FR
Astralpool logo
Notice d'utilisation officielle

Astralpool PRO-ELYO INVERTER

204 pages·9.9 MB·Pompe à chaleur·PDF·ENNLJA
Astralpool PRO-ELYO INVERTER
Table des matières 51 sections ENGLISH---------------------------------------------------------------------------P1-33 · FRENCH---------------------------------------------------------------------------P34-65 · PORTUGUESE----------------------------------------------------------------- P66-97 · ITALY -----------------------------------------------------------------------------P98-130 · … AfficherMasquer
ENGLISH---------------------------------------------------------------------------P1-33p.3FRENCH---------------------------------------------------------------------------P34-65p.3PORTUGUESE----------------------------------------------------------------- P66-97p.3ITALY -----------------------------------------------------------------------------P98-130p.3GERMANY--------------------------------------- -------------------------------P131-163p.3SPANISH------------------------------------------------------------------------ P164-197p.3User User User and and and service service service manual manual manualp.5SWIMMING POOL HEAT PUMPp.5INDEX INDEX INDEXp.6WARNING:p.61. 1. 1. Description Description Descriptionp.71.1 With your Heat Pumpp.71.2 Dimensionp.72. 2. 2. Specifications Specifications Specificationsp.9Kit By-Passp.104. 4. 4. Location Location Location and and and connection connection connectionp.114.1 Heat pump locationp.114.2 Check-valve installationp.11NOTEp.114.3 Typical arrangementp.124.4 Initial operationp.134.5 Condensationp.145. 5. 5. Electrical Electrical Electrical Wiring Wiring Wiringp.155.1 INVERTER SWIMMING POOL HEAT PUMP WIRING DIAGRAMp.15PRO-ELYO INVERTER 13 / PRO-ELYO INVERTER 21p.155.2 Electrical protectionp.165.3 Installation of the display deporteep.176. Display Controller Operationp.186.1. Guide for operationp.186.2 The keys and their operationsp.18ATTENTION:p.19Noted:p.20SMARTp.22SILENTp.227 POWERFULp.2211 SILENTp.2213 POWEFULp.227. 7. 7. Parameters Parameters Parametersp.247.1 How to know the current statusp.248. 8. 8. Troubleshooting Troubleshooting Troubleshootingp.268.1 Error code display on LED wire controllerp.26"ON"p.268.2 Other Malfunctions and Solutions (No display on LED wire controller)p.289. 1 Exploded Diagramp.299.2 Parts list 9.2.1 Pro-Elyo Inverter 13p.3210. 10. 10. Warranty Warranty Warrantyp.361. WARRANTY COVERAGEp.362. CONDITIONS TO WARRANTYp.363. LIMITATIONSp.36Manuel d’installation et d’utilisationp.38Pompe à chaleur pour piscinep.38
Page 2 of the Astralpool PRO-ELYO INVERTER user manual
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Astralpool PRO-ELYO INVERTER user manual
Page 3 of the Astralpool PRO-ELYO INVERTER user manual — ENGLISH---------------------------------------------------------------------------P1-33
Page 3 · cliquer pour agrandir
Page 3

ENGLISH P1-33

FRENCH---------------------------------------------------------------------------P34-65

PORTUGUESE----------------------------------------------------------------- P66-97

ITALY -----------------------------------------------------------------------------P98-130

GERMANY--------------------------------------- -------------------------------P131-163

SPANISH------------------------------------------------------------------------ P164-197

Page 4 of the Astralpool PRO-ELYO INVERTER user manual — ENGLISH---------------------------------------------------------------------------P1-33
Page 4 · cliquer pour agrandir
Page 4
Page 4 of the Astralpool PRO-ELYO INVERTER user manual — ENGLISH---------------------------------------------------------------------------P1-33
Page 5 of the Astralpool PRO-ELYO INVERTER user manual — User User User and and and service service service manual manual manual
Page 5 · cliquer pour agrandir
Page 5

User User User and and and service service service manual manual manual

SWIMMING POOL HEAT PUMP

Page 6 of the Astralpool PRO-ELYO INVERTER user manual — Table des matières
Page 6 · Table des matières
Table des matières

Table des matières

ENGLISH---------------------------------------------------------------------------P1-33p.3FRENCH---------------------------------------------------------------------------P34-65p.3PORTUGUESE----------------------------------------------------------------- P66-97p.3ITALY -----------------------------------------------------------------------------P98-130p.3GERMANY--------------------------------------- -------------------------------P131-163p.3SPANISH------------------------------------------------------------------------ P164-197p.3User User User and and and service service service manual manual manualp.5SWIMMING POOL HEAT PUMPp.5INDEX INDEX INDEXp.6WARNING:p.61. 1. 1. Description Description Descriptionp.71.1 With your Heat Pumpp.71.2 Dimensionp.72. 2. 2. Specifications Specifications Specificationsp.9Kit By-Passp.104. 4. 4. Location Location Location and and and connection connection connectionp.114.1 Heat pump locationp.114.2 Check-valve installationp.11NOTEp.114.3 Typical arrangementp.124.4 Initial operationp.134.5 Condensationp.145. 5. 5. Electrical Electrical Electrical Wiring Wiring Wiringp.155.1 INVERTER SWIMMING POOL HEAT PUMP WIRING DIAGRAMp.15PRO-ELYO INVERTER 13 / PRO-ELYO INVERTER 21p.155.2 Electrical protectionp.165.3 Installation of the display deporteep.176. Display Controller Operationp.186.1. Guide for operationp.186.2 The keys and their operationsp.18ATTENTION:p.19Noted:p.20SMARTp.22SILENTp.227 POWERFULp.2211 SILENTp.2213 POWEFULp.227. 7. 7. Parameters Parameters Parametersp.247.1 How to know the current statusp.248. 8. 8. Troubleshooting Troubleshooting Troubleshootingp.268.1 Error code display on LED wire controllerp.26"ON"p.268.2 Other Malfunctions and Solutions (No display on LED wire controller)p.289. 1 Exploded Diagramp.299.2 Parts list 9.2.1 Pro-Elyo Inverter 13p.3210. 10. 10. Warranty Warranty Warrantyp.361. WARRANTY COVERAGEp.362. CONDITIONS TO WARRANTYp.363. LIMITATIONSp.36Manuel d’installation et d’utilisationp.38Pompe à chaleur pour piscinep.38
Page 7 of the Astralpool PRO-ELYO INVERTER user manual — 1.2 Dimension
Page 7 · cliquer pour agrandir
Page 7

