1. Introduction

We thank you for the purchase of this product.

This product complies with the statutory national and European requirements. In order to maintain the condition and to ensure a hazard free operation, you-the user-must comply with this operating manual!

Please read this complete operating manual prior to operating the product and comply with all operating and safety instructions.

All company names and product names are trademarks of their respective owners. All rights reserved.

In case of technical questions please contact:

GermanyPhone: + 49 9604 / 40 88 80
Fax+ 49 9604 / 40 88 48

Mon. to Thur. 8.00am to 4.30pm, Fri 8.00am to 2.00pm

2. Scope of delivery

  • Air-conditioning unit
  • Remote control
  • Flexible exhaust hose
  • Adapter for exhaust hose
  • Extendable window guide (inner/outer part)
  • 6 x crosshead screws

Dear customer,

Page 2 of the Conrad 8000 BTU user manual — 4. Explanation of symbols
Page 2 · cliquer pour agrandir
Page 2

3. Intended use

The mobile air-conditioning unit is designed to cool, ventilate, and dehumidify interior rooms. Always place the product on a level, sturdy, and dry surface.

The device is designed for domestic use. The product is not suitable for commercial use.

It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bathrooms, must be avoided under all circumstances.

The manufacturer does not accept any responsibility for damages caused by improper use. Use only original accessories. Use the device only as described in this operating manual. Any other use may cause damages on the device or injuries.

For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you use the product for purposes other than those described above, the product may be damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and keep them. Make this product available to third parties only together with its operating instructions.

4. Explanation of symbols

The triangle containing a lightning symbol warns against danger of electric shock or impairment of the electrical safety of the device.

An exclamation mark in a triangle indicates important notes in these operating instructions that must be strictly observed.

The „hand“ symbol indicates special information and advice on operation.

Page 3 of the Conrad 8000 BTU user manual — a) Mobile air-conditioning unit
Page 3 · cliquer pour agrandir
Page 3

5. Operating elements

a) Mobile air-conditioning unit

Conrad 8000 BTU — a) Mobile air-conditioning unit diagram (page 3)
Fig. 1 · a) Mobile air-conditioning unit
Page 4 of the Conrad 8000 BTU user manual — c) Remote control
Page 4 · cliquer pour agrandir
Page 4

b) Operating panel

14 15 16 17 18 19 20 21 22 23 24

Conrad 8000 BTU — b) Operating panel diagram (page 4)
Fig. 2 · b) Operating panel

25 26 27 28 29 30 31 32

c) Remote control

Conrad 8000 BTU — c) Remote control diagram (page 4)
Fig. 3 · c) Remote control
20. Indicator light SLEEP
21. Indicator light COOL

3 Rear air filter

22 Indicator light DEHUM

4 Air exhaust openings (adjustable

23 Indicator light FAN

24 Indicator light POWER

5 Side air filter

25 Key (on/off switch)

6 Power plug storage

26 Key (select operating mode)

7 Power cord with power plug

27 Key (sleep mode)

28 Key (reduce value)

9 Wheels (not shown)

29 Key (increase value)

10 Extendable window guide

31 Key (fan speed)

11 6 x crosshead screws

12 Flexile exhaust hose

13 Adapter (for exhaust hose)

34 Key (select operating mode)

14 Indicator light W.F

36 Key (on/off switch)

15 Indicator light COMP

37 battery compartment (rear)

16 Indicator light HIGH

38 Key (reduce value)

17 Indicator light LOW

39 Key (sleep mode)

18 Indicator light TIMER

40 Key (fan speed)

41 Key (increase value)

Show 11 more labels / short text on this page
1 Handle · 2 Operating panel · verticality/horizontally) · 8 Exhaust opening · 30 Key (timer) · (inner/outer part) · 32 IR receiver · 33 IR sender · 35 Key (timer) · (water tank full) · 19 Display
Page 5 of the Conrad 8000 BTU user manual — a) People / Product
Page 5 · cliquer pour agrandir
Page 5

6. Safety information

Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.

a) People / Product

  • The device is not a toy. Keep it out of the reach of children and pets.
  • Do not leave packaging material lying around carelessly. These may become dangerous playing material for children.
  • Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity, moisture, flammable gases, vapours and solvents.
  • Do not place the product under any mechanical stress.
  • If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. Safe operation can no longer be guaranteed if the product:

-- is visibly damaged,

-- is no longer working properly,

-- has been stored for extended periods in poor ambient conditions or

-- has been subjected to any serious transport-related stresses.

  • Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
  • The mains outlet must be located near to the device and be easily accessible.
  • Never pull the mains plug from the socket by pulling at the cable. Always pull it from the mains socket using the intended grips.
  • Unplug the mains plug from the mains socket if you do not use the device for an extended period of time.
  • Disconnect the mains plug from the mains socket in thunderstorms for reasons of safety.
  • Make sure that the mains cable is not squeezed, bent, damaged by sharp edges or put under mechanical stress. Avoid excessive thermal stress on the mains cable from extreme heat or cold. Do not modify the mains cable. Otherwise the mains cable may be damaged. A damaged mains cable can cause a deadly electric shock.
  • Do not touch the mains cable if it is damaged. First, power down the respective mains socket (e.g. via the respective circuit breaker) and then carefully pull the mains plug from the mains socket. Never use the product if the mains cable is damaged.
  • A damaged mains cable may only be replaced by the manufacturer, a workshop commissioned by the manufacturer or a similarly qualified person, so as to prevent any danger.
  • Never plug in or unplug the mains plug when your hands are wet.
  • Disconnect the power plug from the power outlet to completely disconnect the device from the power network. Never disconnect the plug while the device is still switched on. Always use the keys on the remote control or the operating panel to switch the device on and off.
Page 6 of the Conrad 8000 BTU user manual — c) Miscellaneous
Page 6 · cliquer pour agrandir
Page 6
  • Disconnect the power plug from the power outlet for maintenance or to move the device.
  • Ensure that the mains voltage corresponds to the data listed on the data plate of the device. Connect the device only to an isolated ground receptacle.
  • Do not open the device. Do not insert any objects in to the openings.
  • Do not cover the device. Ensure sufficient ventilation. Keep a space of at least 50 cm in all directions around the device in order to ensure sufficient ventilation.
  • Always transport and place of the device in an upright position. Never used the device in a sloping position.
  • Do not sit on the device and do not place any objects on the device.
  • Do not operate the device with damp hands or while standing on wet ground.
  • Do not move the device while it is in operation.
  • Avoid contact of the device with chemicals.
  • Do not use spray cans near the device.
  • Do not use device near gases or flammable substances like alcohol, insecticides, gasoline, etc.
  • Warning - risk of electric shock! Never attempt to repair the device yourself. In case of malfunction, always have it repaired by qualified professionals.
  • This device is not intended to be used by persons (including children) with reduced physical, sensory or mental abilities or lack of experience and / or lack of knowledge unless they are supervised by a person responsible for their safety or have received instructions on how to use the device.
  • Children should be supervised to ensure that they do not play with the device.
  • Do not use the device if it fell to the ground or damages are visible.
  • Use the device only at a room temperature of 15 °C to 43 °C. The product will be damaged at a room temperature of more than 43 °C.

b) Batteries / Rechargeable batteries

  • Correct polarity must be observed while inserting the (rechargeable) batteries.
  • (Rechargeable) batteries should be removed from the device if it is not used for a long period of time to avoid damage through leaking. Leaking or damaged (rechargeable) batteries might cause acid burns when in contact with skin, therefore use suitable protective gloves to handle corrupted (rechargeable) batteries.
  • (Rechargeable) batteries must be kept out of reach of children. Do not leave (rechargeable) batteries lying around, as there is risk, that children or pets swallow them.
  • All (rechargeable) batteries should be replaced at the same time. Mixing old and new (rechargeable) batteries in the device can lead to (rechargeable) battery leakage and device damage.
  • (Rechargeable) batteries must not be dismantled, short-circuited or thrown into fire. Never recharge non-rechargeable batteries. There is a risk of explosion!

c) Miscellaneous

  • Consult an expert when in doubt about operation, safety or connection of the device.
  • Maintenance, modifications and repairs are to be performed exclusively by an expert or at a qualified shop.
  • If you have questions which remain unanswered by these operating instructions, contact our technical support service or other technical personnel.
Page 7 of the Conrad 8000 BTU user manual — a) Unpacking and inspection
Page 7 · cliquer pour agrandir
Page 7

