PRODUCTS MANUAL R2W SERIES High Density Redundant Power Supply For 2U Chassis Rev .:A1 P/N:702-10041.
I N D E X 1.1 Introduction page 2 1.2 Packing page 3 1.3 Model Designation page 3 1.4 Features page 4 1.5 Pre-Installation page 4 1.6 Drawing page 5 ~ 6 1.7 Specification page 7 ~ 9 1.8 Installation & T esting page 10 ~ 1 1 1.9 Hot-Swap Procedures page 1 1 ~ 12 1.
1.1 INTRODUCTION First of all, thank you for purchasing R2W Series – High-Density Redundant power supply for 2U chassis. The R2W is a 1+1, Hot-swappable/Hot-pluggable, High-Density Redundant power s.
1.2 P ACKING Y our R2W box package should consist of the following: (A) R2W *1 (B) Accessory pack (included 1 holding bracket for shipment)*1 (C) Products’ manual *1 1.3 MODEL DESIGNA TION Model number identification: R2W – 6ZZZP R --- Redundant (AC Input) 2W --- suit for 2U chassis (1U = 44.
1.4 FEA TURES R2W Series --- High-Density Redundant power supply with Active Power Factor c o r r e c t i o n 1+1, Hot swappable, Hot pluggabl e, AC Input for 2U chassis Easy fit into 2U , 400/460W +4.
.
.
INPUT CHARACTERISTICS: R2W-6400P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
INPUT CHARACTERISTICS: R2W-6460P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
INPUT CHARACTERISTICS: R2W-6500P VOLTAGE: 105 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 Hz INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE OUTPUT CHARACTERISTICS: OUTPUT CURRENT REGULATION OUTPUT MIN.
1.8 INST ALLA TION & TESTING T urn of f (Remote off) the on/of f switch. Mount the power supply in the system chassis using the proper mounting tool, the mounting holes in the power supply should match those in the case.
If everything works out fine, then turn off (rem ote off) the power system. Now put back the cover of the case and tighten with the screws that you have retained earlier . Now you have completed the in stallation of the R2W redundant power supply system.
D) Replace a new Good power module, insert the power module into the power system to the end. E) Check the LED of the power module light Green. F) Check the LED indicating the total power system status. It should be from twinkle to Green. G) T ighten the screws of the power module to fix it.
TTL signal : S i n k c u r r e n t m a x . 5 m A S o u r c e c u r r e n t m a x . 5 0 u A Low Active --- Defective High --- Normal 1.11 TROUBLE SHOOTING If you have followed these directions correctly , there should be no problem occurred. Some comm on symptoms are: the system doesn’ t work, buzzer sounds, work for a very short period, etc.
The “RELIABILITY “ solution to E-application 新巨企業股份有限公司 ZIPPY TECHNOLOGY CORP . POWER DIVISION HEADQUAR TERS 10F , NO. 50, MIN CHYUAN RD., SHIN-TIEN CITY , T AIPEI HSIEN, T AIW AN, R.O.C. TEL: 886-2-29188512 F AX: 886-2-29134969 WEB SITE: http://www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Zippy R2W-6500P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Zippy R2W-6500P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Zippy R2W-6500P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Zippy R2W-6500P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Zippy R2W-6500P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Zippy R2W-6500P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Zippy R2W-6500P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Zippy R2W-6500P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.