1. 1. 1. Description Description Description

1.1 With your Heat Pump

- Water connection assembly 50 mm (pcs: 2) - User and service manual - Condensed connection - 10 meters signal wire - Waterproof box - Winter cover - Anti-vibration base (pcs: 4)

1.2 Dimension

Astralpool PRO-ELYO INVERTER — 1.2 Dimension diagram (page 7)
Fig. 1 · 1.2 Dimension
Page 8 of the Astralpool PRO-ELYO INVERTER user manual — 1. 1. 1. Description Description Description
Page 8 · cliquer pour agrandir
Page 8
Astralpool PRO-ELYO INVERTER — 1. 1. 1. Description Description Description diagram (page 8)
Fig. 2 · 1. 1. 1. Description Description Description
Page 9 of the Astralpool PRO-ELYO INVERTER user manual — 2. 2. 2. Specifications Specifications Specifications
Page 9 · cliquer pour agrandir
Page 9

2. 2. 2. Specifications Specifications Specifications

Technical data PRO-ELYO Inverter pool heat pumps CE Standard, R410A, Heating and Cooling, inverter compressor, compressor defrosting, ABS Cabinet

ModelPRO-ELYO INVERTER 13PRO-ELYO INVERTER 21PRO-ELYO INVERTER 35 CODE661086610966110 * Performance at Air 27℃, Water 27℃, Humidity 80% Heating (Max./Std./Min.)kW13.5/9.3/6.321/15.8/10.533/24.8/16.5 Power consumption (Std.)kW1.232.083.26 C.O.P. (Std.)7.67.67.6 * Performance at Air 15℃, Water 26℃, Humidity 70% Heating (Max./Std./Min.)kW11.5/7.2/4.515/11/7.325/18.7/12.5 Power consumption (Std.)kW1.212.023.34 C.O.P. (Std.)5.65.65.6 * Performance at Air 5℃ Heating (Max./Std./Min.)kW9.5/6.1/3.810.8/8.0/4.518.6/14.9/8.5 Power consumption (Std.)kW1,361,783,21 C.O.P. (Std.)4,54,54,6 * Performance at Air -5℃ Heating (Max./Std./Min.)kW5.3/4.3/2.87.8/6.1/3.512.6/9.9/5.2 Power consumption (Std.)kW1,341,883,1 C.O.P. (Std.)3,23,23,2 Voltage220~240V/50Hz/1PH380V/50Hz/3PH Std. Current InputA5.496.4 Maximum CurrentA13.918.218.3 FuseA304040 Advised water fluxM3/h46.29 Refrigerantg160024003800 Advised pool volume (with pool cover)m338-6875-120120-160 Water Pressure DropKpa131618 Water in-out connectionmm50 Fan quantity12 Fan Speed650/450 Ventilation typeHorizontal Compressor typeDC Inverter Rotary Noise level at 1mdB(A)505052 Noise level at 10mdB(A)464647 Net dimensionmm1098*420*7861050*452*1264 Net weightKg7891145 Packing dimensionmm1160*455*9151115*500*1395 Gross weightKg83101160

* Above data are subjects to modification without notice.

Page 10 of the Astralpool PRO-ELYO INVERTER user manual — Kit By-Pass
Page 10 · cliquer pour agrandir
Page 10
3. 3. 3. Adjust Adjust Adjust the the the by-pass by-pass by-pass kit kit kit

Kit By-Pass

The kit By-Pass is the essential accessory for the installation of your heat pump; it is also a tool for the optimization of the heating of the water. The regulation of the valves allows to optimize the flow of water and with the manometer to make sure the optimize running of the compressor.

Page 11 of the Astralpool PRO-ELYO INVERTER user manual — 4.2 Check-valve installation
Page 11 · cliquer pour agrandir
Page 11

4. 4. 4. Location Location Location and and and connection connection connection

Astralpool PRO-ELYO INVERTER — 4. 4. 4. Location Location Location and and and connection connection connection diagram (page 11)
Fig. 3 · 4. 4. 4. Location Location Location and and and conn…
1. Any addition of chemicals must take place in the piping located downstream from the heat pump. 2. Always place the heat pump on a solid foundation and use the included rubber mounts to avoid vibration and noise. 3. Always hold the heat pump upright. If the unit has been held at an angle, wait at least 24 hours before starting the heat pump.

4.1 Heat pump location

The unit will work properly in any desired location as long as the following three items are present:

1. Fresh air 2. Electricity 3. Swimming pool filters

The unit may be installed in virtually any outdoor location as long as the specified minimum distances to other objects are maintained (see drawing below). Please consult your installer for installation with an indoor pool. Installation in a windy location does not present any problem at all, unlike the situation with a gas heater (including pilot flame problems).

Astralpool PRO-ELYO INVERTER — 4.1 Heat pump location diagram (page 11)
Fig. 4 · 4.1 Heat pump location

ATTENTION: Never install the unit in a closed room with a limited air volume in which the air expelled from the unit will be reused, or close to shrubbery that could block the air inlet. Such locations impair the continuous supply of fresh air, resulting in reduced efficiency and possibly preventing sufficient heat output. See the drawing below for minimum dimensions.

4.2 Check-valve installation

NOTE

Astralpool PRO-ELYO INVERTER — 4.2 Check-valve installation diagram (page 11)
Fig. 5 · 4.2 Check-valve installation
Page 12 of the Astralpool PRO-ELYO INVERTER user manual — 4.3 Typical arrangement
Page 12 · cliquer pour agrandir
Page 12

Note: If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential to protect the heat pump against excessively high chemical concentrations which may corrode the heat exchanger. For this reason, equipment of this sort must always be fitted in the piping on the downstream side of the heat pump, and it is rSMARTmmended to install a check-valve to prevent reverse flow in the absence of water circulation. Damage to the heat pump caused by failure to observe this instruction is not covered by the warranty.

