INSTALLATION INSTRUCTIONS

- Split system air conditioner -

DECLARATION OF CONFORMITY

This product is marked as it satisfies Directives:

– Low voltage no. 2006/95/EC. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012

+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011). – Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)

F

+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009), EN 61000-3-3 (2008) – RoHS2 no.2011/65/EU. – Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air

D

E

conditioners and fans. – Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air

conditioners. This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation and/or operating instructions.

P

GR

OPERATING LIMITS

Cooling Maximum conditions

Heating Maximum conditions

Outdoor temperature : 43°C D.B. Room temperature : 32°C D.B. / 23°C W.B.

Outdoor temperature : 24°C D.B. / 18°C W.B. Room temperature : 27°C D.B.

Cooling Minimum conditions

Heating Minimum conditions

Outdoor temperature : –15°C D.B. Room temperature : 5°C D.B.

Outdoor temperature : –15°C D.B. Room temperature : 10°C D.B. / 6°C W.B.

Tools required for installation (not supplied) Model Combinations:

SEE CATALOGUE

1.Standard screwdriver

19.Hammer

2.Phillips head screwdriver

10.Drill

3.Knife or wire stripper

11.Tube cutter

Power Supply:

4.Tape measure

12.Tube flaring tool

220. 240 V ~ 50 Hz

5.Level

13.Torque wrench

6.Sabre saw or key hole saw

14.Adjustable wrench

REGULATION (EU) No. 517/2014 - F-GAS

7.Hacksaw

15.Reamer (for reburring)

The unit contains R410A, a fluorinated greenhouse gas with a global warming potential (GWP) of 2087.50. Do not release R410A into the atmosphere.

8. Core bits ø 8

16.Hex. key

37.4255.144.00 11/2015

Page 2 of the Argo SDIBS9DC user manual — WARNING
Page 2 · cliquer pour agrandir
Page 2

IMPORTANT! Please read before installation

  • Ground the unit following local electrical codes.
  • The Yellow/Green wire cannot be used for any connection different from the ground connection.
  • Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
  • Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.
  • Do not use multi-core cable when wiring the power supply and control lines. Use separate cables for each type of line.

This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently.

  • For safe installation and trouble-free operation, you must:
  • Carefully read this instruction booklet before beginning.
  • Follow each installation or repair step exactly as shown.
  • Observe all local, state and national electrical codes.
  • Pay close attention to all warning and caution notices given in this manual.
  • The unit must be supplied with a dedicated electrical line.

When transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the air conditioner can cut your fingers.

When installing In a ceiling or wall Make sure the ceiling/wall is strong enough to hold the unit- weight. It may be necessary to build a strong wooden or metal frame to provide added support.

WARNING

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

... In a room Properly insulate any tubing run inside a room to prevent "sweating", which can cause dripping and water damage to walls and floors.

CAUTION

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

... In moist or uneven locations Use a raised concrete base to provide a solid level foundation for the outdoor unit. This prevents damage and abnormal vibrations.

If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.

... In area with strong winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

... In a snowy area (for heat pump-type systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

  • When connecting refrigerant tubing
  • Keep all tubing runs as short as possible.
  • Use the flare method for connecting tubing.
  • Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them; screw by hand and then tighten the nut with a torque wrench for a leak-free connection.
  • Check carefully for leaks before starting the test run.

SPECIAL PRECAUTIONS

  • During installation, connect before the refrigerant system and then the wiring one; proceed in the reverse orden when removing the units.

WARNING

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.

  • When servicing
  • Turn the power OFF at the main power board before opening the unit to check or repair electrical parts and wiring.
  • Keep your fingers and clothing away from any moving parts.
  • Clean up the site after the work, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.
  • Ventilate the room during the installation or testing the refrigeration system; make sure that, after the installation, no gas leaks are present, because this could produce toxic gas and dangerous if in contact with flames or heatsources.
  • Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked, to ensure the grounding.
  • Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury and death .

When wiring

Page 3 of the Argo SDIBS9DC user manual — TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
Page 3 · cliquer pour agrandir
Page 3
  • Installation site selection - Indoor unit AVOID
  • Direct sunlight.
  • Nearby heat sources that may affect unit performance.
  • Areas where leakage of flammable gas may be expected.
  • Locations where large amounts of oil mist may occur (such as in kitchen or near factory equipment) because oil contamination can cause operation problems and may deform plastic surfaces and parts of the unit.
  • Unsteady locations that will cause noise or possible water leakage.
  • Locations where the indoor unit and the remote control unit will be splashed with water or affected by dampness or humidity (i.e. in laundries).
  • To make holes in areas where electrical wiring or conduits are located. DO
  • Select an appropriate position from which every corner of the room can be uniformily cooled.
  • Select a sufficiently strong location to support the weight of the unit.
  • Select a location where tubing and drain hose have the shortest run to the outside.
  • Allow access for operation and maintenance as well as unrestricted air flow around the unit.
  • Installation site selection - Outdoor unit AVOID
  • Heat sources, exhaust fans.
  • Direct sunlight.
  • Damp, humid or uneven locations.
  • To make holes in areas where electrical wiring or conduits are located. DO
  • Choose places as cool as possible and well ventilated.
  • use lug bolts or equal to bolt down the unit, reducing vibration and noise.

ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)

l Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with

foamed polyethylene (min. thickness 8mm).

MODELNARROW TUBE LARGE TUBE OUTER DIAMETER MIN. THICKNESS OUTER DIAMETER MIN. THICKNESS SDIA6,35 mm0,8 mm9,52 mm0,8 mm SDIB6,35 mm0,8 mm12,7 mm0,8 mm

l PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.

l Anti-freeze oil for flare connections (about 30g).

l Electric wire: use insulated copper wires of size and length as shown in the paragraph “WIRING DIAGRAMS”.

TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS

SEE INSTALLATION INSTRUCTIONS OF OUTDOOR UNIT

(go on page 4)

Page 4 of the Argo SDIBS9DC user manual — ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Page 4 · cliquer pour agrandir
Page 4
Page 4 of the Argo SDIBS9DC user manual — ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Page 5 of the Argo SDIBS9DC user manual — PCB
Page 5 · cliquer pour agrandir
Page 5

OUTDOOR/INDOOR UNIT REFRIGERANT CIRCUIT ADDRESS

Indoor units that are part of a multisplit system must be properly configured to be able to communicate with the outdoor unit over different channels (Indoor A, Indoor B, etc...) of the communication bus. Each indoor unit address must correspond to the physical connection of the indoor unit to the outdoor unit refrigerant circuit, i.e.: Refrigerant Circuit A Indoor Unit Address A Refrigerant Circuit B Indoor Unit Address B ... There are three methods to set the address of an indoor unit: (1) Dip-switch setting: the address is set by mean of a dip-switch located on the indoor unit pcb. (2) Remote controller procedure (still available): the address is set by mean of a special setting on the remote controller. (3) Automatic addressing procedure: the address is automatically set on every indoor unit of the system by mean of an

automatic procedure.

(1) ADDRESS SETTING THROUGH DIP-SWITCHES (UP TO 4 INDOOR UNITS)

Check that the setting of switch SW2 (PCB) corresponds to the figure:

INDOOR UNIT A

INDOOR UNIT B

SW2 (PCB factory state) 1=off 2=off

PCB

INDOOR UNIT C

INDOOR UNIT D

PCB

PCB

Show 4 more labels / short text on this page
Disconnect the power · SW2 1=on 2=off · SW2 1=off 2=on · SW2 1=on 2=on
Page 6 of the Argo SDIBS9DC user manual — Any Any
Page 6 · cliquer pour agrandir
Page 6

(2) ADDRESS SETTING THROUGH REMOTE CONTROLLER (UP TO 8 INDOOR UNITS)

Set the remote controller as shown in the table.

BUTTON

Indoor unit A: 11°C Indoor unit B: 12°C Indoor unit C: 13°C Indoor unit D: 14°C Indoor unit E: 15°C Indoor unit F: 16°C Indoor unit G: 17°C Indoor unit H: 18°C

SETTING

AUTO

working mode (COOL - HEAT)

AUTO

ON OFF

night mode / high mode

Any Any

At this point, press together FAN + IFEEL buttons for more than 7 seconds and release them pointing the remote controller to the indoor unit receiver. Be sure to send the signal to only one indoor unit and that there is no other indoor unit that could receive the same signal. If the signal is received, the indoor unit will emit 5 consecutive beeps.

Show 4 more labels / short text on this page
set point · flap filter · iFeel · Fan
Page 7 of the Argo SDIBS9DC user manual — OPERATION
Page 7 · cliquer pour agrandir
Page 7

(3) AUTOMATIC ADDRESSING PROCEDURE

System requirements: Outdoor unit must have a recent firmware version that supports the automatic addressing procedure. Indoor units must have a recent firmware version that supports the automatic addressing procedure Dip-switch for communication address setting on the indoor unit (SW2) must be left to the factory default state, i.e. to the OFF position.

Activation of automatic addressing procedure Power on the whole system. Verify that there is no error on the indoor units, but the error “Address not set” (see Auto-diagnosis table). Switch on the remote controller of any of the indoor units of the system and set it as follows:

BUTTON

SETTING

working mode (COOL - HEAT)

AUTO

24°C AUTO

filter night mode / high mode

ON OFF

Any Any

Press together FAN + IFEEL buttons for more than 7 seconds and release them pointing the remote controller to the indoor unit receiver. Be sure to send the signal to only one indoor unit and that there is no other indoor unit that could receive the same signal.

If the signal is received, the indoor unit will emit 5 consecutive beeps.

After some seconds, every indoor unit will show the following LED combination to confirm that the automatic addressing procedure has been activated.

OPERATION

BLUE STANDBY

TIMER

OPERATION STANDBY TIMER ON OFF BLINKING

GREEN

RED

From this moment until the end of the procedure the indoor units will not receive anymore the signals from the remote controllers (infrared receiver is disabled).

Execution of automatic addressing procedure Once the procedure has been activated, the system will run automatically to set the address of every indoor unit. In this period, compressor and fan motor will be activated. Once activated, the procedure takes about 4-5 minutes per outdoor unit circuit to be completed. This time doesn’t depend on the number of indoor units actually connected to the outdoor unit, but on the number of refrigerant circuits of the outdoor unit.

End of automatic addressing procedure When all the circuits have been tested and the address of every indoor unit has been set, the outdoor unit will stop and every indoor unit will switch off (standby mode). In any case (procedure successful or failed) the infrared receiver of every indoor unit will be re-activated. If there is no error on the indoor units, the system is ready to be used. If there is the error “Address not set” (see Auto-diagnosis table) on any indoor unit, re-run the automatic addressing procedure or manually set the address on that indoor unit with the dip-switch or with the remote controller.

Show 4 more labels / short text on this page
set point · flap · iFeel · Fan

Poser une question sur : Argo SDIBS9DC

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Argo SDIBS9DC

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Argo SDIBS9DC manuel PDF

76 pages·5.4 MB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…