The mobile air-conditioning unit is designed to cool, ventilate, and dehumidify interior rooms. Always place the product on a level, sturdy, and dry surface.
The device is designed for domestic use. The product is not suitable for commercial use.
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bathrooms, must be avoided under all circumstances.
The manufacturer does not accept any responsibility for damages caused by improper use. Use only original accessories. Use the device only as described in this operating manual. Any other use may cause damages on the device or injuries.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you use the product for purposes other than those described above, the product may be damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and keep them. Make this product available to third parties only together with its operating instructions.
The triangle containing a lightning symbol warns against danger of electric shock or impairment of the electrical safety of the device.
An exclamation mark in a triangle indicates important notes in these operating instructions that must be strictly observed.
The „hand“ symbol indicates special information and advice on operation.



14 15 16 17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

3 Rear air filter
22 Indicator light DEHUM
4 Air exhaust openings (adjustable
23 Indicator light FAN
24 Indicator light POWER
5 Side air filter
25 Key (on/off switch)
6 Power plug storage
26 Key (select operating mode)
7 Power cord with power plug
27 Key (sleep mode)
28 Key (reduce value)
9 Wheels (not shown)
29 Key (increase value)
10 Extendable window guide
31 Key (fan speed)
11 6 x crosshead screws
12 Flexile exhaust hose
13 Adapter (for exhaust hose)
34 Key (select operating mode)
14 Indicator light W.F
36 Key (on/off switch)
15 Indicator light COMP
37 battery compartment (rear)
16 Indicator light HIGH
38 Key (reduce value)
17 Indicator light LOW
39 Key (sleep mode)
18 Indicator light TIMER
40 Key (fan speed)
41 Key (increase value)

Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
-- is visibly damaged,
-- is no longer working properly,
-- has been stored for extended periods in poor ambient conditions or
-- has been subjected to any serious transport-related stresses.




Dia. A Dia. B Dia. C

You can also hang the exhaust hose (12) out of the window without using the window guide (10). Close the window as much as possible to prevent warm air from flowing back in.
Dia. D Dia. E
The remote control is operated with 2 x 1.5 V batteries type R03/LR03/AAA (not included).

Settings can be adjusted directly on the operating panel (2) of the device or the enclosed remote control.
Always place the device on a level, sturdy, and dry surface. Ensure a sturdy position, so that the device cannot tip over or fall down.
When you connect to the power plug (7) to the power outlet, a signal tone sounds, the indicator light POWER (24) and the display (19) will light up. The device is now in standby mode a) Switching on and off
The cooling function shuts off automatically if the room temperature is lower than the set temperature. The indicator light COMP (15) will go out. Once the room temperature increases, the cooling function switches on automatically.
Keep doors and windows closed to achieve a better dehumidification performance.

-- if the water tank is full (indicator light W.F = “Water Full“ will light up).
-- if the devices in standby mode.
Automatic on · Automatic off

With this air conditioning unit you have purchased a state-of-the-art, reliable device. However, problems and malfunctions may occur; we would therefore like to inform you of how you can resolve possible malfunctions.
The device does not work.
The remote control does not work.
The device does not cool.
Switch to device off and disconnect the power plug (7) from the power outlet prior to cleaning the device. Let the device cool off completely.
Insert the power plug into the power plug storage (6) protected from damage.

Dia. F
Store the device in a cool, dry, clean location protected from sun exposure, and in the original packaging if possible.
a b

Electrical and electronic products do not belong in the household waste.
Dispose of the product according to the applicable statutory provisions at the end of its service life.
Remove any inserted (rechargeable) batteries and dispose of them separately from the product.
As the end user, you are required by law (Battery Ordinance) to return all used (rechargeable) batteries; disposal of them in the household waste is prohibited!
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that disposal in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil the legal requirements and make your contribution to protecting the environment.
Model number JHS-A001-08KR/B1
Operating voltage 220 - 240 V/AC, 50 Hz
Power consumption 890 W
Cooling capacity 8000 BTU/h (2.4 kW)
Air throughput 380 m3/h
Coolant/volume R410A/370 g
Adjustable temperature range 16 – 31 °C
Noise level 64 dB(A)
Suitable for 8 – 12 m2
Exhaust hose length 1.5 m
Fuse FSD or 50F, F.3.15AL, 250 V/AC
Dimensions (W x H x D) 320 x 730 x 360 mm
Weight approx. 21 kg

Model number JHS-A001-10KR/B1
Operating voltage 220 - 240 V/AC, 50 Hz
Power consumption 1100 W
Cooling capacity 10000 BTU/h (2.9 kW)
Air throughput 400 m3/h
Coolant/volume R410A/460 g
Adjustable temperature range 16 – 31 °C
Noise level 65 dB(A)
Suitable for 12 – 18 m2
Exhaust hose length 1.5 m
Fuse FSD or 50F, F.3.15AL, 250 V/AC
Dimensions (W x H x D) 320 x 730 x 360 mm
Weight approx. 24 kg
Power supply 2 x 1.5 V/DC batteries (R03/LR03/AAA)
Dimensions (W x H x D) 165 x 38 x 15 mm
Weight 65 g