Astralpool PRO-ELYO INVERTER — 4.3 Typical arrangement diagram (page 12)
Fig. 6 · 4.3 Typical arrangement

4.3 Typical arrangement

Astralpool PRO-ELYO INVERTER — 4.3 Typical arrangement diagram (page 12)
Fig. 7 · 4.3 Typical arrangement

This arrangement is only an illustrative example.

Page 13 of the Astralpool PRO-ELYO INVERTER user manual — 4.4 Initial operation
Page 13 · cliquer pour agrandir
Page 13

NOTE

The factory supplies only the heat pump. All other components, including a bypass if necessary, must be provided by the user or the installer.

Astralpool PRO-ELYO INVERTER — NOTE diagram (page 13)
Fig. 8

4.4 Initial operation

After all connections have been made and checked, carry out the following procedure:

1. Switch on the filter pump, check for leaks and verify that water is flowing from and to the swimming pool.
2. Connect power to the heat pump and press the On/Off button on the LED control panel. The unit will start up after the time delay expires (see below).
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump, the unit should also turn off automatically, if not, then adjust the flow switch.
5. Allow the heat pump and the filter pump to run 24 hours a day until the above 1 degree than desired water temperature is reached. The heat pump will stop running at this point. After this, it will restart automatically (as long as the filter pump is running) whenever the swimming pool water temperature drops 1 degree below the set temperature.

Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take several days to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce the required length of time.

Page 14 of the Astralpool PRO-ELYO INVERTER user manual — NOTE
Page 14 · cliquer pour agrandir
Page 14

NOTE

Water Flow Switch: It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate .It will turn on when the pool pump runs and shut it off when the pump shuts off.

Time delay - The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive contact wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions during this delay period do not affect the 3-minute duration of the delay.

4.5 Condensation

The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool water, which may cause condensation on the fins of the evaporator.

NOTE

The amount of condensation may be as much as several liters per hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.

4.6 Pressure gauge display (R410A) Examine the pressure gauge which indicates the refrigerant gas pressure of the unit, the below table shows the normal value of the gas pressure (R410A) when the machine is in power off or running conditions.

Unit Condition Power Off

Ambient (℃) -5~5 5~15 15~25 25~35

Water temp (℃) /

Pressure gauge (Mpa) 0.68~0.93 0.93~1.25 1.25~1.64 1.64~2.1

Ambient (℃) /

Water temp (℃) 10~15 15~20 20~25 25~30 30~35

Pressure gauge (Mpa) 1.3~1.8 1.5~1.9 1.6~2.3 1.9~2.8 2.1~3.5

Unit Condition Running

Page 15 of the Astralpool PRO-ELYO INVERTER user manual — 5.1 INVERTER SWIMMING POOL HEAT PUMP WIRING DIAGRAM
Page 15 · cliquer pour agrandir
Page 15

5. 5. 5. Electrical Electrical Electrical Wiring Wiring Wiring

5.1 INVERTER SWIMMING POOL HEAT PUMP WIRING DIAGRAM

PRO-ELYO INVERTER 13 / PRO-ELYO INVERTER 21

Astralpool PRO-ELYO INVERTER — 5.1 INVERTER SWIMMING POOL HEAT PUMP WIRING DIAGRAM diagram (page 15)
Fig. 9
Page 16 of the Astralpool PRO-ELYO INVERTER user manual — 5.2 Electrical protection
Page 16 · cliquer pour agrandir
Page 16
Astralpool PRO-ELYO INVERTER — 5.2 Electrical protection diagram (page 16)
Fig. 10 · 5.2 Electrical protection

Above electrical wiring diagram only for your reference, please subject machine posted the wiring diagram.

5.2 Electrical protection

NOTE

The swimming pool heat pump must be connected ground wire well, although the unit heat exchanger is electrically isolated from the rest of the unit .Grounding the unit is still required to protect you against short circuits inside the unit .Bonding is also required.

Page 17 of the Astralpool PRO-ELYO INVERTER user manual — 5.3 Installation of the display deportee
Page 17 · cliquer pour agrandir
Page 17
Astralpool PRO-ELYO INVERTER — 5.3 Installation of the display deportee diagram (page 17)
Fig. 11 · 5.3 Installation of the display deportee

5.3 Installation of the display deportee

Photo(1) Photo(2) Photo(3) Photo(4) Photo(5)

Astralpool PRO-ELYO INVERTER — 5.3 Installation of the display deportee diagram (page 17)
Fig. 12 · 5.3 Installation of the display deportee
Astralpool PRO-ELYO INVERTER — 5.3 Installation of the display deportee diagram (page 17)
Fig. 13 · 5.3 Installation of the display deportee
Astralpool PRO-ELYO INVERTER — 5.3 Installation of the display deportee diagram (page 17)
Fig. 14 · 5.3 Installation of the display deportee
Astralpool PRO-ELYO INVERTER — 5.3 Installation of the display deportee diagram (page 17)
Fig. 15 · 5.3 Installation of the display deportee
Astralpool PRO-ELYO INVERTER — 5.3 Installation of the display deportee diagram (page 17)
Fig. 16 · 5.3 Installation of the display deportee

- The side with plug connects with the control panel (photo1) - The other side of the signal wire. (photo2) - Open the wiring panel and put the side without plug through the electrical box. (photo3,4) - Insert the wiring into the designated position (upper right corner) on the PC board. (photo5)

Page 18 of the Astralpool PRO-ELYO INVERTER user manual — 6.2 The keys and their operations
Page 18 · cliquer pour agrandir
Page 18
6. 6. 6. Start-up Start-up Start-up of of of the the the Heat Heat Heat Pump Pump Pump

6. Display Controller Operation

6.1. Guide for operation

Astralpool PRO-ELYO INVERTER — 6.1. Guide for operation diagram (page 18)
Fig. 17 · 6.1. Guide for operation

NOTE

When the swimming pool heat pump is running, the display inform the water temperature. When the Heat

6.2 The keys and their operations

6.2.1 button

Press to start the heat pump unit, the LED display shows the

desired water temperature for 5 seconds, then shows the inlet water

temperature and the operation mode.