7. Start-up operation

a) Unpacking and inspection

  • Open the bottom of the packaging and fold the bottom flaps toward the outside.
  • Put the product into a vertical position and remove the packaging by putting it up.
  • Let the product stand in a vertical position for at least two hours prior to switching the product on.
  • Inspected the content of the packaging for completeness and damages. If the content of the packaging is incomplete or if damages are found, do not operate the product. Return it to your seller immediately.
  • Comply with statutory provisions to dispose of the packaging material.
  • Store the packaging material if you would like to use it to package, ship, or transport the device in any way. Store it in such a way that it does not pose a potential risk. b) Assembly
Conrad 8000 BTU — a) Unpacking and inspection diagram (page 7)
Fig. 4 · a) Unpacking and inspection
Conrad 8000 BTU — a) Unpacking and inspection diagram (page 7)
Fig. 5 · a) Unpacking and inspection

Dia. A Dia. B Dia. C

  • First pull apart the exhaust hose (12) on one side. Attach the adapter (13) on the exhaust hose by twisting it onto the exhaust hose counter clockwise (Dia. A). The exhaust hose can be pulled out and bent into the desired shape.
  • Then attach the exhaust hose (12) with the adapter onto the exhaust opening (8) by twisting it counter clockwise (Dia. B).
  • Place the device near a window or a door. Carefully pull out the exhaust hose (12), if required. We recommend keeping the length of the hose as short as possible.
  • Open the window and measure the width of the window. The window guide (10) can be used only with sliding windows.
  • If the window is too wide for the window guide (10), you can obtain an additional window guide from your seller. Obtain information from your seller.
  • If the window is too narrow for the window guide (10), remove the inner part of the window guide.
  • Shorten the inner part of the window guide (10) to the desired length.
  • Insert this into the outer part of the window guide (10) and extend the window guide to the required length on the window.
Page 8 of the Conrad 8000 BTU user manual — c) Remote control
Page 8 · cliquer pour agrandir
Page 8
  • Drilled holes are located on the inside of the inner part. Use the enclosed crosshead screws to attach it to the window.
  • The window guide (10) will be fastened when the window is closed.
  • Now guide the adapter (13) into the opening of the window guide (10) (Dia. C).

You can also hang the exhaust hose (12) out of the window without using the window guide (10). Close the window as much as possible to prevent warm air from flowing back in.

Dia. D Dia. E

  • During the installation, the exhaust hose (12) should be placed as straight as possible (Dia. D). Do not extent it and do not connect it to other exhaust hoses, which may cause malfunction.
  • Do not bend the exhaust hose (12) (Dia. E).

c) Remote control

The remote control is operated with 2 x 1.5 V batteries type R03/LR03/AAA (not included).

  • Open the battery compartment (37) on the rear of the remote control. Insert the batteries according to the correct polarity (+/-).
  • Use only batteries of the same or similar type.
  • Remove all batteries if the device is not used for a longer period of time in order to prevent damages.
  • Then close the battery compartment. Ensure that the lid is correctly fastened.
  • Comply with the safety information regarding the handling of batteries/rechargeable batteries (see section “b) Batteries/Rechargeable batteries”).
  • Always point the IR sender (33) toward the IR receiver (32) on the operating panel (2) when using the remote control.
  • Ensure that there are no obstructions located between the remote control and the device, e.g. furniture, which might block transmission of the signal.
Page 9 of the Conrad 8000 BTU user manual — d) Fan (FAN)
Page 9 · cliquer pour agrandir
Page 9

8. Operation

Settings can be adjusted directly on the operating panel (2) of the device or the enclosed remote control.

Always place the device on a level, sturdy, and dry surface. Ensure a sturdy position, so that the device cannot tip over or fall down.

When you connect to the power plug (7) to the power outlet, a signal tone sounds, the indicator light POWER (24) and the display (19) will light up. The device is now in standby mode a) Switching on and off

  • Push the key (25, 36) to switch the device on or off.
  • The device is pre-set. When you switch the device on, the display (19) will show the temperature 22 °C, the indicator lights COOL (21) and LOW (17) will light up. Low fan speed is pre-set. When the compressor switches on, the indicator light COMP (15) will light up.
  • The compressor will switch on approximately 3 minutes after the device has been switched on.
  • Once you switch the device off, wait approximately 3 minutes before switching the device back on.
  • Use the air exhaust openings (4) to adjust the direction of the airflow.
  • Push the key (26, 34) to select between the operating modes “Cooling“ ( COOL ), “Dehumidify“ ( DEHUM ) and “Fan ” ( FAN ).

b) Cooling (COOL)

  • Select the operating mode “Cooling“. The indicator light COOL (21) will light up.
  • Push the keys (29, 41) or (28, 38) to adjust the temperature from 16 °C to 31 °C.
  • Push the key (31, 40) to set a high or low fan speed. With high fan speed, the indicator light HIGH (16) will light up. With low fan speed, the indicator light LOW (17) will light up.

