- Split system air conditioner -
This product is marked as it satisfies Directives:
– Low voltage no. 2006/95/EC. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011). – Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009), EN 61000-3-3 (2008) – RoHS2 no.2011/65/EU. – Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
E
conditioners and fans. – Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners. This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation and/or operating instructions.
GR
OPERATING LIMITS
Cooling Maximum conditions
Heating Maximum conditions
Outdoor temperature : 43°C D.B. Room temperature : 32°C D.B. / 23°C W.B.
Outdoor temperature : 24°C D.B. / 18°C W.B. Room temperature : 27°C D.B.
Cooling Minimum conditions
Heating Minimum conditions
Outdoor temperature : –15°C D.B. Room temperature : 5°C D.B.
Outdoor temperature : –15°C D.B. Room temperature : 10°C D.B. / 6°C W.B.
Tools required for installation (not supplied) Model Combinations:
1.Standard screwdriver
19.Hammer
2.Phillips head screwdriver
10.Drill
3.Knife or wire stripper
11.Tube cutter
Power Supply:
4.Tape measure
12.Tube flaring tool
5.Level
13.Torque wrench
6.Sabre saw or key hole saw
14.Adjustable wrench
REGULATION (EU) No. 517/2014 - F-GAS
7.Hacksaw
15.Reamer (for reburring)
The unit contains R410A, a fluorinated greenhouse gas with a global warming potential (GWP) of 2087.50. Do not release R410A into the atmosphere.
16.Hex. key
37.4255.144.00 11/2015

This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently.
When transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the air conditioner can cut your fingers.
When installing In a ceiling or wall Make sure the ceiling/wall is strong enough to hold the unit- weight. It may be necessary to build a strong wooden or metal frame to provide added support.
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
... In a room Properly insulate any tubing run inside a room to prevent "sweating", which can cause dripping and water damage to walls and floors.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
... In moist or uneven locations Use a raised concrete base to provide a solid level foundation for the outdoor unit. This prevents damage and abnormal vibrations.
If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.
... In area with strong winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.
... In a snowy area (for heat pump-type systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.
In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.
When wiring

l Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with
foamed polyethylene (min. thickness 8mm).
l PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
l Anti-freeze oil for flare connections (about 30g).
l Electric wire: use insulated copper wires of size and length as shown in the paragraph “WIRING DIAGRAMS”.
SEE INSTALLATION INSTRUCTIONS OF OUTDOOR UNIT
(go on page 4)



Indoor units that are part of a multisplit system must be properly configured to be able to communicate with the outdoor unit over different channels (Indoor A, Indoor B, etc...) of the communication bus. Each indoor unit address must correspond to the physical connection of the indoor unit to the outdoor unit refrigerant circuit, i.e.: Refrigerant Circuit A Indoor Unit Address A Refrigerant Circuit B Indoor Unit Address B ... There are three methods to set the address of an indoor unit: (1) Dip-switch setting: the address is set by mean of a dip-switch located on the indoor unit pcb. (2) Remote controller procedure (still available): the address is set by mean of a special setting on the remote controller. (3) Automatic addressing procedure: the address is automatically set on every indoor unit of the system by mean of an
automatic procedure.
(1) ADDRESS SETTING THROUGH DIP-SWITCHES (UP TO 4 INDOOR UNITS)
Check that the setting of switch SW2 (PCB) corresponds to the figure:
INDOOR UNIT B
SW2 (PCB factory state) 1=off 2=off
INDOOR UNIT C
INDOOR UNIT D
PCB
PCB

(2) ADDRESS SETTING THROUGH REMOTE CONTROLLER (UP TO 8 INDOOR UNITS)
Set the remote controller as shown in the table.
Indoor unit A: 11°C Indoor unit B: 12°C Indoor unit C: 13°C Indoor unit D: 14°C Indoor unit E: 15°C Indoor unit F: 16°C Indoor unit G: 17°C Indoor unit H: 18°C
AUTO
working mode (COOL - HEAT)
ON OFF
night mode / high mode
At this point, press together FAN + IFEEL buttons for more than 7 seconds and release them pointing the remote controller to the indoor unit receiver. Be sure to send the signal to only one indoor unit and that there is no other indoor unit that could receive the same signal. If the signal is received, the indoor unit will emit 5 consecutive beeps.

System requirements: Outdoor unit must have a recent firmware version that supports the automatic addressing procedure. Indoor units must have a recent firmware version that supports the automatic addressing procedure Dip-switch for communication address setting on the indoor unit (SW2) must be left to the factory default state, i.e. to the OFF position.
Activation of automatic addressing procedure Power on the whole system. Verify that there is no error on the indoor units, but the error “Address not set” (see Auto-diagnosis table). Switch on the remote controller of any of the indoor units of the system and set it as follows:
SETTING
working mode (COOL - HEAT)
24°C AUTO
filter night mode / high mode
Any Any
Press together FAN + IFEEL buttons for more than 7 seconds and release them pointing the remote controller to the indoor unit receiver. Be sure to send the signal to only one indoor unit and that there is no other indoor unit that could receive the same signal.
If the signal is received, the indoor unit will emit 5 consecutive beeps.
After some seconds, every indoor unit will show the following LED combination to confirm that the automatic addressing procedure has been activated.
BLUE STANDBY
TIMER
OPERATION STANDBY TIMER ON OFF BLINKING
GREEN
RED
From this moment until the end of the procedure the indoor units will not receive anymore the signals from the remote controllers (infrared receiver is disabled).
Execution of automatic addressing procedure Once the procedure has been activated, the system will run automatically to set the address of every indoor unit. In this period, compressor and fan motor will be activated. Once activated, the procedure takes about 4-5 minutes per outdoor unit circuit to be completed. This time doesn’t depend on the number of indoor units actually connected to the outdoor unit, but on the number of refrigerant circuits of the outdoor unit.
End of automatic addressing procedure When all the circuits have been tested and the address of every indoor unit has been set, the outdoor unit will stop and every indoor unit will switch off (standby mode). In any case (procedure successful or failed) the infrared receiver of every indoor unit will be re-activated. If there is no error on the indoor units, the system is ready to be used. If there is the error “Address not set” (see Auto-diagnosis table) on any indoor unit, re-run the automatic addressing procedure or manually set the address on that indoor unit with the dip-switch or with the remote controller.