Press to stop the heat pump unit and show “OFF”

Press again to turn on/off the machine.

6.2.2 button

Page 19 of the Astralpool PRO-ELYO INVERTER user manual — ATTENTION:
Page 19 · cliquer pour agrandir
Page 19

Press for 5s to change the “ Heat MODE” or “ Cool MODE” .

( Noticethis operation is unavailable for the heating only machine)

6.2.3 and button

Water temperature setting :

Press and to set the water temperature directly.

Parameter checking :

Press first, then press to check the “ User parameter from d1 to d9.

TIME checking :

Press first, then press to check “current time”, press again to check the “Automatic

start time “ press once again to check “ Automatic stop time “ .

Press first ,then press the to enter into “Current time “ displaying . Then press once again

to enter into “HOUR” setting. The “Hour “ flashes, and press the or to set the hour ,then press

to save the “Hour”. Then the “ Minute” flashes, and press the or to set the “Minute” and finally

press the to save the current time setting , or press for quick-exit and saving.

ATTENTION:

If the current time is in the range of time OFF, the machine will be turn OFF automatically after setting the

time of automatic start and the time of automatic stop. Whereas the machine will operate normally.

Timer On setting:

Press first ,then press the twice to enter into ‘Timer on’ interface. Then press once again

to enter into “HOUR” setting. The “Hour “ flashes, and press the or to set the hour ,then press

TIME setting

Page 20 of the Astralpool PRO-ELYO INVERTER user manual — Noted:
Page 20 · cliquer pour agrandir
Page 20

to save the “Hour”. Then the “ Minute” flashes, and press the or to set the “Minute” and finally

press the to save the current time setting , or press for quick-exit and saving.

Once you set the timer on successfully , the light

will display.

Timer off setting:

Press first ,then press the three times to enter into ‘Timer off’’ interface. Then press once

again to enter into “HOUR” setting. The “Hour “ flashes, and press the or to set the hour ,then

press to save the “Hour”. Then the “ Minute” flashes, and press the or to set the “Minute” and

finally press the to save the current time setting , or press for quick-exit and saving.

Once you set the timer off successfully , the light

will display.

When you set Timer ON/OFF data 00:00, it means cancel the Timer ON/OFF function.

Astralpool PRO-ELYO INVERTER — Noted: diagram (page 20)
Fig. 18 · Noted:

NOTE

In order to heat the water in the pool (or hot tub), the filter pump must be running to cause the water to circulate through the heat pump. The heat pump will not start up if the water is not circulating. If the water is not circulating and the Heat Pump is ON the LED controller inform with the error code ON

Noted:

LED wire controller can operate the water pump after connected additional cable to the pump device in the position of “PUMP” terminal accurately. When HP stop running in 30 seconds, water pump will shut off automatically

6.2.4 System reset function

Cancel Timer ON/OFF

Page 21 of the Astralpool PRO-ELYO INVERTER user manual — Noted:
Page 21 · cliquer pour agrandir
Page 21

Press and in 10s, the system will reset and display “0000” on the controller.

Symbol of heating, the light will be on when it is in operation.

When defrosting, the light will flash.

Symbol of cooling, the light will be on when it is in operation.

Symbol of automatic stop, the light will be on when it is in operation.

Symbol of automatic start, the light will be on when it is in operation.

Press this button, the light will be on, the heat pump will operate in Powerful only..

While you choose the Smart, the heat pump will just operate in Smart and Powerful.

While you choose the Silent , the heat pump will just operate in Silent and Smart.

The operating logistic of shift between Silent, Smart and Powerful: the default setting in factory is in Smart operating mode.

6.3 The operating logic

Page 22 of the Astralpool PRO-ELYO INVERTER user manual — 13 POWEFUL
Page 22 · cliquer pour agrandir
Page 22

6.3.1 The heating operation logic

Working status Working mode Water in temperature Heat pump working level

2 setT-1< and < setT+1 SMART

SMART

3 ≧setT+1 Standby

Start-up of heat pump

5 setT-1< and < setT+1 SILENT

SILENT

6 ≧setT+1 Standby

7 POWERFUL

8 ≧setT+1 Standby

>setT -1 Standby

10 setT-3< and ≦setT-1 SMART

SMART

11 ≦setT-3 POWERFUL

Re-start to heat water

>setT -1 Standby

13 setT-3< and ≦setT-1 SILENT

SILENT

14 ≦setT-3 SMART

15 POWERFUL ≦setT-1 POWERFUL

6.3.2 The Cooling operation logic

Working status Working mode Water in temperature Heat pump working level

2 setT-1< and

SMART

3 ≧setT+1 POWERFUL

Start-up of heat pump

5 setT-1< and

SILENT

6 ≧setT+1 SMART

7 POWERFUL

8 ≦setT-1 Standby

≧setT+1 and

SMART

10 ≧setT+3 POWERFUL

11 SILENT

Re-start to cool water

≧setT+1 and

12 ≧setT+3 POWERFUL

13 POWEFUL

14 ≦setT Standby

Show 9 more labels / short text on this page
≦setT-1 POWERFUL · ≦setT-1 SMART · <setT+1 POWERFUL · in standby status · ≦setT-1 Standby · ≦setT-1 Standby · >setT-1 POWERFUL · in standby status · ≧setT+1 POWERFUL
Page 23 of the Astralpool PRO-ELYO INVERTER user manual — SMART
Page 23 · cliquer pour agrandir
Page 23
Astralpool PRO-ELYO INVERTER — SMART diagram (page 23)
Fig. 19
Astralpool PRO-ELYO INVERTER — SMART diagram (page 23)
Fig. 20
Astralpool PRO-ELYO INVERTER — SMART diagram (page 23)
Fig. 21

6.4 About the ambient temperature for the working frequency When you choose the “ POWERFUL “ working mode , if the ambient temperature ≧30℃and

and display the error code PP09 for compressor protection.

6.5 About the limitation of water in temperature Water in temperature ≦7℃, the heat pump will stop operation.

code EE3 or ON advertise on the controller.

It is important to program the heat pump link the time program of the water filtration system.