The cooling function shuts off automatically if the room temperature is lower than the set temperature. The indicator light COMP (15) will go out. Once the room temperature increases, the cooling function switches on automatically.

c) Dehumidify (DEHUM)

  • Select the operating mode “Dehumidify“. The indicator light DEHUM (22) will light up.
  • The temperature, the sleep mode, and the fan speed ( HIGH/LOW ) cannot be set.

Keep doors and windows closed to achieve a better dehumidification performance.

d) Fan (FAN)

  • Select the operating mode “Cooling”. The indicator light FAN (23) will light up.
  • Push the key (31, 40) to select a high or low fan speed. With a high fan speed, the indicator light HIGH (16) will light up. With a low fan speed, the indicator light LOW (17) will light up.
  • Temperature and sleep mode cannot be set.
Page 10 of the Conrad 8000 BTU user manual — f) Sleep mode (SLEEP)
Page 10 · cliquer pour agrandir
Page 10

e) Timer (TIMER)

  • You can specify the time until the device switches on automatically from standby mode.
  • Push the key (30, 35) to select the desired time period (1 – 24 hours).
  • The indicator light TIMER (18) lights up and “01“ (=1 hour) will flash on the display.
  • Push the key (30, 35) repeatedly to select the desired time period. For example, if you would like to set three hours, push the key (30, 35) three times. “03“ will flash on the display.
  • Once the hour display stops flashing your settings are confirmed.
  • To switch the timer off, push the key (30, 35) repeatedly, until “00“ flashes on the display. The indicator light TIMER (18) will go out.
  • The device switches on automatically after the pre-set time has elapsed.
  • When the device is switched on, you can specify the time until the device switches off automatically.
  • Push the key (30, 35) to select the desired time period (1 – 24 hours).
  • The indicator light TIMER (18) lights up and “01“ (=1 hour) will flash on the display.
  • Push the key (30, 35) repeatedly to select the desired time period. For example, if you would like to set three hours, push the key (30, 35) three times. “03“ will flash on the display.
  • Once the hour display stops flashing your settings are confirmed.
  • To switch the timer off, push the key (30, 35) repeatedly, until “00“ flashes on the display. The indicator light TIMER (18) will go out.
  • The device switches off automatically after the pre-set time has elapsed.

f) Sleep mode (SLEEP)

  • Select the operating mode “Cooling“. The sleep mode is possible only in the operating mode “Cooling”.
  • Push the key (27, 39) to enter sleep mode. The fan speed is set on low.
  • Once you selected the sleep mode, the temperature will increase by 1 °C after one hour. After another hour, the temperature will again increase by 1 °C and will then remain constant.
  • The sleep mode is not possible ,

-- if the water tank is full (indicator light W.F = “Water Full“ will light up).

-- if the devices in standby mode.

Automatic on · Automatic off

Page 11 of the Conrad 8000 BTU user manual — b) Cleaning air filters
Page 11 · cliquer pour agrandir
Page 11

9. Troubleshooting

With this air conditioning unit you have purchased a state-of-the-art, reliable device. However, problems and malfunctions may occur; we would therefore like to inform you of how you can resolve possible malfunctions.

The device does not work.

  • The device is not connected to the power network. Connect the power plug to a suitable power outlet.
  • The safety fuse of the respective power outlet has blown.
  • If required, inspect the function of the power outlet using another device.

The remote control does not work.

  • Inspect whether batteries are located in the remote control and whether these are inserted according to the right polarity
  • The remote control is outside of the range of the device. Change the distance of the remote control to the device.
  • The batteries of the remote control are empty. Insert new batteries.

The device does not cool.

  • Ensure that windows and doors are closed. Warm air can enter the room.
  • The filters are soiled. Follow instructions in chapter “10. Maintenance and cleaning“.
  • The air exhaust openings are blocked. Ensure that the air exhaust openings are not blocked. Ensure an open space of at least 50 cm in all directions around the device for sufficient ventilation.

10. Maintenance and cleaning

Switch to device off and disconnect the power plug (7) from the power outlet prior to cleaning the device. Let the device cool off completely.

