m (60 - 90 ft)
Post spacing 20 - 30 m (60 - 90 ft)
Post spacing 8 - 10 m (25 - 30 ft) Post spacing 15 - 30m (45 - 90 ft)
Post spacing 6 m (20 ft) Post spacing 15 m (45 ft)
150mm (6”) 150mm (6”) 150mm (6”) 150mm (6”) 150mm (6”)
For wire and post spacings in dry areas with poor earthing condiƟ ons, see your Gallagher dealer.
When joining wires under tension, use a fi gure eight or reef knot.

Do not use copper wire anywhere in your fence system.

Gallagher dealers off er a complete range of products for your Power Fence. For fence specifi caƟ ons and design contact your Gallagher dealer.
On permanent Power Fencing, use high tensile, 12.5 gauge wire. Do not use barbed wire or 16 or 18 gauge wire. On portable fences, Polywire, Polytape or light gauge wire may be used.