For restart the heat pump, turn off and turn on the electrical power supply to restart the unit.

Page 24 of the Astralpool PRO-ELYO INVERTER user manual — 7.1 How to know the current status
Page 24 · cliquer pour agrandir
Page 24

7. 7. 7. Parameters Parameters Parameters

7.1 How to know the current status

Press first, then press to check the user parameter from d1 to d9 as below:

Astralpool PRO-ELYO INVERTER — 7.1 How to know the current status diagram (page 24)
Fig. 22 · 7.1 How to know the current status
Astralpool PRO-ELYO INVERTER — 7.1 How to know the current status diagram (page 24)
Fig. 23 · 7.1 How to know the current status
Astralpool PRO-ELYO INVERTER — 7.1 How to know the current status diagram (page 24)
Fig. 24 · 7.1 How to know the current status
Astralpool PRO-ELYO INVERTER — 7.1 How to know the current status diagram (page 24)
Fig. 25 · 7.1 How to know the current status
Astralpool PRO-ELYO INVERTER — 7.1 How to know the current status diagram (page 24)
Fig. 26 · 7.1 How to know the current status

Parameter Name Range Remarks

d1 Inlet water temperature -9-99 ℃ Real testing value

d2 Outlet water temperature -9-99 ℃ Real testing value

d3 Ambient temperature -F(-30℃)-70℃ Real testing value

d4 Gas return temperature -F(-30℃)-70℃ Real testing value

d5 Coil temperature -F(-30℃)-70℃ Real testing value

d6 Gas exhaust temperature 0-C5℃(125℃) Real testing value

d7 Steps of electronic expansion valve 0-99 N*5

d8 Compressor operating frequency

0-99Hz Real testing value value

Powerful65,70,75Hz
Smart50,55,60Hz
Silent30,35,40,45Hz

d9 Compressor current 0-30A Real testing value

Page 25 of the Astralpool PRO-ELYO INVERTER user manual — NOTE
Page 25 · cliquer pour agrandir
Page 25

NOTE

Recover to Factory default setting

Long press and at the same time for 10 second to recover to factory default setting ,it will display ‘0000’ for 5 seconds is still required to protect you against short circuits inside the unit .Bonding is also required.

(1) When HP stop running in 30 seconds, water pump will shut off automatically

(2) LED wire controller can operate the water pump after connected additional cable to the pump device in the position of “PUMP” terminal accurately.

(3) It is necessary to put an extra 3-phase transfer device for 3 phase water pump.

Page 26 of the Astralpool PRO-ELYO INVERTER user manual — "ON"
Page 26 · cliquer pour agrandir
Page 26

8. 8. 8. Troubleshooting Troubleshooting Troubleshooting

8.1 Error code display on LED wire controller

Malfunction Error code Reason Solution

Inlet water temperature sensor

PP01 The sensor in open or short circuit Check or change the sensor

Outlet water temperature sensor

PP02 The sensor in open or short circuit Check or change the sensor

Heating condenser sensor failure PP03 The sensor in open or short circuit Check or change the sensor

Gas return sensor failure PP04 The sensor in open or short circuit Check or change the sensor

PP05 The sensor in open or short circuit Check or change the sensor

Condenser gas exit sensor failure PP06 The sensor in open or short circuit Check or change the sensor

Antifreeze protection in Winter PP07 Ambient temperature or water inlet

temperature is too low

PP08 Ambient temperature or water inlet

temperature is too low

Ambient temperature is too in

PP09 Ambient temperature is too

Stop the heat pump and wait

the ambient temperature at

less than Air 50℃( less 5 ℃in

The error code will disappear

Stop the heat pump and wait

temperature is too high

High pressure failure EE01 1.Refrigerant is too much

1.Discharge redundant refrigerant

2. Air flow is not enough

from HP gas system

2.Clean the air exchanger

Low pressure failure EE02 1.Refrigerant is not enough

1.Check if there is any gas

2.Water flow is not enough

leakage ,re-fill the refrigerant

3. Filter jammed or capillary

2.Clean the air exchanger

3.Replace the filter or capillary

Water flow failure EE03 or

Low water flow, wrong flow

Check if the water flow is enough

"ON"

direction, or flow switch failure.

and flow in right direction, or else

the flow switch could be failed.

Show 17 more labels / short text on this page
failure · failure · Ambient temperature sensor · failure · Low ambient temperature · protection · heating mode · high · allowance) · automatically · Cooling condenser · PP10 Cooling condenser · temperature too high · the cooling condenser · protection · temperature drop down · jammed
Page 27 of the Astralpool PRO-ELYO INVERTER user manual — 8. 8. 8. Troubleshooting Troubleshooting Troubleshooting
Page 27 · cliquer pour agrandir
Page 27

Malfunction Error code Reason Solution

EE05 Defrosting is not good

The throttling device is

Change the throttling device

Check the water pump

Controller failure EE06 Wire connection is not good

Check or change the signal

Restart the power supply or

Converter failure EE07 Converter board failure Restart the power supply or

change the converter board

EE08 Wire connection is not good

Check or change the wire

Restart the power supply or

EE09 Wire connection between

Restart the power supply or

outdoor board is wrong

change the outdoor board

EE10 Communication wire is

Restart the power supply or

between outdoor board and

change the broken board

Outdoor board or module

Module board failure EE11 The data is wrong or the

Restart the power supply or

module board is broken

change the broken board

Direct main current’s voltage

EE12 The pressure is too high or

Check the power supply

too high or too low

Over current protection EE13 Electric supply pressure is

Check the power supply

too low, the heat pump is

temperature whether it is too

Symbol of Defrosting, the

heating light is on

Show 35 more labels / short text on this page
Gas exhaust temperature · Defrosting by hand · sensor failure · Lack of gas · Plus the gas · jammed · Low water flow · Controller failure · wire · change the controller · Communication failure · between controller and · Controller failure · connection · converter board · change the controller · Communication failure · Rewiring · between converter and · communication wire and · outdoor board · Outdoor board failure · module board failure · broken · module board · board failure · too low · Change the contactor · protection · The inner communication · contactor is broken · Check the water · overload · high · Defrosting
Page 28 of the Astralpool PRO-ELYO INVERTER user manual — 8.2 Other Malfunctions and Solutions (No display on LED wire controller)
Page 28 · cliquer pour agrandir
Page 28

8.2 Other Malfunctions and Solutions (No display on LED wire controller)

Malfunctions Observing Reasons Solution

Check cable and circuit breaker

no display.

if it is connected

LED wire controller.