Insert the power plug into the power plug storage (6) protected from damage.

a) Casing

  • Wipe the casing with a slightly damp cloth.
  • Ensure that no liquid enters the inside of the casing.
  • Do not use abrasive or solvent-based cleaners as well as abrasive or pointy objects.
  • Never hold the device under flowing water white cleaning it, and do not submerge it in water or other liquids.

b) Cleaning air filters

  • Clean the air filters (3, 5) periodically.
  • First pull out the rear air filters (3) located on the rear.
  • Then pull out the site air filters (5).
  • Use a vacuum cleaner to clean the air filters (3, 5). If the filters are heavily soiled, wash them with warm water and a mild cleaning agent. Let them dry completely before reinserting them.
  • Then correctly reinsert the air filters. Be sure to first insert of the site air filters. Then insert the rear air filter (3).
Page 12 of the Conrad 8000 BTU user manual — d) Storage
Page 12 · cliquer pour agrandir
Page 12

c) Emptying water container

  • Empty the inner water container when it is completely full. The indicator light W.F (14) will flash and a signal will sound. The device cannot be operated.
  • Disconnect the power plug from the power outlet.
  • Place a suitable container under the drainage opening. Twist the fastener (a) off and pull the plug (b) from the drainage opening (Dia. F).
  • Let the water drain. When the container is almost full, close the drainage opening again using the plug; empty the container and repeat the process until water stops dripping.
  • Reinsert the plug (b) into the drainage opening and twist the fastener (a) back on.
  • When you switch the device on, the indicator light W.F (14) no longer lights up.
  • Do not leave the device unsupervised while emptying the water container. The container may overflow.
  • If the device will not be used for a long period of time, use the key (25, 36) to switch it on prior to storing it, and let it run in ventilation mode for several hours on a warm, dry day. This will help dry the interior of the device completely. We also recommend leaving the device standing for one day without fastener and plug, to air dry it.

Dia. F

d) Storage

Store the device in a cool, dry, clean location protected from sun exposure, and in the original packaging if possible.

a b

Page 13 of the Conrad 8000 BTU user manual — a) Air-conditioning unit (item no. 396453)
Page 13 · cliquer pour agrandir
Page 13

11. Disposal

a) Product

Electrical and electronic products do not belong in the household waste.

Dispose of the product according to the applicable statutory provisions at the end of its service life.

Remove any inserted (rechargeable) batteries and dispose of them separately from the product.

b) (Rechargeable) Batteries

As the end user, you are required by law (Battery Ordinance) to return all used (rechargeable) batteries; disposal of them in the household waste is prohibited!

Contaminated (rechargeable) batteries are labelled with this symbol to indicate that disposal in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).

Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever (rechargeable) batteries are sold.

You thus fulfil the legal requirements and make your contribution to protecting the environment.

12. Technical specifications

a) Air-conditioning unit (item no. 396453)

Model number JHS-A001-08KR/B1

Operating voltage 220 - 240 V/AC, 50 Hz

Power consumption 890 W

Cooling capacity 8000 BTU/h (2.4 kW)

Air throughput 380 m3/h

Coolant/volume R410A/370 g

Adjustable temperature range 16 – 31 °C

Noise level 64 dB(A)

Suitable for 8 – 12 m2

Exhaust hose length 1.5 m

Fuse FSD or 50F, F.3.15AL, 250 V/AC

Dimensions (W x H x D) 320 x 730 x 360 mm

Weight approx. 21 kg

Page 14 of the Conrad 8000 BTU user manual — c) Remote control
Page 14 · cliquer pour agrandir
Page 14

b) Air-conditioning unit (item no. 396454)

Model number JHS-A001-10KR/B1

Operating voltage 220 - 240 V/AC, 50 Hz

Power consumption 1100 W

Cooling capacity 10000 BTU/h (2.9 kW)

Air throughput 400 m3/h

Coolant/volume R410A/460 g

Adjustable temperature range 16 – 31 °C

Noise level 65 dB(A)

Suitable for 12 – 18 m2

Exhaust hose length 1.5 m

Fuse FSD or 50F, F.3.15AL, 250 V/AC

Dimensions (W x H x D) 320 x 730 x 360 mm

Weight approx. 24 kg

c) Remote control

Power supply 2 x 1.5 V/DC batteries (R03/LR03/AAA)

Dimensions (W x H x D) 165 x 38 x 15 mm

Weight 65 g

Poser une question sur : Conrad 8000 BTU

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Conrad 8000 BTU

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Conrad 8000 BTU manuel PDF

64 pages·1.8 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…