Heat pump under standby

Startup heat pump to run.

Displays the actual time.

1. Water temperature is
1. Verify water temperature

reaching to setting value, HP

setting.

2. Startup heat pump after a

status.

few minutes.

water temperature.

2. Heat pump just starts to run.
3. LED wire controller should
3. Under defrosting.

display "Defrosting".

1. Adjust the mode to proper
2. Replace the defect LED wire

controller, and then check the

LED wire controller displays

1. Choose the wrong mode.

status after changing the

actual water temperature and

2. Figures show defects.

running mode, verifying the

no error code displays.

3. Controller defect.

water inlet and outlet

temperature.

3. Replace or repair the heat
1. Check the cable connections

between the motor and fan, if

necessary, it should be

replaced.

LED displays actual water

1. Fan NO running.
2. Check the location of heat

temperature, no error code

2. Air ventilation is not enough.

pump unit, and eliminate all

displays.

3. Refrigerant is not enough.

obstacles to make good air

ventilation.

3 Replace or repair the heat

pump unit.

1. No action.

Water stains on heat pump

1. Concreting.
2. Check the titanium heat

unit.

2. Water leakage.

exchanger carefully if it is any

defect.

1. Check the location of heat

pump unit, and eliminate all

Too much ice on

obstacles to make good air

Too much ice on evaporator.

ventilation.

2. Replace or repair the heat

pump unit.

Show 17 more labels / short text on this page
LED wire controller · No power supply · status · Heat pump is · not running · LED wire controller · under constant temperature · displays the actual · running · Water temperature is · cooling when HP · runs under heating · mode · pump unit · Short running · water stains · evaporator
Page 29 of the Astralpool PRO-ELYO INVERTER user manual — 9. 1 Exploded Diagram
Page 29 · cliquer pour agrandir
Page 29
9. Exploded Exploded Exploded Diagram Diagram Diagram and and and Mantaince Mantaince Mantaince

9. 1 Exploded Diagram

Astralpool PRO-ELYO INVERTER — 9. 1 Exploded Diagram diagram (page 29)
Fig. 27 · 9. 1 Exploded Diagram
Page 30 of the Astralpool PRO-ELYO INVERTER user manual — 9. 1 Exploded Diagram
Page 30 · cliquer pour agrandir
Page 30
Astralpool PRO-ELYO INVERTER — 9. 1 Exploded Diagram diagram (page 30)
Fig. 28 · 9. 1 Exploded Diagram
Page 31 of the Astralpool PRO-ELYO INVERTER user manual — 9. 1 Exploded Diagram
Page 31 · cliquer pour agrandir
Page 31
Astralpool PRO-ELYO INVERTER — 9. 1 Exploded Diagram diagram (page 31)
Fig. 29 · 9. 1 Exploded Diagram
Page 32 of the Astralpool PRO-ELYO INVERTER user manual — 9.2 Parts list 9.2.1 Pro-Elyo Inverter 13
Page 32 · cliquer pour agrandir
Page 32

9.2 Parts list 9.2.1 Pro-Elyo Inverter 13

NO Part Name ERP NO Part Name ERP 1 Top cover 133070019 23 Terminal block 105000004 2 Back panel 133070031 24 Clip 136010004 3 Evaporator 103000104 25 Titanium heat exchanger 102040410

4 Pillar 108160016 25 Heat exchanger bottom plug 102040410 5 PFC inductor 117220001 25 Water connection cover 102040410 6 Left side panel 133070022 25 Water connection cover 102040410 7 Isolated panel 108160028 26 Pressure gauge 106000001 8 Base tray 108160044 27 Right panel 133070012 9 Top frame bracket 108160027 28 Waterproof controller box 133020003

10 Fan motor bracket(H series) 108160029 29 Controller 117020097 11 Fan motor 112000009 30 Wiring box 108010018 12 Fan blade 132000013 31 High pressure switch 116000008 13 Front panel 133070006 32 Low pressure switch 116000016 14 Front grill 108160012 33 Low pressure switch 116000020 15 Liquid storage pot 105000004 34 Suction valve 120000026 16 Inverter integration mainboard 117100006 35 Piping 114000044 17 slot 136020003 36 4‐way valve 121000009 18 Fan motor capacitor 111000005 37 EEV 119000021 19 Controller box 108160030 38 Water inlet rubber ring (blue) 133020011 20 Compressor 101000115 39 Water flow switch 116000001 21 Electric box cover 108160031 40 Filter 120000066 22 Terminal block box 108160024 41 Water outlet rubber ring (red) 133020012

42 Ambient temperature sensor

clip 113715001

Page 33 of the Astralpool PRO-ELYO INVERTER user manual — 9.2 Parts list 9.2.1 Pro-Elyo Inverter 13
Page 33 · cliquer pour agrandir
Page 33

NO Part Name ERP NO Part Name ERP

1 Top cover 133100001 33 Titanium exchanger 102040397

2 Back panel 133070032 33 Heat exchanger bottom plug 102040397

3 Evaporator 133000036 33 Water connection cover 102040397

4 Isolated panel 108120026 33 Water connection cover 102040397

5 Fan motor bracket 108120010 34 Water flow switch 116000001

6 Top frame bracket 108120005 35 Terminal blocks panel 108120020

7 Pillar 108120007 36 Five‐position blocks 115000004

8 Left side panel 133100012 39 Clip 136010004

9 PFC Inductor 117220002 40 Wiring box 108010018

10 Base tray 108120025 41 High pressure gauge 106000001

11 Fan motor 112000009 42 Right side panel 133070033

12 Fan motor 112000009 43 Terminal blocks plastic cover 133100011

13 Fan blade 132000013 44 Waterproof controller box 133020003

14 Fan blade 132000013 45 Controller 117020097

15 Front panel 133100006 46 Low pressure switch 116000019

16 Front grill 108160012 47 Low pressure switch 116000016

17 Front grill 108160012 48 Suction valve 120000023

18 Compressor 101000130 49 Water inlet rubber ring (blue) 133020011

19 Main board fixed panel 108050029 50 High pressure switch 116000008

20 Frequency conversion integrated

motherboard 117100008 51 Piping 113010013

21 Main board fixed panel 108050029 52 Temperature sensor casing 113190001

22 Controller box 108120027 53 4 way valve 121000009

23 Fan motor capacitor 111000005 54 Water outlet rubber ring (red) 133020012

30 Controller box cover 108120028 55 EEV 119000021

31 temperature sensor 117110014 56 Filter 120000066

32 Heat exchanger temperature sensor

clamp 108010025 57 Ambient temperater sensor

58 Liquid storage pot 105000008

clip 133020010

Page 34 of the Astralpool PRO-ELYO INVERTER user manual — 9.2 Parts list 9.2.1 Pro-Elyo Inverter 13
Page 34 · cliquer pour agrandir
Page 34

NO Part Name ERP NO Part Name ERP 1 Top cover 133100001 33 Heat exchanger bottom plug 102040411 2 Back panel 133070032 33 Water connection cover 102040411 3 Evaporator 103000109 33 Water connection cover 102040411 4 Isolated panel 108120009 34 Water flow switch 116000001 5 Fan motor bracket 108120010 35 Terminal blocks panel 108120020 6 Top frame bracket 108120006 36 Three‐position blocks 115000025 7 Pillar 108120007 37 Block panel bracket 108010023 8 Left side panel 133100012 38 Water pump blocks 115000027 10 Fan motor 112000009 39 Clip 136010004 11 Thin‐film capacitor 111000028 40 Wiring box 108010018 12 Capacitor clip 108010007 41 High pressure gauge 106000001 13 Electric reactor 117230001 42 Right side panel 133070033 14 Fan blade 132000013 43 Terminal blocks plastic cover 133100011 15 Front panel 133100006 44 Waterproof controller box 133020003 16 Front grill 108160012 45 Controller 117020097 17 Front grill 108160012 46 Low pressure switch 116000020 18 Controller box 108070028 47 Low pressure switch 116000016 19 IPM module 117080004 48 Suction valve 120000023 20 Fan motor capacitor 111000005 49 Water inlet rubber ring (blue) 133020011 21 Thermistor 117150001 50 High pressure switch 116000008 22 AC contactor 104000003 51 Piping 113010013 23 Termical blocks 115000009 52 Temperatur sensor casing 113190001 24 Compressor 101000114 53 4 way valve 121000009 25 Scaleboard 108120015 54 Water outlet rubber ring (red) 133020012 26 Outdoor power board 117190004 55 EEV 119000022 27 slot 136020003 56 Filter 120000066 28 linear transformer 117030005 57 Ambient temperater sensor clip 133020010 29 Indoor transfer board 117180021 58 Liquid storage pot 105000008 30 Outdoor control mould 117200003 59 Scaleboard 108120016 31 Temperature sensor 117110014 60 Controller box cover 108120018

32 Heat exchanger temperature

sensor clamp 108010025 61 Controller box 108120013

33 Titanium exchanger 102040411 62 Base 108120003

Page 35 of the Astralpool PRO-ELYO INVERTER user manual — 9.2 Parts list 9.2.1 Pro-Elyo Inverter 13
Page 35 · cliquer pour agrandir
Page 35

9.3 Maintenance (1) You should check the water supply system regularly to avoid the air entering the system and occurrence of low water flow, because it would reduce the performance and reliability of HP unit.

(2) Clean your pools and filtration system regularly to avoid the damage of the unit as a result of the dirty of clogged filter.

(3) You should discharge the water from bottom of water pump if HP unit will stop running for a long time (especially during the winter season).

(4) In another way, you should check the unit is water fully before the unit start to run again.

(5) After the unit is conditioned for the winter season, he is preconize to cover the heat pump with special winter heat pump.

(6) When the unit is running, there is all the time a little water discharge under the unit.

Page 36 of the Astralpool PRO-ELYO INVERTER user manual — 3. LIMITATIONS
Page 36 · cliquer pour agrandir
Page 36

10. 10. 10. Warranty Warranty Warranty

1. WARRANTY COVERAGE

1.1 In accordance with these provisions, the salesman guarantees that the product corresponding to this warranty (“the

product”)does not present any non-conformance at the moment of its delivery.

1.2 The warranty period of the product is of two (2) years and it will take effect as of the time of delivery to the buyer.

1.3 If a Product non-conformance occurs and the buyer notifies it to the salesman during the Warranty Period, the salesman should

repairor replace the Product at his own cost in the appropriate place, unless it is impossible or disproportionate.

1.4 When the Product cannot be repaired nor be replaced, the buyer shall be able to ask for a proportional price reduction or, if the

non-conformance is sufficiently important, the discharge of the sales contract.

1.5 The replaced or repaired parts by virtue of this warranty will not extend the warranty term of the original Product, although they

willhave its own warranty.

1.6 For the effectiveness of this warranty, the buyer will have to credit the acquisition date and delivery date of the Product.

1.7 When the delivery of the Product to the buyer had been more than six months before and the buyer alleges non-conformance

with the Product, the buyer will have to prove the origin and existence of the alleged fault.

1.8 The present Warranty Certificate does not limit or prejudges the rights the consumers are entitled by virtue of local prevailing and

applicable regulations.

2. CONDITIONS TO WARRANTY

2.1 This warranty covers the products referred to in this manual.

2.2 This Warranty Certificate will be solely applicable in the countries of the European Union.

2.3 For the effectiveness of this warranty, the buyer will have to strictly follow the manufacturer instructions included in the

documentation enclosed with the Product, whenever this warranty is applicable according to the Product range and model.

2.4 When a calendar for the substitution, maintenance or cleaning of certain parts or components of the Product is specified, the

Warrantywill only be valid when the calendar has been observed.

3. LIMITATIONS

3.1 This warranty will be solely applicable to those sales to consumers, being understood “consumers” as those people who acquire

the Product with a purpose that does not fall within the scope of their professional activity.

3.2 No warranty is granted referred to the wear and tear caused by the use of the Product. In relation to the parts, components and/or

consumable materials such as batteries, light bulbs etc, it will refer to the provisions of the documentation enclosed with the Product, when

applicable.

3.3 The warranty does not cover those cases where the Product: (I) has been incorrectly treated; (II) has been repaired, maintained

ormanipulated by a nonauthorized person, or (III) has been repaired or maintained with nonoriginal pieces.

When the non-conformance of the Product is a consequence of an incorrect installation or start-up, this warranty will only cover those

installations or start-ups included in the contract of sale of the Product and carried out by the salesman or under his/her responsibility.

Astralpool PRO-ELYO INVERTER — 3. LIMITATIONS diagram (page 36)
Fig. 30
Page 37 of the Astralpool PRO-ELYO INVERTER user manual — 10. 10. 10. Warranty Warranty Warranty
Page 37 · cliquer pour agrandir
Page 37

Declares under their own responsibility that all the heat pumps: Pro Elyo Inverter

Manufactured since 31/03/2012, independent of the serial number, are in compliance with:

Machine safety directive 2006/42/EC.

Electromagnetic compatibility directive 2004/108/EC and its modifications.

Low-voltage equipment directive 2006/95/EC.

Directive 2000/14/CE concerning noise produced by equipment for outdoors use, as amended by Directive 2005/88/EC.

Restrictions in the use of certain risky substances in the electrical and electronic instruments 2002/95/EC (RoHS).

Relative to the electrical and electronic waste products 2002/96/EC (RAEE). Relative to the electrical and electronic

instruments and the management of their waste products Spanish R.D. 208/2005.

The registration, the evaluation, the authorization and the restriction of the chemical substances EC Nº 1907/2006 (REACH).

Page 38 of the Astralpool PRO-ELYO INVERTER user manual — Manuel d’installation et d’utilisation
Page 38 · cliquer pour agrandir
Page 38

Manuel d’installation et d’utilisation

Pompe à chaleur pour piscine

Codes d'affichage

Codes d'erreur

La signification des codes d'erreur affichés à l'écran et la façon de les effacer.

CodeSignificationSolution
PP01The sensor in open or short circuitCheck or change the sensor p.26
PP02The sensor in open or short circuitCheck or change the sensor p.26
PP03The sensor in open or short circuitCheck or change the sensor p.26
PP04The sensor in open or short circuitCheck or change the sensor p.26
PP05The sensor in open or short circuitCheck or change the sensor p.26
PP06The sensor in open or short circuitCheck or change the sensor p.26
PP07Ambient temperature or water inlet temperature is too low p.26
PP08Ambient temperature or water inlet temperature is too low p.26
PP09Ambient temperature is too highStop the heat pump and wait the ambient temperature at less than Air 50℃( less 5 ℃in allowance) The error code will disappear automatically p.26
PP10Cooling condenser temperature is too highStop the heat pump and wait the cooling condenser temperature drop down p.26
EE011.Refrigerant is too much 2. Air flow is not enough1.Discharge redundant refrigerant from HP gas system 2.Clean the air exchanger p.26
EE021.Refrigerant is not enough 2.Water flow is not enough 3. Filter jammed or capillary jammed1.Check if there is any gas leakage ,re-fill the refrigerant 2.Clean the air exchanger 3.Replace the filter or capillary p.26
EE03 or "ON"Low water flow, wrong flow direction, or flow switch failure.Check if the water flow is enough and flow in right direction, or else the flow switch could be failed. p.26
EE05Defrosting is not good Lack of gas The throttling device is jammed Low water flowDefrosting by hand Plus the gas Change the throttling device Check the water pump p.27
EE06Wire connection is not good Controller failureCheck or change the signal wire Restart the power supply or change the controller p.27
EE07Converter board failureRestart the power supply or change the converter board p.27
EE08Wire connection is not good Controller failureCheck or change the wire connection Restart the power supply or change the controller p.27
EE09Wire connection between communication wire and outdoor board is wrong Outdoor board failureRewiring Restart the power supply or change the outdoor board p.27
EE10Communication wire is broken Outdoor board or module board failureRestart the power supply or change the broken board p.27
EE11The data is wrong or the module board is brokenRestart the power supply or change the broken board p.27
EE12The pressure is too high or too low The inner communication contactor is brokenCheck the power supply Change the contactor p.27
EE13Electric supply pressure is too low, the heat pump is overloadCheck the power supply Check the water temperature whether it is too high p.27
Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Heat pump is not runningNo power supplyCheck cable and circuit breaker if it is connected p.28
Heat pump is not runningHeat pump under standby statusStartup heat pump to run. p.28
Heat pump is not running1. Water temperature is reaching to setting value, HP under constant temperature status. 2. Heat pump just starts to run. 3. Under defrosting.1. Verify water temperature setting. 2. Startup heat pump after a few minutes. 3. LED wire controller should display "Defrosting". p.28
Water temperature is cooling when HP runs under heating mode1. Choose the wrong mode. 2. Figures show defects. 3. Controller defect.1. Adjust the mode to proper running 2. Replace the defect LED wire controller, and then check the status after changing the running mode, verifying the water inlet and outlet temperature. 3. Replace or repair the heat pump unit p.28
Short running1. Fan NO running. 2. Air ventilation is not enough. 3. Refrigerant is not enough.1. Check the cable connections between the motor and fan, if necessary, it should be replaced. 2. Check the location of heat pump unit, and eliminate all obstacles to make good air ventilation. 3 Replace or repair the heat pump unit. p.28
water stains1. Concreting. 2. Water leakage.1. No action. 2. Check the titanium heat exchanger carefully if it is any defect. p.28
Too much ice on evaporator1. Check the location of heat pump unit, and eliminate all obstacles to make good air ventilation. 2. Replace or repair the heat pump unit. p.28

Poser une question sur : Astralpool PRO-ELYO INVERTER

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Astralpool PRO-ELYO INVERTER

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Astralpool PRO-ELYO INVERTER manuel PDF

204 pages·9.9 MB·Pompe à chaleur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…